Repair Parts and Maintenance Guide
3
4A
6
9
11
8
3
19
EBF-650EBF-615
2
1
20
2
1
Repair Parts and Maintenance Guide
Optima® EBF-550
PARTS LIST—EBF-550 FAUCET
Item
No. Code No. Part No. Description
1A. 0315224PK EBF-222-A-ST Faucet and Sensor Assembly with Standard
1B. 0315227PK EBF-222-A-SU Faucet and Sensor Assembly with Surgical Bend
2. 0305784 ETF-178 Adapter for Spray Heads (not required for
3A. 0365147 ETF-621 2.2 gpm (8.3 Lpm) Laminar Flow Spray Head with
0365793 ETF-839 0.35 gpm (1.3 Lpm) Multi-Lam Spray Head
0305927 ETF-435 Replacement Key ONLY
3B. 0328134 AC-55-A Shower Spray Head Assembly, 2.2 gpm (8.3 Lpm)
5A
5
4. 0315060 EBF-110-A Faucet Mounting Kit includes Base Gasket,
0365152 ETF-591 1/8” NPT Pipe to 3/8” Tube Male Compression
6
5. 0365758 ETF-740-A 6 VDC Solenoid Valve Assembly
5A. 0365774 ETF-742-A 6 VDC Solenoid Valve Only
6. 0365752 ETF-735-A Control Module
7. 3365461 ETF-617-A Bak-Chek® “T” Assembly
— 0365838 ETF-1003 36” Extension Cable (Optional)
— Not shown in illustration
For additional information about Sloan Mixing
Valves or Trim Plates, consult our Installation
Instructions and Maintenance Guides.
OLDER MOUNTING KIT
7
OLD MOUNTING KIT AND FAUCET SHANK
8. N/A†† EBF-110-A Old Faucet Mounting Kit included 3/8” Water
New Base Gasket
The new base gasket
(in production since
October 1999) is shown
below. An older base
gasket design did not
have the u-shaped
drainage hole.
8
9. 0365058†† ETF-547 1/8” NPT Pipe to 3/8” Tube Female Compression
9
Note: earlier faucet models are not
compatible with the current models.
PARTS PRIOR TO SEPTEMBER 2009
11. 0315104 EBF-60-A Control Module Assembly
12. 0315254 EBF-1011-A Solenoid Replacement Kit
13. 3315029 EBF-113-A Single Solenoid Supply Compression Nut Kit
14. 3315018 EBF-79-A Mounting Hardware Kit
15. 3315222PK EBF-222A-ST Standard Gooseneck Spout & Old Style Sensor
OBSOLETE Assembly (Flat 7 wire Black Modular Plug)
16. 0315153 EBF-206-A Sensor Window w/ Cable Assembly
Gooseneck Spout (EBF-550) w/ ETF-178 (new
sensor w/ phone jack
Gooseneck Spout (EBF-550-S) w/ ETF-178 (new
sensor w/ phone jack
AC-55-A Shower Spray Head)
Key (female thread)
large Flat Washer, large Lockwasher, large
Nut, Mounting Spacer, Mounting Stud, small
Flat Washer, small Lockwasher, small Nut,
Anti-Rotation Screw, and Compression Fitting
Connector (male)
Fitting Connector
Supply Tube, Base Gasket, large Flat Washer,
large Lock Washer, large Nut, and Compression
Fitting Connector (order Items 4 and 10 as
replacement parts)
Fitting Connector
Faucets and
Soap Dispensers
13
12
13
11
14
185
The information contained in this document is subject to change without notice.

Repair Parts and Maintenance Guide
Repair Parts and Maintenance Guide
187
The information contained in this document is subject to change without notice.
