Sony SRP-X700P User Manual 4

SRP-X700P Manager User Control Panel
Operating Instructions (Control Software Manual Ver. 1.1) Before using the software, please read this manual and the Operating Instructions of the Digital Powered Mixer (main unit) thoroughly and retain it for future reference.
SRP-X700P
2002 Sony Corporation

Table of Contents

Features ........................................................................................................................... 3
Precautions ...................................................................................................................... 3
About This Manual......................................................................................................... 3
Installation....................................................................................................................... 4
Installing the Dedicated USB Driver Software.......................................................... 4
Installing the SRP-X700P Manager........................................................................... 5
Installing the User Control Panel...............................................................................5
Uninstalling ..................................................................................................................... 5
Section 1 SRP-X700P Manager .................................................................................... 6
Names and Functions of Controls on Screen.............................................................6
Common operation section ........................................................................................6
Menu bar ............................................................................................................. 6
Bottom menu bar ................................................................................................. 7
BLOCK Screen .......................................................................................................... 8
INPUT Screen............................................................................................................9
INPUT OVERVIEW Screen ............................................................................... 9
INPUT EQ Screen ............................................................................................. 11
ROUTING Screen.................................................................................................... 13
OUTPUT Screen......................................................................................................14
OUTPUT OVERVIEW Screen ......................................................................... 14
OUTPUT EQ Screen ......................................................................................... 16
REMOTE Screen .....................................................................................................17
USER DEFINE Screen...................................................................................... 20
GROUP FADER Screen .......................................................................................... 26
SCENE Screen ......................................................................................................... 27
Section 2 User Control Panel......................................................................................28
Names and Functions of Controls on Screen...........................................................28
Troubleshooting ............................................................................................................ 29
........................................................................................................................................................................................................................................
• Microsoft® and Windows® are registered trademarks of U.S. Microsoft Corporation in the U.S. and other countries.
2

Features

The CD-ROM supplied with the SRP-X700P contains two applications and the driver software. By installing the software in a personal computer running Windows, you can set the parameters of the SRP-X700P and can perform from the PC the basic operations of the SRP-X700P. Similarly, you can also operate a Sony DVD, VCR or CD/MD that is connected to the SRP-X700P.
SRP-X700P Manager
The SRP-X700P Manager enables you to set all the functions of the SRP-X700P. You can set all functions of the SRP-X700P including making various settings in accordance with the operating environment and peripheral equipment, can use of a maximum of 20 scene memories, can save the setup files, and so forth.
User Control Panel
From the User Control Panel, you can control the basic operations (sound volume adjustment, input selection and scene recall) of the SRP-X700P and also the basic operations (playback, stop, fast forward, rewind, etc.) of other Sony products (DVD, VCR, CD/ MD) connected to the SRP-X700P, all from a personal computer.

Precautions

• The recommended operating environment for using this software is as follows. Operating systems:
Microsoft® Windows® 98 Second Edition Microsoft® Windows® Millennium Edition Microsoft® Windows® 2000 Professional Microsoft® Windows® XP Professional *
Microsoft® Windows® XP Home Edition * Operation of this software when the OS has been upgraded is not guaranteed.
* Simple switching of desktop and user cannot be implemented.
CPU: Celeron 400 MHz or higher Memory: 128 MB or more Hard disk free space: 10 MB or more
• USB terminal should be equipped as standard.
• This software may not operate appropriately depending on the USB equipment and hub used simultaneously by your computer. Be sure to use the USB equipment and hub conforming to the USB 2.0 standard.
• Operation this software is not guaranteed in every personal computer, even if the recommended environment is satisfied.
• Use the USB cable conforming to USB 2.0 to connect to the SRP-X700P. If any cable other than the USB cable conforming to USB 2.0 is used, the software may not work properly.
• When the FADER select of the SRP-X700P Manager is switched to ACTIVE for the first time, adjust the sound volume to the appropriate level by controlling the INPUT fader and the OUTPUT fader. (Refer to pages 10 and 15.) If the sound volume is not adjusted, the INPUT faders are all
automatically and the system enters the state in
set to which no sound is output.
• While you are using the SRP-X700P Manager and the User Control Panel, your computer must not enter the System Standby or System Hibernate state. Therefore, be sure to select “Power Options” from the “Control Panel” and select “Never” in the System Standby tab and in the System Hibernate tab.
• If your computer enters the System Standby or System Hibernate state while the SRP-X700P Digital Powered Mixer is connected and these software are in use, communication between them will be interrupted and the software must be started again.
• The specifications of this software are subject to change without notice due to improvement.
• The actual screens of the application software may appear differently from those printed in these Operating Instructions.

