Manufactured under license from Dolby Laboratories Licensing
Corporation.
“DOLBY” the double-D symbol a “AC-3” and “PRO LOGIC”
are trademarks of Dolby Laboratories Licensing Corporation.
SPECIFICATIONS
AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC DISTORTION:
With 8 ohm loads, both channels driven, from 20 - 20,000 Hz; rated
100 watts per channel minimum RMS power, with no more than
0.09% total harmonic distortion from 250 milliwatts to rated output .
Amplifier section
POWER OUTPUT
Stereo mode
Surround mode
a)Depending on the sound field settings and the source, there may be no
sound output.
Dynamic power output
Harmonic distortion at rated output
Frequency response
(8 ohms 20 Hz –20 kHz, THD 0.09%)
100 W + 100 W
(8 ohms at 1 kHz, THD 0.8%)
Front: 100 W/ch
Centera): 100 W
Reara): 100 W/ch
155 W + 155 W, 8 ohms
220 W + 220 W, 4 ohms
Less than 0.09% (with sound field, tone, and bass
booster bypassed)
PHONO: RIAA
equalization curve
±0.5 dB
CD, T APE, MD/DAT, TAPE/MD, DVD/LD, TV/DBS,
VIDEO 1 and VIDEO 2 :
S/N: 100 dB (A, 20 kHz LPF)
TAPE/MD, (REC OUT); VIDEO 1, 2
(AUDIO OUT):
Voltage: 150 mV
Impedance: 10 kilohms
WOOFER:
Voltage: 2 V
Impedance: 1 kilohms
PHONES:
Accepts low - and high-impedance headphones
+6 dB at 70 Hz
— Continued on next page —
MICROFILM
FM STEREO FM-AM RECORDER
Sampling Frequency
EQ
48 kHz
BASS:
MID:
TREBLE:
Gain levels:
100 Hz ~ 1.0 kHz (21 steps)
500 Hz ~ 5.0 kHz (21 steps)
1.0 kHz ~ 10 kHz (21 steps)
±10 dB, 1 dB step
Harmonic distortion
Selectivity
d)You can change the AM tuning scale to 9 kHz. After tuning in any AM
station, turn off the receiver. Hold down the TUNING + button and
press the 1/u button. All preset stations will be erased when you
change the tuning scale. To reset the scale to 10 kHz, repeat the
procedure.
0.5% (50 mV/m, 400 kHz)
At 9 kHz: 35 dB
At 10 kHz: 40 dB
50 dB/m (at 1,000 kHz or 999 kHz)
54 dB (at 50 mV/m)
Video section
Input
Outputs
General
System
1 Vp-p 75 ohms
1 Vp-p 75 ohms
Tuner section:
PLL quartz-locked digital synthesizer system
Preamplifier section:
Low- noise NF type equalizer
Power amplifier section:
Pure-complementary SEPP
Power requirements
Power consumption
120 V AC, 60 Hz
AC outlets
Dimensions
d)
d)
Mass (Approx.)
Supplied accessories
Design and specifications are subject to change without notice.
290 W
2 switched, total 100 W
430 × 355 × 157.5 mm
(17 × 14 × 61/4 in.)
including projecting parts and controls
10.5 kg (23 lb 3 oz)
• FM wire antenna (1)
• AM loop antenna (1)
• Remote commander RM-PP401 (remote) (1)
• Carbon-ZINC dry batteries (2)
— 2 —
SAFETY CHECK-OUT
TABLE OF CONTENTS
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.A commercial leakage tester , such as the Simpson 229 or RCA
WT -540A. Follow the manufacturers’ instructions to use these
instruments.
2.A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter . The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
— DIGITAL (SIDE A) Section —··································· 41
3-19. Printed Wiring Board
— DIGITAL (SIDE B) Section — ··································· 43
3-20. Schematic Diagram — DIGITAL Section (1/3) —·········· 45
3-21. Schematic Diagram — DIGITAL Section (2/3) —·········· 47
3-22. Schematic Diagram — DIGITAL Section (3/3) —·········· 49
3-23. IC Pin Function Description ············································ 51
3-24. IC Block Diagrams ··························································· 61
AC
0.15
µ
F1.5k
Ω
voltmeter
(0.75V)
Earth Ground
Fig. A. Using an AC v oltmeter to check A C leakage.
SAFETY-RELATED COMPONENT WARNING!!
4.EXPLODED VIEWS
4-1. Front Panel Section ·························································· 64
4-2. Chassis Section································································· 65
5.ELECTRICAL PARTS LIST ··································· 66
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH
MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY .
