![](/html/9a/9aa5/9aa58c16de1e84736732550c50268b663f903db8b89698c97796ba3e1bdf52cf/bg1.png)
INSTALLATION:
OPERATION:
GHOST® DUAL MULTI-MOUNT LIGHT
EGHST1(x)-12 - Black
EGHST1(x)W-12 - White
Supplied #10 thread forming screw.
Hole with #27 drill
Screw Mount Adhesive Mount ‘U’ bracket
Important Information:
• Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances.
These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these
devices to ensure compliance.
• DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to your vehicle
Owner’s Manual for the location of any air bag deployment zones.
• DO NOT connect this device to a strobe power supply. This product is self-contained and does not
require an external power supply.
Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800.338.7337 (press #4 to skip the automated message).
1.800.338.7337 / www.soundoffsignal.com
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
Supplied #10-24 3/8” lg. hex
drive set screw
Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsigal.com.
1. Screw Mount
Establish a position on the vehicle. Use
the mounting slots as a template to mark
hole locations. Drill a hole using a #27 drill
bit. The Torx screws provided are selftapping.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
2. Adhesive Mount
To obtain optimum adhesion, the bonding
surfaces must be well unified, clean and dry.
Peel one side of each adhesive mounting
patch provided. Apply each rectangular
patch to the bottom of the GHOST housing.
Positon the GHOST on the vehicle and mark
2 edges of the location using tape. Peel the
remaining paper from the adhesive patch
and carefully position the light using the
tape template. Press down on housing firmly
to insure good adhesive contact. Important:
Apply carefully; adjustment is not possible
after the adhesive bonds. Ultimate strength
of adhesive is achieved after 24 hours.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
3. New ‘U’ bracket for mounting on hood or
trunk edge.
Open the hood or trunk that will be the
attachment surface. Place the rubber pad
provided on the surface, insuring that the
lower lip is on the edge of the sheet metal.
Fit the ‘U’ bracket to the back of the GHOST
light base, nesting the bracket holes with
the pins on thelight base. Slide the assembly
onto the rubber pad. Tighten the four set
screws.
Loosen the two #10 TORX screws on
the back of each housing to adjust the angle
of the GHOST. After adjustment, tighten the
TORX screws.
IMPORTANT INFORMATION:
WIRE CONNECTIONS
See setup procedure on second page.
The single GHOST comes equipped with
an internal flasher with 33 user selectable
patterns that can be synchronized either
alternating or simultaneous with up to three
other lights. It can also be put into slave
mode and driven through an external flasher.
1. Connect the GHOST BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire to one side
of a user supplied on/off switch. Connect the
other side of the switch, through a 5Amp
fuse, to a source of +10-16Vdc.
NOTE:
The GHOST is a factory sealed unit that
CANNOT be serviced in the field. Any
attempt to gain access to the GHOST unit
will most likely cause permanent damage
and void its warranty.
TECHNICAL SPECIFICATIONS
Overall Dimensions: 4”L x 0.88”H x
Input Voltage Range: 10-16Vdc
Current Consumption: 0.75 Amps /module*
Light Sync Technology Yes
Operating Temperature: -20º to +65º C
# of Flash Patterns 33
*Pattern Dependent
!
WARNING
This product contains high
intensity LED devices. To prevent
eye damage, DO NOT stare into
light beam at close range.
1.75”D
EGHST1(xx)-12 7.14
![](/html/9a/9aa5/9aa58c16de1e84736732550c50268b663f903db8b89698c97796ba3e1bdf52cf/bg2.png)
GHOST® DUAL MULTI-MOUNT LIGHT
EGHST1(x)-12 - Black
EGHST1(x)W-12 - White
1 SINGLE LIGHT
Follow the ID selection steps and set the GHOST to the following ID:
- Alternating (default): ID#1 or ID#3. (inludes cycle patterns
and steady burn patterns)
- Simultaneous: ID#2 or ID#4. (both lights will flash together
regardless of pattern)
2 SINGLE LIGHTS
Follow the ID selection steps and set the GHOST to the following ID:
***IMPORTANT: Make sure both lights flash the same pattern!***
- Both assemblies simultaneous with individual lights alternating.
- Example: Driver/Passenger sim; Dr.(left alt right)
Pass.(left alt right)
- Set both GHOST Assemblies to ID#1
- Both assys. alternating with individual lights alternating.
- EX: Dr./Pass. alt; Dr.(left. alt. right.) Pass.(right alt. left)
- Set one GHOST to ID#1 and the other to ID#3
- Both assys. alternating with individual lights simultaneous
- EX: Dr./Pass. alt; Dr.(left sim left) Pass.(right sim right)
- Set one GHOST to ID#2 and the other to ID#4
- Both assys. simultaneous with individual lights simultaneous.