About This Manual

This manual describes operations of the SRP-X700P when it is used via a personal computer. Section 1 describes how to set the parameters using the SRP-X700P Manager. Section 2 describes how to operate the SRP-X700P from the User Control Panel and Sony products connected to the SRP-X700P. Read this manual together with the Operating Instructions of the respective Sony products.
3

Installation

The dedicated USB driver software is necessary to connect the SRP-X700P Manager and User Control Panel to the SRP-X700P.

Installing the Dedicated USB Driver Software

The dedicated USB driver software is contained in the CD-ROM supplied with the SRP-X700P.
Install the dedicated USB driver software by following the instructions shown on the screen. Some computer may reboot when the dedicated USB driver software is installed.
1 Turn on the main power of the personal computer and start
Windows.
2 Insert the supplied CD-ROM into the CD-ROM drive of the
personal computer.
3 Turn on the main power of the SRP-X700P. Connect the
connector on the front or rear of the SRP-X700P to the USB connector of the personal computer using a USB cable.
4 The USB device of the SRP-X700P is recognized and the
dialog box [This wizard searches for new drivers for:] appears. Click [Next >].
5 Select [Search for the best driver for your device.
(Recommended).] and click [Next >]. (Fig. 1)
0 Select [Search for the best driver for your device.
(Recommended).] and click [Next >]. (Fig. 3)
Select
Click
Fig. 3
qa Click on the check box [Specify a location:] and click
[Browse...]. Specify [Driver] folder of the supplied CD-ROM and click [Next >]. (Fig. 4)
Click on the check box
Select
Click
Fig. 1
6 Click on the check box [Specify a location:] and click
[Browse...]. Specify [Driver] folder of the supplied CD-ROM and click [Next >]. (Fig. 2)
Click on the check box
Click
Fig. 2
Click
Fig. 4
qs When the screen [Windows driver file search for the device:]
appears, click [Next >].
qd When the screen [Windows has finished installing the software
that your new hardware device requires.] appears, click [Finish].
Installation of the dedicated USB driver software is now complete.
7 When the screen [Windows driver file search for the device:]
appears, click [Next >].
8 When the screen [Windows has finished installing the software
that your new hardware device requires.] appears, click [Finish].
9 Because the USB port of the SRP-X700P is recognized as
[Unknown Device], click [Next >].
4

Installing the SRP-X700P Manager

1 Insert the supplied CD-ROM into the CD-ROM drive of the
personal computer. Open the SRP-X700P Manager folder. Double-click the Setup icon.
2 The SRP-X700P Manager installation screen appears. 3 When the screen [Welcome to the SRP-X700P Manager
installation program] appears, click OK.
4 When the screen [Begin the installation by clicking the button
below] appears, click the Setup icon on the top left of the screen. (Fig. 1)
Fig. 1 Fig. 2
The SRP-X700P Manager folder is created in C:\Program Files. To change the installation destination, click Change Directory on the bottom right of the screen.
5 When the screen [Setup will add items to the group shown in
the Program Group box. You can enter a new group name or select one from the Existing Groups LIST] appears, click Continue on the bottom left of the screen.
6 When the screen [SRP-X700P Manager Setup was completed
successfully] appears, click OK.

Installing the User Control Panel

1 Insert the supplied CD-ROM into the CD-ROM drive of the
personal computer. Open the SRP-X700P Control folder. Double-click the Setup icon.
2 The User Control Panel installation screen appears. 3 When the screen [Welcome to the User Control Panel
installation program] appears, click OK.
4 When the screen [Begin the installation by clicking the button
below] appears, click the Setup icon on the top left of the screen. (Fig. 2)
The SRP-X700P Control folder is created in C:\Program Files. To change the installation destination, click Change Directory on the bottom right of the screen.
5 When the screen [Setup will add items to the group shown in
the Program Group box. You can enter a new group name or select one from the Existing Groups LIST] appears, click Continue on the bottom left of the screen.
6 When the screen [User Control Panel Setup was completed
successfully] appears, click OK.
Installation of the SRP-X700P Manager is now complete.
Installation of the User Control Panel is now completed.

