-Incaseofabnormalities, the POWER/STANDBY indicator automatically blinks. It is
possible to predict the abnormality location by the number of blinks. The Instruction
Manual describes blinking of the POWER/STANDBY indicator.
-Ifthe symptom is not reproduced sometimes in case of a malfunction, there is recording of
whether a malfunction was generated or not. Operate the remote command to confirm the
matter on the screen and to predict the location of the abnormality.
2. Diagnosis Items and Prediction of Malfunction Location
-When a malfunction occurs the POWER/STANDBY indicator only blinks for one of the
following diagnosis items. In case of two or more malfunctions, the item which first
occurred blinks. If the malfunctions occurred simultaneously, the item with the lowe
blink count blinks first.
-The screen display displays the results regarding all the diagnosis items listed below.
Thedisplay "0" means that no malfunctions occurred.
Number of times
Diagnosis Item
POWER/STANDBY
indicator blinks
Power does not
turn on
0
Lamp cover error3 times
Fanstopped4 times
Lamp driver error5 times
+B OVP error
6 times
Probable Cause
Location
-Powercord is not
plugged in.
-Fuse is burned out.
(F1901:F board)
-Lampcover is not
attached securely.
Defected symptoms
-Power does not come on.
-Nopower is supplied to the
unit.
-ACpower supply is faulty.
-Nopicture/No sound
-Fan1orFan2orFan3
power is not supplied.(A
board)
-Nopicture/No sound
-Fan connector is not
attached securely.
-Temperture is high.
-IIC-E line connector
(CN8023:A
board,CN44:H3 board) is
not attached securely.
-Nopicture/No soundTemp error4times
-Lampdriver is faulty.- No picture/No sound
-+17V is not
supplied.(G1 board)
-Nopicture/No sound
-Audio line is shorted.(A,G1
board)
Audio error7 times
D-OVP error8 times
Lamp errorLAMP-LED flashes-No picture/No sound
-IC8504(A board) or
IC4704(AU board) is faulty.
- PS1601 or 1602 is
opened.(G1 board)
-+3.3V or +2.5V or +1.8V is
over voltage.(G3 board)
ThePOWER/STANDBY indicator blinking display is released by removing the plug fro
the power or leaving for 2 minutes.
LED blinks
LED ON : 0.3sec
LED OFF : 0.3sec
LED OFF
3.0sec
4. Self-diagnosis screen displays
-Incases of malfunctions where it is not possible todetermine the symptom such as when
the power goes off occasionally or when the screendisappears occasionally, there is
screen display on whether the malfunction occurred or not in the past (and whether the
detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
-Quickly press the remote command button in the following order from the standby state.
Be aware thatthisdiffers fro
the method of entering the
service mode (Vol +).
LCD ENGINE
4:TEMP0
5:LAMP DRIVER0
201 : WDT-ENGINE0
-Numeral "1" means afaultwasdetected one time or more.
-Numeral "0" means that no fault was detected.
– 9 –
KF-42WE610/50WE610/60WE610
k
r
r
m
m
KRM-Y913RM-Y913RM-Y913
-The results display is not automatically cleared. In case of repairs and after repairs, chec
the self-diagnosis screen and be sure to return the results display to "0".
-Ifthe results display is not returned to "0" it will not be possible to judge a new malfunction
after completing repairs.
<Method of Clearing Results Display>
1. Power off (Set to the standby mode)
2.ChannelVol
DISPLAY5-POWER
3. Channel
4. Wait until appearing the initial setup display.
5. Disconnect AC plug and connect it again.
<Method of Ending Self-Diagnosis Screen>
-When ending the self-diagnosis screen completely, turn the power switch OFF on the
remote commander or the main unit.
5. Self-Diagnosis function operation
-3:Lampcove
-4:FanWhen Fan1 or Fan2 or Fan3 is stopped then pin 2 or 5 or 8 of
-4:TempWhen a temperature sensor on the H3 board detects a high
8ENTER
When lamp cover SW is opened then pin 3 of CN8014 on the A
board is high, LCD Engine u-com (pin 27 of IC3208 on the C2
board) detects it and make turn off the lamp.
CN8022 on the A board is high, LCD Engine u-com (pin 24 of
IC3208 on the C2 board) detects it and make turn off the lamp.
temperature or IIC-E line connector (CN8023:A board,CN44:H3
board) is not attached securely, LCD Engine u-com IIC-E line
detects it and make turn off the lamp.
-5:Lampdrive
-6:+BOVPWhen +17V line drop then pin 53 of MAIN u-com (IC3405 on the
-7:AudioWhen DC is appeared by audioamp failure at speaker line.
-8:D-OVPWhen +3.3V or +2.5V or +1.8V line over then pin 49 of MAIN
-LAMP:LampWhen lamp is not turned on then pin 29 of LCD Engine u-co
When lamp is not turned on then pin 29 of LCD Engine u-co
(IC3208 on the C2 board) is high, checks pin 28 of LCD Engine
u-com. If pin 28 is low, it is judged no high voltage.
C2 board) is low, it turns off the main power.
Then it is detected by MAIN u-com (pin 59 of IC3405 on the C2
board) and it turns off the main power.
u-com (IC3405 on the C2 board) is low, it turns off the main
power.
(IC3208 on the C2 board) is high, checks pin 28 of LCD Engine
u-com. If pin 28 is high, it is judged lamp is burned out.