Before Starting Adjustment ·······················································6-1
1-1. Adjusting Items When Replacing
Main Parts and Boards ····················································6-2
6-1. Camera Section Adjustments··········································· 6-3
1-1. Preparations Before Adjustments ····································6-3
1-1-1.List of Service Tools ························································6-3
1-1-2.Preparations ·····································································6-4
1-1-3.Precautions ······································································6-5
1.Setting the Switch····························································6-5
3.Preparing the Flash Adjustment Box·······························6-6
1-1-4.Using Method of SEUS ···················································6-7
2.Operation ·········································································6-7
1-1-5.Precaution on Use of SEUS·············································6-7
1-2. Adjustment Programs ······················································6-8
1-2-1.Automatic Adjustment Program ······································ 6-8
1.Precautions When Using Automatic Adjustment
Program ···········································································6-8
2.Start of Automatic Adjustment Program ·························6-8
3.Function of Each Button on Main Menu Screen ·············6-8
1-2-2.Color Shading Adjustment Program································6-9
Program ···········································································6-9
4.Starting Method of Color Adjustment
Program ···········································································6-9
5.Screen and Function of Each Button of
Color Adjustment Program ··············································6-9
1-3. Video System Adjustments ············································6-10
1-3-1.Function of Each Button on Video System
Adjustment Screen ························································6-10
1-3-2.Adjustment Items of Video System Adjustment············6-10
1-3-3.Adjusting Method·························································· 6-11
1-4. Camera System Adjustments·········································6-12
1-4-1.Function of Each Button on Camera System
Adjustment Screen ························································6-12
1-4-2.Adjustment Items of Camera System Adjustment ········6-13
1-4-3.Adjusting Method·························································· 6-14
1.Wide Limit Adjustment ·················································6-14
1-1. Adjusting method when the lens is replaced: ················6-14
1-2. Adjusting method when replacement of lens
is not required and the SY-112 board is replaced: ·········6-14
10.Camera Adjustment 5 ····················································6-24
1-5. LCD System Adjustments ·············································6-25
1-5-1.Function of Each Button on LCD System
Adjustment Screen ························································6-25
1-5-2.Adjustment Items of LCD System Adjustment·············6-25
1-5-3.Adjusting Method·························································· 6-26
1-6. Error···············································································6-27
1-6-1.Error Message································································6-27
5.Data Save Error ·····························································6-28
1-6-2.Precautions When an Error Occurred····························6-28
1-7. Initialization of Data······················································6-29
1.Initializing All Page Data ··············································6-29
2.Initializing Single Page Data ·········································6-29
6-2. Service Mode·································································6-30
1.Setting the Test Mode ····················································6-30
2.Bit Value Discrimination ···············································6-30
* The AF illumination axis frame is shown on page 6-33.
DSC-T3
— 2 —
Before starting adjustment
EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.
SECTION 6
ADJUSTMENTS
(Machine before starting repair)
Save the EVR data
to a personal computer.
Procedure 2
When the data cannot be saved due to defective flash memory, or when the flash memory cannot be removed or
installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired)
PC
Save the data.
PC
Download the saved
data to a machine.
Download the data.
(Machine after a board is replaced)
(Machine to be repaired)PC
(The same model of the same destination)
After the EVR data is saved and downloaded, check the
respective items of the EVR data.
(Refer to page 6-2 for the items to be checked.)
DSC-T3
6-1
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Note 1: The automatic Adjustment Program does not support the “Initialization of data” and “Wide Limit Adjustment”. Perform them
manually.
Note 2: Use the Color Adjustment Program (T3ColorAdjustment.exe).
Replaced parts
BlockMounted partsBoard
replacementreplacementreplacement
Adjusting itemAdjustment
(Note 1)Initialization of data
VIDEO adjustmentVideo output level adj.
(Note 1)Wide limit adj.
CAMERA adjustment 1Flange back adj.
