Soundoff Signal 380 SERIES, ETSA380R Instruction Manual

Page 1
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product please visit our website at www.soundoffsignal.com and select the “Warranty & Returns”
link along the left column of our home page. If you have questions regarding this product please contact Technical Services, Monday - Friday, 8 am to 5 pm at 1.800.338.7337, press #4 to
skip the automated message. Questions or comments that do not require immediate attention may be emailed to techsupport@soundoffsignal.com.
1.800.338.7337. / www.soundoffsignal.com / Thank you for trusting us with your safety!
Effective sirens generate loud sound pressure levels that can potentially cause hearing damage. Installers and those around the vehicle need to be aware of the dangers and wear hearing protection whenever the siren system is operating. Vehicle operators and occupants should assess their exposure to siren noise and determine what steps need to be taken to prevent hearing damage.
The siren system is intended for use by authorized personnel only. It is the user’s responsibility to ensure they understand and operate the emergency warning devices in compliance with all applicable city, state, and federal laws and regulations. SoundOff Signal assumes no liability for any loss resulting from the use of the siren system.
Package Contents:
1 ea. Amplifier Box 1 ea. Microphone Bracket w/ Mounting
Hardware
4 ea. Amplifier Wire Harnesses with
Connectors (1-4 pin, 1-12 pin, 1-5 pin
and 1-14 pin) 1 ea. Instruction Manual 1 ea. Operators Warning Card to remain in
vehicle for operator review 1 ea. Sound Pressure Warning Label that is
to be attached in vehicle and in plain
site of operator and occupants of the
vehicle 1 ea. Mounting Bracket with Hardware 1 ea. Label Card for Aux. Switches
Wire capacity requirements for siren amplifier (incoming power)-each supply and ground wire. 0-10 Feet: 14 AWG 10-20 Feet: 12 AWG 20-30 Feet: 10 AWG 30+ Feet: Consult Factory to determine
requirements
380 SERIES REMOTE SIREN
ETSA380R
Please see back page for Technical Specifications
ETSA380R 4.12
• Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances.
These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
Important Information:
IMPORTANT NOTICE TO INSTALLER:
Make sure to read and understand all instructions and warnings before proceeding with the installation of this product. Ensure the manual and all warning cards are delivered to the end user of this equipment.
Introduction
The ETSA380R is Remote Mounted Siren Amplifier designed for dual 100 Watt speaker use. The siren comes standard with a noise-cancelling microphone for PA use. The amplifier box contains a dual amplifier capable of supplying sound to dual 100 Watt speakers. The ETSA380R also includes a 3 position slide switch and 8 independently controlled accessory switches each capable of supplying 10-20 amps.
The primary operating modes are User Selectable tone, Yelp, Wail, Radio, PA, Horn Override, and a push-button Manual Override are available in all modes. All tones except Wail and Yelp for California Title 13 compliance may be disabled by programming the siren.
Sirens provide an essential function of an effective audio / visual warning system. However, sirens are only short range secondary devices. The use of a siren does not insure that all drivers can or will abide by or react to an emergency warning signal, especially at high rates of speeds or long distances. The operator of the vehicle must never take the right of way for granted and it is the operator’s responsibility to proceed safely.
The effectiveness of this siren system is highly dependant on the correct mounting and wiring. The installer must read and follow the manufacturer’s installation instructions and warnings in the manual. The vehicle operator should verify the siren system is securely fastened to the vehicle and properly functioning.
!
WARNING
Sirens produce loud sounds that may damage hearing:
- Roll up windows.
- Wear hearing protection.
- Use only for emergency response.
- Avoid exposure to siren sound outside of vehicle.
