1. Remove the back cover and the fastening
plates of the steam outlets by unscrewing
the screws indicated.
Do not remove the ventilation
outlet “A” and the protective cover
of the electrical connections “B”.
EN
3. Disconnect the contacts “C”, remove the
tie-wrap from the hose “D” and remove
the solenoid valve.
2. Remove the lower support cover and the
solenoid valve by removing the screws
indicated.
4. Assemble the pump “E” provided, with
the mounting bracket “F”, making sure
that you close the tab “G” by pressing it
with your hands. Then remove the caps
on the ends of the solenoid valve (“H1”
and “H2”).
4730
EN
5. Insert the grommet seal into the plate
provided.
6. Screw the plate, with grommet seal
installed in the previous step, onto the
lower support cover.
7. Connect the hose of the appliance “K” to
the end “H2” of the pump and connect
the tube supplied with the kit “L” to the
end “H1” (see step 4). Then secure them
using the tie-wraps provided.
8. Connect the sockets “M” of the cable
provided, to the terminals of the pump.