Sony SRP-P450 Users guide

Page 1
CONTENTS
2-347-074-11(1)
POWER AMPLIFIER
SRP-P450
Operating Instructions
Thank you for purchasing this Sony product. Please be sure to read this manual before using this product. After reading, keep the manual in a safe place for future reference.
Warning......................................
Main characteristics .................
Block diagram ...........................
Dimensions................................
Putting ATT guard to the unit ..
Main specifications...................
Troubleshooting guide ............
2
3 4 6 7 7 8 9
1999 by Sony Sound Tec Corporation
Page 2
Warning
English
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
• Operate the unit only on 230V AC, 50/60 Hz.
Notice for the Customers in the United Kingdom
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code: Blue: Neutral Brown: Live As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire which is coloured blue must be connected to the terminal which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. Do not connect either wire to the earth terminal in the plug which is marked by the letter E or by the safety earth symbol Y or coloured green or green-and-yellow.
Français
AVERTISSEMENT
Afin d’éviter tout risque d’incendie ou d’électrocution, ne pas exposer l’appareil à la pluie ou à l’humidité. Afin d’écarter tout risque d’électrocution, garder le coffret fermé. Ne confier l’entretien de l’appareil qu’à un personnel qualifié.
• Faites uniquement fonctionner cet appareil sur une tension de 230 V CA, 50/60 Hz.
Svenska
VARNING
Utsätt inte apparaten för regn och fukt för att undvika riskerna för brand och/eller elektriska stötar. Öppna inte höljet. Det kan resultera i risk för elektriska stötar. Överlåt allt reparations- och underhållsarbete till fackkunniga tekniker.
• Du kan endast driva apparaten med 230 V växelström, 50/60 Hz.
Italiano
ATTENZIONE
Per evitare il pericolo di incendi o scosse elettriche, l’apparecchio non deve essere esposto alla pioggia o all’umidià. Per evitare scosse elettriche, non aprire l’apparecchio. Per le riparazioni rivolgersi solo a personale qualificato.
• Far funzionare l’apparecchio con corrente alternata a 230 V, 50/60 Hz.
Norsk
ADVARSEL
For å hindre brann og støtfare må enhetens overflate ikke utsettes for regn eller fuktighet. For å unngå elektrisk støt må kassen ikke åpnes. Service må bare utføres av kvalifisert personell.
• Enheten må bare betjenes ved 230 V vekselstrøm, 50/60 Hz.
Suomi
VAROITUS
Español
ADVERTENCIA
Para evitar incendios o el riesgo de electrocución, no exponga la unidad a la lluvia ni a la humedad. Para evitar descargas eléctricas, no abra la caja. En caso de avería solicite los servicios de personal cualificado solamente.
• Alímente la unídad sólo con 230 V CA, 50/60 Hz.
Deutsch
VORSICHT
Um die Feuergefahr und die Gefahr eines elektrischen Schlages zu vermeiden, darf das Gerät weder Regen noch Feuchtigkeit ausgesetzt werden. Um einen elektrischen Schlag zu vermeiden, darf das Gehäuse nicht geöffnet werden. Überlassen Sie Wartungsarbeiten stets nur einem Fachmann.
• Betreiben Sie das Gerät ausschließlich an 230 V Wechselspannung, 50/60 Hz.
Nederlands
WAARSCHUWING
Stel het apparaat niet bloot aan regen of vocht, om gevaar van brand of een elektrische schok te voorkomen. Open niet de behuizing, om gevaar van elektrische shokken te vermijden. Laat reparatiles aan de erkende vakhandel over.
• Last dit toestel enkel werken op 230 V wisselstroom, 50/60 Hz.
2
Tulipalon ja iskuvaaran välttämiseksi ei laitetta saa altistaa sateelle ja kosteudelle. Sähköiskun välttämiseksi ei koteloa saa avata. Anna vain asiantuntijan suorittaa huolto.
