As for the places which need special attentions,
they are indicated with the labels or seals on the
cabinet, chassis and parts. Make sure to keep the
indications and notices in the operation manual.
2. AVOID AN ELECTRIC SHOCK
There is a high voltage part inside. Avoid an
electric shock while the electric current is
flowing.
3. USE THE DESIGNATED PARTS
The parts in this equipment have the specific
characters of incombustibility and withstand
voltage for safety. Therefore, the part which is
replaced should be used the part which has
the same character.
Especially as to the important parts for safety
which is indicated in the circuit diagram or the
table of parts as a mark, the designated
parts must be used.
4. PUT PARTS AND WIRES IN THE
ORIGINAL POSITION AFTER
ASSEMBLING OR WIRING
There are parts which use the insulation
material such as a tube or tape for safety, or
which are assembled in the condition that
these do not contact with the printed board.
The inside wiring is designed not to get closer
to the pyrogenic parts and high voltage parts.
Therefore, put these parts in the original
positions.
5. TAKE CARE TO DEAL WITH THE
CATHODE-RAY TUBE
In the condition that an explosion-proof cathoderay tube is set in this equipment, safety is
secured against implosion. However, when
removing it or serving from backward, it is
dangerous to give a shock. Take enough care to
deal with it.
6. AVOID AN X-RAY1. KEEP THE NOTICES
Safety is secured against an X-ray by considering about the cathode-ray tube and the high
voltage peripheral circuit, etc.
Therefore, when repairing the high voltage peripheral circuit, use the designated parts and
make sure not modify the circuit.
Repairing except indicates causes rising of high
voltage, and it emits an X-ray from the cathoderay tube.
PERFORM A SAFETY CHECK AFTER
7.
SERVICING
Confirm that the screws, parts and wiring which
were removed in order to service are put in the
original positions, or whether there are the
portions which are deteriorated around the
serviced places serviced or not. Check the
insulation between the antenna terminal or
external metal and the AC cord plug blades.
And be sure the safety of that.
(INSULATION CHECK PROCEDURE)
1.
Unplug the plug from the AC outlet.
2.
Remove the antenna terminal on TV and turn
on the TV.
3.
Insulation resistance between the cord plug
terminals and the eternal exposure metal
[Note 2] should be more than 1M ohm by
using the 500V insulation resistance meter
[Note 1].
4.
If the insulation resistance is less than 1M
ohm, the inspection repair should be
required.
[Note 1]
If you have not the 500V insulation
resistance meter, use a Tester.
[Note 2]
External exposure metal: Antenna terminal
Earphone jack
HOW TO ORDER PARTS
Please include the following informations when you order parts. (Particularly the VERSION LETTER.)
1. MODEL NUMBER and VERSION LETTER
The MODEL NUMBER can be found on the back of each product and the VERSION LETTER can be
found at the end of the SERIAL NUMBER.
2. PART NO. and DESCRIPTION
You can find it in your SERVICE MANUAL.
IMPORTANT
Inferior silicon grease can damage IC's and transistors.
When replacing an IC's or transistors, use only specified silicon grease (YG6260M).
Remove all old silicon before applying new silicon.
BBENo
Auto SearchNo
CH AllocationNo
SAPYes
Channel LockNo
Just Clock FunctionNo
Game PositionNo
CH LabelYes
VM CircuitNo
Full OSDNo
PremiereNo
Comb FilterYes
2 Lines
Auto CH MemoryYes
Hotel LockNo
Closed CaptionYes
Stable SoundYes
FBT Leak Test ProtectYes
Favorite CHYes
1 Tuner P-in-PYes
2 Tuner P-in-PNo
G-12AccessoriesOwner's ManualLanguageEnglish
W/ WarrantyYes
Remote Control UnitYes
Rod AntennaNo
Poles
Terminal
Loop Antenna
Terminal
U/V Mixer
DC Car Cord (Center+)
Guarantee Card
Warning Sheet
Circuit Diagram
Antenna Change Plug
Service Facility List
Important Safety InstructionYes
Dew/AHC Caution Sheet
AC Plug Adapter
Quick Set-up Sheet
BatteryYes
UM size x pcsUM4 size x 2
OEM Brand
AC Cord
AV Cord (2Pin-1Pin)
Registration Card (NDL Card)Yes
ESP CardYes
PTB Sheet
300 ohm to 75 ohm Antenna Adapter
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
GENERAL SPECIFICATIONS
G-13InterfaceSwitchFrontPowerYes
RearAC/DCNo
IndicatorPowerYes
TerminalsFrontVideo Input
RearVideo Input(Rear1)
G-14Set SizeApprox. W x D x H (mm) 650 x 500.5 x 560
G-15WeightNet (Approx.)35kg
Read the following NOTED items before starting work.
