Sony IPELA NSR-500 Series Installation Manual

Network Surveillance Server
4-272-492-02 (1)
Installation Manual ________ GB
設置説明書 ________________ JP
NSR-500 Series
お買い上げいただきありがとうございます。
電気製品は安全のための注意事項を守らないと、
© 2010 Sony Corporation
Manuel d’installation ______ FR
Installationsanleitung ______ DE
Manuale all’installazione ___ IT
Manual de instalacion _____ ES
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
THIS APPARATUS MUST BE EARTHED.
IMPORTANT NOTICE
This equipment is assigned a Model No. PTOM001 for regulatory compliance certifications. The number is indicated on the model number label on your product along with the rated voltage and current.
WARNING
When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power plug to an easily accessible socket-outlet near the unit. If a fault should occur during operation of the unit, operate the disconnect device to switch the power supply off, or disconnect the power plug.
WARNING
Using this unit at a voltage other than 120 V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.
Attention-when the product is installed in Rack:
1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
2. Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection.
3. Internal air ambient temperature of the rack When this product is installed in a rack, please make sure that the internal air ambient temperature of the rack is within the specified limit of this product.
4. Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading.
5. Install the equipment while taking the operating temperature of the equipment into consideration For the operating temperature of the equipment, refer to the specifications of the Operation Manual.
6. When performing the installation, keep the following space away from walls in order to obtain proper exhaust and radiation of heat.
Right, Left : 4 cm (1.6 inches) or more Rear : 10 cm (4 inched) or more
When installing the installation space must be secured in consideration of the ventilation and service operation.
• Do not block the ventilation slots at the left side and right side panels, and vents of the fans.
• Leave a space around the unit for ventilation.
• Leave more than 40 cm of space in the rear of the unit to secure the operation area.
When the unit is installed on the desk or the like, leave at least 4 cm of space in the left and right sides. Leaving 40 cm or more of space above the unit is recommended for service operation.
2
WARNING: THIS WARNING IS APPLICABLE FOR USA ONLY. If used in USA, use the UL LISTED power cord specified below. DO NOT USE ANY OTHER POWER CORD.
Plug Cap Parallel blade with ground pin (NEMA 5-15P Configuration) Cord Type SJT, three 16 or 18 AWG
wires
Length Minimum 1.5m (4 ft .11in.),
Less than 2.5 m (8 ft .3 in.)
Rating Minimum 10A, 125V
Using this unit at a voltage other than 120V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.
WARNING: THIS WARNING IS APPLICABLE FOR OTHER COUNTRIES.
1. Use the approved Power Cord (3-core mains lead) / Appliance Connector / Plug with earthing-contacts that conforms to the safety regulations of each country if applicable.
2. Use the Power Cord (3-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere).
If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.
IMPORTANT
The nameplate is located on the bottom.
For the customers in the U.S.A.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For the State of California, USA only
Perchlorate Material - special handling may apply, Seewww.dtsc.ca.gov/ hazardouswaste/perchloratePerchlorate Material : Lithium battery contains perchlorate.
For the customers in Canada
This Class A digital apparatus complies with Canadian ICES-003.
For the customers in Europe, Australia and New Zealand
WARNING
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
GB
3
For the customers in Europe
The manufacturer of this product is Sony Corporation, 1-7-1 Konan, Minato-ku, Tokyo, Japan. The Authorized Representative for EMC and product safety is Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Germany. For any service or guarantee matters please refer to the addresses given in separate service or guarantee documents.
This apparatus shall not be used in the residential area.
For kundene i Norge
Dette utstyret kan kobles til et IT­strømfordelingssystem.
For the customers in Taiwan only
4
Table of Contents
Usage Precautions .......................... 7
Package Contents ........................... 9
Downloading Files Stored
on the NSR .................................... 10
System Requirements ................... 11
Using the CD-ROM manual ........ 11
Features and Functions................ 13
Reference Data for Installation ... 17
Preparation Steps ......................... 17
Step 1: Installation ....................... 18
Step 2: Connections ...................... 19
Step 3: Settings ............................. 21
Step 4: Verifying Operation ........ 36
Installing Patch Files .................... 37
Others ............................................ 37
I/O Port ................................... 37
Troubleshooting ...................... 39
Specifications ................................ 40
Trademarks
• “IPELA” and are trademarks of Sony Corporation.