Control Panel (Universal Bail Bracket included - not shown)
Amplifier
Microphone
Page 2
ETSA380R 4.12
380 SERIES REMOTE SIREN
ETSA380R
PARK KILL WILL DEACTIVATE SIREN
-AUX AND HORN RING WILL NOT REACTIVATE ONLY YELP, WAIL OR TONE BUTTONS WILL REACTIVATE
**Relay 'X' is the relay associated with the pushbutton programmed for arrow control. (ie. Button 1 is set up for Arrow control, then Relay 1 is Relay 'X')
FUNCTION **RELAY
‘X’
RELAY #9
OFF
OFF OFF
LEFT ARROW
ON OFF
RIGHT ARROW
OFF ON
CENTER OUT ARROW
ON ON
+10-30V - Push Button #1 Output
+10-30V - Push Button #2 Output
+10-30V - Push Button #3 Output
+10-30V - Push Button #4 Output
Push Button #7 Normally Closed Output
Push Button #8 Normally Open Output
Push Button #7 Normally Open Output
BLUE
BROWN
YELLOW
ORANGE
RED/WHITE
GREEN/BLACK
RED/BLACK
WHITE
VIOLET
GREY
RED
GREEN
BLACK
GREEN/WHITE
+10-30V - Push Button #5 Output
+10-30V - Push Button #6 Output
+10-30V - Relay #9 Output for 2 wire Arrow Control Interface
Push Button #7 Input
Push Button #8 Input
Push Button #8 Normally Closed Output
+10-30V
50A Fuse
+10-30V Level 3 Output
+10-30V
Level 2 Output
+10-30V Level 1 Output
+10-30V
50A Fuse
YELLOW
GREEN
BLUE
RED
RED
Cable to control panel
4” RJ-45 Jumper
Cable
+10-30V
+10-30V
RADIO
REBROADCAST
BLUE BLUE
PARK KILL
YELLOW
BLACK
RED
15 amp
Fuse
15 amp
Fuse
+10-30V IGNITION
ORANGE/BLACK
Backlight
Horn Ring Out
(WHITE)
Horn Ring In
(WHITE/BLACK)
+10-30V
VIOLET
GRAY
Auxiliary
NEUTRAL SAFETY SWITCH
RADIO REBROADCAST OUPUT LEVEL ADJUST
3 amp
Fuse
ORANGE/BLACK
ORANGE
11 Ohm Speaker
100 Watt
GREEN/BLACK
GREEN
11 Ohm Speaker
100 Watt
PSRNFLT1*
*IMPORTANT NOTE: In-line filter (PSRNFLT1) must be installed to protect amplifier and speakers from damage.
Note: All fuses shown are user supplied & must be installed to ensure safe operation
MUST BE CONNECTED TO SAME SOURCE CONSTANT, TIMED OR IGNITION
NOTICE: When an output is connected to a device which is required to function only when ignition switch is ON, a relay needs to be installed in-line with the siren switch output to ensure an operator can’t activate the device without the ignition switch ON. See wiring diagram details:
Page 3
Input Settings:
1. Press and Hold Auxiliary Button #1 and #3 until slide switch #3 LED flashes.
a. Park Kill Polarity Mode
ON = Activate when input connected to +12V OFF = Activate when input connected to Ground
b. Horn Ring Polarity Mode
ON = Activate when input connected to +12V OFF = Activate when input connected to Ground
c. Tone Button
ON = ENABLED OFF = DISABLED
d. Level 3 Tone Activation
ON = Siren Tone is always enabled OFF = Siren Tone is enabled whenever is in
position #3.
e. Horn Ring Timeout
ON = Horn Ring has 8 second Timeout
OFF = Horn Ring will not Timeout
f. Park Latch
ON = Park Kill Latches, requiring operator reset
OFF = Park Kill resets when connection is
removed
g. Horn Ring Scroll
ON = Horn Ring will scroll through tones
OFF = Horn Ring will cycle between 2 tones
*Hands free mode must be enabled h. Auxiliary Input
ON = Auxiliary Input activates Air Horn
OFF = Auxiliary Input activates Tone
2. When finished, momentarily depress Radio Rebroadcast button to exit programming mode.
380 SERIES REMOTE SIREN
ETSA380R
ETSA380R 4.12
Programming Modes
Auxiliary Switch Settings:
Refer to Figure at bottom center for Button and LED locations
and terminology
1. Press and Hold Auxiliary Button #1 and #8 until slide switch #1 LED flashes.
2. Press the button which setting is going to be viewed/ changed 1 time.
3. Monitor the 5 LED’s for the arrow controller to determine setting
- Arrow Controller (Left, Right, Center, OFF) - Alternate Action Switch (Press ON / Press OFF) - Momentary Action Switch (ON only when
depressed)
- 8 Second ON Time (ON for 8 seconds when
depressed)
- Level 1 Disable (Turns OFF Level 1 Output) - Level 2 Disable (Turns OFF Level 2 Output) - Left Arrow Output - Right Arrow Output - Center Arrow Output - *Warning Bar Output