• Laite käyttää 230 V:n vaihtovirtaa, jonka taajuus on 50/60 Hz.
Dansk
ADVARSEL
For at undgå faren for brand eller elektrisk stød må udstyret ikke udsættes for regn eller kraftig fugt. Åbn ikke kabinettet, da der er risiko for elektriske stød. Overlad alle reparationer til kvalificeret servicepersonale.
• Betjen kun enheden med 230 V veksetlstrøm, 50/60 Hz.
Português
ADVERTÊNCIA
Para evitar o risco de incêndio ou de choques eléctricos, não exponha o aparelho à chuva nem à humidade. Para evitar descargas eléctricas, não abra o aparelho. Peça assistência somente a técnicos especializados.
• O apparelho só deve ser utilizado com corrente de 230 V CA, 50/60 Hz.
Page 3
Table of contents
Precautions
For the customers in Europe
This product with the CE marking complies with both the EMC Directive(89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European standards:
•EN60065 :Product Safety
•EN55103-1:Electromagnetic Interference(Emission)
•EN55103-2:Electromagnetic Susceptibility(Immunity) This product is intended for use in the following Electromagnetic Environment(s): E1(residential),E2(commercial and light industrial),E3 (urban outdoors) and E4(controlled EMC environment ex. TV studio).
Peak inrush current
(1)Power ON,current probe method: 36A (240V) (2)Hot switching inrush current, measured in accordance with European standard EN55103-1: 36A (230V)
Pour les clients européens
Ce produit portant la marque CE est conforme à la fols à la Directive sur la compatibilité électromagnétique (EMC) (89/ 336/CEE) et à la Directive sur les basses tensions (73/23/ CEE) émises par la Commission de la Communauté européenne. La conformité à ces directives implique la conformité aux normes européennes suivantes:
•EN60065 :Sécurité des produits
•EN55103-1:Interférences électromagnétiques (émission)
•EN55103-2:Sensibilité électromagnétique (immunité) Ce produit est prévu pour être utilisé dans les environnements électromagnétiques suivants: E1(résidentiel),E2(commercial et lndustrie légère),E3 (urbain extérieur) et E4(environnement EMC contrôlé ex. studio de télévision).
Appel de courant de créte
(1)Mise sous tension (ON), méthode de sondago du courant: 36A (240V) (2)Mesuré conformément à la norme européenne EN55103-1: 36A (230V)
On safety
Should any liquid or solid object fall into the cabinet, unplug
the unit and have it checked by qualified personnel before operating it any further.
Unplug the unit from the wall outlet if it is not to be used for
an extended period of time. To disconnect the cord, pull it out by grasping the plug. Never pull the cord itself.
On installation
Do not install the unit in a location near heat sources such as
radiators or air ducts, or in a place subject to direct sunlight, excessive dust, mechanical vibration or shock.
When mounting the unit on the EIA 19-inch standard rack,
allow enough space of 1U or more above this unit for good ventilation.
Do not block fan intake or exhaust ports.
Do not install the unit in a completely enclosed rack.
Make certain that there is enough space around the rear of the
amplifier; the exhaust air must flow out without resistance.
On operation
Before making program source connections, be sure to turn
the power switch off and unplug the unit.
When the unit is not used, turn the power off to conserve
energy and to extend the useful life of your unit.
On cleaning the cabinet
Clean the cabinet, panel and controls with a soft cloth lightly moistened with mild detergent solution. Do not use any type of abrasive pad, scouring powder or solvent such as alcohol or benzine.
On repacking
Do not throw away the carton and the packing material. It makes an ideal container for transporting the unit. When shipping the unit for repair work or to another location, repack it as it was.
If you have any questions or problems concerning your unit, consult your nearest Sony dealer.
