Sloan OPTIMA AIR EHD-700 Series Installation And Owner's Manual

Code No. 0816863
Rev.1 (11/18)
OPTIMA AIR™ HAND DRYER
EHD-700 SERIES
INSTALLATION AND OWNERS MANUAL
CONTENTS OF BOX
Hand Dryer Installation and Owners Manual
Tamper-Proof 5/32” Hex security bit wrench Knockout Gasket (Included for use with White Model only)
MODEL INFORMATION
Dryer Model
Serial Number
Date Of Purchase
LIMITED WARRANTY
Sloan Valve Company warrants its Optima Air™ Hand Dryer to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which it is intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of five years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
WARNING: For proper electrical connections, check your local building codes. Your unit must be installed by a qualied, licensed electrician.
IMPORTANT SAFETY INSTRUCTIONS
1
READ AND SAVE THESE INSTRUCTIONS
PRE INSTALLATION WIRING
INSTALLATION INSTRUCTIONS
Check that the electrical supply corresponds to that shown­on the rating sticker of unit. If the dryer is connected to any electrical supply other than that stated on the rating sticker ofthe unit, permanent damage or improper, unsafe operation ofthe unit may result.
•Make sure electricity is switched off at the main panel before installing, maintaining or cleaning this hand dryer. Dryer must be installed in accordance with current local wiring andbuilding regulations.
Do not wire this hand dryer into the lighting circuit. It must be protected by an independent circuit.
INSTALLATION INSTRUCTIONS
1.Disconnect the power source previously brought to the
hand dryer location (see pre installation wiring above).
2.Use the Tamper-Proof Wrench supplied and remove the Tamper-Proof Bolt on bottom of cover lifting upwards to remove cover from base plate.
3.If electrical wiring entry is to be made from the rear, remove the appropriate pre-formed knockout on the base plate. FOR WHITE Only - If entry is to be made from the side, knock out the pre- formed area on the right side of cover for your supply connection using knockout gasket provided. A rigid conduit must be used.
4.Select the appropriate mounting height for dryer (Table 1) and fastener, as recommended (Table 2). There should be no obstruction between the hand dryer and the oor. If mounting over a countertop, distance from counter to dryer must be 15” (381 mm) minimum.
CAUTION: Do not use Base Plate as a guide when drilling. Make sure no pipe work (gas, water, air) or any electrical cables or wires are located directly behind the area to be drilled.
5.Attach Base Plate at the four corners to smooth wall. Use
one of 2 knockouts provided for service entry on back of Base Plate. If using surface wiring use knockout in right side of cover. Use Knockout Gasket supplied around conduit for water seal. See Mounting Details.
TABLE 1 TABLE 2
1
SUGGESTED MOUNTING HEIGHT
from oor to bottom of dryer: Men 45” (114 cm) Women 43” (109 cm) Teenagers 41” (104 cm) Small Children 35” (89 cm) Handicapped 37” (94 cm)
•Dryer is intended to be permanently connected to power­supply, and must be properly grounded.
SAFETY
•Troubleshooting and internal maintenance must be performed by qualied service personnel.
Do not use any power wash equipment for cleaning on or near this unit.
Do not use the dryer for drying hair.
Do not obstruct air inlets or outlets.
6.Identify the voltage of your dryer from the rating sticker of the unit. Then connect to a dedicated branch circuit not exceeding 20 Amp. per your local wiring and building regulations.
7.Secure electrical wiring to terminals as indicated by the schematic afxed to blower housing. An identied ground connection point is supplied on the Base Plate for your equipment ground wire. Dryers should be installed per local code requirements.
8.In multiple installations, make sure the serial number marked on the inside matches the cover number. Then carefully replace Cover by inserting top of cover over bracket and tilting downward. Use Tamper-Proof Bolt previously removed in step 2.
9.Restore power and test for proper operation.
10. Return Tamper-Proof Wrench to owner.
2
MOUNTING HARDWARE Recommended Fastener (not supplied):
Masonry Wall ½” Expansion Sleeve with ¼” Lag Bolt Hollow Wall ¼” Wing Type Toggle Bolt Wooden Wall ¼” Lag Screw With Washer
2