Go/No Go Test Script Specification, HVC
Go/No Go Test Script Specification, HVC
Applicable for V800/V802SE
Applicable for K700i
Contents
General............................................................................................................................. 2
1
1.1 About this document..........................................................................................2
1.2 Requirements.....................................................................................................2
1.3 General definitions ............................................................................................4
1.4 Test conditions...................................................................................................5
1.5 Scripts................................................................................................................5
2 Test sequence GSM.........................................................................................................6
2.1 INITIALISING and call setup...........................................................................6
2.2 Measurement group ALLMEAS HCH 1900.....................................................7
2.3 Measurement group ALLMEAS MCH 1900 .................................................... 7
2.4 Measurement group ALLMEAS LCH 1900 .....................................................8
2.5 Measurement group ALLMEAS LCH 1800 .....................................................8
2.6 Measurement group ALLMEAS MCH 1800 .................................................... 9
2.7 Measurement group ALLMEAS HCH 1800.....................................................9
2.8 Measurement group ALLMEAS HCH 900.....................................................10
2.9 Measurement group ALLMEAS LCH 900 .....................................................10
2.10 Measurement group ALLMEAS MCH 900 ....................................................11
2.11 Call Termination.............................................................................................. 11
3 Test sequence WCDMA ...............................................................................................12
3.1 Procedure proposal ..........................................................................................12
3.2 Sequence in Instrument Script/MMI proposal................................................. 12
3.3 Measurement group WCDMA ........................................................................13
4 Attenuation factors for Sony Ericsson V802SE .........................................................14
4.1 Attenuation factors for Rohde&Schwarz antenna coupler use........................14
4.2 Attenuation factors for RF-holder use .............................................................15
5 Revision history.............................................................................................................16
2/1524-2/FEA 209 544/83 B
Sony Ericsson Mobile Communications AB
Approved according to 000 21-LXE 107 42/1
Go/No Go Test Script Specification, HVC
1 General
1.1 About this document
This document contains the test requirements for theWCDMA/Triband GSM (E-GSM900,
GSM1800, GSM1900) pocket transceiver using antenna coupler or direct line connection.
This test should be used as an arrival and verification test radio functionality.
Tests are done in signalling mode, i.e a call has been established to the test instrument. The
testinstrument controls the transceiver unit. RF Performance is measured with an antenna
coupler or direct line connection, whichever method is selected.
1.2 Requirements
1. The test should be designed so those users with little or no system expertise can perform
accurate testing.
2. The measurements should run automatically, though a certain amount of manual work is
included (and mandatory), such as call setup (i.e. dialling number).
3. It should be possible to print or store the measurement results.
4. It should be possible to change the channels used in testing due to possible local radio
interference. The range for these settings is specified under 1.3.1General definitions.
5. All functions and should be protected in such a manner that the end-user cannot directly
change them. (For example, a password or encrypted settings file.)
6. The attenuation factors that should be used are stated in section 5. The test instrument
must be capable of using different attenuation factors for RX and TX. It must also be
possible to use various attenuation factors for different channels in each band.
2/1524-2/FEA 209 544/83 B
Sony Ericsson Mobile Communications AB
2(16)
Go/No Go Test Script Specification, HVC
Parameter:
Possible to change:
Attenuation factors Yes *
Channel allocations table Yes, within specified range *
Powerlevel allocation table No
Measurement flow No
Measurement limits No
* All functions and settings should be protected in such manner that the end-user
cannot directly change them. (For example a password or an encrypted settings file.)
Note! Any setups other than the one stated in this document must be discussed
and exempted by SonyEricsson to be approved.
2/1524-2/FEA 209 544/83 B
Sony Ericsson Mobile Communications AB
3(16)
Go/No Go Test Script Specification, HVC
1.3 General definitions
1.3.1 Channel allocation table
Band Ch definition Any ARFCN of:
E-GSM900 Low 975-979
E-GSM900 Mid 34-38
E-GSM900 High 120-124
GSM1800 Low 512-516
GSM1800 Mid 698-702
GSM1800 High 881-885
GSM1900 Low 512-516
GSM1900 Mid 658-662
GSM1900 High 806-810
WCDMA Low 10562
WCDMA Mid 10700
WCDMA High 10838
1.3.2 Power level allocation table GSM
Band PL definition Powerlevel (PL)
E-GSM900 Low 19
E-GSM900 Mid 12
E-GSM900 High 5
GSM1800/1900 Low 15
GSM1800/1900 Mid 8
GSM1800/1900 High 0
1.3.3 Test limits
The test limits for each measurement is specified in the Sequence tables.
1. Since the coupler introduces higher measurement inaccuracy, some measurements may
have wider limits than stated in the GSM specifications.
2. The direct line connection limits conform to the phase 2 GSM specification and the 3GPP
specifications.
2/1524-2/FEA 209 544/83 B
Sony Ericsson Mobile Communications AB
4(16)
Go/No Go Test Script Specification, HVC
1.4 Test conditions
1.4.1 General
Attenuation factors
The different scripts must be configured with the correct attenuation factors and named after
the product that it is designed to test. The attenuation factors to be used are stated in chapter
4.
1.5 Scripts
General scripts for the different system/system combinations may be developed. No handover
is necessary if not stated, however, SonyEricsson mobile phones are capable with handover
between E-GSM900/1800 and might therefore be used in order to decrease test time. Possible
system/system combinations are listed below:
1.5.1 Script types
WCDMA
E-GSM900
GSM1800
GSM1900
E-GSM900/GSM1800
WCDMA/E-GSM900/GSM1800/GSM1900
2/1524-2/FEA 209 544/83 B
Sony Ericsson Mobile Communications AB
5(16)