Main characteristcs
Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt sowohl die EMV-Direktive (89/336/EEC) als auch die Dilevtive Niederspannung (73/23/EEC) der EG-Kommission. Die Erfüllung dieser Direktiven bedeutet Konformität für die folgenden Europäischen Normen:
•EN60065 :Produktsicherheit
•EN55103-1:Elektromagnetische Interferenz(Emission)
•EN55103-2:Elektromagnetische Empfindlichkeit(Immunität) Dieses Produkt ist für den Einsatz unter folgenden elektromagnetischen Bedingungen ausgelegt: E1(Wohnbereich),E2(kommerzleller und in beschränktem Maße industrieller Bereich),E3(Stadtbereich im Freien) und E4(kontrollierter EMV-Bereich, z.B. Fernsehstudio).
Spitzenstrom
(1)Einschaltstrom, Stromsonde: 36A (240V) (2)Gemossen in EN55103-1: 36A (230V)
High power output of 1.4kw (at bridged mono)
High power output of 1.4kw is realized by the large Troidal Power Transformer of 2kVA and the efficient 2 speed cooling system. Capable of variable use for example as a theater system or a wide room application.
Studio Quality
Excellent separation of back ground sounds and the words. Forceful scenes can be reproduced effectively. It is possible to use in a post production studio.
ATT guard is supplied
Supplied ATT guard raises reliance of the system after adjusting the sounds.
Possible to mount 19 inches rack
3
Page 4
Names and functions
Front panel
CHANNEL 1(MONO)
CHANNEL 2
1 CLIP indicator 2 ATTENUATOR control
3 Vents 4 OVER HEAT indicator
5 PROTECTION indicator 6 SIGNAL indicator
7 MONO indicator 8 POWER Switch and Pilot Lamp
1 CLIP indicator (red)
It lights up when output signals are distorted. In this case, the input level is too high. Lower the system GAIN by adjusting the ATTENUATOR control 2.
2 ATTENUATOR control
From “0” (maximum) to “29” (–29dB down) in 1dB step.
CHANNEL 1 (MONO) position: This control adjusts the level of channel 1 of this unit. When the unit is used at monaural operation by BTL, this control is to be used.
CH-2CH-1
25
20
ATTENUATOR CH-1
15
dB
10
CLIP
OVER HEAT
5
PROTECTION
SIGNAL
2CHANNEL POWER AMPLIFIER SRP-P450
MONO
POWER
CLIP
OVER HEAT
PROTECTION
ON
SIGNAL
25
20
ATTENUATOR CH-2
15
10
5
dB
CHANNEL 1 and CHANNEL 2
equip with the same function.
5 PROTECTION (protection circuit) indicator
(red)
It lights up while the protection circuit is operateing. It also serves as the MUTING indicator at POWER ON.
6 SIGNAL indicator
It lights up when signals are input to the amplifier. It does not lights when the ATTENUATOR control is turned counterclockwise to the end () or when the fader of the mixer is turned down.
CHANNEL 2 position: This control adjusts the input level of channel 2 of this unit. When the OPERATION switch is set to MONO, this control does not function as it is separated from the signal route.
3 Vents
There are vents of cooling fan in left and right sides. If these vents are covered, such troubles may happen that the cooling function does not work correctly and the OVERHEAT indicator lights up, or that the self restoration thermostat equipped with power trans starts to work and sounds will not able to be heard. Do not cover these vents.
4 OVER HEAT (overheat warning) indicator
(red)
It lights up when the temperature of the inside heat sink goes over the prearranged level. Remove the cause such that the speaker impedance is too low.
7 MONO (monaural) indicator (green)
It appears when the OPERATION switch on the rear panel is set to MONO.
8 POWER switch and pilot lamp (green)
By pressing the upper part, the power is turned on and the pilot lamp lights up. By pressing the lower part, the power is turned off.
Note
When the PROTECTION indicator lights up
In the cases as below, the protection circuit works and the PROTECTION indicator lights up to protect the speakers or the amplifier by cutting down the output power.
• When the connected speaker impedance is too low, or when the output terminals short-circuits.
• When the temperature of the inside heat sink goes over the prearranged level. (The OVERHEAT indicator will continue being lit.)