CAMERA adjustment 2Flange back check
F No. compensation
CAMERA adjustment 3
(Note 2)
CAMERA adjustment 4
CAMERA adjustment 5
LCD adjustment
Mechanical shutter adj.
Light value adj.
AWB 3200K-5800K standard data input
Color reproduction adj.
Color reproduction check
CCD linearity check
CCD white defect compensation check
CCD black defect compensation check
Strobe adj.
Auto focus illumination check
VCO adj.
Contrast adj.
V-COM adj.
Sample-hold position adj.
White balance adj. (1)
White balance adj. (2)
CCD block
Lens device
LCD unit
LCD901
Xenon tube
LCD block
(RGB drive, Timing gen.) (LCD)
(AF illmination LED)
(Timing gen., S/H, AGC, A/D conv.)
(Camera DSP)
(Video amp.)
Back light unit
IC002
D003
IC151
IC301
IC302
LCD block
MS-248 board
ST-113 board
SY-112 board
SY-112 board
SY-112 board
(COMPLETE)
(COMPLETE)
(COMPLETE)
MS-248 board
ST-113 board
SY-112 board
z
zzz
zz
zzz
zzz
z
z
z
z
zzzz
zzzz
zzzz
z
z
z
zz
zzzz
z
z
z
z
zz
zz
DSC-T3
Table 6-1-1
6-2
6-1. CAMERA SECTION ADJUSTMENTS
Personal computer
(Note 1)
J-1
J-10
J-9
J-7
HASP key and application
for adjustment (SEUS)
Contact our service headquater of each area
how to get the application for adjustment
(SEUS) and HASP key.
J-2
Pattern box PTB-450
J-6082-200-A
or
Small pattern box
PTB-1450
J-6082-557-A
J-4
Clear chart
For PTB-450:
J-6080-621-A
For PTB-1450:
J-6082-560-A
J-6
Minipattern box
J-6082-353-B
Siemens star chart
J-6080-875-A
Back ground paper
J-2501-130-A
9 colors chart (Note 2)
For PTB-1450:
J-6082-562-A
J-5
J-8
Flange back
adjustment jig
J-6082-563-A
USB cable
1-827-754-11
J-3
Cyber-shot Station
UC-TC
1-818-878-11
J-11
Tripod camera holder
2-187-260-01
J-12
1-1.PREPARATIONS BEFORE ADJUSTMENTS
1-1-1. List of Service Tools
• Oscilloscope• Color monitor• AC power adapter
Note1: Personal computer
OS:Windows98/98SE/Me/2000/XP Home/XP Pro
RAM: 256MB or more recommended
USB:2.0 recommended (also compatible with 1.1)
Note2: In using the 9 colors chart on the pattern box PTB-450, adjust the chart size through the procedure shown below so that it
matches to the pattern box PTB-450.
1) Prepare a woody board A of the thickness 5 mm, and paint it mat-black.
2) Fit the 9 colors chart in the woody board A, and secure the chart with a black tape, etc. to shield the light.
Two connectors are requir ed.
woody boad A
360 mm
155 mm
135 mm
Fig. 6-1-1
280 mm
woody boad A
DSC-T3
Fig. 6-1-2
6-3
9 colors chart
1-1-2. Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
Pattern box
Front of the lens
L=About 10 cm
Tripod camera holder
(2-187-260-01)
L
Cyber-shot Stastion
UC-TC
(1-818-878-11)
Fig. 6-1-3
Insert the Memory Stick.
Cyber-shot Station
UC-TC (Note)
(1-818-878-11)
To A/V OUT
jack
To USB
connector
Tripod camera holder
(2-187-260-01)
To DC IN jack
AC power adaptor
HASP Key
Video (yellow)
Audio (Black)
USB cable
(1-827-754-11)
Color monitor
PC
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended
(also compatible with 1.1)
Two connectors are required.
AC IN
To USB
connector
Note: When performing “CAMERA Adjustment 1”, connect the cables after disassembling the Cyber-shot Station UC-TC.
