All rights reserved. Parts of the design of this product may be patented.
Soundcraft is a trading division of Harman International Industries Ltd. Information in this manual is subject
to change without notice and does not represent a commitment on the part of the vendor. Soundcraft shall
®
not be liable for any loss or damage whatsoever arising from the use of information or any error contained in
this manual.
No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any
means, electronic, electrical, mechanical, optical, chemical, including photocopying and recording, for any
purpose without the express written permission of Soundcraft.
Harman International Industries Limited
http://www.soundcraft.com
2
CONTENTS
Soundcraft Mini Stagebox 32i User/Installation Guide 0514
INTRODUCTION
SAFETY NOTICES
SAFETY SYMBOL GUIDE
IMPORTANT SAFETY WARNINGS
ELECTROSTATIC DISCHARGE (ESD)
IMPORTANT SAFETY INSTRUCTIONS
WORKING SAFELY WITH SOUND
FEATURES 9
MINI STAGEBOX FRONT PANEL 10
MINI STAGEBOX REAR PANEL 10
MOUNTING MINI STAGEBOX 11
MADI LINK 11
CONNECTING IT UP 12
MINI STAGEBOX CONNECTING TO Vi CONSOLE RANGE
CONSOLES MINI STAGEBOX CONNECTING TO Si OR Vi1
CONSOLES MINI STAGEBOX CONNECTING TO TWO CONSOLES
SPECIFICATIONS 15
4
4
4
5
6
7
8
12
13
14
WARRANTY 17
3
Soundcraft Mini Stagebox 32 User/Installation Guide 0514
INTRODUCTION
SAFETY NOTICES
For updated safety and certification information, go to: http://
www.soundcraft.com/safetyandcertifications.
FOR YOUR OWN SAFETY AND TO AVOID INVALIDATION OF THE
WARRANTY PLEASE READ THIS SECTION CAREFULLY.
SAFETY SYMBOL GUIDE
For your own safety and to avoid invalidation of the warranty all text marked
with these symbols should be read carefully.
WARNINGS
The lightning flash with arrowhead symbol is intended to alert the
user to the presence of un-insulated “dangerous voltage” within
the product’s enclosure that may be of sufcient magnitude to
constitute a risk of electric shock to persons.
CAUTIONS
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
4
NOTES
These notes contain important information and useful tips on
the operation of your equipment.
HEADPHONES SAFETY WARNING
These notes contain important information and
useful tips on headphone outputs and monitoring
levels.
ESD WARNING
The crossed-out hand symbol is intended to alert the user to
devices sensitive to electrostatic discharge. Please refer to the
instructions on page 6.
IMPORTANT SAFETY WARNINGS
Soundcraft Mini Stagebox 32i User/Installation Guide 0514
THIS APPARATUS MUST BE EARTHED. Under no circumstances should the safety
earth be disconnected from the mains lead.
The mains supply disconnect device is the mains plug. It must remain accessible so as
to be readily operable when the apparatus is in use.
If any part of the mains cord set is damaged, the complete cord set should be
replaced. The following information is for reference only.
The wires in the mains lead are coloured in accordance with the following code:
As the colours of the wires in the mains lead may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
Earth (Ground): Green and Yellow (US - Green/Yellow)
Neutral: Blue (US - White)
Live (Hot): Brown (US - Black)
The wire which is coloured Green and Yellow must be connected to the terminal
in the plug which is marked with the letter E or by the earth symbol.
The wire which is coloured Blue must be connected to the terminal in the plug
which is marked with the letter N.
The wire which is coloured Brown must be connected to the terminal in the plug
which is marked with the letter L.
Ensure that these colour codes are followed carefully in the event of the plug being
changed.
This unit is capable of operating over a range of mains voltages as marked on the rear panel.
The internal power supply unit contains no user serviceable parts. Refer all servicing
to a qualied service engineer, through the appropriate Soundcraft dealer.
5
Soundcraft Mini Stagebox 32i User/Installation Guide 0514
ELECTROSTATIC DISCHARGE (ESD)
Many semiconductor components are sensitive to electrostatic discharge (ESD).
The lifespan of assemblies contain ing such components can be drastically reduced
by improper handling during maintenance and repair. Please observe the following
rules when handling ESD sensitive components:
•ESD sensitive components should only be stored and transported in the
packing material specifically provided for this purpose.
•When performing a repair by replacing complete assemblies, the removed
assembly must be sent back to the supplier in the same packing material in
which the replacement assembly was shipped. If this should not be the case,
any claim for a possible refund will be null and void.
•Unpacked ESD sensitive components should only be handled in ESD protected
areas (EPA, e.g. area for field service, repair or service bench) and only be
touched by persons wearing a wrist band connected to the ground potential of
the repair or service bench by a series resistor. The equipment to be repaired or
serviced as well as all tools and electrically semi-conducting work, storage, and
floor mats should also be connected to this ground potential.
•The terminals of ESD sensitive components must not come in uncontrolled
contact with electro statically chargeable or metallic surfaces that would result
in a puncture voltage and a discharge shock hazard.
•To prevent the components from undefined transient stress and possible
damage due to inadmissible voltages or compensation currents, electrical
connections should only be established or separated when the equipment is
switched off and after any capacitor charges have decayed.