1
®
HYB-4000 HYBRID URINAL
with Jetrinse Solution Technology
NEW CONSTRUCTION
INSTALLATION INSTRUCTIONS
BEFORE STARTING INSTALLATION:
•
IMPORTANT Do not install on copper DWV
due to copper’s susceptibility to corrosion.
•
Check rough-in height to achieve 24” rim height
(17” rim height for ADA).
•
Check slope. Downhill slope, per code, is essential
because waterfree urinals depend on gravity flow.
•
Check DWV material. Suitable materials include
cast iron, PVC, ABS and galvanized steel.
TUBE CUTTING CHART
•
Measure drain nipple depth (inches) to find trim
length (inches)
•
13 7/8” or more DO NOT CUT
•
3 3/4” or less DO NOT USE TUBE
OR LESS TRIM
13 ¾" ¼"
13 ½ ½
13 ¼ ¾
13 1
12 ¾ 1¼
12 ½ 1½
12 ¼ 1¾
12 2
11 ¾ 2¼
11 ½ 2½
11 ¼ 2¾
11 3
10 ¾ 3 ¼
10 ½ 3 ½
CUSTOMER CARE
1-800-982-5839
customer.service@sloanvalve.com
OR LESS TRIM
10 ¼" 3 ¾"
10 4
9 ¾ 4 ¼
9 ½ 4 ½
9 ¼ 4 ¾
9 5
8 ¾ 5 ¼
8 ½ 5 ½
8 ¼ 5 ¾
8 6
7 ¾ 6 ¼
7 ½ 6 ½
7 ¼ 6 ¾
7 7
OR LESS TRIM
6 ¾" 7 ¼"
6 ½ 7 ½
6 ¼ 7 ¾
6 8
5 ¾ 8 ¼
5 ½ 8 ½
5 ¼ 8 ¾
5 9
4 ¾ 9 ¼
4 ½ 9 ½
4 ¼ 9 ¾
4 10
1
½" to ¾"
for ADA
10"
installation
*
standard 24" rim
16”
finished floor
Set drain line height 17” from finished floor
(standard 24” rim) or 10” for ADA installation.
Threaded nipple should extend 1/2 to 3/4” from wall.
* IMPORTANT Nipple must not extend more than
3/4” past the finished wall
5
14¼"
Install plastic anchor
and screw here
Measure and mark rough in. If in-wall carrier
is not used. Use a 5/16” masonry bit to drill
hole, then install the hanger bracket with
one plastic anchor and screw.
Install 1/2” x 3/8” compression
straight stop with the handle facing
floor.
9
A
1234
A. Find the drain nipple depth on the Tube
Cutting Chart (left). Measure and mark the
specified trim length on the insert tube at the
nearest 1/4” groove.
B. Cut the tube at the groove using a sharp
utility knife to ensure a square, flat cut.
C. Clean burrs from the cut end by using
emery paper.
1 "
Drain
Carrier stud placement If
using in-wall carrier set
bearing as shown above.
6
LOOKING AT WALL
B
C
⁄
1
3¼"
DRAIN
2¼
32
14¼
C D
A. Clean Face of drain nipple.
B. Install the clear inspection disc with the compression nut.
C. Slowly pour water into the drain.
D. Use a flashlight to check the pitch/slope no water should be
present in the inspection disc or nipple.
E. Remove disc and nut after inspection.
7
3"
INCORRECT
Not centered
A
A. Hang bowl on the bracket and check tail pipe alignment, then remove the bowl
and adjust the bracket as needed. Re-hang and re-check bowl alignment with the
drain line. Tail pipe should align with center of drain line.
B. Mark anchor holes then remove bowl without moving hanger bracket.
D
LUBRICANT
D. Apply lubricant to the outside of the rubber
bushing and ribbed inside area.
E. Insert tube and bushing. IMPORTANT Be sure
arrow tab is at the 12:00 position.
E
Arrow
tab UP
CORRECT
Centered
10
Apply lubricant to
tailpipe of housing.
Place hose clamp and
compression nut onto
the housing tailpipe.
4
Cut away wall
Lift drain line & brace
with mending plate
Adjust drain to achieve pitch only if standing water is present
(code requires 1/4” drop per foot of drain line for proper
pitch). Seal wall according to code.
8
11
12
B
Determine the drain nipple length by
measuring the distance between the back
of the sanitary tee (or elbow) to the front
edge of the nipple.
11
Drill holes with 3/16”
masonry bit for the
lower anchor screws
and insert plastic
anchors.
12
Hang the bowl inserting
tailpipe into bushing, and
tighten coupling and
hose clamp. Install anchor
screws with washers.
10
CAUTION After removing any ur inal from the
drain line, it ’s normal for certain naturally occur ring,
but pote ntially hazardous sewer gases to escape
through the opening until the waterless cartridge
is installed properly int o the waterless urinal. If you
removing the urinal from the w all, temporarily wedge paper towels or a
rag into the drain hole t o reduce any outflow of sewer gases, and remove
the paper towels or rag pr ior to completing the urinal or cartrid ge
installation. Never smoke, have an op en flame, or place your nose or
mouth near op en drain lines or waterless urinal housings into which
a cartridge is not yet properly installed. You also can wear a breathing
mask when removing or installing any wate rless urinal or cartridge to
reduce poten tial exposure to any such gases.
www.SloanValve.com
The information in this document is subject to change without notice.
© 2015 Sloan Valve Company All rights reserved.
need to leave an open drain line unattended after
13
C
A
B
Connect battery A to wire B.
Wait 1 minute for system to start up.
Note system will allow 2 manual
flushing before pausing 30 seconds.
14
Put adaptor onto stop then
attach supply line to adapter.
Turn water on and assure there
are no connection leaks.
15
Wave hand under IR switch to
activate test rinse and ensure there
is no standing water in housing.
System will operate automatically
every 48 hours from battery plug in.
16
CORRECT
DOWNHILL PITCH/SLOPE
(MEETS CODE)
If standing water exists, line is
clogged or there is improper slope
installed in housing. See step 4,
correct and reinstall urinal
17
Caulk the bowl to the wall if
there is good flow and no
leaks or standing water in
housing.
18
CARTRIDGE
INSTRUCTIONS
Install cartridge as per
the cartridge instruction
sheet.