Unless the Cyber-shot Station UC-TC is disassembled, the USB cable and the power cable will interfere with the mini pattern
box or flange back adjustment jig, and thus the subject cannot be set correctly.
Fig. 6-1-4
DSC-T3
6-4
1-1-3. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments.
1. Mode switch....................................... CAMERA
2. ZOOM switch .................................... WIDE end
3. Video Out (SET UP setting).............. NTSC
4. Digital Zoom (SET UP setting)......... Off
5. Camera (Menu items) ........................ Auto
9 colors chart (Standard picture frame)
A
Green
Cyan
C14
Effective picture frame
LCD screen or under scan
Fig. a
monitor TV picture
B
Yellow
White
Blue
W14
Red
Magenta
A
A
2
2. Subjects
1) 9 colors chart (Standard picture frame).
When performing adjustments using the 9 colors chart, adjust
the picture frame as shown in Fig. 6-1-5. (Standard picture
frame)
2) Clear chart (Standard picture frame)
Remove the 9 colors chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during this time)
C
B
C
A = B
C =
C14 : Filter for AWB 5800K adjustment
Transparent window
Fig. 6-1-5
B
3
Adjust the camera position and direction
to obtain the LCD screen or the monitor
TV display shown in Fig. a.
DSC-T3
6-5
3. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2)
400 mm
513 mm513 mm700 mm
woody board B (2)
Fig. 6-1-6
2) Apply black mat paint to one side of woody board A and B.
3) Attach backgr ound paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
370 mm
700 mm730 mm
woody board A
woody board C (1)
700 mm
woody board B
woody board A
DSC-T3
woody board B
woody board C
Fig. 6-1-7
6-6
1-1-4. Using Method of SEUS
The application for adjustment (SEUS) is used to change the coefficient for calculating the signal processing or EVR data. The SEUS
performs two-way communication between PC and set through
the USB terminal. The two-way communication result data can be
written to the nonvolatile memory.
1. Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and set with the USB cable.
3) Confirm that the set starts in the USB mode.
4) Start the SEUS on the PC.
5) Click [Connect] on the SEUS screen. If the connection is normal, the SEUS screen will be as shown in Fig. 6-1-8, indicating the
“connected”state.
Note: The SEUS will go in
turned off (for instance, by resetting the set). In such a
case, click [Connect] on the SEUS screen to restore
the
“connected”state.
“disconnect" state, if the set is
2. Operation
• Page change
To change the page, click [Page] on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
notation.
• Address change
To change the address, click [Address] on the SEUS screen and
enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click [Set] on the SEUS screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory .
• Data saving
To write the all changed data to the nonvolatile memory, click
[Save] on the SEUS screen and wait for more than 3 sec.
• Data reading
The data displayed on the SEUS screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click
[Read] on the SEUS screen and update the displayed data.
1-1-5. Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking [Page Edit] on the SEUS screen before starting the adjustment.
Fig. 6-1-8
Saving Method:
1) Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click [Page], and enter the page number to be saved.
3) Click [Page] to read the data to be saved from the camera.
4) Click [File] and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click [Page Edit] on the SEUS screen to display the SEUS
PAGE EDIT screen.
3) Click [File] and load the data from PC.
4) Click [Write] on the SEUS PAGE EDIT screen.
5) Click [Close] to close the SEUS PAGE EDIT screen.
6) Click [Save] on the SEUS screen.
7) Wait for more than 3 sec.
8) Select page: 80, address: 30, and check that the data is “00”.
9) Select page: 00, address: 01 and set data: 00.
DSC-T3
6-7
1-2.ADJUSTMENT PROGRAMS
The DSC-T3 is adjusted with the Automatic Adjustment Program
and the Color Adjustment Program.
The Automatic Adjustment Program automatically controls the
adjustment operations that were formerly entered manually on the
operation screen of the SEUS (some adjustments may be manually operated on the SEUS operation screen).
The Color Adjustment Program automatically performs “AWB
3200K-5800K Standard Data Input”, “Color Reproduction Adjustment” and “Color Reproduction Check” of Camera System Adjustment.
