Page 1
4-590-269-16(1)
Production Control Software
Installation Guide
PWA-PRC1
© 2016 Sony Corporation
Page 2
NOTICE TO USERS
© 2013, 2014, 2015, 2016, 2017, 2018, 2019 Sony Corporation
All rights reserved. This manual or the software described herein, in whole or in part, may not
be reproduced, translated or reduced to any machine readable form without prior written
approval from Sony Corporation.
SONY CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL, THE
SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY
DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE SOFTWARE OR SUCH OTHER
INFORMATION.
IN NO EVENT SHALL SONY CORPORATION BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING
OUT OF OR IN CONNECTION WITH THIS MANUAL, THE SOFTWARE OR OTHER INFORMATION
CONTAINED HEREIN OR THE USE THEREOF.
Sony Corporation reserves the right to make any modification to this manual or the
information contained herein at any time without notice.
The software described herein may also be governed by the terms of a separate user license
agreement.
Page 3
Table of Contents
Overview ................................................................................................................ 5
Operating Environment ............................................................................................. 6
Required Equipment ............................................................................................ 6
Preparation ............................................................................................................. 7
Attaching MSQ-S321 (pre-installed in the PWS-100PR1/PWS-110PR1) .......................... 8
Updating the MSQ-S321 Driver and Firmware ......................................................... 8
Installing the PWSK-4403 Driver (pre-installed in the PWS-100PR1/PWS-110PR1) .......... 8
Settings When Using Two PWSK-4403 Panels ............................................................. 9
Configuring PRC Manager ..................................................................................... 10
Configuring Share Play Usage ................................................................................ 11
Configuring the PWS-4500 .................................................................................... 12
Configuring the BPU4800 ...................................................................................... 17
Configuring the PC ............................................................................................... 19
Taskbar Settings ............................................................................................... 19
Multi-Language Input Settings ............................................................................ 19
Settings for Archiving/Retrieving Playlist and Cut Out Data ..................................... 20
Settings for using Submonitors ........................................................................... 23
Connections .......................................................................................................... 24
2IN/2OUT (4K) with 10GbE Network .................................................................... 24
3IN/1OUT (4K) with 10GbE Network .................................................................... 25
1IN/1OUT (4K) with 10GbE Network, without PWSK-4504 ...................................... 26
2IN/2OUT (HD) with 1GbE Network, without PWSK-4504 ........................................ 27
2IN/1OUT (HD) with 1GbE Network, without PWSK-4504 ........................................ 28
6IN/2OUT (HD) with 1GbE Network, without PWSK-4504 ........................................ 29
4IN/2OUT (HD) with 1GbE Network ..................................................................... 30
6IN/1OUT (HD) with 1GbE Network ..................................................................... 31
HFR 2IN/1OUT (4K 2x) with 10GbE Network ......................................................... 32
HFR 1IN/2OUT (4K 2x) with 10GbE Network ......................................................... 33
HFR 5IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network ................................................ 34
HFR 4IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network ................................................ 35
HFR 3IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network ................................................ 36
HFR 3IN/2OUT (HD 8x, 6x) with 1GbE Network ..................................................... 37
HFR 3IN/1OUT (HD 8x, 6x) with 1GbE Network ..................................................... 38
HFR 2IN/2OUT (HD 8x, 6x) with 1GbE Network ..................................................... 39
Cut Out with 10GbE Network (for MSQ-S321 1pc) ................................................. 40
Cut Out with 10GbE Network (for MSQ-S321 2pcs) ................................................ 41
HFR + Cut Out with 10GbE Network (for MSQ-S321 1pc) ........................................ 42
Cut Out with 10GbE Network, without PWSK-4504 ................................................. 43
3
Page 4
BPU4800 Replay Port, Replay Port + XAVC Transcode Port ...................................... 44
BPU4800 XAVC Transcode Port, Replay Port + XAVC Transcode Port ......................... 45
BPU4800 HD Cut Out Port .................................................................................. 46
Connection for using Share Play Function ............................................................. 47
Submonitor Connections .................................................................................... 48
Network Cable .................................................................................................. 49
SDI Input/Output.............................................................................................. 49
Installation ............................................................................................................ 52
Installing ............................................................................................................ 52
To uninstall ...................................................................................................... 52
Starting and Exiting Program ................................................................................... 53
Staring PRC Manager ......................................................................................... 53
Starting PWA-PRC1 ........................................................................................... 54
Exiting PWA-PRC1 ............................................................................................. 54
About Authentication .............................................................................................. 55
Executing Authentication .................................................................................... 55
Setting ................................................................................................................. 56
Displaying the Settings Screen ............................................................................ 56
Configuration Items .......................................................................................... 56
Appendix .............................................................................................................. 59
Usage Precautions ............................................................................................... 59
Trademarks ........................................................................................................ 59
4
Page 5
Overview
PWA-PRC1 Production Control Software is application software to control the PWS-4500
Multiport AV Storage Unit and BPU4800 Broadband Processor Unit, play-out live video at slow
speeds, and manage clips/playlists.
This document explains installation of PWA-PRC1, and the necessary settings and connections
to use PWA-PRC1.
The intended audience for this documentation is engineers who perform system integration
and installation.
5
Page 6
Operating Environment
Required Equipment
To u se PWA-PRC1, the following equipment is required.
