Sony SDZ-S130, SDZ-S100 User Manual

S-AIT Tape Drive Unit
4-680-196-13 (2)
Operating Instructions Page 5 _________________________________
Important Safeguards Page 50 ________________________________
SDZ-S100 SDZ-S130
© 2003 Sony Corporation
The model and serial numbers are on a label on the bottom of the unit. Record the serial number in the space provided below. These numbers provide specific information about your S-AIT Tape Drive Unit and will be very helpful if you have to contact technical support.
Model No.
Serial No.
Safety Information
Your S-AIT Tape Drive Unit is assigned model number SDZ-S100 or SDZ-S130 for regulatory compliance certifications. The number is indicated on the model number label on your drive along with the rated voltage and current.
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
Caution
The mains plug on this equipment must be used to disconnect mains power. Please ensure that the socket outlet is installed near the equipment and shall be easily accessible.
Notice
Use the power cord set approved by the appropriate testing organization for the specific countries where this unit is to be used.
Achtung
Zur Trennung vom Netz ist der Netzstecker aus der Steckdose zu ziehen, welche sich in der Nähe des Gerätes befinden muß und leicht zugänglich sein soll.
Hinweis
Die 3-adrige Geräteanschlußleitung muß Typ H05VV-F oder H05VVH2-F sein und nach DIN VDE 0625 geprüft sein. Der Stecker und die Gerätesteckdose müssen nach DIN VDE 0620 bzw DIN VDE 0625 geprüft sein. Der Leitungsquerschnitt kann 0,5mm Anderenfalls muß der Leitungsquerschnitt mindestens 0,75mm
2
betragen wenn die Anschlußleitung eine Länge von 2m nicht überschreitet.
2
betragen.
Hinweis
Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäss EN ISO 7779.
Ratings
Voltage
AC 100 V - 240 V
Current
0.7 A - 0.4 A
Frequency
50 / 60 Hz
Max. Ambient Temperature
35 degrees centigrade
2
A certified power supply cord has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply cord not lighter than ordinary polyvinyl chloride flexible cord according to IEC 60227 (designation H05VV-F 3G 0.75 mm synthetic rubber according to IEC 60245 (designation H05RR-F 3G 0.75 mm
Zum Netzanschluss dieses Gerätes ist eine geprüfte Leitung zu verwenden. Es sind die zutreffenden nationalen Errichtungs- und/oder Gerätebestimmungen zu beachten. Es ist eine geprüfte flexible PVC-ummantelte Leitung entsprechend IEC 60227 (H05VV-F 3G 0.75 mm F 3G 0.75 mm (Bauartkurzzeichen H05RR-F 3G 0.75 mm
2
) zu verwenden. Andernfalls ist eine flexible Leitung aus synthetischem Gummi entsprechend IEC 60245
2
or H05VVH2-F2 3G 0.75 mm2) shall be used. Alternative a flexible cord be of
2
) zu verwenden.
2
) shall be used.
2
oder H05VVH2-
ATTENTION
According to the EU Directives related to product safety, EMC and R&TTE the manufacturer of this product is Sony Corporation, 6-7-35 Kitashinagawa Shinagawa-ku Tokyo, 141-0001 Japan. The Authorised Representative is Sony Deutschland GmbH, Hedelfinger Strasse 61,70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.
AUFMERKSAMKEIT
Im Sinne der EU Richtlinien bezüglich Produktsicherheit, EMV und R&TTE ist Sony Corporation, 6-7-35 Kitashinagawa Shinagawa-ku Tokyo, 141-0001 Japan der Hersteller dieses Produktes. Bevollmächtigter ist Sony Deutschland GmbH, Hedelfinger Strasse 61,D-70327 Stuttgart. Für Service oder Garantieangelegenheiten wenden Sie sich bitte an die in separaten Service oder Garantiedokumenten angegebenen Adressen.
European Union Restriction of Hazardous Substances Directive compliant. Entspricht der Richtlinie der Europäischen Union zur Beschränkung der Verwendung gefährlicher
Stoffe.
Laser Notice (For Model No. SDZ-S130 only)
The equipment contains a tape drive using laser that complies with IEC 60825-1. The equipment is classified as a CLASS 1 LASER PRODUCT.
Caution
The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Caution
Do not look at the end of optical connecor on the back of the tape drive with naked eyes or through optical equipment while the power is supplied to this product. Otherwise, your eyes may be injured.
Bei diesem Laufwerk handelt es sich um ein Laser-Produkt der Klasse 1.
INFORMATION
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
3
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experience radio/TV technician for help.
The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
If you have any questions about this product, contact your dealer.
Declaration of Conformity Trade Name: SONY Model No.: SDZ-S100, SDZ-S130 Responsible Party: Sony Electronics Inc. Address: 16530 Via Esprillo San Diego, CA. 92127 U.S.A. Telephone No.: 858-942-2230 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Für Kunden in Deutschland
Diese Ausrüstung erfüllt die Europäischen EMC-Bestimmungen für die Verwendung in folgender/folgenden Umgebung(en):
• Wohngegenden
• Gewerbegebiete
• Leichtindustriegebiete (Diese Ausrüstung erfüllt die Bestimmungen der Norm EN55022, Klasse B.)
For Users in Japan
For Users in Korea
4

