SMA Windy Boy 3300, Windy Boy 3800 User Manual

WB33_38-BA-BEN120930 | TBEN-WB33-38 | Version 3.0
EN
Wind Power Inverter
WINDY BOY 3300 / 3800
User Manual
User Manual WB33_38-BA-BEN120930 3
Table of Contents
1 Information on this Manual. . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Validity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Target Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.3 Explanation of Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3.1 Symbols on the Inverter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.3.2 Symbols on the Type Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.1 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.2 Display Messages during Operation . . . . . . . . . . . . . . . . . . . . 12
4.3 Display Messages during a Disturbance . . . . . . . . . . . . . . . . . 14
4.4 DC Overvoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 LED Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6 Visual Inspection, Maintenance and Cleaning . . . . . . . . 17
7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.1 Status Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.2 Measurement Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table of Contents SMA Solar Technology AG
4 WB33_38-BA-BEN120930 User Manual
SMA Solar Technology AG Information on this Manual
User Manual WB33_38-BA-BEN120930 5
1 Information on this Manual
1.1 Validity
This manual applies to the following device types:
WB 3300
WB 3300-IT
WB 3300-11
WB 3800
WB 3800-IT
WB 3800-11
1.2 Target Audience
This manual is intended for the operator.
1.3 Additional Information
You will find additional information on the device-specific technical data in the installation manual provided.
You will find additional information on particular topics (e.g. description of the operating parameters) in the download area at www.SMA.de/en.
Information on this Manual SMA Solar Technology AG
6 WB33_38-BA-BEN120930 User Manual
1.4 Symbols Used
The following types of safety precautions and general information are used in this manual:
DANGER!
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING!
WARNING indicates a safety precaution which, if not avoided, could result in death or serious injury.
CAUTION!
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
CAUTION!
NOTICE indicates a situation which, if not avoided, could result in property damage.
Information
Information provides valuable hints on the optimum installation and operation of the product.
SMA Solar Technology AG Safety
User Manual WB33_38-BA-BEN120930 7
2 Safety
2.1 Intended Use
The Windy Boy is a wind energy inverter which converts the rectified current of a small wind turbine system into AC current and feeds this energy into the electricity grid, domestic grid or the Sunny Island system.
Principle of a small wind turbine system with a Windy Boy
Furthermore, the Windy Boy can be used as an inverter for power conversion units based on permanent magnet generators (hydro-electric systems, combined heat and power plants, diesel generators, etc.). The manufacturer of the small wind turbine system or generator must have approved his plant for operation with this Windy Boy. For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG. When designing the PV plant, ensure that the permitted operating range of all components is complied with at all times. Moreover, make sure that appropriate protective measures are in place to ensure that the maximum permissible input voltage is not exceeded. SMA Solar Technology AG offers you the requisite components, such as the Windy Boy Protection Box (overvoltage protection for wind power inverters, including the rectifier).
Safety SMA Solar Technology AG
8 WB33_38-BA-BEN120930 User Manual
2.2 Safety Precautions
DANGER!
Electric shock caused by high voltage in the inverter
Even when no external voltage is connected, there may still be high voltages present in the inverter. The following work may only be carried out by trained, electrically qualified personnel:
Electrical installation
Repairs
Modifications
CAUTION!
Risk of burns through contact with the enclosure during operation
Only touch the enclosure lid and the display during operation.
CAUTION!
Damage to the inverter through overvoltage, if the yellow LED flashes 4 times.
Inform your installer immediately if the yellow LED starts to flash and the following display message appears:
SMA Solar Technology AG Safety
User Manual WB33_38-BA-BEN120930 9
2.3 Explanation of Symbols
2.3.1 Symbols on the Inverter
* This function is valid as of firmware version 4.00. ** QR-Code is a registered trademark of DENSO WAVE INCORPORATED.
Symbol Explanation
Operation display
Earth fault or varistor defective Please inform your installer.
An error has occurred. Inform your installer immediately.
You can operate the display by tapping the enclosure lid.
Single tap: the backlight switches on or the display scrolls one message further.
Double tap in quick succession*: The inverter displays the device type, the firmware version and the configured country standard (see Section 4.2"Display Messages during Operation" (page12)).
QR-Code
®
** for SMA bonus programme
You will find information on the SMA bonus programme at www.SMA-Bonus.com.
Safety SMA Solar Technology AG
10 WB33_38-BA-BEN120930 User Manual
2.3.2 Symbols on the Type Label
Symbol Explanation
Beware of dangerous electrical voltage.
The inverter operates at high voltages. All work on the inverter may only be carried out by a trained, electrically qualified person.
Beware of hot surface.