- EX: Dr./Dr. sim; Dr.(left sim left) Pass.(right sim right)
- Set both Ghost housings to ID#2
X-PATTERN - To obtain X-Patterns, follow the ID SELECTION steps and set
one of the four GHOST lights to ID#1, one to ID#2, one to ID#3, and
one to ID#4. Then proceed to the PATTERN SELECTION steps.
NOTE: Be sure to mount each GHOST in the correct placement
based on ID#.
PATTERN SELECTION
1. Disconnect WHITE wire from any connections if applicable.
2. Turn GHOST ON.
3. Momentarily touching and removing the WHITE wire(s) to ground
will advance the GHOST to the next flash pattern. Touching and removing
the White wire for more than a few seconds will allow you to change the
GHOST to the previous pattern. See flash pattern table. Continuing to
touch and remove the WHITE wire(s) to ground will allow you to scroll
through the pattern list. After pattern #33 is reached the list will start over
again at pattern #1.
X-Pattern Sequence
ID#1> ID#4> ID#2> ID#3
X-Pattern Light Head Placement
ID#4 ID#2
ID#3 ID#1
NOTE: The GHOST is equipped with flash pattern memory. Once you have
selected a pattern the GHOST will always activate to that pattern every time
the unit is turned on. Tape up and secure WHITE wire so that it will not ac
-
cidentally change your selected pattern.
Ghost Sync Configuration Instructions
IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS
CAN BE SYNCED TOGETHER
1. Set ID#
a. Identify which pattern and sequence you want and look up
ID# settings at left.
b. Connections
i. RED: +10-16Vdc
ii. WHT: +10-16Vdc (Note: you will need to disconnect
after power is applied)
iii. BLK: Ground
c. Apply power to unit
d. Without disconnecting power from unit,
disconnect WHT wire
e. Momentarily connect WHT to Ground to change ID #
i. Identify ID# by number of sequential flashes
ii. Possible ID#s: 1 – 4
f. Disconnect power from unit to get out of ID mode.
2. Set Pattern
a. Reapply power to units.
b. Once all Light Head ID#s are configured, make sure all
lights are flashing the same pattern.
c. Connect corresponding colored wires of all units together:
RED to RED, etc.
d. Change Pattern
i. Momentarily connect WHT wires to Ground
ii. Observe pattern change on all lights connected
e. Insulate all wires by taping with electrical tape
3. Connect Master Switch for Application
a. IMPORTANT! Ensure WHT Pattern/Sync Wires are tied
together.
PATTERN RESET
1. Remove power
2. Place WHITE (sync) wire to ground
3. With sync wire grounded, re-power RED wire
4. Maintain for one second (light will dim)
5. Remove power and ground (pattern 1 set)
SLAVE MODE
The GHOST is capable of being activated through the use of a user
supplied flasher by putting it in slave mode.
1. Permanently connect the GHOST WHITE and BLACK wire to a
good, convenient ground.
2. Connect the GHOST RED wire, through a 5Amp fuse, to the output
of a +10-16Vdc switching flasher.
Flash Patterns
Pattern Name 1 Light
1. Quint
2. Warp
3. Inter-Cycle Flash
4. Double Flash
5. Quad Flash
6. PowerPulse
7. RoadRunner
8. Q-Switch
9. RoadRunner Steady Burn
10. Quad Steady Burn
11. E-Ideal Single Flash
12. E-Ideal Double Flash
13. Quad2 Flash
14. Double2 Flash
15. X-Warp
16. X-Double
17. PowerRunner
18. LCR Quint
3
19. Warp
20. Ultra Warp
21. Thunder & Lightning
22. Lite Speed
23. SuperSonic
24. LCR Lite Speed
25. SuperSonic Ultra
26. Tempo Shift
27. Tempo Shift Warp
28. SBE2
2
29. C
2
30. U
31. Ultra Glow
32. Cyclone
33. Chameleon
x x x 70
x x x 350
x x
x x x 70
x x x 80
x x x 180
x x x 113
x x
x x 113
x x 80
x x x 200
x x x 146
x x x 67
x x x 95
x x x
x x x
x x x
x x x 545
x x
x x x 85
x x 170
x x x
x x x
x x x
x x x
x x x 67
x x x 200
x x x 176
x x x
x x x
x x x
Alternating 2
Lights
Silmultaneous
2 Lights
X-Pattern
4 Lights
x
x
F.P.M.
(Flashes / Minute)
1.800.338.7337 / www.soundoffsignal.com
EGHST1(xx)-12 7.14