Table of Contents

Chapter 1 Introduction
Chapter 2 Installation
Overview.......................................................................7
S-AIT Technology........................................................7
Product Features.........................................................8
Compatible Cartridges................................................9
Data Cartridges ...............................................................9
Cleaning Cartridges......................................................... 9
Supported Software ....................................................9
Components and Functions.....................................10
Front.............................................................................. 10
Rear ...............................................................................13
Bottom........................................................................... 15
About the label...........................................................16
Overview.....................................................................17
Unpacking ..................................................................17
Package Contents .....................................................18
Preparing the Host Computer ..................................18
Setting the DIP Switches ..........................................19
If necessary, change the settings as follows..................19
Setting the SCSI ID (SDZ-S100 only) .......................22
Setting the Loop ID (SDZ-S130 only).......................23
Installing the S-AIT Tape Drive Unit.........................25
Connecting the Power Cable....................................26
Installing Device Drivers...........................................26
Connecting the SCSI Bus Cable
(SDZ-S100 only) ..................................................27
Connecting the Optical Fiber Cable for
Fibre Channel (SDZ-S130 only) ........................29
Configuring the S-AIT Tape Drive Unit to
the Host ...............................................................30
Chapter 3 Operation
Overview.....................................................................31
Turning the Unit On or Off........................................31
Turning On the Unit...................................................... 31
Turning Off the Unit .....................................................33
Preparing Cartridges.................................................33
Inserting a Cartridge .................................................33
Removing a Cartridge ...............................................34
5
Chapter 4 Using the Media
Appendix
Compatible Cartridges..............................................35
Data Cartridge............................................................35
Components and Functions........................................... 36
Setting the Write-protect Switch..............................38
Cleaning Cartridge ....................................................38
Handling Cartridges ..................................................39
Usage, Storage, and Transport Environmental
Specifications .....................................................40
Head Cleaning............................................................41
Changing the Air Filter Unit......................................42
Hardware Reset .........................................................43
Updating the Firmware..............................................43
Taking Care of the Unit .............................................43
Safety ............................................................................43
Avoiding Damage .........................................................44
Troubleshooting ........................................................45
Specifications ............................................................47
Performance ..................................................................47
Environmental Specifications .......................................47
Power Specifications/Miscellaneous.............................48
Options.......................................................................48
Index ...........................................................................49
© 2003 Sony Corporation. All rights reserved.
Trademarks
• Sony, Advanced Intelligent Tape, and Super Advanced Intelligent Tape are trademarks or registered trademarks of Sony Corporation in this country, other countries, or both.
• Other product names are trademarks or registered trademarks of their respective owners in this country, other countries, or both.
6