• Other products or system names appearing in this document are trademarks or registered trademarks of their respective owners. Further, the or ® symbols are not used in the text.
Before using the unit, be sure to read “END-USER LICENSE AGREEMENT” in the User’s Guide (PDF).
• Reproduction or duplication, in whole or part, of the software or operation manual supplied with the server, as well as renting or leasing of the software without the authorization of the right holder is prohibited under copyright law.
• Sony assumes no responsibility for damages, loss of income, or any claims from a third party arising out of use of the server or supplied software.
• For complete terms and conditions of the warranty for the server, refer to the warranty card included in the package.
• The software supplied with the server cannot be used with any other servers.
• It is not possible to install any software into the equipment other than the software supplied by Sony specifically for use with the equipment.
• Note that the specifications of the server and supplied software are subjec t to change for improvement without prior notice.
Table of Contents
5
Disclaimer of liability for recorded content
Sony Corporation does not accept any liability whatsoever for any problems arising from a failure to record, or from damage or erasure of recorded content on this equipment, for any reason. This includes claims for compensation of recorded content, and for any concomitant and consequential damages. Sony Corporation will not repair, restore, or duplicate any recorded content. Your use of this product is subject to these conditions.
Table of Contents
6
Usage Precautions
Important Information About Safety
• Be sure to connect the unit to a power source that conforms fully to the electrical specifications of this unit.
• Do not coil the power cord or bundle it with other cords. Do not piggy back connections. If current ratings are exceeded, there is a risk of fire and other accidents.
• Make sure that all AC outlets and power cords are properly grounded.
• Do not use the unit with the cover or case opened or removed. Otherwise there is a risk of fire and electric shock. Do not attempt to open or remove the cover or case yourself. Always consult your supplier if opening is necessary.
Important Information About Installation
Locations for use/storage
To prolong the life of the product, avoid use or storage in the following locations.
• Locations that can become extremely hot or cold. (Be sure to use the unit that conforms fully to the specifications of this unit.)
• Locations exposed for an extended time to direct sunlight, and locations near heating appliances. (Note that the temperature in a closed car in summer can exceed +50 ºC/+122 ºF.)
• Locations with high levels of humidity or dust
• Locations subject to strong vibrations
• Locations subject to strong magnetic fields
• Locations in the vicinity of radio or TV transmitters creating a strong magnetic field
Do not stack units or place the unit on other objects that generate heat
When one unit is stacked on top of another unit, the heat generated by both units can get extremely hot. Do not stack units on top of each other or place the unit on other objects that may generate heat.
Do not block the ventilation openings
• The ventilation openings on the sides of the unit serve to prevent internal heat buildup. Always leave a clearance on both sides as well as behind and above the unit.
• Do not use the unit in a closed box or other enclosure.
Use the unit in a horizontal position
• The unit is designed to be operated in a horizontal position.
• Do not install the unit on a slanted surface, and protect the unit from shocks.
• When the unit is dropped or otherwise subject to strong shocks, it can be seriously damaged.
Maintenance
• Before cleaning the unit or performing any other kind of maintenance, be sure to disconnect the power cord from the AC outlet.
• For cleaning, lightly wipe the cabinet and panels with a dry cloth. To remove stubborn stains, lightly moisten the cloth with a mild, neutral detergent and wipe with a dry cloth afterwards.
• Do not use cleaning alcohol, solvents, benzine, insecticide, or any other volatile substances, because these may damage the finish and lead to discoloration.
Usage Precautions
7
Transport
Use the original packing material or similar packing to protect the unit from shocks.
even to very light shocks. After this period, the hard disk will be fully stopped and the unit can be manipulated.
Precautions for products with built-in HDD
This unit has a built-in hard disk drive (HDD). The HDD is a precision device. If subject to shock, vibration, static electricity, high temperature or humidity, data loss can occur. When installing and using the unit, closely observe the following precautions.
Protect from shocks and vibrations
When subject to shocks or vibrations, the HDD can be damaged and loss of data on the HDD can occur.
• When transporting the unit, use the specified packing material. When transporting on a dolly or similar, use a type which does not transmit excessive vibrations. Excessive shocks and vibrations can damage the HDD.
• Never move the unit while it is powered.