• PWS -100PR1, PWS-110PR1, or PWS-100MG1
• PWS -4500 Multiport AV Storage Unit, or
BPU4800 Broadband Processor Unit
• PWSK -4403 USB control device (up to two devices can be connected)
• MSQ -S321 XAVC 4K/HD codec card (pre-installed in the PWS-100PR1/PWS-110PR1)
Note
MSQ-S321 uses the Source Code of T-Kernel 2.0 under T-License 2.0 granted by T-Engine Forum
(www.t-engine.org).
The following are optional equipment for file transfer and/or archive.
• PWA -MGW1 Media Gateway software
• PWS -100MG1 Media Gateway Station (with PWA-MGW1 installed)
Obtain the following adapters if a DisplayPort-to-HDMI adapter or DisplayPort-to-DVI adapter is required
when connecting the main display.
• DisplayPort → HDMI adapter: StarTech.com DisplayPort to HDMI Active Adapter
• DisplayPort → DVI adapter: XFX MA-AP01-PD1K Active DisplayPort to DVI Adapter
For touch panel operation, prepare the following display.
• Dell S2240T
Submonitors can be used to display the settings and control status of each operation panel.
Recommended submonitor devices:
• ADTECHNO CL5585H
• Sony CLM -V55 Clip-on LCD Monitor
Use with the following AC adaptor.
AC-PW10AM
Notes
• Use the same model submonitor if using two submonitors.
• Obtain the USB external graphic adapter if using second submonitor.
Tested USB external graphic adapter:
・ I-O DATA USB-RGB3/H
・ StarTech.com USB32HDES Slim USB3.0 to HDMI External Video Card Multi Monitor Adapter
6
Page 7
Preparation
Note
User's Guide, Installation Guide, Release Note are installed below in
PWS-100PR1/PWS-110PR1.
C:\ ProgramData\ Sony\ Documents\ PWA-PRC1
PWA-PRC1 Software Package
Package Name: Sony_PWA-PRC1_(version)_package.zip
Copy the above file, which is downloaded from the eCSite to an arbitrary directory and extract
the file there.
The following files are contained in Sony_PWA-PRC1_(version)_ package.zip.
• PWA -PRC1 Installer : Sony_PWA-PRC1_(version).exe
• PWSK-4403 Driver : pwsk-4403_drv.zip
• MSQ -S321 Installer : Sony MSQ-S321_2BS PWS-100 PWS-300_(version).msi
• User’s Guide (Japanese) : PWA-PRC1_UG_(version)_JP.pdf
(English) : PWA-PRC1_UG_(version)_GB.pdf
(Chinese) : PWA-PRC1_UG_(version)_CS.pdf
• Installation Guide (Japanese) : PWA-PRC1_IG_(version)_JP.pdf
(English) : PWA-PRC1_IG_(version)_GB.pdf
• Release Note (Japanese) : ReleaseNotes_PWA-PRC1_(version)_ja.pdf
(English) : ReleaseNotes_PWA-PRC1_(version)_en.pdf
Notes
• PWA -PRC1 does not support the sleep mode of PC. Do not let PC go to sleep while operating PWA-PRC1.
• Use the same Video Format and Timecode drop-frame mode settings for devices in a system.
7
Page 8
Attaching MSQ-S321 (pre -installed in the PWS-100PR1/PWS-110PR1)
Attach MSQ-S321 if installing PWA-PRC1 in PWS-100MG1 device.
1. Install the MSQ-S321 board in the top slot of the PWS-100MG1.
Refer to the PC and MSQ-S321 service manual for details on installation and associated
notes.
2. Install the MSQ-S321 device driver.
Refer to MSQ-S321’s service manual for details on installation.
Note
Two MSQ-S321 boards are installed in the PWS-100PR1/PWS-110PR1.
Board No. Mounting slot Board ID (DIP switch S4002 settings)
Board 1 Lower 0 (Bits 1 to 4 are Off)
Board 2 Upper 1 (Bit 1 only is On)
Updating the MSQ-S321 Driver and Firmware
Use the following procedure if you need to update the driver and firmware of the MSQ-S321.
1. Double-click the Sony MSQ-S321 PWS-100 PWS-300_(version).msi installer, and follow
the on-screen instructions for installation.
2. Shut down the PC (use “Shutdown,” not “Restart”).
3. Start the PC.
Installing the PWSK-4403 Driver (pre -installed in the
PWS-100PR1/PWS-110PR1)
1. Connect between PWSK-4403 and PC with a USB cable.
2. Turn on PWSK-4403.
3. Decompress PWSK-4403 Driver file (pwsk-4403_drv.zip).
4. Open [Device Manager], and then click [Other devices].
5. Right-click [Unknown device], and then click [Update Driver Software…].
6. On the [Update Driver Software] window, click [Browse my computer for driver software].
7. On the [Browse For Folder] window, select the “\ pwsk-4403_drv\ package" folder and click
[OK].
8. Click [Next].
9. On the [Windows Security] window, click [Install].
Driver installation starts.
10. On the [Device Manager] window, click [Universal Serial Bus Controller], and check to see
“Sony Control Device Panel (version)” is recognized correctly.
8
Page 9
Settings When Using Two PWSK-4403 Panels
Configure the following settings when using two PWSK-4403 panels.
1. Remove the cap from the rear of the PWSK-4403.
2. Set the DIP switches as follows.
PWSK-4403 DIP switches
Bit 3 Bit 4
Panel 1 OFF OFF
Panel 2 OFF ON
DIP switches
PWSK-4403 rear view
Panel 1 Panel 2
Note
If the PWSK-4403 connection is changed after starting PWA-PRC1, click [Update] under [GUI and Panel
links] on the Settings screen of PWA-PRC1.
