GHOST® SINGLE MULTI-MOUNT LIGHT, ECE CERTIFIED
SINGLE LIGHT
EGHSTE1(x)B - Black
EGHSTE1(x)W - White
EGHSTE1(x)C - Chrome
GHOST® SINGLE MULTI-MOUNT LIGHT, ECE65 CERTIFIED,
XYLEX LENS
SINGLE LIGHT
EGHSTE1(x)B-EU - Black
EGHSTE1(x)W-EU - White
#10 thread forming screws (included)
Supplied #10-24 3/8” lg. hex
drive set screw
Hole with #27 drill
Permanent Mount Adhesive Mount Single Edge Mount Bracket
Important Information:
• Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances.
These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these
devices to ensure compliance.
• DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to your vehicle
Owner’s Manual for the location of any air bag deployment zones.
• DO NOT connect this device to a strobe power supply. This product is self-contained and does not
require an external power supply.
Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
1.800.338.7337 / www.soundoffsignal.com
If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800.338.7337 (press #4 to skip the automated message).
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsigal.com.
INSTALLATION:
1. Screw Mount
Establish a position on the vehicle. Use
the mounting slots as a template to mark
hole locations. Drill a hole using a #27 drill
bit. The Torx screws provided are selftapping.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
2. Adhesive Mount
To obtain optimum adhesion, the bonding
surfaces must be well unified, clean and dry.
Peel one side of each adhesive mounting
patch provided. Apply each rectangular
patch to the bottom of the GHOST housing.
Position the GHOST on the vehicle and mark
2 edges of the location using tape. Peel the
remaining paper from the adhesive patch
and carefully position the light using the
tape template. Press down on housing firmly
to insure good adhesive contact. Important:
Apply carefully; adjustment is not possible
after the adhesive bonds. Ultimate strength
of adhesive is achieved after 24 hours.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
3. New ‘U’ bracket for mounting on hood or
trunk edge.
Open the hood or trunk that will be
the attachment surface. Place the rubber
pad provided on the surface, insuring that
the lower lip is on the edge of the sheet
metal. Fit the ‘U’ bracket to the back of the
GHOST light base, nesting the bracket holes
with the pins on the light base. Slide the
assembly onto the rubber pad. Tighten the
four set screws.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
IMPORTANT INFORMATION:
OPERATION:
WIRE CONNECTIONS
See setup procedure on second page.
The single GHOST comes equipped with
an internal flasher with 3 user selectable
patterns that can be synchronized either
alternating or simultaneous with up to three
other lights. It can also be put into slave
mode and driven through an external flasher.
1. Connect the GHOST BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire to one side
of a user supplied on/off switch. Connect the
other side of the switch, through a 5Amp
fuse, to a source of +10-30Vdc.
3. Cruise mode is activated by applying
power to BROWN wire while RED wire is
powered. NOTE: Cruise mode is STEADY-ON
at 20% light output.
4. To sync lights and make pattern
selections see reverse side.
TECHNICAL SPECIFICATIONS
Overall Dimensions:
Input Voltage Range: 10-30 Vdc
Current Consumption:
Light Sync Technology Yes
Operating
Temperature:
!
WARNING
This product contains high
intensity LED devices. To prevent
eye damage, DO NOT stare into
light beam at close range.
(flash pattern dependent)
4” L
x 0.88” H x 1.75” D
0.75 Amps max/light
-20º to +65º C
EGHSTE1(x) 07.14
SINGLE MULTI-MOUNT ECE65 CERTIFIED w/ STANDARD LENS
SINGLE LIGHT
EGHSTE1(x)B - Black
EGHSTE1(x)W - White
EGHSTE1(x)C - Chrome
SINGLE MULTI-MOUNT ECE65 CERTIFIED w/ XYLEX LENS
SINGLE LIGHT
EGHSTE1(x)B-EU - Black
EGHSTE1(x)W-EU - White
EGHSTE1(x)C-EU - Chrome
Flash Patterns
Flash Patterns
1. Single 125
2. Double 125
3. Triple 123
WIRE HOOK-UP TABLE
WIRE COLOR: CONNECT TO:
RED +10-30 Vdc
BLACK Ground (-)
WHITE ID/Pattern Select
BROWN WIRE +10-30 Vdc
FPM
(Flashes per Minute)
ECE GHOST Sync Configuration Instructions
IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS
CAN BE SYNCED TOGETHER
1. Set ID#
a. Identify which pattern and sequence you want and look up ID#
settings at right.
b. Connections
i. RED: +12Vdc
ii. WHT: +12Vdc (Note: you will need to disconnect after
power is applied)
iii. BLK: Ground
c. Apply power to unit
d. Without disconnecting power from unit, disconnect WHT
wire
e. Momentarily connect WHT to Ground to change ID #
i. Identify ID# by number of sequential flashes
ii. Possible ID#s: 1 – 4
f. Disconnect power from unit to get out of ID mode.
2. Set Pattern
a. Reapply power to units.
b. Once all Light Head ID#s are configured, make sure all
lights are flashing the same pattern
c. Connect corresponding colored wires of all units together:
RED to RED, etc.
d. Change Pattern
i. Momentarily touch WHT wires to Ground
ii. Observe pattern change on all lights connected
e. Insulate all wires by taping with electrical tape
3. Connect Master Switch for Application
a. IMPORTANT! Ensure WHT Pattern/Sync Wires are tied
together
NOTE:
#10 thread forming screws (included)
Hole with #27 drill
The GHOST is a factory sealed unit that CANNOT be serviced
in the field. Any attempt to gain access to the GHOST unit will
most likely cause permanent damage and void its warranty.
Supplied #10-24 3/8” lg. hex
drive set screw
Permanent Mount Adhesive Mount Single Edge Mount Bracket
ONE (1) LIGHT
Single Light Operation: Follow the ID Selection steps and set the
ECE GHOST to ID#1 if it is not already.
TWO (2) LIGHTS
ALTERNATING: To obtain Alternating patterns, follow the ID
SELECTION steps and set one ECE GHOST to ID#1 and the other
to ID#3. Then proceed to the PATTERN SELECTION steps.
SIMULTANEOUS: To obtain Simultaneous patterns, follow the ID
SELECTION steps and set both ECE GHOST lights to ID#1. Then
proceed to PATTERN SELECTION steps.
SLAVE MODE
The GHOST is capable of being activated through the use of a use
supplied flasher by putting it in slave mode.
1. Permanently connect the GHOST WHITE and BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire, through a 5Amp fuse, to the output
of a +10-30Vdc switching flasher.
PATTERN RESET
1. Remove power
2. Place WHITE (sync) wire to ground
3. With sync wire grounded, re-power RED wire
4. Maintain for one second (light will dim)
5. Remove power and ground (pattern 1 set)
1.800.338.7337 / www.soundoffsignal.com
EGHSTE1(x) 07.14