• Do not remove panels or outer parts of the unit.
• When placing the unit on a floor or other surface, make sure that the unit is equipped with the specified rubber feet, and put the unit down carefully. If there are no feet, mount the rubber feet first.
• Do not place the unit near other devices that may become a source of vibrations.
Wait for 30 seconds after turning power off
For a brief interval after the power is turned off, the platters inside the HDD will still keep spinning and the heads will be in an insecure position. During this interval, the unit is more susceptible to shocks and vibrations than during normal operation. For a period of at least 30 seconds after turning power off, avoid subjecting the unit
Temperature and humidity related precautions
Use and store the unit only in locations where the specified temperature and humidity ranges are not exceeded. (Be sure to use the unit that conforms fully to the specifications of this unit.)
When HDD seems to be faulty
Even if the HDD is showing signs of malfunction, be sure to observe all the above precautions. This will prevent further damage from occurring until the problem can be diagnosed and corrected.
Replacement of the HDD and other consumable parts
The HDD, and battery of the unit are consumable parts that will need periodic replacement. When operating at room temperature, the recommended replacement cycle is about two to three years. However, this replacement cycle represents only a general guideline and does not imply that the life expectancy of these parts is guaranteed. For details on parts replacement, contact your dealer.
Precautions for using USB devices
• This unit supports USB 2.0 Mass Storage devices. However, it does not support USB 2.0 Mass Storage HDDs or CD/ DVD drives. Do not connect mass storage devices other than USB flash memory devices to the unit. Be aware that errors may still occur when writing data to a USB 2.0 Mass Storage memory device, depending on the type of device used. If errors occur when writing data, use a USB memory device of a different type.
• To ensure proper operation of USB devices, do not connect the devices via a USB hub. Connect the devices directly to
Usage Precautions
8
the USB connectors on the unit. Operation is not guaranteed when devices are connected via a USB hub, USB switch, or extension cable.
Package Contents
Protect data from power interruptions
If the power supply is interrupted while the unit is in operation, data may be damaged. We recommend using an uninterruptible power supply (UPS).
Check that the following items are included in this package:
• NSR-500 series (1)
• HDD cover key (2)
• Installation Manual (this document) (1)
• CD-ROM (User’s Guide) (1)
• WEEE booklet (1)
• Warranty booklet (1)
• Rubber feet (4)
Notes
• This package may contain additional hardware and/or documentation for those options.
• Save the boxes and packing materials for future use.
• The system controller (RM-NS1000) is optional (sold separately).
Package Contents
9
Downloading Files Stored on
File README.txt:
Contains information on each folder.
the NSR
Documents, such as operating manuals, and tools are stored on the NSR unit. Perform the following to download files stored on the NSR unit.
1 Use an FTP client such as Internet
Explorer to specify the following URL on your computer.
ftp://ftptool@<NSR IP address>
2 Enter the following user name and
password.
User name: ftptool Password: ftptool
Note
To change the user name and password, change the [Enable user to Get Tools from Remote] configuration in “FTP” of the Setup Menu. In addition, if you change the user name, you must also change the address that follows “ftp://” in the specified URL to the new “user name@<NSR IP address>.”
The files contained in each folder are displayed.
4 Click the files you desire to download
them.
The following folders and files appear in the FTP client.
3 Click the folders that contain the files
you desire.
Folder Tool:
Contains RealShot Manager Advanced and Media File Player.
Downloading Files Stored on the NSR
10
System
Using the
Requirements
The hardware required in order to use this unit are as follows.
• Monitor
• Sony Network cameras
• USB keyboard
•USB mouse
•Network switch
• 1000Base-T/100Base-TX/10Base-T
• USB flash memory device
1) This unit supports computer displays that
2) Contact your dealer for details about
3) Use a USB keyboard with a cable. However,
4) Use a USB mouse with a cable. Wireless or
5) Required when backing up system
1)
2)
3)
4)
cable
support RGB input. The following resolutions can be specified.
- Full High-Definition (1,920 × 1,080)
- WUXGA (1,920 × 1,200)
- Full Wide XGA (1,360 × 768)
- UXGA (1,600 × 1,200)
- SXGA (1,280 × 1,024)
- XGA (1,024 × 768)
compatible Sony network cameras.
keys other than the standard may not function. Wireless or infrared USB keyboards may also not function properly.
infrared USB mice may not function properly. Functions such as three-button and wheel operations may also function improperly.
information such as logs.