*
After turning the power off there might still be a potential
voltage that is very dangerous. When removing the
Anode Cap, make sure to discharge the Anode Cap's
potential voltage.
*
Do not use pliers to loosen or tighten the Anode Cap
terminal, this may cause the spring to be damaged.
REMOVAL
1. Follow the steps as follows to discharge the Anode Cap.
(Refer to Fig. 1-1.)
Connect one end of an Alligator Clip to the metal part of a
flat-blade screwdriver and the other end to ground.
While holding the plastic part of the insulated Screwdriver,
touch the support of the Anode with the tip of the
Screwdriver.
A cracking noise will be heard as the voltage is discharged.
GND on the CRT
3. After one side is removed, pull in the opposite direction to
remove the other.
NOTE
Take care not to damage the Rubber Cap.
INSTALLATION
1. Clean the spot where the cap was located with a small
amount of alcohol. (Refer to Fig. 1-3.)
Location of Anode Cap
Fig. 1-3
NOTE
Confirm that there is no dirt, dust, etc. at the spot where
the cap was located.
2.3.Arrange the wire of the Anode Cap and make sure the
wire is not twisted.
Turn over the Rubber Cap. (Refer to Fig. 1-4.)
Screwdriver
Alligator Clip
GND on the CRT
Flip up the sides of the Rubber Cap in the direction of the
2.
arrow and remove one side of the support.
(Refer to Fig. 1-2.)
Rubber Cap
CRT
Support
Support
CRT
Fig. 1-1
Fig. 1-2
Fig. 1-4
4. Insert one end of the Anode Support into the anode button,
then the other as shown in Fig. 1-5.
Support
CRT
5.6.Confirm that the Support is securely connected.
Put on the Rubber Cap without moving any parts.
Fig. 1-5
DISASSEMBLY INSTRUCTIONS
2.
REMOVAL AND INSTALLATION OF
FLAT PACKAGE IC
REMOVAL
Put the Masking Tape (cotton tape) around the Flat
1.
Package IC to protect other parts from any damage.
(Refer to Fig. 2-1.)
NOTE
Masking is carried out on all the parts located within
10 mm distance from IC leads.
When IC starts moving back and forth easily after
3.
desoldering completely, pickup the corner of the IC using
a tweezers and remove the IC by moving with the IC
desoldering machine. (Refer to Fig. 2-3.)
NOTE
Some ICs on the PCB are affixed with glue, so be
careful not to break or damage the foil of each IC
leads or solder lands under the IC when removing it.
Blower type IC
desoldering
machine
Masking Tape
(Cotton Tape)
Heat the IC leads using a blower type IC desoldering
2.
IC
machine. (Refer to Fig. 2-2.)
NOTE
Do not add the rotating and the back and forth
directions force on the IC, until IC can move back and
forth easily after desoldering the IC leads completely.
Blower type IC
desoldering machine
Fig. 2-1
Tweezers
IC
Peel off the Masking Tape.4.
Absorb the solder left on the pattern using the Braided
5.
Shield Wire. (Refer to Fig. 2-4.)
NOTE
Do not move the Braided Shield Wire in the vertical
direction towards the IC pattern.
Fig. 2-3
Braided Shield Wire
Soldering Iron
IC
Fig. 2-2
IC pattern
Fig. 2-4
DISASSEMBLY INSTRUCTIONS
INSTALLATION
Take care of the polarity of new IC and then install the
1.
new IC fitting on the printed circuit pattern. Then solder
each lead on the diagonal positions of IC temporarily.
(Refer to Fig. 2-5.)
Soldering Iron
Solder temporarily
Supply the solder from the upper position of IC leads
2.
Solder temporarily
sliding to the lower position of the IC leads.
(Refer to Fig. 2-6.)
Fig. 2-5
When bridge-soldering between terminals and/or the
4.
soldering amount are not enough, resolder using a Thintip Soldering Iron. (Refer to Fig. 2-8.)
Thin-tip Soldering Iron
IC
Fig. 2-8
Finally, confirm the soldering status on four sides of the
5.
IC using a magnifying glass.
Confirm that no abnormality is found on the soldering
position and installation position of the parts around the
IC. If some abnormality is found, correct by resoldering.
NOTE
When the IC leads are bent during soldering and/or
repairing, do not repair the bending of leads. If the
bending of leads are repaired, the pattern may be
damaged. So, be always sure to replace the IC in this
case.
Soldering IronSolder
IC
Absorb the solder left on the lead using the Braided
3.
Supply soldering
from upper position
to lower position
Shield Wire. (Refer to Fig. 2-7.)
NOTE
Do not absorb the solder to excess.
Soldering Iron
IC
Braided Shield Wire
Fig. 2-6
Fig. 2-7
SERVICE MODE LIST
This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily.