For details about the Settings screen of PWA-PRC1, refer to the User’s Guide.
9
Page 10
Configuring PRC Manager
PRC Manager software is included with PWA-PRC1. PRC Manager is software that manages the
PWS-4500/BPU4800 devices, PWA-PRC1, and PWA-MGW1 on a network without using an
operation screen.
Only one PRC Manager instance must be running on a network, regardless of whether there is
only one PWA-PRC1 or multiple PWA-PRC1 installations on the same network.
Note
If both PWA-PRC1 and PWA-MGW1 are on the same network, do not use PRC Manager on the
PWA-MGW1.
To perform management functions using PRC Manager, the PWS-4500/BPU4800 and
PWA-MGW1 must have the following settings.
PWS-4500/BPU4800 settings
Click [System] – [Network], and configure the following settings in [PRCM Setting] on the
displayed screen.
Item Setting
Port Number 50000
PRCM 1 Connection Enable
PRCM 1 IP Address IP address of PC on which PRC Manager is installed
PWA-MGW1 settings
Click [Settings] – [PRC Manager] – [PRC Manager List] – [Add], and configure the following
settings on the displayed screen.
Item Setting
IP Address IP address of PC on which PRC Manager is installed
Port Number 51000
PWA-PRC1 settings
If using an NMI and Share Play, different settings for PTP domain are required. If the settings
need to be changed, change the PTP domain setting in [Settings] – [System 1] – [PRC
manager].
10
Page 11
Configuring Share Play Usage
The following configuration is required in order to use the PWA-PRC1 Share Play function.
PWS-4500/BPU4800 settings
Click [System] – [Share Play], and configure the following settings in [Share Play Network
Setting] – [Primary] on the displayed screen.
Item Setting
IP Address IP address for Share Play
Subnet Mask 255.255.255.0
Click [System] – [Share Play], select the format to use in [Estimate Share Play Maximum Tx
Number] and configure the following settings on the displayed screen.
Item Setting
Share Play Tx:Rx
Setting
Set to the following according to the set value of
[Maximum Tx Number].
2:2 (if [Maximum Tx Number] is 2 or higher)
1:3 (if [Maximum Tx Number] is 1)
0:4 (if [Maximum Tx Number] is 0)
To play network clips in a playlist directly, the following
settings are required.
For 1PGM
Local server: 2:2
Network server: 2:2
For 2PGM
Local server: 1:3
Network server: 3:1
11
Page 12
Configuring the PWS-4500
This section describes the web menu of PWS-4500 V2.6 as an example.
1. Configure the PWS-4500 Port A through Port D settings, according to the PGM mode used
by PWA-PRC1.
When each condition is selected in the following figure (
from the enabled I/O configurations.
Refer to the PWS-4500 Operation Manual for details on port settings.
Note
PWA-PRC1 does not support 1-IN, 2-IN, 3-IN, 4-IN, 2-OUT, 3-OUT, 4-OUT, 1-IN 3-OUT, 2-IN 3-OUT,
and 8-IN configurations as the local server.
), select the desired settings
12
Page 13
2. Configure each port.
Note
PWA-PRC1 may not function properly if the following settings are not correctly made. Be sure to make the
following settings.
• Make the same Video Format settings for each port.
• In Cut Out mode, make the same Format settings for PortD: Output and [Monitor Out].
• In Cut Out mode, make the same settings for [Monitor Out] for each port.
• In modes other than Cut Out mode, set [Monitor Out] to “xxp to xxI & HD-SDI” (where “xx” is the
resolution) where available.
• Set [Chunk File] of the input port to “24H”.
• TC to Input shall be in synchronization. Set [TCG Source] of the input port to “Master TC”.
13
Page 14
• Configure the correct [DF mode] for each input/output port. Do not mix DF and NDF settings.
Note
Correct operation will not occur if a TC jump exists in the recorded file.
14
Page 15
• Set [Forced Shuttle Mode] of the output port to “Off” .
• Set [Shuttle Muting] of the output port to “O n”.
15
Page 16
• When using Cut Out mode, set [Time Shifted Play] to “From Storage Only”.
• When recording using Loop Recording, set all recording ports on the PWS -4500 to the same settings.
Note
If the port settings are changed, reconfigure [Create Loop Recording Area].
16
Page 17
Configuring the BPU4800
Configure the input/output ports of the BPU4800. This section describes the web menu of
BPU4800 V1.5 as an example.
The following four methods are supported for using ports.
Port Description
Replay Port Set when using as the PWA-PRC1 local server for replay control.
It can also be used as a network server for Share Play connection.
Clips created on the BPU4800 cannot be transferred to an external device.
XAVC Transcode Port Set when using as a network server for Share Play connection.
Clips created on the BPU4800 can be transferred to an external device.
Cannot be used as the local server.
HD Cut Out Port Set when using as the PWA-PRC1 local server for Cut Out operation.
It can also be used as a network server for Share Play connection.
Clips created on the BPU4800 cannot be transferred to an external device.
Replay Port + XAVC
Transcode Port
This setting is selected automatically if the format is HD.
It enables replay control and transcoding to XAVC files.
The playback port method selection is configured using the [Replay Port + XAVC Transcode
Port] setting in the web menu of the BPU4800.
17
Page 18
Notes
• When HD Cut Out Port is selected, make sure the Format of the slot used for connection with the
PWS-100PR1/PWS-110PR1 is the same as the Format of Slot 1 Replay (Slot 1 is set using the web
menu, and the slot used for PWS-100PR1/PWS-110PR1 connection is set using the BPU menu).