- This unit supports USB 2.0 Mass Storage devices. However, it does not support USB
2.0 Mass Storage HDDs or CD/DVD drives. Do not connect mass storage devices other than USB memory devices to the unit. Be aware that errors may still occur when writing data to a USB 2.0 Mass Storage memory device, depending on the type of device used. If errors occur when writing data, use a USB flash memory device of a different type.
5)
CD-ROM manual
The supplied CD-ROM includes manuals (User’s Guide) for this unit (Japanese, English, French, German, Italian, Spanish and Simplified Chinese versions). The copies of these manuals are created in pdf (Portable Document Format).
Preparations
One of the following programs must be installed on your computer in order to use the manuals contained on the CD-ROM disc.
• Adobe Reader Version 6.0 or higher
Note
If Adobe Reader is not installed, you can download it from the following URL: http://www.adobe.com/
Adobe and Adobe Reader are trademarks of Adobe Systems Incorporated in the United States and/or other countries.
Reading the CD-ROM Manual
To read the manual on the CD-ROM, proceed as follows.
1 The manuals are saved in the Manual
folder.
The manuals are saved in the Manual folder.
2 Select and click the manual that you
want to read.
System Requirements / Using the CD-ROM manual
11
Note
Depending on the version of Adobe Reader you are using, the file may not display properly. If the file does not display properly, download the latest version of Adobe Reader from the URL found in the “Preparations” section.
Caution
If you lose the CD-ROM disc or you cannot read it for some reason, you can purchase a new CD-ROM disc. Contact your nearest Sony service representative.
Using the CD-ROM manual
12
Features and Functions
12 3 4 5
Front (When the Front Cover and the HDD Cover are Opened)
qdqs 90qaqf
A RAID LED
Lights green when the RAID configuration is functioning properly. Lights amber when there is as an internal hard disk drive failure or other problem with the RAID.
B ACCESS LED
Blinks green when the HDDs are accessed.
C HDD LEDs (1 to 6)
Light green when the internal hard disk drives are functioning properly. Light red when failures or other problem occurs. Also, light amber during the rebuilding of RAID.
D Lock
Use this in conjunction with the supplied HDD cover key to lock the HDD cover. When the HDD cover is locked, you cannot remove it.
768
When attaching the HDD cover, make sure the lock is the unlocked state before you attach the cover. You can distinguish the locked position from the unlocked position by looking at the lock, as illustrated below.
The HDD cover is locked
E Fan unit
For details on maintenance, contact your Sony dealer.
F HDDs
For details on maintenance, contact your Sony dealer.
G NETWORK LEDs (1 and 2)
Light green when there is a link to the network. Blink amber when the network is being accessed.
The HDD cover is unlocked
Features and Functions
13
H USB connectors (1 and 2)
Use this connector to connect a USB mouse, keyboard, USB flash memory, or system controller (RM-NS1000) to the unit.
If 3 seconds elapse without the power switch being pressed while the POWER LED is blinking, the unit does not turn off and operation continues.
I REC LED
Lights red when recording images.
J STATUS LED
Indicates the recognition status of USB flash memory devices. If a device is recognized, this lights green. If a device is not recognized, this lights red.
Caution
Do not remove the USB flash memory device while the LED is blinking.
K FAN LED
Lights green when the internal fan is functioning properly. Lights red when a fan failure occurs.
L SYSTEM LED
Blinks green while the unit is starting up and then changes to always on when the unit has started. During operation, this LED is lit green when the system is functioning normally. When a system error or other problem occurs, it lights red. If this LED is lit red, contact your Sony dealer.
Caution
Pressing and holding down the power switch (approximately 5 seconds) turns off the unit forcefully.
N POWER LED
Lights green when the unit is turned on. If you press the power switch during operation, the POWER LED blinks green for up to 3 seconds.
M Power switch
Press this to turn on the unit. If you press the power switch during operation, the POWER LED blinks green for up to 3 seconds. Pressing the power switch again during this time turns off the unit.
Features and Functions
14
Rear
12345
qs 90qa
A Fan
Caution
Take care not to obstruct the fan grille. If the grille is obstructed, heat may build up in the unit, leading to damage and/or fire.