To enter the Service Mode, press both set key and remote control key for more than 1 second.
Set KeyRemocon KeyOperations
VOL. (-) MIN
0
Releasing of V-CHIP PASSWORD.
VOL. (-) MIN1
VOL. (-) MIN6
VOL. (-) MIN8
VOL. (-) MIN
9
Initialization of the factory.
NOTE: Do not use this for the normal servicing.
POWER ON total hours is displayed on the screen.
Refer to the "CONFIRMATION OF USING HOURS".
Can be checked of the INITIAL DATA of MEMORY IC.
Refer to the "NOTE FOR THE REPLACING OF MEMORY IC".
Writing of EEPROM initial data.
NOTE: Do not use this for the normal servicing.
Display of the Adjustment MENU on the screen.
Refer to the "ELECTRICAL ADJUSTMENT" (On-Screen Display Adjustment).
CONFIRMATION OF USING HOURS
POWER ON total hours can be checked on the screen. Total hours are displayed in 16 system of notation.
1.
Set the VOLUME to minimum.
2.
Press both VOL. DOWN button on the set and Channel
button (6) on the remote control for more than 1 second.
3.
After the confirmation of using hours, turn off the power.
ADDRESSDATA
INIT 00 83
CRT ON
0010
FIG. 1
Initial setting content of MEMORY IC.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)
NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
+0+1+2+3+4+5+6+7+8+9
A9C3373031B327172B80
00F4C40000005F
0F8928802740834300
10
20
30
40
50
Enter DATA SET mode by setting VOLUME to minimum.
1.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 1 second.
2.
ADDRESS and DATA should appear as FIG 1.
ADDRESS is now selected and should "blink". Using the VOL. UP/DOWN button on the remote, step through the
3.
ADDRESS until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
4.
Again, step through the DATA using VOL. UP/DOWN button until required DATA value has been selected.
5.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
6.
Repeat steps 3 to 6 until all data has been checked.
7.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
8.
The unit will now have the correct DATA for the new MEMORY IC.
00
672A6B6C6D6E6F7071
69
557556567676575777
75
59795A5A7A7A5B5B7B
79
5D7D5E5E7E7E5F5F5F
7D
Table 1
+A
+B+C+D+E+FINI
100E61636426
527253735474
775858787859
7B5C5C7C7C5D
7F7F------------
ELECTRICAL ADJUSTMENTS
1.
ADJUSTMENTS
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
•
Use an isolation transformer when performing any
service on this chassis.
•
Before removing the anode cap, discharge electricity
because it contains high voltage.
•
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
Inferior silicon grease can damage IC's and transistors.
•
When replacing IC's and transistors, use only specified
silicon grease.
Remove all old silicon before applying new silicon.
Prepare the following measurement tools for electrical
adjustments.
1. Oscilloscope
2. Digital Voltmeter
3. AC Voltmeter
On-Screen Display Adjustment
In the condition of NO indication on the screen.
1.
Press the VOL. DOWN button on the set and the
Channel button (9) on the remote control for more than
1 second to appear the adjustment mode on the screen
as shown in Fig. 1-1.
TV
00 OSD 15
Fig. 1-1
2.
Use the Channel UP/DOWN button or Channel button
(0-9) on the remote control to select the options shown
in Fig. 1-2.
3.
Press the MENU button on the remote control to end
the adjustments.
2. BASIC ADJUSTMENTSBEFORE MAKING ELECTRICAL
2-1: CONSTANT VOLTAGE
1.
Set condition is AV MODE without signal.
2.
Connect the digital voltmeter to TP002.
3.
Adjust the VR502 until the digital voltmeter is 135 ± 0.5V.
2-2: RF AGC
1.
Receive the VHF LOW (61dB).
2.
Connect the digital voltmeter between the TP001 and
the GND.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (02) on the remote control to
select "RF. AGC".
4.
Press the VOL. UP/DOWN button on the remote
control until the digital voltmeter is 2.4V.
2-3: CUT OFF
1.
Adjust the unit to the following settings.
G. DRIVE=64, B. DRIVE=64, R. BIAS=15, G. BIAS=15,
B. BIAS=15, BRIGHT=75, UNI COLOR=64
2.
Place the set with Aging Test for more than 15 minutes.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (01) on the remote control to
select "CUT OFF".
4.
Adjust the Screen Volume until a dim raster is obtained.
2-4: WHITE BALANCE
NOTE: Adjust after performing CUT OFF adjustment.
1.
Place the set with Aging Test for more than 10 minutes.
2.
Receive the white 100% signal from the Pattern
Generator.
3.
Using the adjustment control, set the brightness and
contrast to normal position.
4.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (13) on the remote control to
select "R. BIAS".
5.
Using the VOL. UP/DOWN button on the remote control,
adjust the R. BIAS.