Repair Parts and Maintenance Guide
Optima® EBF-615/EBF-650
EBF-615 EBF-650
3
4A
4B
7
6
9
10A
10B
10E
11
13
12
8
3
EBF-650EBF-615
2
1
2
1
10C
10D
PARTS LIST—EBF-615 AND EBF-650 FAUCETS
Item
No. Code No. Part No. Description
1. 0365400 ETF-749-A Sensor Only
2. 3365092 ETF-1023-A 0.5 gpm (1.9 Lpm) Spray Head with
Key (male thread)
3365093 ETF-1024-A 2.2 gpm (8.3 Lpm) Aerator Spray Head
with Key (male thread)
3365162 ETF-1029-A 2.2 gpm (8.3 Lpm) Laminar Flow (male thread)
3365756 ETF-1039-A 0.35 gpm (1.3 Lpm) Multi-Lam Spray Head VR
3. 0305927 ETF-435 Replacement Key Only for ETF-1023-A
0.5 gpm (1.9 Lpm) Spray Head and ETF-1024-A
2.2 gpm (8.3 Lpm) Aerator Spray Head
4A. 3365088 ETF-546-A Faucet Mounting Kit for EBF-650 includes Base
Gasket, two (2) Slotted Mounting Washers, two (2)
Wing Nuts and ETF-547 Compression Fitting
Connector
4B. 0315085 EBF-123-A Faucet Mounting Kit for EBF-615 includes Base
Gasket, Spacer, Washer, 9/16” Lockwasher,
1/4” NPSM Hex Nut and ETF-547 Compression
Fitting Connector
5. 0365058 ETF-547 1/8” NPT Pipe to 3/8” Tube Compression
Fitting Connector (female)
6. 3365461 ETF-617-A 3/8” Bak-Chek® Tee Compression Fitting
7. 0365758 ETF-740-A 6 VDC Solenoid Valve Assembly
7A. 0365774 ETF-742-A Solenoid with armored cable and wire only
(no valve assembly
8. 0365752 ETF-735-A Control Module
9. 0362006 SFP-6 110 VAC/6 VDC Plug-In Adapter
—. 0365838 ETF-1003 36” Extension Cable (Optional)
OPTIONAL TRIM PLATES
10A. 3365302 ETF-607-A 4” (102 mm) Centerset Trim plate for EBF-625
10B. 3365303 ETF-608-A 8” (204 mm) Centerset Trim Plate for EBF-625
10C. 3326012 MIX-101-A 4” (102 mm) Centerset Trim plate for EBF-625
with optional mixing Valve
10D. 3326017 MIX-106-A 8” (204 mm) Centerset Trim plate for EBF-625
10E. 3365119 ETF-578-A 8” (204 mm) Centerset Trim plate for EBF-655
OPTIONAL MIXING VALVES
11. 3326009 MIX-60-A Below Deck Mechanical Water Mixing
Valve (BDM Variation)
12. 0326045 MIX-135-A Below Deck Thermostatic Water Mixing
Valve (BDT Variation)
13. 3326018 MIX-110-AA Optimix® Deck Mounted Water Mixing
Valve (only available for EBF-615 faucets)
— Not shown in illustration
For parts prior to September 2008 (Old Style) refer to page 182 (EBF-625 & EBF-655).
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
Optima® EBF-550
Faucets and
Soap Dispensers
TROUBLESHOOTING GUIDE
1. Sensor LED does not function (sensor indicator light DOES NOT
fl ash during initial 10 minute set-up mode).
A. There is no visible indicator light. Normal operation. This is a normal
operating feature of the faucet.
OLD STYLE SENSOR INDICATOR LIGHTS
NEW STYLE SENSOR INDICATOR LIGHT
2. Faucet DOES NOT deliver any water when Sensor is activated.
INDICATOR: Solenoid valve produces audible “CLICK.”
A. Water supply stop(s) closed. Open supply stop(s) completely.
INDICATOR: Solenoid valve DOES NOT produce an audible
“CLICK.”
B. Solenoid lead is not properly connected to the control module.
Disconnect and reconnect solenoid lead to the control module.
