WARRANTY
SoundOff Signal warranties the Directional Arrow Switch for 1 (one) full year from the date of purchase to the original purchaser against any manufacturer defects or workmanship. This warranty applies only to units installed according to manufacturer's installation instructions and operated within the units specifications. Warranty is void if the unit was installed incorrectly or maliciously damaged. All warranty claims must be accompanied by a dated proof of purchase. SoundOff Signal retains the right to be the sole mediator of what constitutes defects in Performance or manufacturing.
ETSWDAS01 -
DIRECTIONAL ARROW SWITCH
INSTALLATION & OPERATION
INSTRUCTIONS
ETSWDAS01 9.07
DIRECTIONAL ARROW SWITCH
Pin # Wi re Color Function
1 Red +10-30 Vdc Power Input 2 White / Red Master / Ignition switch (0u = Stand by) 3 Bla ck (-) Ground 4 NA Not populat ed
Pin # Wi re Color Function (Al l O ut puts + Vdc A ctive High)
1 Blue LEFT Arrow Indicator Output Cont rol 2 Brown CENTER A rro w i nd i cato r Ou tput Con trol 3 Green RIGHT Arrow Indicat or Output Cont rol 4 Yellow W A RNING 1 Ou tput Co ntrol 5 Pink W A RNING 2 Ou tput Co ntrol 6 Red/Black Power Control Output to External Relay for Predator Bar
CN1 (2x 2, Power Input Connector)
CN2 (2x 3, Contro l O utput Co nne ctor, Low Current: 0.25A M a x)*
Input Voltage: +10-30 Vdc Polarity: Negative Ground Reverse Polarity Protection: Yes Transient Protection: Yes Operating Temperature: -40C to +85C Current Draw: 0.8 Amps Standby Current: Zero Amps +Vin Fuse: 5 Amps ATO
Dimensions 166mm x 22mm x 45mm (6.55" x 0.88" x 1.76")
170 mm (6.7") w/ Mounting Bracket
Shipping Weight .65 lbs
Electrical
Mechanical
PAGE 1
DIRECTIONAL ARROW SWITCH
PAGE 14
PRODUCT SPECIFICATIONS
WIRE COLORS/USES
NOTES:
* Must NOT exceed a total of 0.25 Amp for any combination of active outputs.
DIRECTIONAL ARROW SWITCH
PAGE 13
DIRECTIONAL ARROW SWITCH
PAGE 2
NOTES:
CONNECTING THE WIRES:
Black Wire (Ground)
Connect to Reliable Ground  To minimize field service issues, it is recommended that the ground wires be
connected directly to the ground terminal of the battery. Red Wire (Power Input)
Connect to a reliable +12v or +24v power source White / Red Wire (Master / Ignition switch)
Connect to a reliable +12v or +24v power source
Wire Color Function Connection Black Ground Reliable Ground Red Constant power +12v or +24v White w/ Red Switch Master/Ignition switch
+12Vdc
+12Vdc
RED
WHITE/RED
BLACK
For the remaining wires, see the specific instructions listed below with page numbers to distinguish which method best suits your application.
ETL 5000 with 4 - wire Arrow Controller Option ...................................................................pg. 3
LED Traffic Master ETTMLEDW3(x) .....................................................................................pg. 4
Predator Warning Bar EPRD4MD0(x), EPRD6MD0(x) or EPRD8MD0(x).............................pg. 5
Integrating DAS w/ETL 5000 & 300 Series Siren System......................................................pg. 6
LED ULTRA-LITE (EL3H08A10(x), E3H12A10(x) or (E3H12A20(x)).....................................pg. 7
Loading...
+ 5 hidden pages