Uninstalling

1 Click the Start menu and select [Settings (S)]. Then click the
[Control Panel] to open it.
2 Double-click the [Add/Remove Programs] icon and select the
application “SRP-X700P Manager” or “User Control Panel” and the driver software “SRP-X700P USB Driver that you want to delete from the list of the [Install/Uninstall] tab.
3 Click [Add/Remove (R)...].
This completes the uninstallation.
Note
When using Microsoft Windows® XP Professional or Microsoft® Windows® XP Home Edition, be sure to log on as the user having administrator authority, then perform the installation or uninstallation.
®
Windows® 2000 Professional, Microsoft
®
5

Section 1 SRP-X700P Manager

The SRP-X700P Manager enables you to set all parameters of the SRP-X700P.
Starting the SRP-X700P Manager
If the SRP-X700P Manager is started after connecting the SRP-X700P to the personal computer with a USB cable, the present setup of the SRP-X700P is read. If the SRP-X700P Manager is started before connecting the SRP-X700P to the personal computer, the default setup of the SRP-X700P when shipped from the factory is read. If the SRP-X700P Manager is started by double-clicking the existing setup file (*.x7p), the status stored in the existing setup file is sent to the SRP-X700P. The screen images that are used in this manual are all default settings when shipped from the factory.

Names and Functions of Controls on Screen

Common operation section

The controls shown below appear on all the screens.
1 3
4
5
2

1 Menu bar

The titles of the menu are displayed. You can perform operations that are common to the basic settings and each setup screen.
File menu
This software allows you to save the parameters of up to 20 scenes and the information in a single setup file (*.x7p).
New: Creates a new setup file.
The new setup file contains the default settings when
shipped from the factory. Open: Opens an existing setup file. Open Scene: Opens the specified scene number from the 20
scenes in the existing setup file.
2
6
1
5
3 4
Specify a setup file. 1
The information that is set in the specified setup file is
displayed. 2
Specify the scene number. 3
The index of the specified scene number is displayed. 4
Click the Open button. 5
Save: Saves the new data by overwriting the existing data. Save As: Saves the data under a different name. Exit: Exits the SRP-X700P Manager.
About Compatibility of Setup File
The setup file that is saved by the SRP-X700P Manager version
1.1 cannot be used by the SRP-X700P Manager version 1.0 because it does not support the downward compatibility. Please upgrade the SRP-X700P Manager to version 1.1. Note that the setup file that is saved by the SRP-X700P Manager version 1.0 can be used by the SRP-X700P Manager version 1.1.
Edit menu (Displayed only on the INPUT and OUTPUT screens)
Copy: Copies the parameters.

2 Bottom menu bar

You can select the setup screen for each parameter. For the INPUT and OUTPUT buttons, submenus are displayed.
1
3
You can copy the parameters of the desired channel to the specified channel. Use this function when you want to use multiple channels with the same setup. However, you cannot copy the parameters of index, TRIM (INPUT), feedback reducer (INPUT) and REF LEVEL (OUTPUT).
Select the copy source channel. 1
Click the check box of the copy destination channel. 2
Press OK. 3
2
Communication menu
Disconnect: Disconnects communication with the SRP-X700P.
Connect: You can select the connection method on the dialog box.
Download: Sends the parameters of the SRP-X700P to
SRP-X700P Manager.
Upload: Sends the parameters that are set by using
SRP-X700P Manager to the SRP-X700P.
Options menu
Password Setting: You can set a password.
3 FRONT PANEL LOCK button
You can lock the FRONT PANEL so that the buttons and faders on the SRP-X700P front panel are disabled to prevent accidental operation. When locked, the FRONT PANEL LOCK button lights in red, and the LOCK indicator on the front of the SRP-X700P also lights in red.
4 CONNECTION indicator
The CONNECTION indicator lights in green while communication with the SRP-X700P is in progress.
5 RETURN button
You can return to the previous screen that was selected immediately before.
How to set a password
The [Password Setup] dialog box appears. Enter the password in the Password field. For confirmation, enter the same password again in the [Confirm password] field and click OK. The password can be up to 8 alphanumeric characters.
Note
If you forget the password, you cannot start the system next time, so take a note of the password and keep it safely. If you forget the password, uninstall the SRP-X700P Manager and then reinstall it.
Factory Preset: Resets all parameters to the default settings.
Note
Be careful that the system cannot be returned to your own settings after resetting it to the default settings.
Help menu
About: You can confirm information about the version.
7
Names and Functions of Controls on Screen