• When direct current flows into the OUTPUT terminals by a malfunction.
The PROTECTION of this unit is a self restoration type. If it does not restore immediately, set the POWER switch to OFF, remove the cause of trouble, then set the POWER switch to ON again.
4
Page 5
Rear panel
81
915
4 OUTPUT terminals 7 Monitor remote terminal
MONITOR/REMOTE
CH-2
OUTPUT
MONO
CH-2 CH-1
GND HOT COLD GND HOT COLD
OPERATION
STEREO MONO
STACKING
STACKING
INPUT
SPEAKER IMP.
STEREO MONO
4-168-16
GROUND LIFT
CH-1
(MONO)
6 GROUND LEFT switch
ǪÇÃëº
OTHERS
ǪÇÃëº
2 INPUT 2 terminal and STACKING terminal (CH2)
1 INPUT 1 (MONO) terminal and STACKING
terminal (CH1)
Connected to the outputs of a audio mixer. Input signals are output directly to the STACKING terminal. When the OPERATION switch is set to MONO, connect the monaural input signals here.
2 INPUT 2 terminal and STACKING terminal
(CH2)
Connected to the outputs of a mixer. Input signals are output directly to the STACKING terminal. When the OPERATION switch is set to MONO, this terminal is separated from the signal route.
Input connector equivalent to XLR-3-12C
Push here to remove
Put together
Stacking connector equivalent to XLR-3-11C
Put together
Push here to remove
21
3
1: GND 2: HOT 3: COLD
To avoid obstructing by radio frequency waves, connect the earth terminal of XLR cable to number 1 pin.
3 OPERATION switch
The operation mode switches as follows.
Position of OPERATION switch
STEREO MONO
Operation mode
2 channel operation Bridged mono
1 INPUT 1 (MONO) terminal and STACKING terminal (CH1)
5 Barrier strip inputs 3 OPERATION switch
4 OUTPUT terminals
Used to connect to speakers. Connect the + terminal of the speaker to the red terminal, and the – terminal of the speaker to the black terminal. In the case of monaural operation by bridged mono, connect the + terminal of the speaker to OUTPUT 1 red terminal, and the – terminal of the speaker to OUTPUT 2 red terminal.
5 Barrier strip inputs terminals
3P terminal is equipped on the upper side of the XLR connector. In the order from left, 1: GND 2: HOT 3: COLD, the same as the canon connector.
6 GROUND LIFT (earth line switch) switch
In a large scale system, ham noise may be heard due to a difference of GND potential generated between system racks. In this case, ham noise may be decreased by switching the GROUND LIFT switch to separate the signal earth and the body earth. In the case stated above, do not connect the GND Pin of the XLR cable to the number 1 pin.
7 Monitor remote terminal
D-SUB 15 pin connector (female) This terminal enables to monitor signals to be or not, to monitor the protection circuit condition, or to control muting function of this unit from the outside.
Pin arrangement
Before changing the position of this switch, set the POWER switch to OFF.
5
Page 6
Names and functions (continued)
Monitor remote terminal
Specifications of input/output
Pin
1 2 3 4 5 6 7 8
9 to 15
*1
H level output for approximately 8 seconds at power ON of the main unit.
*2
Muting cancel in approximately 8 seconds after H level input.
Signal
SIG 1 OUT SIG 2 OUT GND PROT 1 OUT PROT 2 OUT GND MUTING 1 IN MUTING 2 IN Empty terminal
Signal explanation
Output for CH1 level meter Output for CH2 level meter Signal GNDPIN3 H level output at CH1 protection circuit operation H level output at CH2 protection circuit operation
CH1 muting by L level input CH2 muting by L level input
*2
*2
Block diagram
Signal specifications
0dBu output at 8. 100W output. Output IMP. approximately 2kΩ.
*1
5V TTL level output. Output IMP approximately 10kΩ.
*1
Pull up at input 10k, capable of make Contact.
