Repair Parts and Maintenance Guide
SOLIS® EAF-275
1A/1B
4
EAF-275 Series Faucet date code 1101 and
newer. Product revised to make spray head
vandal resistant without need for special spray.
EAF-15 only works on product date code 1052
and older.
2
7A
3A
3B
3C
3D
7B
5
8
12A/12B
PARTS LIST—EAF-275 FAUCET
Item
No. Code No. Part No. Description
1A. 0335013 EAF-14-A Faucet Sensor Assembly without i.q.-cliq
1B. 0335014 EAF-16-A Faucet Sensor Assembly with i.q.-cliq
2. 3335021 EAF-1006 Cap and Solar Cell Assembly
3A. 0335012 EAF-15 0.5 gpm (1.9 Lpm) VR Aerator Spray Head –
Pre 03/2011
3B. 0335008 EAF-10 2.2 gpm (8.3 Lpm) Aerator Spray Head
3C. 0335011 EAF-13 2.2 gpm (8.3 Lpm) Laminar Flow Spray Head
3D. 0335029 EAF-51 0.35 gpm (1.3 Lpm) Multi-Laminar Spray Head
4. 3335018 EAF-1003-A Battery Replacement Kit (CR-P2)
5. 0335000 EAF-1 Faucet Mounting Kit
6. 0335007 EAF-9 Strainer (Filter)
7A. 3335019 EAF-1004 Mixer Handle Assembly and Cartridge
7B. 3335020 EAF-1005 Handle Repair Kit
8. 3335022 EAF-1007 Handle Cap
9. 3335023 EAF-1008 13” (330 mm) Flexible Supply Hose
10. 0335001 EAF-2 Solenoid
11. 3365468 ETF-312-A Trim Plate for 4” Center-set Sink
12A. 3365024 ETF-510-A Trim Plate for 8” Center-set Sink
12B. 3362022 SFP-22-A Use when needing 8” for EAF-35-A extension
13. 3335035 EAF-35-A Faucet Extension Kit
14. 3335046 EAF-40-A 2-1/4” Faucet Extension Kit. Raises faucet such
that outlet height complies with California Ofce of
Statewide Health Planning and Deveplopment
9
6
13
14
11
Faucets and
Soap Dispensers
10
The information contained in this document is subject to change without notice.
190

BACK-UP BATTERY REPLACEMENT TROUBLESHOOTING GUIDE
Replace battery when red LED indicator ashes each time faucet is in use or
when faucet stops functioning.
Step 1
Close supply stop(s).
Step 2
Loosen screw with hex rench.
Remove cap.
Step 3
Move battery retainer tab away from battery.
Remove old battery.
Dispose of properly.
Step 4
Wait three (3) minutes before
inserting new battery.
Step 5
Insert a new 6 Volt Type CR-P2 lithium
battery. The red LED will ash for
one (1) minute.
Reinstall battery cover.
If LED doesn’t ash or if it just lights
up, remove the Battery. Wait three
Faucets and
(3) minutes, then reinsert the Battery.
Soap Dispensers
Repair Parts and Maintenance Guide
SOLIS® EAF-275
1. Faucet DOES NOT function.
A. Adhesive packaging label afxed over sensor eye. Remove adhesive
label from sensor eye.
B. “Permanent Off” activated. Press button on faucet throat one time.
2. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly. Contact Sloan Technical Support.
3. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water supply stop strainer(s) clogged. Clean water supply stop
strainer(s).
INDICATOR: Solenoid valve DOES NOT produce an audible
“CLICK.”
A. Battery low. Replace battery (refer to battery replacement).
4. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall
water supply stop strainer(s). Replace strainer(s) if required.
C. Aerator is clogged. Remove, clean, and reinstall aerator. Replace
aerator if required.
D. Faucet is not working properly. Contact Sloan Technical Support.
5. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Solenoid Valve is not working properly. Contact Sloan Technical
Support.
6. LED indicator blinks when faucet is in use.
A. Battery low. Replace battery (refer to battery replacement).
7. The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
A. Supply stops are not adjusted properly. Adjust supply stops.
B. For models with integral mixing valve – mixing valve is set improperly
for the water temperature desired. Rotate mixing valve handle
clockwise to decrease water temperature or counterclockwise to
increase water temperature.
Step 6
Open supply stops.
If water ows continuously after inserting the new battery and opening the
supply stops, remove the battery. Wait three (3) minutes, then reinsert the
battery.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including
chlorine bleach) to clean faucets that may dull the
luster and attack the chrome or special decorative
nishes. Use ONLY mild soap and water, then wipe dry
with clean cloth or towel.
While cleaning the bathroom tile, protect the faucet
from any splattering of cleaner. Acids and cleaning
uids will discolor or remove chrome plating.
191