The inverter can become hot during operation. Avoid contact during operation.
Observe all documentation that accompanies the inverter.
The inverter must not be disposed of together with the household waste. Further disposal information can be found in the enclosed installation manual.
CE marking
The inverter complies with the requirements of the applicable EC directives.
The inverter has a transformer.
Direct current (DC)
Alternating current (AC)
Degree of protection IP65
The inverter is protected against dust intrusion and water jets from any angle.
The inverter is suitable for outdoor installation.
RAL quality mark for solar products
The inverter complies with the requirements of the German Institute for Quality Assurance and Labelling.
SMA Solar Technology AG Product Overview
User Manual WB33_38-BA-BEN120930 11
3 Product Overview
Position Designation
AEnclosure lid BDisplay CLEDs
Green LED = Operation
Red LED = Earth fault or varistor defective
Yellow LED = Fault D Ventilation grid E Type label for the identification of the inverter via the serial number (Serial No.).
XXXXXXXXX
*
XX
X*
S
U
N
N
Y
B
O
Y
I
A
C
n
o
m
I
ACnom
c
o
s
ϕ
xxxxxx
A
B
C
D
E
Display SMA Solar Technology AG
12 WB33_38-BA-BEN120930 User Manual
4 Display
4.1 Operation
The display shows the current values of your plant. The displayed values are updated every 5 seconds.
You can operate the display by tapping the enclosure lid.
Single tap:
The backlight is switched on. After two minutes, the backlight switches off automatically.
Double tap in quick succession (valid from firmware version 4.00):
The inverter successively displays the device type, the firmware version and the configured country standard.
4.2 Display Messages during Operation
After commissioning, the inverter successively displays the device type, the firmware version and the configured country standard. If you want to view the display messages of the startup phase again while in normal operation, tap on the enclosure lid twice in quick succession (from firmware version 4.00).
Display message Description
Inverter device type
Firmware version of internal processors
Default country standard in the inverter, example: "VDE-AR-N4105"
SB xxx
WRxxx
Sunny Boy xxx
WRxx
SMA Solar Technology AG Display
User Manual WB33_38-BA-BEN120930 13
Upon error-free connection of the inverter to the electricity grid, after approximately one minute, the display starts alternating between the messages shown below. Each message appears for five seconds, and then the cycle restarts from the beginning.
* Applicable for WB 3300 / WB 3300-IT / WB 3800 / WB 3800-IT ** Applicable for WB 3300-11 / WB 3800-11
Display message Description
Energy generated on the current day
Status message "Turbine"*
Status message "Turbine"**
Current feed-in capacity
AC line voltage of the inverter:
After a further five seconds or after tapping, the current values of the reactive power Qac and of the displacement power factor cos φ (PF) are displayed.**
Total amount of energy fed in
Total number of operating hours in feed-in operation
Display SMA Solar Technology AG
14 WB33_38-BA-BEN120930 User Manual
4.3 Display Messages during a Disturbance
In the event of a disturbance, the inverter displays the status "Disturbance" and an error message. Please inform your installer. The following messages will be generated:
4.4 DC Overvoltage
Display message Description
Energy generated on the current day
Status message "Disturbance"
Operating state
Error message
Measured value at the time of the disturbance
Current measured value (only displayed if a measured value is responsible for the disturbance)
Display message Description
The DC input voltage connected to the inverter is too high.
Please inform your installer immediately.
SMA Solar Technology AG LED Signals
User Manual WB33_38-BA-BEN120930 15
5 LED Signals
Status Description
All LEDs are on The inverter is initializing.
All LEDs are off The DC input voltage at the inverter is too low for feed-in.
All LEDs are flashing
The inverter is in the startup phase.
Green LED is on
The inverter is feeding into the electricity grid.
Green LED is flashing
This flashing can be caused by:
The inverter is monitoring the electricity grid and is waiting for the DC voltage to reach a defined limit so that it can begin feeding the into the network.
Operation interrupted.
Power limitation in the inverter.
LED Signals SMA Solar Technology AG
16 WB33_38-BA-BEN120930 User Manual
Red LED is on An earth fault has occurred or one of the thermally
monitored varistors on the DC input side is defective. Please inform your installer.
Yellow LED is on
The inverter is in the operating state "Operation permanently disabled". This can have several causes. Please inform your installer.
Yellow LED is flashing
This indicates a disturbance. This can have several causes. Please inform your installer.
Status Description
SMA Solar Technology AG Visual Inspection, Maintenance and Cleaning
User Manual WB33_38-BA-BEN120930 17
6 Visual Inspection, Maintenance and Cleaning
Visual inspection
Check the inverter and cables for any signs of external damage. Contact your installer if you find any damage. Do not perform any repair work yourself.