C. No battery or transformer (optional) power is being supplied to
sensor. Ensure that the batteries are installed properly. Check that
the orientation of each battery matches the positive (+) and negative
(—) symbols shown on the bottom of the battery compartment.
Reinsert the batteries into the control module. Transformer (optional) is
unplugged or wall receptacle has no power.
SCREWS (2)
FOUR (4)
NEW AA-SIZE
ALKALINE
BATTERIES
LOCKING
TABS
OPTIONAL
PLUG-IN
TRANSFORMER
D. Sensor cable is not properly connected to the control module.
Disconnect and reconnect sensor cable to the control module.
E. Sensor range is set at minimum distance. Increase sensor range. Refer
to range adjustment in your installation instructions.
F. Control module assembly is not working properly. Replace control
module assembly.
3. Faucet delivers only a slow fl ow or dribble when sensor is
activated.
A. Water supply stop(s) partially closed. Open supply stop(s) completely.
B. Solenoid lter is clogged. Remove, clean and reinstall lter. Turn
off water supply at supply stop(s). Activate faucet to relieve system
pressure. Remove water supply line from inlet side of solenoid valve.
Remove cap, water line tting, gasket, lter housing and lter from
solenoid valve housing. Slide lter off lter housing. Clean lter
using fresh tap water only. If necessary, use a small brush to clean.
Use caution while cleaning to prevent damage to lter. If any lter
components are damaged, replace as necessary. Examine the gasket
for wear or damage; replace if necessary. Reinstall lter on lter
housing. Install lter housing, gasket, water line tting and cap onto
solenoid valve housing. Tighten cap securely. Reinstall water supply
line to inlet side of solenoid valve.
C. Aerator is clogged. Remove, clean and reinstall aerator.
4. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected (automatic shut-off fails even when
batteries are removed).
A. Solenoid valve has been connected backwards. Disconnect solenoid
valve compression ttings at both the inlet and outlet positions. The
water should ow from inlet through the solenoid valve to the outlet
according to the direction of the arrow shown on the side of the
solenoid valve. Reconnect the compression ttings in the correct
orientation.
B. Solenoid valve is dirty. Back ush by reversing water ow (opposite to
the direction shown by the arrow on the side of the solenoid valve)
through the solenoid valve. Reconnect the compression ttings in the
correct orientation. Activate faucet.
C. Solenoid valve module is not working properly. Replace solenoid
valve module.
5. The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines with Bak-Chek
A. Supply stops are not adjusted properly. Adjust supply stops.
NOTE: For some systems, a thermostatic mixing valve may be
required.
6. The RED LED turns on in the control module (below deck).
A. One (or more) of the batteries is “dead”. To ensure proper operation,
insert four (4) new AA-size Alkaline batteries. Check that the
orientation of each battery matches the positive (+) and negative (–)
symbols shown on the bottom of the battery compartment. Reinsert
batteries into the control module.
B: Upon start-up mode the control module circuitry also tests the
batteries and the RED LED turns on if the battery voltage is low, no
RED LED light indicates normal battery voltage.
C. If reset (initiates start up mode) button is
pressed, the battery voltage is checked.
If voltage is too low, product is stopped
from operating and RED LED will turn on.
No RED LED light indicates normal battery
INLET SIDE OF SOLENOID VALVE HOUSING
FILTER
FILTER HOUSING
WATER LINE FITTING
GASKET
CAP
®
Tee.
RESET
BUTTON
voltage.
7. The GREEN LED initially turns on in the
control module (below deck) during
start up mode, then will not appear
again.
INDICATOR: For the 1st ten minutes of operation (batteries
inserted or reset button pressed) the GREEN LED will turn on
when there is a target present (hands in front of sensor). After
ten minutes, the GREEN LED will no longer turn on.
A. This is a normal operating feature of the faucet.
The information contained in this document is subject to change without notice.
186