4. Press and release button until desired mode is selected.
5. Continue steps 2-3 for any other buttons that need to be programmed.
6. When Finished, momentarily depress Radio Rebroadcast button to exit programming mode.
LEGEND:
ON
OFF
Slide Switch Settings:
1. Press and Hold Auxiliary Button #1 and #4 until slide switch #2 LED flashes.
2. Press Auxiliary switch 1, 2, or 3 depending on which configuration for the slide switch is required.
3. Auxiliary Switch #1 Illuminated (Mode #1)
a. -Slide Switch Position 1 b. -Slide Switch Position 2 c. -Slide Switch Position 3
4. Auxiliary Switch #2 Illuminated (Mode #2)
a. -Slide Switch Position 1 b. -Slide Switch Position 2 c. -Slide Switch Position 3
5. Auxiliary Switch #3 Illuminated (Mode #3)
a. -Slide Switch Position 1 b. -Slide Switch Position 2 c. -Slide Switch Position 3
6. When finished, momentarily depress Radio Rebroadcast button to exit pro­gramming mode.
Denotes Factory Default Setting
Slide Switch LEDs Arrow Control LEDs
AUXILLARY BUTTON #s 1-2-3-4 5-6-7-8
*Special function which will automatically turn ON when Arrow function is selected
Default Settings:
Button #1: Arrow Controller Button #2-7: Alternate Action Switch Button #8: 8 Second ON Time
Page 4
ETSA380R 4.12
Slide Switch LEDs Arrow Control LEDs
AUXILLARY BUTTON #s 1-2-3-4 5-6-7-8
Denotes Factory Default Setting
380 SERIES REMOTE SIREN
ETSA380R
LOW 265374
HIGH
Setting PA Volume:
1. Press and Hold Auxiliary Button #1 and #2 until slide switch #2 and #3 LED flashes.
a. Depress and hold PA switch on microphone and press Push-
button 1-8 depending on volume required. When correct volume is determined, press Radio Rebroadcast and the volume setting will be permanently stored.
Other Modes:
1. Press and Hold Auxiliary Button #1 and #5 until slide switch #1 and #3 LED flashes.
a. Horn Ring Activation ON = Enabled whenever siren is
in the “ON” position.
OFF = Enabled only when slide
switch is in position 3.
b. Buzzer
ON = Enabled OFF = Disabled
c. Speakers
ON = 2 Speakers OFF = 1 Speaker
d. Hands Free Mode
ON = Hands Free Mode
OFF = Standard
e. Off Delay
ON = Siren will operate w/ignition input OFF OFF = Siren will turn OFF when ignition input is OFF
Other Modes (con’t):
f. Horn Ring Standby Tone
ON = Air Horn
OFF = Wail Button Tone
g. 8 Second level / Aux Switch Buzzer Alert
ON = Enabled - Buzzer will sound
whenever level switch is not Off or Aux switches are On
OFF = Disabled
h. Air Horn Button Output Channels
ON = In standby mode, Air Horn tone is output on Spkr A and B
When Warning Tone is Active, Warning
Tone continues on Spkr A and Air Horn Button Tone is output on Spkr B
OFF = Air Horn Button Tone always
produced on Spkr A and B
2. When finished, momentarily depress Radio Rebroadcast button to exit programming mode.
Alternate Modes:
1. Press and Hold Auxiliary Button #2 and #6 until Slide Switch #1 and #2 LED flashes.
a. Alternate Horn Ring Control
ON = Enabled
OFF = Disabled
b. Alternate Horn Ring Control Option (Disabled if Alternate
Horn Ring Control is not enabled.