Maintenance and cleaning
CAUTION!
Damage to the display by use of cleaning agents
If the inverter is dirty, clean the enclosure lid, the display and the LEDs with clear water and a cloth only.
Troubleshooting SMA Solar Technology AG
18 WB33_38-BA-BEN120930 User Manual
7 Troubleshooting
7.1 Status Messages
Your inverter can be in various operating states. These are displayed as status messages, which can vary according to the type of communication.
Message Description
Derating Overtemperature in the inverter. The inverter reduces its power to
prevent overheating. To avoid unnecessary yield losses, check the
plant configuration. Please inform your installer. Error An error has been detected. Please inform your installer. Grid monitoring Grid monitoring
This message appears during the startup phase before the inverter
is connected to the electricity grid, and following an error. Off Grid The inverter is in "Island" mode. This mode is specially designed for
operation in an off-grid system. Offset Offset adjustment of the measurement electronics. Stop Operation interrupted. Turbine The inverter is in the operating state "Turbine". This mode is
specially designed for operation in small wind turbine systems. V-Const Constant voltage mode. Waiting The conditions for connecting are not (yet) fulfilled. Warning/Disturbance Disturbance
This message appears for safety reasons and ensures that the
inverter does not connect to the electricity grid. Please inform your
installer.
SMA Solar Technology AG Troubleshooting
User Manual WB33_38-BA-BEN120930 19
7.2 Measurement Channels
If your inverter is equipped with a communication product, numerous measurement channels and messages can be transmitted for diagnostics.
Measurement channel Description
Error Identification of the present disturbance/error E-total Total amount of energy fed in Event-Cnt Number of events that have occurred Fac Power frequency h-On Total operating hours h-total Total number of operating hours in feed-in operation Iac Line current Ipv Direct current Pac Generated AC power Power On Total number of grid connections Riso Insulation resistance of the small wind turbine system Serial number Inverter serial number Status Display of the current operating state Vac Line voltage Vpv DC input voltage Vpv-Set DC target voltage
Glossary SMA Solar Technology AG
20 WB33_38-BA-BEN120930 User Manual
8 Glossary
AC
Abbreviation for "Alternating Current".
DC
Abbreviation for "Direct Current".
Derating
A controlled reduction in performance, usually dependent on component temperatures.
Varistor
The varistors protect the electronics in the inverter from atmospherically coupled energy peaks, such as those that can occur when lightning strikes nearby.
SMA Solar Technology AG Contact
User Manual WB33_38-BA-BEN120930 21
9 Contact
If you have technical problems, please contact your installer first. The following information is required in order to provide you with the necessary assistance:
•Inverter device type
Inverter serial number
Type of connected small wind turbine system
Blink code or display message of the inverter
Optional equipment (e.g. communication products)
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal, Germany
www.SMA.de
SMA Service Line
Inverters: +49 561 9522 1499 Communication: +49 561 9522 2499 Fax: +49 561 9522 4699 E‑Mail: ServiceLine@SMA.de
SMA Solar Technology AG Legal Restrictions
User Manual WB33_38-BA-BEN120930 23
The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.
SMA Factory Warranty
The current warranty conditions come enclosed with your device. These are also available online at www.SMA.de and can be downloaded or are available on paper from the usual sales channels if required.
Trademarks
All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark.
The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by
SMA Solar Technology AG is under licence.
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal
Germany
Tel. +49 561 9522-0
Fax +49 561 9522-100
www.SMA.de
E-Mail: info@SMA.de
© 2004 to 2012 SMA Solar Technology AG. All rights reserved
XXX4."4PMBSDPN
4."4PMBS5FDIOPMPHZ
4."4PMBS5FDIOPMPHZ"(
XXX4."EF
4.""NFSJDB--$
XXX4.""NFSJDBDPN
4."5FDIOPMPHZ"VTUSBMJB1UZ-UE
XXX4.""VTUSBMJBDPNBV
4."#FOFMVY413-
XXX4."#FOFMVYDPN
4."#FJKJOH$PNNFSDJBM$P-UE
XXX4."$IJOBDPN
4."$[FDI3FQVCMJDTSP
XXX4."$[FDIDPN
4."'SBODF4"4
XXX4."'SBODFDPN
4.")FMMBT"&
XXX4.")FMMBTDPN
4."*C©SJDB5FDOPMPHB4PMBS4-
XXX4."*CFSJDBDPN
4."*UBMJB4SM
XXX4."*UBMJBDPN
4."5FDIOPMPHZ,PSFB$P-UE
XXX4.",PSFBDPN
Loading...