CH1
INPUT
GROUND LIFT
CH2
INPUT
231
231
ATT
THERMAL
CC
V
SENSOR
SENSOR
132
MONO
ATT
132
OPERATION
MONO
STEREO
SIGNAL
OVER HEAT
SIGNAL
OVERTHERMAL HEAT
CLIP
POWER
AMP
PROTECTION
CIRCUITS
CLIP
POWER
AMP
PROTECTION
CIRCUITS
CH1
OUTPUT
MONO+
PROTECTION
CH2
OUTPUT
MONO–
PROTECTION
6
Page 7
Dimensions
3650
ǪÇÃëº
OTHERS
ǪÇÃëº
482
25
20
ATTENUATOR CH-1
15
dB
10
5
2CHANNEL POWER AMPLIFIER SRP-P450
CLIP
OVER HEAT
PROTECTION
SIGNAL
20
CLIP
OVER HEAT
MONO
25
PROTECTION
ON
SIGNAL
POWER
360
Note
The illustration of the unit is fit in the supplied feet.
CH-2CH-1 15
dB
ATTENUATOR CH-2
406
30054 (52)
140
10
5
132
Putting ATT guard to the unit
How to put in
There is a hole at the upper side, and two holes in the bottom of the ATT guard.
Put the hole at the upper and the hole at the ATT guard together, and push the bottom with a click.
7
Page 8
Main specifications
Input circuit type Electronic balance circuit Input connector XLR-3-31 type
3P terminal panel (1: GND, 2: HOT, 3: COLD)
Stacking terminal XLR-3-32 type Speaker terminal Binding post Rated output (1kHz THD 0.1%) 700W+700W (4Ω)
450W+450W (8Ω) 1400W (8 bridged mono)
Frequency characteristic 20Hz to 20kHz ±0.5dB Damping factor More than 200 (8Ω, 1kHz) Channel separation More than 70dB (at 8Ω, 1kHz 450W output) High frequency distortion Less than 0.008% (at 8Ω, 1kHz 100W output) Remaining noise voltage (IHF-A, input short-circuit) Less than 180µV, Less than 360µV (bridged mono) Maximum amplification 34.5dB, 40.5dB (bridged mono) Indicator SIGNAL indicator (green)
PROTECTION indicator (red) OVER HEAT indicator (red) CLIP indicator (red) MONO indicator (green) POWER indicator (green)
Power requirements AC 230V, 50/60Hz Power consumption 1,200W Power current 7.0A (at 4 1/8 rated output) Dimensions (w/h/d) 482 × 132 × 406mm
(excluding projecting parts and cotrols)
Net weight Approximately 26kg Operation temperature 0˚C to 40˚C Storage temperature –20˚C to 60˚C Accessories Operating instructions (1)
Feet (4) ATT guard (2)
0dBu=0.775V
8
Specifications and appearance are subject to change without notice.
Page 9
Troubleshooting guide
ǪÇÃëº
OTHERS
ǪÇÃëº
By pressing the POWER switch, lamp does not light up and there is no sound.
Although the pilot lamp is lighting, there is no sound. (SIGNAL lamp does not light up either.)
The sound cannot be heard from the speakers. (CLIP indicator, OVER HEAT indicator or PROTECTION indicator lights up.)
When using Bi-AMP, LF signal goes to HF.
In operation of 2CH, low frequencies disappear.
The sound is noisy.
• Is the AC cord connected?
• Is the speakers connected correctly?
• Is the input selection of the mixer correct?
• The fader of the mixer is too low?
• Is there a short circuit in the speaker cord?
• Are the ventilation holes on front or rear covered?
• Do not use a closed rack for ventilation.
• Does CLIP indicator light up frequently?
• MONO STEREO switch on the unit is set to MONO?
• Is the conductors speaker cord connected correctly?
• Is the connected cord pole in correct direction?
• This is set to MONO?
• Are the connections of speaker terminals and connection cords completed?
9
Page 10
10
Printed in Japan