Sloan EAF-100-ISM-DPU-IC Installation Manual

INSTALLATION INSTRUCTIONS FOR OPTIMA I.Q.
ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS
FAUCET VARIATIONS
Code No. 0816542
Rev. 3 (02/11)
EAF-100 Series
Adapter Powered, Sensor Activated, Lavatory Faucets
EAF-150 Series
-ISM
-IC
-DPU
-P
-LT
Integral Spout Mixer
-Click
Feature
rain Pop Up
D Plug-in Transformer/Adapter
(EAF-100 Series) Less Transformer/Adapter
(EAF-100 Series)
Battery Powered, Sensor Activated, Lavatory Faucets
LIMITED WARRANTY
Sloan Valve Company warrants its Optima EAF-100 and EAF-150 Series Electronic Hand Washing Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts
hich prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty
w extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the battery.
THERE ARE NO WARRANTIES W HICH EXTEND BEYOND THE DESCRIPTION ON THE F ACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY M EASURE WHATSOEVER.
PRIOR TO INSTALLATION
Prior to installing the Sloan Optima EAF-100/150 Series Faucets, install the items listed below. Also, refer to rough-in illustrations.
• Lavatory/sink
• Drain line
• Hot and cold water supply lines or pre-tempered water supply line. Trim Plates When the EAF Faucet is installed on a sink that has three (3) hole punchings, a
Trim Plate should be used. separately.
ETF-607-A ETF-608-A
Trim Plate for 4” (102 mm) Centerset Sink Trim Plate for 8” (203 mm) Centerset Sink
Trim Plates must be specified and ordered
Important:
ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE
• CODES AND REGULATIONS.
FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
• KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT
• COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS.
TOOLS REQUIRED FOR INSTALLATION
• 13 mm open end wrench for male end of flex hose
• 13 mm open end wrench or nut driver for faucet retainer nut
FAUCET ROUGH-IN
MODELS EAF-100/150
1.5 gpm (5.7 Lpm) Max. Flow Aerator
Faucets with Single Line Water Supply
SPOUT
O-RING
GASKET
RETAINER
TEMPERED
SUPPLY
If a connection to separate hot
and cold water supplies is desired,
then a Bak-Chek
supplied) must be used prior to
13” (330 mm)
LONG FLEX HOSE
connecting to the faucet.
1-3/16” (30 mm)
MIN. DIA. HOLE
REQUIRED ‡
1-1/2” (38 mm)
MAX. DECK
THICKNESS ‡
®
tee fitting (not
HOT SUPPLY
MODELS EAF-100/150-ISM
MODELS EAF-100/150-ISM-DPU-IC
1.5 gpm (5.7 Lpm) Max. Flow Aerator
Faucets with Hot and Cold Water Supply
SPOUT
O-RING
GASKET
RETAINER
NUT
13” (330 mm)
LONG FLEX
HOSES
• 5/8” open end wrench for female end of flex hose (US)
• 3/4” open end wrench for female end of flex hose (International)
MIXING VALVE (Can Be
Set and Removed)
1-3/16” (30 mm)
MIN. DIA. HOLE
REQUIRED ‡
1-1/2” (38 mm)
MAX. DECK
THICKNESS ‡
COLD
SUPPLY
POP UP — MODELS EAF-100/150-ISM-DPU-IC
2-3/8
(60 mm)
‡ When installing the Faucet on a three (3) hole
sink, make sure that the center hole is large enough to accommodate the Faucet shank. A 1­3/16" (30 mm) minimum diameter hole is required. NOTE: A 1-7/32” (31 mm) Diameter hole is required if the deck is greater than 1/2” (13 mm) thick.
ONLY
5-9/16”
(142 mm)
24º
6-7/8”
(175 mm)
2-3/8 (60 mm) 2-3/4 (70 mm)
1 - INSTALL FAUCET
Install Faucet with
emove Nut, Faucet Retainer
R
A
and Gasket.
Do Not remove the O-ring from base of Faucet.
O-RING — DO NOT REMOVE
GASKET
FAUCET RETAINER
NUT
B
O-ring into the center hole
n deck or lavatory —
i 1-3/16" (30 mm) min.
hole required. Note:
If installing the Faucet on a three (3) hole sink, a Trim Plate should be installed at this time.
FAUCET
O-RING
CENTER HOLE IN DECK OR LAVATORY
2 - SLIDE GASKET OVER FLEX HOSE(S) AND SECURE WITH FAUCET RETAINER AND NUT
FAUCET
O-RING
GASKET
FAUCET RETAINER
NUT
FLEX HOSE
MODELS POWERED BY
PLUG-IN ADAPTER ONLY DO NOT pull or crimp AC
Power Line.
3 - INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP AND OPEN SUPPLY STOPS
IMPORTANT: before
A
B
Flush dirt, debris, and sediment from Supply Line(s)
Connecting Flex Hoses.
Install Strainer and Flex Hose onto Supply Stop.
Tighten the Flex Hose (with Strainer in place) securely to the Supply.
SU
PPLY
FLEX HOSE
STRAINER
LINE/ STOP
Open Supply Stop(s).
C
4 - EAF-100 MODELS: PLUG ADAPTER INTO RECEPTACLE
ALL MODELS: REMOVE LABEL FROM SENSOR
ADAPTER
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
90-264 VAC/
6.75 VDC
PLUG-IN ADAPTER
SENSOR
LABEL
Electrical outlet must be within 24” of faucet unless extensions are used.
DAISY CHAIN ELECTRICAL CABLE
2
DAISY CHAIN ELECTRICAL CABLE
DAISY CHAIN ELECTRICAL CABLE
TO ADDITIONAL FAUCETS (6 MAX.)
5 - ACTIVATE FAUCET
20-25mm
2 mm
ctivate faucet by pressing
A
A
the button one (1) time, then immediately step away.
Faucet will run for four (4) seconds and the range will
utomatically adjust to it’s
a environment.
Wait ten (10) seconds after water shuts off before using Faucet.
IC MODELS
STANDARD MODELS
6 - SET AND FIX TEMPERATURE
Activate Faucet and check
B
for leaks. If Faucet does not function,
efer to the Troubleshooting
r section of this instruction manual.
Adjust Lever to set temperature.
A
HOT LIMIT STOP ADJUSTMENT
A
B
C
Optional —
B
then remove lever and plug hole with Cap.
To fix temperature, set lever to the desired position,
D E F
3
Loading...