ON = Option 2
OFF = Option 1
ALTERNATE HORN RING CONTROL
OPTION 1 OPTION 2
STANDBY
OEM HORN OEM HORN
LEVEL 1
OEM HORN OEM HORN
LEVEL 2
Air Horn or Wail
Button Tone
while Pressed
(programmable)
Tap to Turn On Warning Tone, Tap again to Change Warning
Tone. Press and Hold for Air
Horn Tone
LEVEL 3
Tap to turn ON
Warning Tone, Tap
again to change Warning Tone. Press and Hold for Air Horn
Tone
TONE
SWITCH OFF:
Air Horn Tone
or Wail Button
Tone while
Pressed
TONE
SWITCH ON:
Tap to change Warning Tone, Press and Hold
for Air Horn
Tone
c. Gun Lock Security
ON = Operator must press Standby button
within 1 second after pressing 8 second time delay button to active switch
OFF = 8 second time delay switch is
activated immediately when pressed
OPERATING MODE:
Backlight Intensity: While pressing RADIO REBROADCAST BUTTON, press Auxiliary Button 1-8 to adjust backligh
intensity. Button 1 = Lowest intensity, Button 8 = Highest intensity.
Page 5
380 SERIES REMOTE SIREN
ETSA380R
ETSA380R 4.12
BUTTON #6BUTTON #7BUTTON #8SPKR A SPKR B
OFF OFF OFF WAIL 1 WAIL 1
OFF OFF ON WAIL 2 WAIL 2
OFF ON OFF WAIL 1 WAIL 2
OFF ON ON WAIL 1 YELP 1
ON OFF OFF WAIL 1 ALERT A
ON OFF ON WAIL 1 HiLo
ON ON OFF WAIL 2 SUPER HiLo
ON ON ON WAIL 2 PIERCER
WAIL BUTTON
BUTTON #6BUTTON #7BUTTON #8SPKR A SPKR B
OFF OFF OFF YELP 1 YELP 1
OFF OFF ON YELP 2 YELP 2
OFF ON OFF YELP 1 YELP 2
OFF ON ON YELP 1 ALERT A
ON OFF OFF YELP 1 PIERCER
ON OFF ON YELP 1 HiLo
ON ON OFF YELP 2 SUPER HiLo
ON ON ON YELP 2 PIERCER
YELP BUTTON
BUTTON #5BUTTON #6BUTTON #7BUTTON #8SPKR A SPKR B
OFF OFF OFF OFF TONE
SCROLL*
TONE
SCROLL*
OFF OFF OFF ON PIERCER PIERCER
OFF OFF ON OFF HiLo HiLo
OFF OFF ON ON SUPER HiLo SUPER HiLo
OFF ON OFF OFF ALERT A ALERT A
OFF ON OFF ON ALERT A HiLo
OFF ON ON OFF ALERT A SUPER HiLo
OFF ON ON ON HiLo SUPER HiLo
ON OFF OFF OFF HiLo PIERCER
ON OFF OFF ON ALERT A ALERT B
ON OFF ON OFF PIERCER ALERT B
ON OFF ON ON PIERCER ALERT A
ON ON OFF OFF SUPER HiLo PIERCER
ON ON OFF ON WAIL 1 WAIL 2
ON ON ON OFF YELP 1 YELP 2
ON ON ON ON WAIL 1 YELP 1
TONE BUTTON
BUTTON #5BUTTON #6BUTTON #7BUTTON #8SPKR A SPKR B
OFF OFF OFF OFF HORN 1 HORN 1
OFF OFF OFF ON HORN 2 HORN 2
OFF OFF ON OFF HORN 3 HORN 3
OFF OFF ON ON HORN 4 HORN 4
OFF ON OFF OFF HORN 1 HORN 2
OFF ON OFF ON HORN 1 HORN 3
OFF ON ON OFF HORN 1 HORN 4
OFF ON ON ON HORN 2 HORN 3
ON OFF OFF OFF HORN 2 HORN 4
ON OFF OFF ON HORN 3 HORN 4
ON OFF ON OFF HORN 1 WAIL 1
ON OFF ON ON HORN 1 YELP 1
ON ON OFF OFF HORN 1 PIERCER
ON ON OFF ON HORN 2 YELP 1
ON ON ON OFF HORN 3 YELP 1
ON ON ON ON HORN 4 SUPER
HiLo
HORN BUTTON
BUTTON #6BUTTON #7BUTTON
#8
SPKR A/B
OFF OFF OFF WAIL 1
FREQUENCY DECREASE WHEN
RELEASED
OFF OFF ON WAIL 1
IMMEDIATE OFF WHEN RELEASED
OFF ON OFF YELP 1
OFF ON ON PIERCER
ON OFF OFF ALERT A
ON OFF ON HiLo
ON ON OFF SUPER HiLo
ON ON ON WAIL 1
IMMEDIATE OFF WHEN RELEASED
MANUAL BUTTON
AUXILLARY BUTTON TO SLIDE SWITCH MAPPING:
1. Press buttons 4 and 5 for 2 seconds until Radio Rebroadcast light flashes
2. Move slide switch to desired position
3. Press buttons 1-8 as required. LED ON = function will turn ON when level is activated
4. If automatic tone control is required, press wail, yelp, or tone button for the levels where required
5. Button to be programmed must be set up to be TOGGLE or TIME DELAY function. If it is programmed for Arrow, or mo­mentary, it can’t be selected for this feature
6. Press Radio Rebroadcast button to exit programming mode
TONE PROGRAMMING:
