HYB-7000 HYBRID URINAL
with Jetrinse Solution Technology
NEW CONSTRUCTION
INSTALLATION INSTRUCTIONS
BEFORE STARTING INSTALLATION:
due to copper’s susceptibility to corrosion.
Check rough-in height to achieve 24” rim height
(17” rim height for ADA).
Check slope. Downhill slope, per code, is essential because waterfree urinals depend on gravity flow. Check DWV material. Suitable materials include
cast iron, PVC, ABS and galvanized steel.
TUBE CUTTING CHART
Measure drain nipple depth (inches) to find trim length (inches)
13 7/8” or more DO NOT CUT
3 3/4” or less DO NOT USE TUBE
OR LESS TRIM
13 ¾" ¼" 13 ½ ½ 13 ¼ ¾ 13 1 12 ¾ 12 ½ 12 ¼ 12 2 11 ¾ 11 ½ 11 ¼ 11 3 10 ¾ 3 ¼ 10 ½ 3 ½
CUSTOMER CARE
1-800-982-5839 customer.service@sloanvalve.com
OR LESS TRIM
10 ¼" 3 ¾" 10 4 9 ¾ 4 ¼ 9 ½ 4 ½ 9 ¼ 4 ¾ 9 5 8 ¾ 5 ¼ 8 ½ 5 ½ 8 ¼ 5 ¾ 8 6 7 ¾ 6 ¼ 7 ½ 6 ½ 7 ¼ 6 ¾ 7 7
OR LESS TRIM
6 ¾" 7 ¼" 6 ½ 7 ½ 6 ¼ 7 ¾ 6 8 5 ¾ 8 ¼ 5 ½ 8 ½ 5 ¼ 8 ¾ 5 9 4 ¾ 9 ¼ 4 ½ 9 ½ 4 ¼ 9 ¾ 4 10
1
½" to ¾"
for ADA
10"
installation
*
standard 24" rim
17”
finished floor
Set drain line height 17” from finished floor (standard 24” rim) or 10” for ADA installation. Threaded nipple should extend 1/2 to 3/4” from wall. * IMPORTANT Nipple must not extend more than 3/4” past the finished wall
5
Measure and mark rough in. Use a 5/16”
masonry bit to drill hole, then install the hanger bracket with one plastic anchor and screw. Level the bracket then mark, drill and install two plastic anchors and screws.
Install plastic anchor
and screw here
13
½
Level, measure, mark
and screw here
9
A
1234
A. Find the drain nipple depth on the Tube Cutting Chart (left). Measure and mark the specified trim length on the insert tube at the nearest 1/4” groove.
B. Cut the tube at the groove using a sharp utility knife to ensure a square, flat cut. C. Clean burrs from the cut end by using emery paper.
1/4
9
5/8
4
½
2
13
Drain
Carrier stud placement If using in-wall carrier set bearing as shown above.
6
LOOKING AT WALL
DRAIN
3"
3¼"
Install 1/2” x 3/8” compression straight stop with the handle facing
floor.
B
C
32
½
C D
A. Clean Face of drain nipple. B. Install the clear inspection disc with the compression nut. C. Slowly pour water into the drain. D. Use a flashlight to check the pitch/slope no water should be
present in the inspection disc or nipple.
E. Remove disc and nut after inspection.
7
INCORRECT
Not centered
A
A. Hang bowl on the bracket and check tail pipe alignment, then remove the bowl
and adjust the bracket as needed. Re-hang and re-check bowl alignment with the drain line. Tail pipe should align with center of drain line.
B. Mark anchor holes then remove bowl without moving hanger bracket.
D
LUBRICANT
D. Apply lubricant to the outside of the rubber
bushing and ribbed inside area. E. Insert tube and bushing. IMPORTANT Be sure arrow tab is at the 12:00 position.
E
Arrow tab UP
CORRECT
Centered
B
10 12
Apply lubricant to tailpipe of housing.
Place hose clamp and compression nut onto
the housing tailpipe.
4
Cut away wall
Lift drain line & brace with mending plate
Adjust drain to achieve pitch only if standing water is present (code requires 1/4” drop per foot of drain line for proper pitch). Seal wall according to code.
8
10
11
12
Determine the drain nipple length by measuring the distance between the back of the sanitary tee (or elbow) to the front edge of the nipple.
11
Drill holes with 3/16”
masonry bit for the lower anchor screws and insert plastic anchors.
Hang the bowl inserting tailpipe into bushing, and tighten coupling and hose clamp. Install anchor screws with washers.
CAUTION After removing any ur inal from the
drain line, it ’s normal for ce rtain naturally occurring, but pote ntially hazardous sewer gases to escape through the opening until the waterless cartridge is installed properly int o the waterless urinal. If you
removing the urinal from the w all, temporarily wedge paper towels or a rag into the drain hole t o reduce any outflow of sewer gases, and remove the paper towels or rag pr ior to completing the urinal or cartrid ge
installation. Never smoke, have an op en flame, or place your nose or mouth near op en drain lines or waterless urinal housings into which a cartridge is not yet p
mask when removing or installing any wate rless urinal or cartridge to reduce poten tial exposure to any such gases.
www.SloanValve.com The information in this document is subject to change without notice. © 2015 Sloan Valve Company All rights reserved.
need to leave an open drain line unattended after
roperly installed. You also can wear a breathing
13
C
A
B
Connect battery A to wire B.
Wait 1 minute for system to start up.
14
Put adaptor onto stop then attach supply line to adapter. Turn water on and assure there are no connection leaks.
15
Wave hand under IR switch to
activate test rinse and ensure there is no standing water in housing. System will operate automatically every 48 hours from battery plug in.
16
CORRECT
DOWNHILL PITCH/SLOPE
(MEETS CODE)
If standing water exists, line is clogged or there is improper slope installed in housing. See step 4, correct and reinstall urinal
17
Caulk the bowl to the wall if
there is good flow and no leaks or standing water in housing.
18
CARTRIDGE
INSTRUCTIONS
Install cartridge as per the cartridge instruction sheet.