1-2-1. Automatic Adjustment Program
1. Precautions When Using Automatic Adjustment
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communication with the camera via the SEUS. Accordingly, the Automatic Adjustment Program must be used in the environment
where the SEUS operates.
2) The program run time may vary depending on the environ-
ment of the personal computer used.
3) Even if the Automatic Adjustment Program is used without
starting the SEUS, the SEUS will start automatically when the
adjustment is executed. Howe ver, it may tak e time for the SEUS
to start, and therefore the Automatic Adjustment Program
should be used with the SEUS started in order to reduce the
program run time.
2. Start of Automatic Adjustment Program
Double-click the application file (DSC-T3 Auto-Adj
Ver_1.[]r
Note:[] (numeric value) of the file name v ar ies depending on the
[][]
.exe), and the Automatic Adjustment Program will start.
version of Automatic Adjustment Program.
3. Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-9 will appear. On this screen, select each adjustment section.
5
1
2
3
4
Fig. 6-1-9
1 [VIDEO SYSTEM ADJUSTMENT] button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
2 [CAMERA SYSTEM ADJUSTMENT] button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
3 [LCD SYSTEM ADJUSTMENT] button
The “LCD SYSTEM ADJUSTMENT” screen appears.
4 [END] button
The Automatic Adjustment Program finishes.
5 This part indicates the version of Automatic Adjustment Pro-
gram.
DSC-T3
6-8
1-2-2. Color Adjustment Program
1. Application Environment
OS:Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
5. Screen and Function of Each Button of Color
Adjustment Program
4
1
2. Installation Method
Extract the file compressed in the ZIP format (T3Color
Adjustment.zip). Execute the extracted file (setup.exe), and the
installer will start. Install the program following the instructions
given on the installer screen.
3. Notes When Using the Color Adjustment Program
1) The SEUS must be installed in the PC.
2) The HASP Key for SEUS must be connected to the USB connector. The program will not start unless the HASP Key is
connected.
4. Starting Method of Color Adjustment Program
Click the [Start] button on the task bar, and click the [DSC- T3
Color Adjustment] from the [Programs], and the program will
start.
2
3
5
A
Fig. 6-1-10
1 [Connect] button
Makes connection to the camera and switches the camera to
the adjustment mode. In the case of successful connection to
the camera, the indication at the part A changes to “Connected”
and the following buttons become active.
• [AWB 3200K-5800K Standard Data Input] button
• [Color Reproduction Adjustment] button
• [Color Reproduction Check] button
• [Disconnect] button
2 Adjustment start buttons
Start the adjustment or checking of respective button names.
3 [Disconnect] button
Cancels the connection to the camera.
4 Captured picture display screen
Displays a picture captured by the camera when the adjustment or checking was performed.
5 Vector scope screen
Displays the result of Color Reproduction Check.
DSC-T3
6-9
1-3.VIDEO SYSTEM ADJUSTMENTS
1-3-1. Function of Each Button on Video System
Adjustment Screen
Click the
Menu screen, and the “VIDEO SYSTEM ADJUSTMENT” screen
in Fig. 6-1-11 will appear.
1 [To Menu] button
2 [VIDEO Adjustment Start] button
[VIDEO SYSTEM ADJUSTMENT] button on the Main
1
2
43
Fig. 6-1-11
The Main Menu screen comes back.
“Video Adjustment” starts.
1-3-2. Adjustment Items of VIDEO System
Adjustment
The adjustment items of video system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program executes the adjustment items if the VIDEO Adjustment Start button is clicked.
Button
Name
VIDEOVIDEO Output
Adjustment Level Adj.
AdjustmentSignal PageAddress
Arbitrary 8F D0
Table 6-1-2
3 [Reset] button
This button functions same as the Reset button of the camera.
4 [Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the video adjustment. If the adjustment completed successfully, the data setting is automatically cancelled and the button color returns to
“white”.)
DSC-T3
6-10
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.