6.
Press the CH. UP/DOWN button on the remote control to
select the "G. DRV", "B. DRV", "G. BIAS" or "B. BIAS".
7.
Using the VOL. UP/DOWN button on the remote control,
adjust the G. DRV, B. DRV, G. BIAS or B. BIAS.
8.
Perform the above adjustments 6 and 7 until the white
color is looked like a white.
TRAPEZIU
COR TOP
COR BTM
V EHT
H EHT
FM. LVL
LEVEL
SEP1
SEP2
T. STE
V POS U
V POS L
H POS L
H POS R
H. SIZE
V. SIZE
H. POSI
R
G
B
BRI
COL
TINT
VCO
Fig. 1-2
2-5: FOCUS
1.
Receive a 70dB monoscope pattern.
2.
Turn the Focus Volume fully counterclockwise once.
3.
Adjust the Focus Volume until picture is distinct.
2-6: HORIZONTAL POSITION
1.
Receive the center cross signal from the Pattern
Generator.
2.
Using the remote control, set the brightness and
contrast to normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (04) on the remote control to
select "H. POSI".
4.
Press the VOL. UP/DOWN button on the remote
control until the right and left screen size of the vertical
line becomes the same.
ELECTRICAL ADJUSTMENTS
2-7: VERTICAL LINEARITY
NOTE: Adjust after performing adjustments in section 2-6.
1.
Receive the center cross signal from the Pattern
Generator.
2.
Using the remote control, set the brightness and
contrast to normal position.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (09) on the remote control to
select "V. LIN".
4.
Press the VOL. UP/DOWN button on the remote
control until the upside and downside screen size of the
horizontal line becomes the same.
2-8: VERTICAL POSITION
NOTE: Adjust after performing adjustments in section 2-7.
1.2.Receive the center cross signal from the Pattern
Generator.
Adjust the VR401 until the horizontal line becomes fit to
the notch of the shadow mask.
2-9: VERTICAL SIZE
NOTE: Adjust after performing adjustments in section 2-8.
1.
Receive the crosshatch signal from the Pattern
Generator.
2.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (07) on the remote control to
select "V. SIZE".
3.
Press the VOL. UP/DOWN button on the remote
control until the rectangle on the center of the screen
becomes square.
4.
Receive a broadcast and check if the picture is normal.
2-10: OSD HORIZONTAL
1.2.Activate the adjustment mode display of Fig. 1-1.
Press the VOL. UP/DOWN button on the remote control
until the difference of A and B becomes minimum.
(Refer to Fig. 2-1)
TV
00 OSD 15
A
B
Fig. 2-1
2-12: SEPARATION 1, 2
Receive the stereo signal (L=2KHz, R=400Hz).
1.
Connect the AC voltmeter to AUDIO OUT JACK though
2.
stereo filter (L=400Hz, R=2KHz).
Activate the adjustment mode display of Fig. 1-1 and
3.
press the channel button (31) on the remote control to
select "SEP1".
Press the VOL. UP/DOWN button on the remote control
4.
until the output of L-CH and R-CH become minimum.
Press the CH UP button once the set to "SEP2" mode.
5.
Press the VOL. UP/DOWN button on the remote control
6.
until the output of L-CH and R-CH become minimum.
Press the CH DOWN button once the set to "SEP1"
7.
mode.
Repeat step 4 to step 7 several times.
8.
The output difference of the between with Filter and
without Filter should be more than 25dB for both L and
R.
2-13: BRIGHTNESS
1.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (16) on the remote control to
select "BRI".
2.
Press the VOL. UP/DOWN button on the remote control
until the brightness step No. becomes "92"
3.
Press the TV/VIDEO button on the remote control to set
to the AV mode. Then perform the above adjustments
1~2.
4.
Press the TV/VIDEO button on the remote control to set
to the CS mode.
5.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (16) on the remote control to
select "BRI".
6.
Press the VOL. UP/DOWN button on the remote control
until the brightness step No. becomes "90"
2-14: UNI-COLOR
1.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (18) on the remote control to
select "UNI COL".
2.
Press the VOL. UP/DOWN button on the remote control
until the contrast step No. becomes "53"
3.
Press the TV/VIDEO button on the remote control to set
to the AV mode. Then perform the above adjustments
1~2.
4.
Press the TV/VIDEO button on the remote control to set
to the CS mode.
5.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (18) on the remote control to
select "UNI COL".
6.
Press the VOL. UP/DOWN button on the remote control
until the contrast step No. becomes "54"
2-11: LEVEL
1.
Receive the VHF HIGH (70dB).
2.
Connect the AC voltmeter to TP901.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (30) on the remote control to
select "LEVEL".
4.
Press the VOL. UP/DOWN button on the remote
control until the AC voltmeter is 75 ± 2mV.