• Set each port to the correct [DF Mode] setting. Do not mix DF and NDF settings .
• Set the [Forced Shuttle Mode] setting of the Replay port to [Off].
• When HD Cut Out Port is selected, set [Time Shifted Play] to [From Storage Only].
18
Page 19
Configuring the PC
Taskbar Settings
1. Right-click the taskbar and select [Properties].
2. In the [Taskbar Properties] dialog, turn [Auto-hide the taskbar] on.
3. If using a submonitor, turn [Show taskbar on all displays] off under [Multiple displays].
Multi-Language Input Settings
PWA-PRC1 supports English, Japanese, and Chinese character input. To enter clip names,
playlist names, and server names in a language other than English, configure the following
settings.
1. Select [Control Panel] – [Language].
2. Click [Add Language].
3. Select the language to add.
For example, to enter text in Japanese, select “Japanese”.
4. Click the [Add] button.
5. Repeat steps 3 and 4 to add any additional languages.
To switch the input language
Press the Windows + space key combination. The languages added above appear in a menu.
Select a language to change the input language.
19
Page 20
Settings for Archiving/Retrieving Playlist and Cut Out Data
Shared folder settings are required when archiving playlist and cut out data created using
PWA-PRC1, and when retrieving from the PWA-MGW1 service.
1. PWA-MGW1 shared folder settings
(1) Right-click the C:\ MG_PLCD folder on the PC on which PWA-MGW1 is installed, and select
[Share with] → [Specific people…].
Note
The “MG_PLCD” folder is created when PWA-MGW1 starts.
(2) In the [File Sharing] dialog, select the account to permit sharing, and click the [Add]
button.
20
Page 21
(3) Set [Permission Level] to “Read/Write.”
(4) Click the [Share] button.
(5) Check the setting in the confirmation dialog, and click the [Done] button.
The “MG_PLCD” folder becomes shared.
2. Access credentials on the PC running PRC Manager
(1) Open Explorer, enter “\\ IP address of PC with PWA-MGW1 installed\ mg_plcd,” and press the
[Enter] key.
The [Windows Security] dialog appears.
If the contents of the “MG_PLCD” folder are displayed, the folder access credentials have
already been configured, and the following configuration is not required.
(2) Enter the account name and password for which “MG_PLCD” folder sharing was configured
in “1. PWA-MGW1 shared folder settings.”
21
Page 22
(3) Place a check mark in the [Remember my credentials] checkbox, and click the [OK] button.
(4) Check that “archive” and “retrieve” folders appear inside the “MG_PLCD” f o l d e r.
22
Page 23
To remove access credentials settings
(1) Open [Control Panel]
(2) Click [Windows Credentials].
(3) Click the down arrow (V) to display the corresponding access credentials, and click
[Remove].
The access settings are deleted.
-> [Credential Manager].
Settings for using Submonitors
1. Right-click on the desktop and select [Screen Resolution] from the menu displayed.
2. Set [Resolutions] as follows.
• ADTECHNO CL5585H : 1280x720
• Sony CLM -V55 Clip-on LCD Monitor: 1280x768
23
Page 24
PGM2
PGM1
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
USB HDD
or ODA
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
10GbE NIC
10GbE NIC
CAM1
CAM2
Connections
Notes
• In configurations that require two MSQ-S321 boards, only PWS-100PR1/PWS-110PR1 connection is
supported.
• In the following figures, MSQ-S321 or MSQ-S321(1) refers to the lower slot and MSQ-S321(2) refers to
the upper slot.
2IN/2OUT (4K) with 10GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
24
Page 25
PGM1
PC (PWA-PRC1 installed)
PC (PWA-MGW1 installed)
Display
PWS-4500
10GbE HUB
1GbE HUB
Display
PWSK-4403
10GbE
10GbE
USB HDD
or ODA
10GbE NIC
10GbE NIC
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
CAM1
CAM2
CAM3
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
3IN/1OUT (4K) with 10GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
25
Page 26
PGM1
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
USB HDD
or ODA
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
10GbE NIC
10GbE NIC
CAM1
1IN/1OUT (4K) with 10GbE Network, without PWSK-4504
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
26
Page 27
PGM2
PC (PWA-PRC1 installed)
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
1GbE HUB
PGM1
10GbE NIC
CAM1
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
CAM2
2IN/2OUT (HD) with 1GbE Network, without PWSK-4504
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
27
Page 28
PC (PWA-PRC1 installed)
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
1GbE HUB
PGM1
10GbE NIC
CAM1
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
CAM2
2IN/1OUT (HD) with 1GbE Network, without PWSK-4504
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
28
Page 29
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
CAM2
CAM3
CAM4
CAM5
CAM6
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
PGM2
6IN/2OUT (HD) with 1GbE Network, without PWSK-4504
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
29
Page 30
PGM2
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
PGM1
10GbE NIC
CAM1
CAM2
CAM3
CAM4
PC (PWA-PRC1 installed)
PWSK-4403
Display
1GbE HUB
SDI1
SDI2
SDI3
SDI4
REF
MSQ-S321
(1)
SDI1
SDI2
SDI3
SDI4
REF
MSQ-S321
(2)
4IN/2OUT (HD) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
30
Page 31
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
CAM2