B AUDIO OUT (line output) connector
(stereo)
Use these connectors to output audio to a peripheral audio device.
C AUDIO IN (microphone input)
connector (used for future expansion)
Use this connector to input audio from a peripheral audio device, such as a microphone. Plug-In Power microphones are supported.
D RS-232C 1 (UPS) connector
Use this connector to connect the control line of the uninterruptible power supply (UPS).
E RS-232C 2 connector (used for future
expansion)
Use this connector to connect analog cameras via the analog camera input cable.
F LAN connectors (1 and 2)
768
This connector cannot be used at the same time as the I RS-422/485 connector. For pin assignment details and wiring diagrams for sensor inputs, see “I/O Port” (page 37).
Use these connectors to connect 10Base-T, 100Base- TX, or 1000Base­T network cables. LAN1: Network cameras LAN2: Network cameras1) (LAN2 can only be used when using a different segment from LAN1.)
1) Connect remote clients to the network specified with the [Network Interface for Remote Client] setting (either LAN1 or LAN2) in the Server Configuration screen. For details, refer to the User’s Guide (PDF).
Caution
• Do not configure LAN connectors 1 and 2 to the same network segment.
• For details on using iSCSI storage, contact your Sony dealer.
1)
Features and Functions
15
CAUTION
• For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to the following ports.
- LAN1 connector
- LAN2 connector Follow the instructions for the above ports.
• When you connect the LAN cable of the unit to peripheral device, use a shielded-type cable to prevent malfunction due to radiation noise.
G Monitor connectors (1 and 2)
Connect a monitor to monitor connector
1.
Monitor connector 2 is for future expansion.
H USB connectors (1 and 2)
Use this connector to connect a USB mouse, keyboard, USB flash memory, or system controller (RM-NS1000) to the unit.
I RS-422/485 connector (used for
future expansion)
Use this connector to connect analog cameras via the analog camera input cable. This connector cannot be used at the same time as the E RS-232C 2 connector. For pin assignment details and wiring diagrams for sensor inputs, see “I/O Port” (page 37).
K SENSOR (sensor input) connector
Use this connector to connect the sensor input lines. For connection details and wiring diagrams for sensor inputs, see “I/O Port” (page 37).
L Power supply connector
Use this connector to connect the power cord.
J ALARM OUT (alarm output)
connector
Use this connector to connect the alarm output lines. For connection details and a wiring diagram for alarm output, see“I/O Port” (page 37).
Features and Functions
16
Reference Data for Installation
Storage Capacity for Recorded Data
You can confirm the configurations and the hard disk drive capacity of the NSR clicking [Information] in the Logon screen, and viewing the Information screen that appears. You can also confirm the actual storage capacity recorded in the [Storage] tab of the Server screen.
1) Capacities for hard disk drives are approximations based on the following equation for 1 GB: 1,000 × 1,000 × 1,000 = 1,000,000,000 bytes
2) Storage capacities are approximations based on the following equation for 1 GB: 1,024 × 1,024 × 1,024 = 1,073,740,000 bytes
2)
to which data can be
Number of Cameras
At the time of purchase, the maximum number of cameras that can be registered is
16.
Note
For details on adding cameras, contact your Sony dealer.
1)
by
Preparation Steps
Step 1: Installation (page 18)
Step 2: Connections (page 19)
Connect each device to the unit.
Step 3: Settings (page 21)
Turn on the unit.
Configure initial settings with the Setup Wizard.
Log on.
Perform registration with Easy Setup.
Configure automatic record settings.
Step 4: Verifying Operation (page 36)
Select automatically detected cameras and register them simultaneously.
Register devices manually.
If advanced configuration is necessary
Refer the User’s Guide (PDF).
Reference Data for Installation / Preparation Steps
17
Step 1: Installation
Before setting up, be sure that the location for installation provides sufficient space and strength to support the unit. For the unit weight, see “Specifications” (page 40). The dimensions for the unit are as follows.
When the front cover is opened
478 mm (19.1 in.)
400 mm (16.0 in.)78 mm (3.1 in.)
When installing the unit on a rack, use the rack mount kit designed specifically for this unit. For details on the rack mount kit, contact your Sony dealer.
Installation Without a Rack
88 mm (3.5 in.)
440 mm (17.6 in.)
