Please see reverse for Technical Specifications
Important Information:
• Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
• DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to your vehicle Owner’s Manual for the location of any air bag deployment zones.
• DO NOT connect this device to a strobe power supply. This product is self-contained and does not require an external power supply.
GASKET
Note: Lens shown is representative only.
LIGHT ASSEMBLY
WARNING
!
This product contains high intensity LED devices. To
prevent eye damage, DO NOT stare into the light
beam at close range.
1. Determine a clean, flat location on the vehicle to mount the GHOST light.
2. Using template on reverse side, mark and drill holes in 4 corners. Holes to be Ø0.46” (approx. Ø15/32”).
3. Carefully cut sheet metal and ensure there are no sharp edges.
4. Press gasket into opening.
5. Make electrical connections.
6. Test light.
7. Press light into gasket.
OPERATION:
WIRE CONNECTIONS
See setup procedure on second page.
The single GHOST comes equipped with an internal flasher with 3 user selectable patterns that can be synchronized either alternating or simultaneous with up to three other lights. It can also be put into slave mode and driven through an external flasher.
1. Connect the GHOST BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire to one side
of a user supplied on/off switch. Connect the other side of the switch, through a 5Amp fuse, to a source of +10-30Vdc.
3. Cruise mode is activated by applying
power to BROWN wire while RED wire is powered. NOTE: Cruise mode is STEADY-ON at 20% light output.
4. To sync lights and make pattern
selections see reverse side.
WIRE HOOK-UP TABLE
WIRE COLOR: CONNECT TO:
RED +10-30Vdc
BLACK Ground (-)
WHITE ID/Pattern Select
BROWN WIRE +10-30Vdc
Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
1.800.338.7337 / www.soundoffsignal.com
IMPORTANT INFORMATION:
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800.338.7337 (press #4 to skip the automated message).
Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsigal.com.
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
EGHSTE5(xx) 07.14
RECESS MOUNT ECE65 CERTIFIED w/ STANDARD LENS
SINGLE LIGHT EGHSTE5(x)B - Black EGHSTE5(x)W - White EGHSTE5(x)C - Chrome
RECESS MOUNT ECE65 CERTIFIED w/ XYLEX LENS
SINGLE LIGHT EGHSTE5(x)B-EU - Black EGHSTE5(x)W-EU - White EGHSTE5(x)C-EU - Chrome
1 Cut hole in sheet metal
2 Press gasket into hole
ONE (1) LIGHT
Single Light Operation: Follow the ID Selection steps and set the ECE GHOST to ID#1 if it is not already.
TWO (2) LIGHTS
ALTERNATING: To obtain Alternating patterns, follow the ID
SELECTION steps and set one ECE GHOST to ID#1 and the other to ID#3. Then proceed to the PATTERN SELECTION steps.
SIMULTANEOUS: To obtain Simultaneous patterns, follow the ID SELECTION steps and set both ECE GHOST lights to ID#1. Then proceed to PATTERN SELECTION steps.
SLAVE MODE
The GHOST is capable of being activated through the use of a use sup plied flasher by putting it in slave mode.
1. Permanently connect the GHOST WHITE and BLACK wire to a good, convenient ground.
2. Connect the GHOST RED wire, through a 5Amp fuse, to the output of a +10-30 Vdc switching flasher.
PATTERN RESET
1. Remove power
2. Place WHITE (sync) wire to ground
3. With sync wire grounded, re-power RED wire
4. Maintain for one second (light will dim)
5. Remove power and ground (pattern 1 set)
-
TECHNICAL SPECIFICATIONS
Overall Dimensions: 1.55” H x 4.67” W x 0.98” D
Input Voltage Range: 10 - 30 Vdc
Current Consumption:
0.75 Amps max / module (flash pattern dependent)
# of LEDs: 6 Generation 3 LEDs
Light Sync Technology: Yes
Operating Temperature: -40º to +65º C
Cruise Light Mode:
Yes
ECE GHOST Sync Configuration Instructions
IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS CAN BE SYNCED TOGETHER
1. Set ID# a. Identify which pattern and sequence you want and look up ID#
settings at right.
b. Connections i. RED: +12Vdc ii. WHT: +12Vdc (Note: you will need to disconnect after power is applied) iii. BLK: Ground c. Apply power to unit d. Without disconnecting power from unit, disconnect WHT wire e. Momentarily connect WHT to Ground to change ID # i. Identify ID# by number of sequential flashes ii. Possible ID#s: 1 – 4 f. Disconnect power from unit to get out of ID mode.
2. Set Pattern a. Reapply power to units. b. Once all Light Head ID#s are configured, make sure all lights are flashing the same pattern c. Connect corresponding colored wires of all units together: RED to RED, etc. d. Change Pattern i. Momentarily touch WHT wires to Ground ii. Observe pattern change on all lights connected e. Insulate all wires by taping with electrical tape
3. Connect Master Switch for Application a. IMPORTANT! Ensure WHT Pattern/Sync Wires are tied together
Flash Patterns
Pattern Name
1. Single 125
2. Double 125
3. Triple 123
FPM
(Flashes per Minute)
3 Make wiring connections
4 Test
5 Install light
NOTE:
The GHOST is a factory sealed unit that CANNOT be serviced in the field. Any attempt to gain access to the GHOST unit will most likely cause permanent damage and void its warranty.