CAM3
CAM4
CAM5
CAM6
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
6IN/1OUT (HD) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
31
Page 32
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
CAM2
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
USB HDD
or ODA
10GbE NIC
10GbE NIC
PGM1
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
HFR 2IN/1OUT (4K 2x) with 10GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
32
Page 33
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
USB HDD
or ODA
10GbE NIC
10GbE NIC
PGM2
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
PGM1
HFR 1IN/2OUT (4K 2x) with 10GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
33
Page 34
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
CAM2
CAM3
CAM4
CAM5
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
PGM2
HFR 5IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
34
Page 35
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
CAM2
CAM3
CAM4
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
PGM2
HFR 4IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
35
Page 36
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
CAM2
CAM3
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
PGM2
HFR 3IN/2OUT (HD 4x, 3x, 2x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
36
Page 37
PGM1
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
SDI
1GbE Network
USB1.1
USB3.0
10GbE NIC
SDI1
SDI2
SDI3
SDI4
REF
MSQ-S321
(1)
MSQ-S321
(2)
1GbE HUB
PGM2
CAM1
CAM2
CAM3
HFR 3IN/2OUT (HD 8x, 6x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
37
Page 38
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
10GbE NIC
PGM1
CAM1
1GbE HUB
SDI
1GbE Network
USB1.1
USB3.0
CAM2
CAM3
HFR 3IN/1OUT (HD 8x, 6x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
38
Page 39
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
PC (PWA-MGW1 installed)
Display
PWS-4500
USB HDD
or ODA
10GbE NIC
1GbE HUB
SDI
1GbE Network
USB1.1
USB3.0
CAM1
CAM2
PGM1 PGM2
HFR 2IN/2OUT (HD 8x, 6x) with 1GbE Network
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 1GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
Note
For faster high-speed transfer using ISO REC, for example, connect between the server and Media
Gateway using a 10GbE network.
39
Page 40
PGM1
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
CAM2
SDI
1GbE Network
USB1.1
10GbE HUB
1GbE HUB
Display
PWSK-4403
10GbE
10GbE
10GbE Network
USB HDD
or ODA
USB3.0
10GbE NIC
10GbE NIC
Cut Out with 10GbE Network (for MSQ-S321 1pc)
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
40
Page 41
PC (PWA-MGW1 installed)
Display
PWS-4500
SDI
1GbE Network
USB1.1
10GbE HUB
1GbE HUB
10GbE
10GbE
10GbE Network
USB HDD
or ODA
USB3.0
CAM1
CAM2
10GbE NIC
10GbE NIC
PC (PWA-PRC1 installed)
SDI1
SDI2
SDI3
SDI4
REF
PWSK-4403
Display
SDI1
SDI2
SDI3
SDI4
REF
PGM1
MSQ-S321
(1)
MSQ-S321
(2)
CAM3
Cut Out with 10GbE Network (for MSQ-S321 2pcs)
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
41
Page 42
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PWS-4500
CAM1
CAM2
Display
PWSK-4403
10GbE NIC
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
PGM1
PC (PWA-MGW1 installed)
Display
10GbE HUB
1GbE HUB
10GbE
10GbE
USB HDD
or ODA
10GbE NIC
HFR + Cut Out with 10GbE Network (for MSQ-S321 1pc)
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
42
Page 43
PGM1
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
PC (PWA-MGW1 installed)
Display
PWS-4500
CAM1
SDI
1GbE Network
USB1.1
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
10GbE Network
USB HDD
or ODA
USB3.0
10GbE NIC
10GbE NIC
Cut Out with 10GbE Network, without PWSK-4504
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
43
Page 44
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
BPU4800
1GbE HUB
Display PWSK-4403
10GbE NIC
SLOT3
LIVE 1
SLOT3
RE PLAY 1
SLOT1 REPLAY
1
3
5 7
PGM1
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
BPU4800 Replay Port, Replay Port + XAVC Transcode Port
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
Notes
• SLOT2 can be used instead of SLOT3 on the BPU4800 for the SDI connection. To use SLOT2, set the
same value for the Format setting of SLOT3 and SLOT2.
• If the Character Super setting is used in PWS mode, use SLOT3.
44
Page 45
PGM1
PC (PWA-PRC1 installed)
PC (PWA-MGW1 installed)
Display
PWS-4500
10GbE HUB
1GbE HUB
Display PWSK-4403
10GbE
10GbE
USB HDD
or ODA
10GbE NIC
10GbE NIC
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
CAM1
CAM2
CAM3
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
BPU4800
10GbE NIC
10GbE Switch
Share Play
Share Play
BPU4800 XAVC Transcode Port, Replay Port + XAVC Transcode Port
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
4K server(s) Transfer IP Server 10GbE NIC IP Address
Media Gateway IP Address MGW 10GbE NIC IP Address
45
Page 46
PGM1
PC (PWA-PRC1 installed)
MSQ-S321
SDI1
SDI2
SDI3
SDI4
REF
BPU4800
1GbE HUB
Display PWSK-4403
10GbE NIC
SLOT3
LIVE 1
SLOT3
RE PLAY 1
SLOT1 REPLAY
1 3
SDI
1GbE Network
USB1.1
10GbE Network
USB3.0
BPU4800 HD Cut Out Port
PWA-PRC1 settings
[System Config] Item Setting
PRC manager Primary PRC manager IP/Port PRC manager IP Address
Notes
• SLOT2 can be used instead of SLOT3 on the BPU4800 for the SDI connection. To use SLOT2, set the
same value for the Format setting of SLOT3 and SLOT2.
• If the Character Super setting is used in PWS mode, use SLOT3.