Overview

S-AIT Technology

Introduction
The S-AIT Tape Drive Unit is a tape streamer that makes use of “S-AIT” (Super Advanced Intelligent Tape) technology. The S-AIT drive stores large amounts of image data on a single half-inch tape cartridge, making it the industry's highest capacity tape drive.
Helical Scan Recording Technology
Helical scan technology, based on a very stable rotating drum/head platform, permits accurate and reliable data recording at very high track densities. This efficient packing density provides the industry’s leading, space-efficient solution.
Chapter
1
Advanced Metal Evaporated (AME) Tape
S-AIT media is based on AME technology. This technology represents the culmination of over 50 years of Sony innovation and experience in magnetic tape technology. The AME tape formulation, with diamond-like carbon coating, offers an extraordinary durability and reliability, up to 30,000 media passes, and an estimated media archival life of up to 30 years.
Remote Memory in Cassette (R-MIC)
The non-volatile R-MIC chip built into the data cartridge provides quick media loads and allows fast searches of data. The R-MIC chip contains the tape’s system log, search map and user-definable information, allowing the drive to advance at high speed directly to any file on the tape.
Reliability
The reliability of the S-AIT drive is in part the due to its innovative features, such as its automatic head cleaning system and effective “leader block” tape threading system with simplified tape load path. The drive cooling system is also isolated from the sealed tape mechanism, thereby preventing airborne contaminants from entering the tape path and affecting sensitive components.

Chapter 1 Introduction

7

Product Features

Two models of S-AIT Tape Drive Units are available according to the type of interface of your host computer.
SDZ-S100
Uses the Ultra 160 Wide Low Voltage Differential/Single-Ended (LVD/SE) SCSI
SDZ-S130
Uses 2 Gbps Fibre Channel interface
Common Features
• Native storage capacity of 500 GB per cartridge (1.3 TB at 2.6:1 compression) with the S-AIT data cartridge SAIT1-500.
• Native sustained data transfer rate of 30 MB per second.
• High data reliability with the Read After Write and Fragment Rewrite functions, and the three levels of Error Correction Code (ECC).
• Possibility to enable and disable the Read After Write (RAW) function.
• High-speed search and tape rewind.
• Supports variable and fixed record length.
• 72 MB buffer memory.
• Very compact design that allows you to set two units side by side on a 19-inch rack (2U height).
• Sealed mechanism with the front door and the air filter.
• Very easy to change the air filter.
• Half transparent front panel through which you can verify the cartridge even when the door is closed.
• Sleek and elegant design.
Features of the SDZ-S100 (SCSI model)
• Ultra 160 SCSI LVD/SE interface is fully supported for host computer access.
• Burst data transfer rate of 160 MB per second, synchronous.
• Supports SCSI disconnection and arbitration.
Features of the SDZ-S130 (Fibre Channel Interface model)
• 2 Gbps Fibre Channel interface.
• 200 MB per second burst data transfer rate.
• Private Loop, Public Loop, Point-to-Point, and Switched Fabric topologies.
• Full-duplex transfers.
• FCP2 support.
• Class of service: Class 3
8
Chapter 1 Introduction

Compatible Cartridges

Data Cartridges

Tape cartridges used with the S-AIT Tape Drive Unit must be marked with the SAIT-1 logo.
SAIT-1 logo
Caution
Only use cartridges designed specifically for S-AIT.

Cleaning Cartridges

To clean the read/write heads, use the S-AIT Cleaning Cartridge. For details about cleaning, see “Head Cleaning” on page 41.

Supported Software

For details about software that can be used with the S-AIT Tape Drive Unit and supported operating systems, contact your dealer.
Chapter 1 Introduction
9

