Sony SLV-E720EN Service Manual

SERVICE MANUAL
SUPPLEMENT-1
SLV-E720EN
RMT-V197
North European Model
File this supplement with the service manual.
Subject: EEP ROM INITIAL DATA INPUT
When EEP ROM (IC472 on FR-119 board) was changed, make it sure to input the data shown below and to perform both “2-3-1. RF Switching Position/AF Switching Position Adjustment ”.
Input Method:
1) Connect the LANC jig (J-6090-051-A) to CN164 on MA-286 board.
2) Turn on the power.
3) Input Data: 80 in Address: 00 on Page: 1.
4) Input data on Page F as following table.
Page
Address
Data
F
B594930201
20
0504
B6
6001
10
(99-012)
5) Turn off the power
6) Disconnect the adjusting remote commander and LANC jig from the connector (CN164).
Note: When connecting or disconnecting LANC jig to CN164 on
MA-286 board, first connect the adjusting remote com­mander (J-6082-053-B) to the jack on LANC jig before connecting LANC jig to CN164. Connection or disconnec­tion of the adjusting remote commander in the condition LANC jig is connected to CN164 causes IC LINK (PS001) to damage itself.
9-921-649-81
Sony Corporation
Home Video Company
Printed in Japan © 1999. 9
99I05070-1D
Published by Quality Assurance Dept.
Loading...