46
Page 47
PWS-100PR1
PWS-100PR1 PWS-100MG1
1GbE Switch
10GbE Switch
10GbE Switch
Share Play Share Play
PWS-4500
PWS-4500
1GbE Network
10GbE Network
Ref. Input
Ref. Input
TCG
Tim ecode
IN
Tim ecode
IN
BNC
Ref. Video
PWS-100PR1 PWS-100MG1
1GbE Switch
10GbE Switch
10GbE Switch
Share Play
Share Play
BPU4800
PWS-4500
1GbE Network
10GbE Network
Ref. Input
Ref. Input
TCG
Tim ecode
IN
Tim ecode
IN
BNC
Ref. Video
Connection for using Share Play Function
Configuration with PWS-4500
Configuration with BPU4800 and PWS-4500
47
Page 48
Notes
• When using a Share Play connection, the reference signal for all PWS-4500/BPU4800 units must be
synchronized. Connect an external reference signal input to all PWS-4500/BPU4800 units.
• When using a Share Play connection, one PWS-4500/BPU4800 unit managed by PRC Manager is
assigned as the master to which the other units are synced. Share Play will terminate if the
PWS-4500/BPU4800 master unit is turned off during Share Play. Accordingly, during Share Play use,
do not turn off any of the PWS-4500/BPU4800 units managed by PRC Manager.
• For Share Play redundancy, configure as follows.
- Connect both connectors 1 and 2.
- Separate Share Play 1 and Share Play 2 on different network segments.
Example:
Share Play 1: 192.168.11.xx, Share Play 2: 192.168.12.xx
- If connecting to a single network switch, separate the segments using VLANs.
Recommended network switches
Manufacturer Model
Juniper J-1) EX4550-32T
J-2) EX4550-32F
J-3) QFX5100
CISCO C-1) CISCO Nexus 9332PQ QSFP+ 32 port
C-2) CISCO Nexus 9372PX QSFP+ 6port, SFP+ 48 port
C-3) CISCO Nexus 9372TX QSFP+ 6port, 10G Copper 48 port
-
Submonitor Connections
• Connection with one submonitor (PWS-100PR1/PWS-110PR1)
48
Page 49
• Connection with two submonitors (PWS-100PR1/PWS-110PR1)
Network Cable
Connect an Ethernet cable between PWS-4500/BPU4800 Network Port 1 and the Network
terminal on the PC on which this application software is installed.
Note
PWA-PRC1 does not support the use of the Network Port 2 connector of the PWS-4500/BPU4800.
SDI Input/Output
Connect between PWS-4500 and MSQ-S321 attached to PC with BNC cables.
Note
When using only one MSQ-S321 in the PWS-100PR1/PWS-110PR1, connect the SDI cables to the SDI
connectors for the lower slot.
Basic connection (MSQ-S321 × 2)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321(1)_SDI 1
Port A HD IN/OUT SDI 9 MSQ-S321(2)_SDI 1
Port B HD IN/OUT SDI 10 MSQ-S321(1)_SDI 2
Port B HD IN/OUT SDI 9 MSQ-S321(2)_SDI 2
Port C HD IN/OUT SDI 10 MSQ-S321(1)_SDI 3
Port C HD IN/OUT SDI 9 MSQ-S321(2)_SDI 3
Port D HD IN/OUT SDI 10 MSQ-S321(1)_SDI 4
Port D HD IN/OUT SDI 9 MSQ-S321(2)_SDI 4
49
Page 50
Basic connection (MSQ-S321 × 1)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321_SDI 1
Port B HD IN/OUT SDI 10 MSQ-S321_SDI 2
Port C HD IN/OUT SDI 10 MSQ-S321_SDI 3
Port D HD IN/OUT SDI 10 MSQ-S321_SDI 4
Note
When making the basic connections, even if changes are made to the PWS-4500 I/O configuration
(excluding the configuration patterns on the next page), the connection between the PWS-4500 and
MSQ-S321 does not need to change.
HFR 3IN/1OUT (HD 8x, 6x) (MSQ-S321 × 1)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321_SDI 1
Port C HD IN/OUT SDI 9 MSQ-S321_SDI 2
Port C HD IN/OUT SDI 10 MSQ-S321_SDI 3
Port D HD IN/OUT SDI 10 MSQ-S321_SDI 4
HFR 2IN/2OUT (HD 8x, 6x) (MSQ-S321 × 1)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321_SDI 1
Port C HD IN/OUT SDI 10 MSQ-S321_SDI 3
Port D HD IN/OUT SDI 9 MSQ-S321_SDI 2
Port D HD IN/OUT SDI 10 MSQ-S321_SDI 4
Cut Out (MSQ-S321 × 1), HFR + Cut Out (MSQ-S321 × 1)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321_SDI 1
Port C HD IN/OUT SDI 10 MSQ-S321_SDI 3
Port D HD IN/OUT SDI 2 MSQ-S321_SDI 2
Port D HD IN/OUT SDI 10 MSQ-S321_SDI 4
50
Page 51
Cut Out (MSQ-S321 × 2)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321(1)_SDI 1
Port B HD IN/OUT SDI 9 MSQ-S321(2)_SDI 2
Port C HD IN/OUT SDI 10 MSQ-S321(1)_SDI 3
Port D HD IN/OUT SDI 2 MSQ-S321(1)_SDI 2
Port D HD IN/OUT SDI 10 MSQ-S321(1)_SDI 4
PWS-4500 (without PWSK-4504) (2IN/2OUT, 2IN/1OUT, 1IN/1OUT)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321(1)_SDI 1
Port B HD IN/OUT SDI 10 MSQ-S321(1)_SDI 2
Port A HD IN/OUT SDI 9 MSQ-S321(1)_SDI 3
Port B HD IN/OUT SDI 9 MSQ-S321(1)_SDI 4
PWS-4500 (without PWSK-4504) (Cut Out)
PWS-4500 MSQ-S321
Port A HD IN/OUT SDI 10 MSQ-S321(1)_SDI 1
Port B HD IN/OUT SDI 10 MSQ-S321(1)_SDI 2
Port B HD IN/OUT SDI 2 MSQ-S321(1)_SDI 3
51
Page 52
Installation
This section describes the PWA-PRC1 installation procedure.