400 mm (16.0 in.)
Top
TOP
440 mm (17.6 in.)
When the front cover is closed
400 mm (16.0 in.)
Attach the provided rubber feet to the unit. Place the unit upright so that the bottom surface is visible. Then affix the adhesive surfaces of the rubber feet on the bottom of the unit as illustrated below.
Remove
the film Rubber foot
400 mm (16.0 in.)
Bottom of the unit
18
Step 1: Installation
Step 2: Connections
Connect each device to the unit.
Connecting the Monitors
Connect the monitor to monitor connector
1.
Monitor
Monitor connector
Caution
When monitors are connected via a monitor switch, images may not always display. We recommend connecting monitors directly to the unit.
Connecting the Keyboard, Mouse and System Controller
Connect the devices to the USB connectors on the unit.
Example)
Keyboard
Mouse
System controller
Notes
• This unit supports RM-NS1000 system controller and IP Desktop USB controllers from CH Products. Other remote controllers are not supported. Do not connect more than one remote controller.
• When using USB devices, be sure to read
“Precautions for using USB devices” (page 8) in the “Usage Precautions”
section beforehand.
Connecting the Power Cord
Connect the power cord to the power supply connector. Attach the safety clip to prevent the power cord from disconnecting.
Step 2: Connections
19
Caution
Before installing, carefully read
“Important Information About Safety” (page 7). When using the unit in
combination with multiple NSR units, make sure that the power supply is sufficient.
Connecting to a Network
Connect to the network as follows.
Remote client
Connect LAN connector to the same network as the Windows PC being used as the remote client.
Windows PC
RealShot Manager Advanced
Client software
Network switch
LAN connecter 2
(page 10). For details on installation and connecting to the NSR, refer to the RealShot Manager Advanced Installation Guide (PDF).
• RealShot Manager Advanced client software operates on Windows computers. For details on recommended system specifications, refer to the release notes included in the install archive for RealShot Manager Advanced client software.
• When using RealShot Manager Advanced as a remote controller for the NSR, select [Client] during installation of RealShot Manager Advanced.
• When connecting to the user area network, use LAN connector 2.
• For details on NSR settings when using the RealShot Manager Advanced client software, see “Configurations for Using
RealShot Manager Advanced Client Software” (page 35).
Connecting Other Devices
Network switch
Network cameras
Connect LAN connector 1 to the same network as the network cameras.
LAN connecter 1
Connections to remote clients
When a remote client is necessary, you can use the RealShot Manager Advanced client software supplied with this unit.
• Use the version of RealShot Manager Advanced supplied with this unit. For details on how to download the installer for RealShot Manager Advanced, see
“Downloading Files Stored on the NSR”
Step 2: Connections
20
Connecting Sensor Inputs and Alarm Outputs
Connect the wires to the sensor input connector and the alarm output connector. For details, see “I/O Port” (page 37).
Connecting an Uninterruptible Power Supply (UPS)
1 Connect the UPS to the power outlet. 2 Connect the NSR to the UPS with the
supplied power cord.
3 Connect the NSR to the UPS with the
dedicated serial cable to the RS-232C 1 (UPS) connector on the rear of the NSR.
Power cord
Serial cable
Step 3: Settings
This section provides information on how to turn on the unit, and general explanations on how to register cameras and other devices.
To Power sourceUPS
Connecting an Audio Output Device
Connect the audio output device to the line output connector.
Audio cable
Turning On the Unit
When you press the power switch on the front panel of the unit, the unit turns on and the POWER LED on the front panel lights green.
When you turn on the unit for the first time, the Setup Wizard starts automatically. Continue to the following section, “Configuring Initial Settings with Setup Wizard.”
Notes
• The fan noise may be loud after turning on the unit. This is not a malfunction.
• If a forced shutdown was performed previously, the unit may take longer to start up.
To turn off the unit
After logging on to NSR, click at the top of the “Main” screen, and select [Shutdown] from the menu that appears.
Step 3: Settings
21
Also, if you press the power switch, and then press the power switch again while the POWER LED is blinking green (for up to 3 seconds), the unit begins the shutdown process and then the power turns off after several minutes.
Note
If the unit does not turn off after a while, press and hold the power switch on the front of the unit (for about 5 seconds) to force the power to turn off.
