Sony SAWEX-200 Service manual

SA-WEX200
SERVICE MANUAL
Ver 1.0 2001.09
SA-WEX200 is sub woofer in CMT-EX200.

SPECIFICATION

Amplifier section
For the U.S.model AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC DISTORTION: With 4 ohms loads,from 50 – 150 Hz;rated 30 watts per channel minimum RMS power,with no more than 10%total harmonic distortion from 250 milli watts to rated output.
Canadian model:
Continuous RMS power output (reference):
30 watts (4 ohms at 55 Hz,10% THD)
Speaker system Active sub woofer
(magnetically shielded design)
US Model
Canadian Model
Speaker unit 10 cm dia,cone type
woofer (x2) Practical maximum output 30 watts Reproduction frequency range
45 – 150 Hz High frequency cut-off range
70 – 150 Hz Phase selector Normal,reverse Input SPEAKER INPUT:
Input terminal Output SPEAKER OUTPUT:
Output terminal Power requirements 120 V AC,60 Hz Power consumption 40 watts Dimensions Approx.150 x 220 x
345 mm (w/h/d,incl.
projecting parts and
controls) Mass Approx.6.2 kg
Design and specifications are subject to change without notice.
2001I0200-1
© 2001.9
ACTIVE SUBWOOFER
Sony Corporation
Home Audio Company Shinagawa Tec Service Manual Production Group
1
SA-WEX200
SAFETY CHECK-OUT
(US model)
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: Check the antenna terminals, metal trim, metallized knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The limit indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2V AC range are suitable. (See Fig. A)
TABLE OF CONTENTS
1. GENERAL .......................................................................... 3
2. DIAGRAMS
2-1. Circuit Boards Location ........................................................ 3
2-2. Printed Wiring Board ............................................................ 4
2-3. Schematic Diagram ............................................................... 5
3. EXPLODED VIEW
3-1. Front Section ......................................................................... 6
4. ELECTRICAL PARTS LIST ......................................... 6
To Exposed Metal Parts on Set
0.15µF
1.5k
Earth Ground
AC voltmeter (0.75V)
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
2
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ! LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
• Location of controls
d
SECTION 1

GENERAL

This section is extracted from instruction manual.
SA-WEX200
SECTION 2

DIAGRAMS

THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS. (In addition to this, the necessary note is printed in each block.)
Sub Woofer
For printed wiring boards.
Note:
X : parts extracted from the component side.
b : Pattern from the side which enables seeing.
For schematic diagrams.
Note:
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics and tantalums.
• All resistors are in and 1/
specified.
C : panel designation.
Note:
The components identi­fied by mark 0 or dotted line with mark 0 are criti­cal for safety. Replace only with part number specified.
: B+ Line.
: B– Line.
• Voltages are dc with respect to ground under no-signal con­ditions. no mark : Power on
• Voltages are taken with a VOM (Input impedance 10MΩ). Voltage variations may be noted due to normal preduction tolerances.
• Signal path. K : AUDIO
4
W or less unless otherwise
Note:
Les composants identifiés par une marque 0 sont critiques pour la sécurité. Ne les remplacer que par une piéce portant le numéro spécifié.
CUT OFF FREQ 3 (15) LEVEL 1 (15) PHASE 4 (15) Power indicator 2

2-1. Circuit Boards Location

POWER AMP board
FRONT board
AC board
MAIN boar
33
INPUT board