For details about PWA-PRC1 operation, refer to the User’s Guide.
Notes
• Perform installation with administrator privilege s.
• When upgrading, uninstall th e previous version before installing the new version.
Installing
1. Uninstall PWA-PRC1 V1 installed on the PWS-100PR1/PWS-110PR1.
See “To uninstall” (below) for the uninstall procedure. Do not delete the configuration
information.
2. Double-click the installer Sony_PWA-PRC1_(version).exe. Follow the instructions that
appear on the screen to complete installation.
To install a shortcut icon of PWA-PRC1 on the desktop, check [Create a desktop shortcut]
in the Setup Type screen.
To uninstall
1. Close PWA-PRC1.
2. Select [Programs and Features] in the Windows Control Panel.
3. Select [PWA-PRC1], and then click [Uninstall].
After uninstalling the program, delete settings listed below as necessary. Configuration
information is not deleted automatically.
• Settings files: C:\ ProgramData \ Sony \ PWA-PRC1 folder
Note
Destination folder may be changed according to user settings.
52
Page 53
Starting and Exiting Program
Staring PRC Manager
PRC Manager must be started beforehand in order to start PWA-PRC1.
PRC Manager is software used to manage PWS-4500/BPU4800, PWA-PRC1, and PWA-MGW1
on a network, without using an operation screen. It is included with the PWA-PRC1 installer.
Configuring auto startup when the PC boots
1. Create the following shortcut for the executable file.
C:\ Program Files\ Sony\ PWA-PRC1\ PRCManage.exe
2. Copy the created shortcut to the following file.
C:\ Users\ [user_name]\ AppData\ Roaming\ Microsoft\ Windows\ Start Menu\ Programs\ Startup
If the above procedure is completed successfully, the PRC Manager icon will appear in the task
tray when the PC boots.
Notes
• When PRC Manager is launched for the first time, a “Windows Firewall has blocked some features of this
app” message appears in the [Windows Security Alert] dialog. Click [Allow access]. Connection with
the PWS-4500 is not possible if this step is skipped.
• By default, the copy destination folder above is hidden by the system, and you cannot browse to the
folder in Windows Explorer. If this occurs, use the following procedure to enable browsing in Windows
Explorer.
1) Display the menu, and click [Folder Options…] in the [Tools] menu.
2) Click the [View] tab.
3) Click [Show hidden files, folders, and drives] in [Hidden files and folders].
To exit PRC Manager
Right-click the PRC Manager icon displayed in the notification area of the task tray, and click
[Exit] in the displayed menu.
53
Page 54
Starting PWA-PRC1
1. Turn on the computer on which PWA-PRC1 is installed, the PWSK-4403, and the server.
The [F1] to [F10] function buttons and the [ENTER] button on the PWSK-4403 are lit blue.
2. Click/tap “PWA-PRC1” on the Start screen or double-click/double-tap the “PWA-PRC1” icon
on the desktop.
When starting PWA-PRC1 for the first time:
Authentication using an install key is required.
For details, see “About Authentication” (page 55).
3. When PWA-PRC1 starts and the IP input screen appears, enter the [PRCM IP Address] and
click/tap [Set].
4. Select the PWS-4500 or BPU4800 to be the local server.
The operation screen of PWA-PRC1 appears.
When the connection with the PWS-4500 or BPU4800 is successful, the information on the
PWA-PRC1 operation screen is updated and record train recording starts.
The clip registration status is reflected in the [F1] to [F10] function buttons on the
PWSK-4403 (button is green if a clip is registered or off if no clip is registered).
Notes
• Under the default settings of the PWA-PRC1, loop recording mode is disabled. If the server is set to loop
recording mode, be sure to enable [Loop REC] in the settings screen after PWA-PRC1 starts.
• Do not change the size of text on the screen.
Exiting PWA-PRC1
1. Press the [SHIFT] button on the PWSK-4403 and then press the [D] (Settings) soft button.
The settings screen appears.
You can also press the Shift+F2 key combination on the keyboard to display the settings
screen.
2. Press the [SHIFT] button and then press the [A] (Exit App) soft button.
A confirmation message appears. Click/tap [OK] to stop record train recording and close
all ports, or click/tap [Cancel] to continue recording.
You can also click/tap the “ ” button in the top right corner of the window using a
mouse/touch panel to exit PWA-PRC1.
54
Page 55
About Authentication
When using PWA-PRC1 for the first time, an install key is required for authentication.
This procedure is not required if using the PWS-100PR1/PWS-110PR1.
Executing Authentication
The following are necessary for authentication.
• MAC address of a network interface within the PC
• A software install key for PWA -PRC1 (Ask your sales contact for details).
