Smeg WD1160,WD4190,WD4060,GW0160,GW4060,GW1160,GW4190 Technical Instructions

0160, 1160, 4060, 4190
Power Connection Conversion instruction
WD1160, WD4060, WD4190
GW0160, GW1160, GW4060, GW4190
- POWER CONNECTION CONVERSION INSTRUCTIONS -
- Technical Procedure -
0160, 1160, 4060
4190
19 561 0144 00 - EN
26/05/2017
Rev.
Date
WARNING This document is intended for authorised Smeg technical staff and must be used in combination with the technical
documentation; it describes the power connection conversion procedure.
Only “standard” 400V three-phase units with neutral (400V 3N~ 7.0kW) can be converted on site to the corresponding 230V single-phase version (230V~ 2.8kW).
The technical data plates of these devices state the two possible electrical connections and the standard configuration (400V 3N~) is marked with an asterisk.
After the power conversion, tests must be performed to check the appliance's electrical safety and the operation of its inputs and outputs; the complete “in -service test record” checklist must also compiled (in accordance with the SR quality procedure).
The illustrations and photographs below are guideline. Always refer to the latest electrical wiring diagram, available at www.smegtech.com.
0160, 1160, 4060, 4190
Power Connection Conversion instruction
1 POWER CONFIGURATION
MODELS
VARIANTS
POWER CONNECTION DESCRIPTION
ELECTRICITY SUPPLY
PROTECTIVE DEVICES
INCORPORATED IN THE APPLIANCE
WD1160 WD4060 WD4190 GW0160 GW1160 GW4060 GW4190
Standard
(400V three-
phase variants
with neutral)
400V three-phase
configurable
400V 3N~ / 50Hz / 12A / 7000W *
230V ~ / 50Hz / 12A / 2800W
FUSES 10.3x38 16 A ON POWER
SUPPLY
[L1, L2, L3]
In the table: the characteristics of the power supply cable supplied with the configurable appliances, product technical data plate and data plate which confirms the electrical configuration actually set up during installation.
POWER SUPPLY CABLE TECHNICAL DATA
FROR 5 x 2.5 mm2 (5G2,5), 450/750 V, IMQ mark
FACSIMILE OF CONFIGURABLE PRODUCT TECHNICAL DATA PLATE
DATA PLATE FOR USE BY AUTHORISED ELECTRICIAN TO CONFIRM ACTUAL CONFIGURATION
0160, 1160, 4060, 4190
Power Connection Conversion instruction
2 ELECTRICAL WIRING DIAGRAM
Refer to the latest electrical wiring diagram at www.smegtech.com. The section of the diagram involved in this procedure is shown below.
2.1 POWER SUPPLY 0160, 1160, 4060
Default configuration
Configurable connection - single-phase
400V 3N~ / 50Hz / 12A / 7000W
230V ~ / 50Hz / 12A / 2800W