Components and Functions

Front

A Front Door
Used to protect the front of the unit. Press the DOOR button to unlock and open the door when inserting or removing cartridges.
Note
Even when the front door is closed and a cartridge is ejected by software, the cartridge does not come in contact with the door. You can therefore keep the door closed except when inserting or removing cartridges to minimize any contamination from airborne particles.
MOTION
OPEN
TAPE
DRIVE
TAPE
ERROR
CLEANING REQUEST
ERROR
B DOOR Button
Press to open the front door.
10
Chapter 1 Introduction
Front door opened
1 2 3
456789
A Power Switch
Press this switch to turn the S-AIT Tape Drive Unit on or off. When you restart the unit, be sure to wait at least 10 seconds before turning it on again.
B POWER Indicator
Lights green when the unit is on. When it flashes, the cooling fan of the unit may be malfunctioning. If this is the case, verify that the cooling fan on the rear is operating normally. If it is not, contact your dealer.
C Cartridge Slot
Used to insert and remove cartridges.
D Eject Button
Push to manually eject cartridges from the unit. The unit ejects cleaning cartridges automatically.
E CLEANING REQUEST Indicator
Flashes yellow when the read/write heads need cleaning. For details about cleaning, see “Head Cleaning” on page 41.
F TAPE ERROR Indicator
Flashes or lights orange when media errors occur. When media warnings occur, the indicator flashes yellow. In this case, copy data to another cartridge.
G DRIVE ERROR Indicator
Flashes orange or yellow when drive errors occur.
H TAPE MOTION Indicator
Lights when you insert cartridges. The color of the indicator, shows whether the cartridge is write-protected. Moreover, when the unit is operating, the indicator flashes. The color of the flashing indicator shows the status of the unit.
I Hardware Reset Hole
Used to reset the unit in case of emergency. Using the emergency reset hole when reading or writing data may damage your data, therefore this procedure should only be used for maintenance purposes.
Chapter 1 Introduction
11
Drive Status
The indicators of the S-AIT Tape Drive Unit show the status of the unit. This status is indicated by a combination of colors (green, orange, or yellow), and whether the indicators are lit or flashing. Refer to the table below for explanations about the meaning of indicator activity.
CLEANING
REQUEST
No cleaning
request
All green, flashing
All green, lit Orange,
flashing Orange, lit
Yellow, flashing
Yellow, lit
Green, flashing
Green, lit
Off
TAPE MOTION DRIVE ERROR TAPE ERROR
Firmware update
Ejection inhibited (only when pressing the eject button)
Tape being
accessed (write)
⎯⎯Media error
Tape being
accessed
(search)
Tape loaded
(write-protected)
Tape being
accessed (read)
Tape loaded
(write-enabled)
No tape No drive error No media error
Drive error Media error Cleaning error
Drive error Media warning Cleaning request
⎯⎯Cleaning
⎯⎯⎯
⎯⎯⎯
Note
When you turn on the unit or reset it, all the indicators light green for about half a second. They then flash repeatedly yellow from left to right for about 3 seconds, indicating that the unit is performing a self-diagnostic.
12
Chapter 1 Introduction

Rear

SDZ-S100
A SCSI ID Switch
Used to set the SCSI ID of the S-AIT Tape Drive Unit. Upon shipment, the SCSI ID is 0. For details, see “Setting the SCSI ID (SDZ-S100 only)” on page 22.
B RS-232C Connector
For service use only. You do not normally need to use this connector.
C Cooling Fan and Ventilation Holes
Be careful not to block the ventilation holes. If you do, the unit may overheat, resulting in damage.
D AC IN Connector
Connect the power cable appropriate for your country to this connector.
E Ventilation Holes
Be careful not to block the ventilation holes. If you do, the drive in the unit may overheat, resulting in damage.
F SCSI Connector 1, 7 SCSI Connector 2
Connect the SCSI bus cable to this connector. For details about connection, see “Connecting the SCSI Bus Cable (SDZ-S100 only)” on page 27.
Chapter 1 Introduction
13
SDZ-S130
1 2
346 57
A RS-232C Connector
For service use only. You do not normally need to use this connector.
B Cooling Fan and Ventilation Holes
Be careful not to block the ventilation holes. If you do, the unit may overheat, resulting in damage.
C AC IN Connector
Connect the power cable appropriate for your country to this connector.
D Ventilation Holes
Be careful not to block the ventilation holes. If you do, the drive in the unit may overheat, resulting in damage.
E FC Status Indicator
When the fibre channel connection is normal, the indicator is off. When the unit is communicating with the host computer, this indicator lights green. When there is a connection error, the indicator lights orange. In this case, reconnect the cable or change it if necessary.
F Loop ID Jumpers
These jumpers are functional when the topology is arbitrated loop. For details, see “Setting the Loop ID (SDZ-S130 only)” on page 23.
G Fibre Channel Connector
Connect the optical fiber cable for Fibre Channel. For details about connection, see “Connecting the Optical Fiber Cable for Fibre Channel (SDZ-S130 only)” on page 29.
14
Chapter 1 Introduction