Notes
• A software install key is valid for one PC. If you use PWA-PRC1 on another PC, another software install
key is required.
• Whenever a network card is changed, authentication is required. This is because authentication uses
MAC address of the network card.
1. Start PWA-PRC1.
The Authentication screen appears.
2. Input a software-install-key on the Authentication screen, and then click [OK].
55
Page 56
Setting
Make the required settings for PWA-PRC1 operation.
Displaying the Settings Screen
1. Start PWA-PRC1.
2. Press the [SHIFT] button, and then the [D] (Settings) button of the PWSK-4403.
The Settings screen appears.
On a keyboard, press the Shift+F2 keys to switch between the operation screen and the
settings screen.
Using a mouse/touch panel, click/tap the [Settings] button on the operation screen.
Configuration Items
[System 1]
Category Item Description Default
value
PRC manager Primary PRC
manager IP/Port
PTP Domain Specifies the domain value (Primary,
ISC Auto
maintenance
Specifies the IP address of PRC Manager and the
port used for communications.
Note
If this setting is changed, restart PWA-PRC1.
Secondary) for Share Play (range: 0 to 127).
[Set] button: Resets the Share Play connection in
response to edited settings.
Specifies whether to enable (On) or disable (Off)
automatic PWA-ISC1 maintenance.
Configurable only when a PWA-ISC1 is
connected.
IP address:
undefined
Port No.:
51000
Primary: 100
Secondary:
101
Off
4K server(s) ― Registers information about the servers on the
network (up to 10 servers).
ID Displays the connected server ID. ―
Model Name Displays the model name. ―
Name Specifies the server name. Server ID
Local Specifies the local server (Undefined)
Push Specifies the transfer destination server when
using the push function.
―
(Undefined)
56
Page 57
Category Item Description Default
value
Control IP Specifies the IP address set for Network 1 on the
―
server.
Transfer IP Specifies the IP address for transfers. Same as
Control IP
address value
Ready Status Displays the Share Play status of the server.
Genlock Status Displays the status of the server’s four Share
―
―
Play ports (“T” for transmitter, “R” for receiver),
and indicates whether the ports are in use.
When linking is off, nothing is displayed.
When linking is on, “Stopped,” “Free Running,”
“Locking,” and “Locked” are displayed in sequence
until genlock is achieved.
Each Share Play port is displayed in green when
available.
Each Share Play port is displayed in yellow when in
use.
The server with “*” indicates the GenLock Master.
Rec control Starts/stops recording on the network server.
[Start] button: Start recording
[Stop]: Stop recording
Edit by network Enables/disables editing and deleting of clips
from the PRC1 for which the corresponding
server is a network server.
Push receive page Selects the receive page for clips transferred
using the push function (0-9, multiple selection
supported).
Network/PL clip
save page
Selects the page to register (0 to 9, multiple
selection supported), when PRC1 is connected
to a network server and a clip is created in the
cliplist managed by PRC1 from material on the
network server.
Note
If the specified page is on a local server, this setting
is configurable only from the local PWA-PRC1. If the
server is not local, this setting can be configured
from any PWA-PRC1 instance.
―
Yes
(Undefined)
(Undefined)
57
Page 58
Category Item Description Default
value
Protect pages Specifies the pages (0 to 9, multiple selection
supported) on which clips are protected.
Note
If the specified page is on a local server, this setting
is configurable only from the local PWA-PRC1. If the
server is not local, this setting can be configured
from any PWA-PRC1 instance.
Media
Gateway
IP address Selects the IP address of the Media Gateway to
use.
[Refresh] button: Acquires information about the
drives connected to Media Gateway.
Note
Click/tap the [Refresh] button in the following
cases.
Archive destination drive connection is changed
Media is exchanged
Server transfer IP is changed or deleted
Drive Selects the archive destination drive from the
list.
Push machine Selects the push function transfer destination
(Undefined)
(Undefined)
(Undefined)
(Undefined)
from the servers connected to Media Gateway.
Folder Selects the archive destination folder from a list.
[Folder] button: Sets the selected folder.
Push target ― Selects the transfer destination server for the
push function.
4K server: Selects the 4K server selected in [Push].
Other server: Selects a server connected to Media
Gateway.
Push page/bank
dialog
Sets whether to display a dialog for specifying
the page or bank when executing the push
function.
Yes: Display dialog
No: Do not display dialog
For details about other PWA-PRC1 settings, refer to the User’s Guide.
Root folder
4K server
No
58
Page 59
Appendix
Usage Precautions
SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND RESULTING FROM A FAILURE TO
IMPLEMENT PROPER SECURITY MEASURES ON TRANSMISSION DEVICES, UNAVOIDABLE
DATA LEAKS RESULTING FROM TRANSMISSION SPECIFICATIONS, OR SECURITY
PROBLEMS OF ANY KIND.
Depending on the operating environment, unauthorized third parties on the network may
be able to access the unit. When connecting the unit to the network, be sure to confirm
that the network is protected securely.
Trademarks
All system names and product names appearing in this document are registered trademarks or
trademarks of their respective owners. Trademarked items are not indicated by ® or ™
symbols in this document.
59
Page 60
The material contained in this manual consists of information that is the property of Sony
Corporation and is intended solely for use by the purchasers of the equipment described in this
manual.
Sony Corporation expressly prohibits the duplication of any portion of this manual or the use
thereof for any purpose other than the operation or maintenance of the equipment described
in this manual without the express written permission of Sony Corporation.
60
Page 61
http://www.sony.net/