Configuring Initial Settings with Setup Wizard
This section explains the general flow of the Setup Wizard. For further details on settings, refer to “Changing Initial Settings with the Setup Menu” in the User’s Guide (PDF).
r
Click [Next].
The Setup Wizard starts automatically when you turn on the unit for the first time. You can configure the same settings afterward by accessing the logon screen, the Administration Menu, and then the Setup Menu. For details, refer to “To access the Setup Menu from the logon screen” (page 25).
When you turn on the unit, the Setup Wizard starts after the following screen appears.
Step 3: Settings
22
r
Read the user license agreement carefully, click [Accept], and then click [Next].
r
Select a display language, and click [Next].
r
Select a language for the keyboard, and click [Next].
r
Set the IP address for each server, and click [Next].
r
Select a time zone, and click [Next].
Set the date and time, and click [Next].
• When you select the [Enable NTP Server] check box, the unit acts as the NTP server for date and time synchronization.
• When you select the [Synchronize with NTP Server] check box, you can synchronize the date and time with a different NTP server.
r
Set the IP address for LAN connector 1, and click [Next].
r
r
Set the IP address for LAN connector 2, and click [Next].
Step 3: Settings
23
r
Select the audio output connector to use, and click [Next]. [HDMI] is for future expansion.
r
Set the server name, and click [Next].
r
Verify configurations, and click [Next].
r
Click [Finish] when the restart confirmation message appears.
r
The unit restarts.
r
The logon screen appears. Continue to the following section, “Logging On.”
Note
If you want to reconfigure the settings after configuring them with the Setup Wizard, you can reconfigure them from the login screen.
24
Step 3: Settings
To access the Setup Menu
1
2
from the logon screen
Click [Administration Menu].
r
Click [Setup Menu].
Installing Licenses
You can install a license on the NSR to enable registration of additional cameras. You can register up to 16 cameras under factory default conditions, but this can be increased to up to 24 cameras.
Notes
• For details on licenses, refer to the NSBK-CL05 Installation Guide (PDF).
• For details on acquiring licenses, contact your Sony dealer.
Logging On
Enter the user name and password, and click [Logon]. Default user name: admin Default password: admin
r
When logon is successful, the Camera Auto Registration dialog appears.
Notes
• Only Sony cameras will be located and registered.
• Only cameras with IP address settings that have not been changed from factory default conditions will be located and registered. To register cameras with IP addresses that have been changed, use [Easy Setup] (page 26), or return the camera IP address settings to default conditions and restart the unit.
• If you want to manually specify cameras for registration, click [No] and proceed to the next section, “Registering Cameras.”
• If you select the [Do not show this dialog box again] check box, this dialog box will not appear on subsequent startup of the software, and cameras will not be located. If you selected this check box previously and want to perform automatic camera registration again later, configure settings in the [Administration
Step 3: Settings
25
Menu] to reenable display of this dialog box. For details on the [Administration Menu], refer to the User’s Guide (PDF).
Registering Cameras
You can register cameras using one of the following methods: register cameras using Easy Setup; select cameras that were automatically detected and then register them simultaneously; or register devices manually.
Registration using Easy Setup
Follow the instructions of the wizard to configure each setting.
1 Select [Easy Setup], and click [Next].
Note
To return to the previous screen and reconfigure settings, click [Back].
The Camera Registration screen appears.
2 Select the check boxes for the
cameras you want to register, and click [OK]. The cameras are registered in the order that they appear in the list.
Images from the camera are displayed.
The Easy Setup wizard appears.
2 Register the cameras.
If you do not want to register cameras, select [Skip configuration] and click [Next], and proceed to step 3.
1 Select [Configure], and click
[Next].
Step 3: Settings
26
Click on a text string to enable text entry modification.
Note
If you clear the check box for a camera that is already registered and click the [OK] button, the registration will be canceled.
When registration completes, the following screen appears.
3 Click [Finish].
Proceed to “2 Recording Schedule”.
Duration Priority
Configures schedule recording within the limits of the storage duration entered.
Resolution Priority
Configures schedule recording using the cameras’ maximum resolution.
Automatic Alarm Record Configuration
Configures alarm recording using the cameras’ maximum resolution.
3 Configure recording settings.
If you do not want to configure recording settings, select [Skip configuration] and click [Next], and proceed to step 4.