— 3 —
LOCATION AND FUNCTION OF CONTROLS
[FRONT PANEL]
SECTION 1
GENERAL
#§
#∞
#¢
#£
#™
#¡
1
#º
@ª
2
@•
@§¿
@¶
3
4
@¢@∞
11/u (POWER) button
2MULTI CURSOR CONTROL
3SURROUND, EQUALIZER, INDEX indicators
4DIRECT TUNING button
5VIDEO 1 button
6MULTI CHANNEL DECODING indicator
7TV/DBS button
8SOUND FIELD GENRE button
9SOUND FIELD MODE button
0SOUND FIELD, EQ, BASS BOOST indicators
!¡MASTER VOLUME control
!™BALANCE control
!£MUTING button
!¢SOUND FIELD ON/OFF button
!∞BASS BOOST button
!§EQ ON/OFF button
!¶INPUT MODE button
!•PHONO button
!ªDVD/LD
!™WIRELESS REAR SPEAKER
!£IMPEDANCE SELECTOR
!¢AC power cord
!∞AC OUTLET
!§FRONT SPEAKERS (A/B)
!¶SPEAKERS (FRONT)
!•CD
!ªPHONO
@ºy SIGNAL GND
!¢
!∞
— 5 —
SECTION 2
TEST MODE
FLUORESCENT INDICATOR TUBE TEST MODE
* All fluorescent segments are tested. When this test is activated,
all segments turn on at the same time, then each segment turns on
one after another.
* Procedure:
While depressing the SET UP and the SOUND FIELD MODE
buttons simultaneously, press the power 1/u button to turn on
the main power. All segments turn on at the same time, then each
segment turns on one after another.
FACTORY SET MODE
* All preset contents are reset to the default setting.
* Procedure:
While depressing the SET UP and the SOUND FIELD ON/OFF
buttons simultaneously, press the power 1/u button to turn on
the main power. The message FACTORY SET appears and the
present contents are reset to the default values.
ALL CLEAR MODE
* All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
* Procedure:
While depressing the DISPLAY and the SOUND FIELD ON/
OFF buttons simultaneously, press the power 1/u button to
turn on the main power. The machine enters the DEMO
mode.DEMO mode: Wait a while, then the demonstration starts.
If the power 1/u button is pressed often the demonstration has
started, the power is turned off, and the demonstration resumes if
the power 1/u button is pressed again.
ALL CLEAR mode; If the power 1/u button is pressed often
the machine enters the DEMO mode, but before the demonstration
starts, the display is turned off. Press 1/u again. No response is
returned. Then press 1/u again. The preset data is cleared and
the machine enters the normal power-on state.
SOUND FIELD CLEAR MODE
* The preset sound field is cleared when this mode is activated.
Use this mode before returning the product to clients upon
completion of repair.
* Procedure:
While depressing the SOUND FIELD ON/OFF button, press
the power 1/u button to turn on the main power. The message
SURR CLEAR! appears and initialization is performed.
AM CHANNEL STEP 9 kHz/10 kHz
SELECTION MODE
* Either the 9 kHz step or 10 kHz step can be selected for the AM
channel step.
* Procedure:
Set the FUNCTION to AM. Turn off the main power.
While depressing the TUNING+ button or the PRESET TUNING
+ button, press the power 1/u button to turn on the main power.
Either the message AM 9kHz STEP or AM 10kHz STEP appears.
Select the desired step.
DSP TEST MODE
* Procedure:
While depressing the SET UP and the SOUND FIELD GENRE
buttons simultaneously, press the power 1/u button to turn on
the main power. The message DSP NO ERROR or DSP ERROR.
— 6 —
SECTION 3
d
DIAGRAMS
STR-DE725
3-1. CIRCUIT BOARDS LOCATION
DISPLAY board
SP SW board
H.P board
LED board
SW board
AC board
L.B board
REG board
SP board
VOLUME board
BALANCE board
AMPLIFIER board
REAR AMP board
INPUT board
JOINT board
VIDEO board
TUNER board
D.IN/OUT boar
DIGITAL board
AUDIO board
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this necessary note is printed in each
block.)
For schematic diagrams.
Note:
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in Ω and 1/
specified.
•%: indicates tolerance.
• 2 : nonflammable resistor.
• 1 : fusible resistor.
• C : panel designation.
The components identified by mark ! or dotted
line with mark ! are critical for safety.
Replace only with part number specified.
• U : B+ Line.
• V : B– Line.
• H : adjustment for repair.
• Voltages and waveforms are dc with respect to ground
under no-signal (detuned) conditions.
No mark : FM
• Voltages are taken with a V OM (Input impedance 10 MΩ).
Voltage v ariations may be noted due to normal production