1.1 BLOCK Screen

The BLOCK screen displays the setup status and the signal level according to the internal blocks in the SRP-X700P.
If you click a button, the screen jumps to the related setup screen. You can select ON/OFF and set parameters on each screen.
43 56 78 9 qa qd qfqg qh qj qk
2
w;
1
0qlqs
1 INPUT index
You can enter an index of each input channel. By entering the name of the connected equipment as the index, you can easily check the signal system when setting the parameters. You can enter up to 8 alphanumeric characters.
2 TRIM button
The reference level of each input channel that is set on the INPUT OVERVIEW screen appears on the TRIM buttons.
3 Input level meter
Displays the input signal level of each input channel.
4 LCF (Low-Cut Filter) button
When you turn on the LCF button, it lights in green.
5 PEQ (Parametric EQualizer) button
When you turn on the PEQ button, it lights in green.
6 FR (Feedback Reducer) button
When you turn on the FR button, it lights in green.
7 COMP (Compressor) button
When you turn on the COMP button, it lights in green.
8 INPUT fader display
Displays the setup value of the INPUT fader.
9 INPUT MUTING button
The INPUT MUTING button lights in red when muted.
0 INPUT VIDEO TYPE display
Displays the video input signal format of A to F of LINE4.
qa Setup.. button
The screen jumps to the ROUTING screen when this button is pressed.
ws
wa
qs AUTOMATIC MIXER button
The AUTOMATIC MIXER button lights in green while the AUTOMATIC MIXER is in operation.
qd OUTPUT MUTING button
The OUTPUT MUTING button lights in red when muted.
qf OUTPUT fader display
Displays the setup value of the OUTPUT fader.
qg EQ (EQualizer) button
When you turn on the EQ button, it lights in green.
qh DELAY button
When you turn on the DELAY button, it lights in green.
qj Output level meter
Displays the output signal level of each output channel.
qk REF LEVEL button
Displays the reference level of each output channel on the button that is set on the OUTPUT OVERVIEW screen.
ql ATT (ATTenuator) button
Displays the output ATT level to the internal power amplifier.
w; OUTPUT index
You can enter an index of each output channel. You can enter up to 8 alphanumeric characters.
wa CLIP indicator
The CLIP indicator lights in red when the internal power amplifier starts clipping. Adjust the output level using wf AT T so that the CLIP indicator does not turn on frequently.
ws PROTECTION indicator
The PROTECTION indicator lights in red when the power amplifier protection circuit operates.
8

1.2 INPUT Screen

You can set parameters of the input block of the SRP-X700P from the INPUT screen.

1.2.1 INPUT OVERVIEW Screen

This screen corresponds to the input module of the audio mixer. This screen enables you to set the following.
qh
qk
1
2
8 9
qa
qf qd
45
3
6
7 q;
qs
qj
qg
1 INPUT index
Displays the index that is input on the BLOCK screen.
2 INPUT level meter
Displays the input signal level after the TRIM adjustment is complete with the VU response.
3 +48 V indicator
The +48 V indicator lights in red when the +48 V button on the rear of the SRP-X700P is turned on.
4 RF indicator
The RF indicator lights in green when the wireless tuner unit installed in the SRP-X700P receives the RF signal. As long as this indicator is on, this system selects the wireless tuner signal.
5 LINE indicator
The LINE indicator lights in green when the MIC/LINE select button on the rear of the SRP-X700P is set to the LINE position.
6 TRIM controls
The TRIM controls enable you to adjust the reference input level of each input channel. Each click of the [+] or [--] button increments or decrements the reference input level by 1 dB. The adjustment range of MIC1/ WL1, MIC2/WL2, MIC3 and MIC4 is –60 dBu to –45 dBu. The adjustment range of LINE3 and LINE4 is –10 dBu to 0 dBu. The adjustment range of MIC5/LINE1 and MIC6/LINE2 is –60 dBu to –45 dBu when MIC is selected or –10 dBu to +5 dBu when LINE is selected. You can also enter numerical values directly. It is recommended to adjust the TRIM controls so that 0 VU of the INPUT level meter lights often.
7 Setup.. button
By clicking the Setup button, the display jumps to the INPUT EQ screen where you can set the low-cut filter, feedback reducer and parametric equalizer.
8 LCF (Low-Cut Filter) button
Each press of this button toggles the low-cut filter between on and off. This button lights in green when pressed on. The LCF removes low-frequency components such as blowing noise and makes the sound clear.
9 PEQ (Parametric Equalizer) button
Each press of this button toggles the parametric equalizer between on and off. This button lights in green when pressed on. To set the PEQ, click on the 7 Setup.. button.
0 FR (Feedback Reducer) button
Each press of this button toggles the feedback reducer that is set on the INPUT EQ screen between on and off. This button lights in green when pressed on. To set the FR, click on the
7 Setup.. button.
qa COMP (Compressor) setup box
This function compresses the dynamic range of the input signal that affects the unity sound volume. The compressor can be set in three steps of SOFT, MID or HARD. When the AUTOMATIC MIXER is turned ON, the compressor is set automatically and the manual COMP setup is disabled.
qs MUTING button
Pressing this button mutes the input signal of each channel. The MUTING button lights in red when muted.
9
Loading...
+ 20 hidden pages