Bottom

1
2
3
A Access Cover for Service Use
Do not open this cover. For service use only.
B Dip Switch Access Cover
If you need to change the data compression settings, remove this cover to change the DIP switch settings. For details about setting the DIP switches, see “Setting the DIP Switches” on page 19.
C Air Filter Unit
Be careful not to block the ventilation holes of the air filter unit. If you do, the S-AIT Tape Drive Unit may overheat, resulting in damage. Moreover, periodically clean the air filter unit with a vacuum cleaner (monthly cleanings recommended) and replace it yearly. For details about how to replace the air filter unit, see “Changing the Air Filter Unit” on page 42.
Chapter 1 Introduction
15

About the label

2 3
1
A Model number
The model number is located on the bottom of the unit, together with the serial number. Refer to the model and serial numbers on the label when seeking technical support.
B Serial number
The serial number is located on the bottom of the unit, together with the model number. Refer to the serial and model numbers on the label when seeking technical support.
C Number returned to the interface command
The number, which is returned to the interface command, is located on the rear of the unit. This is the serial number reported by the application software you use.
16
Chapter 1 Introduction

Overview

Unpacking

Installation
This chapter describes the general procedures for positioning the S-AIT Tape Drive Unit, connecting it to the host computer, and turning it on. This chapter also describes initial setup. Installation and setup procedures may vary slightly depending on your system.
Note
You will need the box and packing materials if you wish to move or transport the unit. Retain them for future use.
Chapter
2
1
Remove the unit from the box as indicated below.
Remove the packing materials, such as plastic covers and tapes.
2
Inspect the unit for shipping damage.
If there is damage, do not use the unit. Report the damage immediately by contacting your dealer.

Chapter 2 Installation

17

Package Contents

After opening the package, make sure that all the following items are present. Contact your dealer if anything is missing.
• S-AIT Tape Drive Unit (1)
• Operating Instructions (1)
Note
In addition to the above, other items may be included in the package.

Preparing the Host Computer

Prepare the host computer before installing the S-AIT Tape Drive Unit.
1
Make sure that a SCSI host adapter card or Fibre Channel host bus adapter (FC HBA) is installed in the host computer.
2
Install all the necessary software supporting the unit on the host computer.
For details about the software that can be used with the S-AIT Tape Drive Unit and supported operating systems, contact your dealer.
18
Chapter 2 Installation

Setting the DIP Switches

By setting the DIP switches at the bottom of the S-AIT Tape Drive Unit, you can:
• Choose whether to compress the data when recording.
• Choose whether the host can control data compression.
The default settings of the DIP switches is as follows.
• DC Control-1: ON Compression is enabled.
• DC Control-2: OFF The host can control compression.

If necessary, change the settings as follows

Caution
Before removing the access cover to change DIP switch settings of the S-AIT Tape Drive Unit, turn off the unit and disconnect the power cable.
1
Make sure that the unit is off.
2
Remove the two screws with a screwdriver and remove the access cover.
Screw
Access cover
DIP switches
Chapter 2 Installation
19
3
Change the settings with a pointed object.
Each DIP switch is defined in the tables below.
SWA settings (SDZ-S100)
SWA (SDZ-S100)
ON
OFF
12345678
SWA (SDZ-S130)
ON
OFF
12345678
SW1 Custom-1 OFF
SW2 Block Size ON
SW3 Immediate WFM OFF
SW4 Custom-4 OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 DC Control-1 ON
SW8 DC Control-2 OFF
SWA settings (SDZ-S130)
SW1 UA Control ON
SW2 Block Size ON
SW3 Immediate WFM OFF
SW4 Custom-4 OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 DC Control-1 ON
SW8 DC Control-2 OFF
SWB
ON
OFF
12345678
DC
Control-1
OFF OFF
OFF ON
ON OFF
ON ON
DC
Control-2
SWB settings (Common)
SW1 Reserved OFF
SW2 Reserved OFF
SW3 Reserved OFF
SW4 Reserved OFF
SW5 Reserved OFF
SW6 Reserved OFF
SW7 Reserved OFF
SW8 Reserved OFF
Definition
Compression disabled. The host can control compression.
Compression disabled. The host cannot control compression.
Compression enabled. The host can control compression.
Compression enabled. The host cannot control compression.
20
Chapter 2 Installation
Loading...
+ 44 hidden pages