1 Select [Configure], select the
recording method, and click [Next].
Automatic Schedule Record Configuration
Perform schedule recording using settings automatically configured based on the number of cameras and storage capacity. When you select this setting, be sure to also select [Duration Priority] or [Resolution Priority].
Notes
• Schedule recording settings are applied to all registered cameras.
• The settings configured here will overwrite any schedule recording settings already configured.
A Schedule Recording Setting screen appears.
2 Verify the automatically configured
settings, and click [OK]. You can change codec and resolution settings as necessary.
Example: When automatic schedule record configuration
Click to change a setting.
Example: When automatic alarm record configuration An estimated storage duration also appears for automatic alarm recording settings.
Step 3: Settings
27
5 Register users, and configure logon
passwords and permission settings for various functions.
If you do not want to register users, select [Skip configuration] and click [Next], and proceed to step 6.
Click to change a setting.
Proceed to “3 Layout Tour Execution”.
4 Execute the layout tour.
If you do not want to execute the layout tour, clear the [Execute Layout Tour] check box and click [Next], and proceed to step 5.
1 Select [Execute Layout Tour].
2 Click [Execute].
1 Select [Configure], and click
[Next].
The User Management screen appears.
2 Click [Add].
The Add User screen appears.
28
3 Configure each setting, and click
[OK].
3 Click [Next].
Proceed to “4 Add User”.
Step 3: Settings
User
Enter the user name that will be used to log onto the NSR. The name can be up to 32 characters long and consist of alphanumeric characters, hyphens (-), and underscores (_). User names are case sensitive.
Password
Enter the password that will be used to log onto the NSR. The password can be up to 32 characters long and consist of alphanumeric characters, hyphens (-), and underscores (_). Passwords are case sensitive.
Confirm Password
Reenter the same password for confirmation.
User Level
Select the permission level to grant the user. For details on user levels and permissions, refer to the User’s Guide (PDF).
The user is added to the list in the User Management screen.
4 Click [OK].
6 Configure settings for opening the port
to external networks.
These settings are required to access the NSR from an external network.
If the router supports the UPnP function, you can use the UPnP function to configure the router settings.
• This setting allows all of the setting items will be configured automatically via UPnP. If you want to specify port numbers manually, refer to the User’s Guide (PDF).
• Router configuration is not necessary if the UPnP function is used.
If you are not using a broadband router with UPnP support, or if you are not using the UPnP function, click [Server Configuration] in the [Administration Menu], click [NAT Setting], and then configure the settings in the [NAT Setting] dialog box that appears. For details, refer to the User’s Guide (PDF). These settings are not required if you do not intend to access the system from an external network. Select [Skip configuration] and click [Next], and proceed to step 7 in such cases.
Proceed to “5 Open Ports for External Network”.
1 Select [Configure].
Step 3: Settings
29
2 Click [Send request to router].
3 Click [Next].
1) For details on router security settings, refer to the operating instructions for the routers, or contact the manufacturer of each router.
2) Changing the password does not guarantee prevention of log on by unauthorized users.
3) Sony Corporation is not liable for any loss of profits incurred by the customer as a result of such occurrences. The customer is responsible for configuring appropriate settings and measures.
The Complete screen appears.
Caution
• To ensure Internet (WAN side) security, be sure to use the firewall function on your router or similar device, and confirm that the security for the configured port is enabled.
1)
• If security is not enabled via the router or similar device, there is a risk of the NSR being accessed by unauthorized users via the WAN side ports. To maintain security, change the password regularly and configure other related settings.
2)
For details on changing the password, refer to the User’s Guide (PDF).
• If unauthorized users log onto the NSR, there is a risk of the following.
3)
- The NSR settings may be
changed.
- Images from cameras and
recorded images may be viewed and operated.
• Depending on your router and operating environment, connection from an external network may be disabled.
7 Click [OK].
This completes Easy Setup.
Proceed to “Configuring automatic record settings” (page 34).
Selecting automatically detected cameras and registering them simultaneously
Automatically detect devices on the same segment of the network as the NSR, select the cameras to register, and then register them simultaneously. You can also configure the IP addresses and port numbers of the cameras during registration. Entering the administrator ID and password of cameras enables you to register the devices.
30
Step 3: Settings
Loading...
+ 218 hidden pages