1. Press buttons 2 and 7 for 2 seconds until Slide switch LED’S 1,2, and 3 flash
2. Press tone button to be programmed (Wail, Yelp, Tone, Manual, or Horn). Auxillary button 1 = HORN, button 2 = MANUAL
3. Auxillary buttons 5-8 will determine which tone is to be played when the user presses the button.
4. Repeat steps 2 and 3 for each tone button
5. Press Radio Rebroadcast button to exit programming mode
Denotes Factory Default Setting
SPKR A SPKR B
WAIL 1 WAIL 2
WAIL 2 YELP 1
YELP 1 YELP 2
YELP 2 PIERCER
PIERCER ALERT A
ALERT A WAIL 1
*CYCLE TONE
Page 6
MICROPHONE BRACKET INSTALLATION:
A metal clip is provided for mounting the microphone. Choose a loca­tion convenient to the operator and away from any air bag deploy­ment areas. Using the mounting clip as a template, mark the two holes to be drilled. Using a 1/8” drill bit, drill the two mounting holes. Install the two #6 screws provided with the bracket.
: Microphone PSRNMC02 : Control Panel PSRNCTRL1 : Amplifier Filter PSRNFLT1
Replacement Parts & Accessories:
STANDBY SPKR 1 INDICATOR SPKR 2 INDICATOR CONDITION
FLASHING ON ON OVER-TEMPERATURE
FLASHING OFF ON UNDER-VOLTAGE
FLASHING ON OFF OVER-VOLTAGE
FLASHING FLASHING - COMM FAULT - RELAY
FLASHING - FLASHING COMM FAULT - AMP
FLASHING FLASHING FLASHING COMM FAULT -RELAY AND AMP
OFF - - STANDBY MODE
ON ON - SPKR 1 IS ACTIVE
ON - ON SPKR 2 IS ACTIVE
ON FLASHING - SPKR 1 FAULT
ON OFF - SPKR 1 IS NON-FUNCTIONING
ON - OFF SPKR 2 IS NON-FUNCTIONING
SIREN AMPLIFIER DIAGNOSTIC INDICATORS:
380 SERIES REMOTE SIREN
ETSA380R
LED INDICATOR CONDITION
OFF RELAY OUTPUT IS OFF
ON RELAY OUTPUT IS ON
FLASHING RELAY OUTPUT HAS A FAULT
AUXILLARY AND SLIDE SWITCH LED INDICATORS:
ETSA380R 4.12
TECHNICAL SPECIFICATIONS
Overall Dimensions:
Control Panel:
Amplifier/Relay:
6.89”H x 3.51”W x 1.17”D
8.67”H x 5.66”W x 2.66”D
Input Voltage: 10 - 30Vdc (negative ground)
Input Current:
9 Amps @ 13.5 VDC (100W
Speaker)/18 Amps @ 13.5Vdc
(200W Speaker)
Standby Current:
Ignition ON:
Ignition OFF:
500mA
<20mA
Audio Frequency:
200Hz - 10 kHz + 3db
Output Power
:
2x100W RMS MAX. (11 Ohm
Speaker Impedance)
Siren Frequency:
675Hz - 1633Hz
High Voltage
Protection:
Limits to 32V in Maximum
Low Voltage Shutdown: Voltage <9.0V will cause siren
output to cease and will resume
when system voltage is >9.0V
Operating Temperature: -40°C to +50°C
Auxiliary Input connection for remote
manual or Hands Free operation
Tone disable for California Title 13
compliance
Boxed Weight: 8 lbs
Loading...