Sloan BASYS Maintenance Manual

EFX-1XX SERIES EFX-2XX SERIES
6C
8
16
9
17
18
6B
2
6A
5
11
Repair Parts and Maintenance Guide
Repair Parts and Maintenance Guide
BASYS® Infrared Sensor Activated
PARTS LIST—BASYS FAUCETS Item
No. Code No. Part No. Description
1. Mid Mount Faucet Assembly Mid Mount Faucet Assembly with Mixer High Mount Faucet Assembly High Mount Faucet Assembly with Mixer
2. 3324104 EFX-1002-A 0.5 gpm/1.9 Lpm Multi-Lam Insert (includes
3324103 EFX-1001-A 1.5 gpm/5.7 Lpm Aerated Stream Insert (includes
3324102 EFX-1000-A 1.5 gpm/5.7 Lpm Laminar Stream Insert (includes
3A. 3324122 EFX-15-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly
Mid Mount (Green)
3324123 EFX-16-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly
3B. 3324124 EFX-17-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly
3324125 EFX-18-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly
4. 0324019 EFX-19 Strainer (Filter)
5. 3324128 EFX-7-A Battery Pack Assembly
3B
3A
6A. 3324118 EFX-1-A Crown Assembly 6B. 3324119 EFX-3-A Solar Crown Assembly 6C. 3324120 EFX-4-A Solar Crown with LCD Assembly
7. Mixer Handle Assembly
8. 0324035 EFX-33 Handle Cap
4
9. 0335000 EAF-1 Faucet Mounting Kit (Pedestal)
10. 3325023 EAF-1008 13” (330 mm) Flexible Supply Hoses (2)
11. 3324101 EFX-26-A Trim Plate for 8” Centerset Sink
1
12. 3324100 EFX-20-A Trim Plate for 4” Centerset Sink
13. 0335009 EAF-11 Plug-in Voltage Adapter (US) 0335041 EAF-41 Plug-in Voltage Adapter (EU) 0335039 EAF-39 Plug-in Voltage Adapter (UK) 0335037 EAF-37 Box Type Voltage Adapter
14. 0335024 EAF-24-A 11-13/16” (300 mm) Extension Cable 0335025 EAF-25-A 47-1/4” (1200 mm) Extension Cable
7
0335015 EAF-17-A 126” (3200 mm) Extension Cable
15. 0335023 EAF-23-A Splitter
16. 3326009 MIX-60-A Mechanical, Below Deck Mixing Valve
17. 0326045 MIX-135-A Thermostatic, Below Deck Mixing Valve
18. 3365461 ETF-617-A Bak-Chek Tee
NOTE: If changing  ow rate caddy and spray insert must be changed in conjunction. — in Item No. column = Not shown in illustration — in Code No. and Part No. column = Not sold separately
insert, o-ring, 2.5 mm allen key and removal tool)
insert, o-ring, 2.5 mm allen key and removal tool)
insert, o-ring, 2.5 mm allen key and removal tool)
– Mid Mount (Blue)
– High Mount (Green)
– High Mount (Blue)
Faucets and
Soap Dispensers
10
15
The information contained in this document is subject to change without notice.
12
14
13
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
ADAPTER
TO ADDITIONAL FAUCETS (6 MAX.)
131
DAISY CHAIN ELECTRICAL CABLE
DAISY CHAIN ELECTRICAL CABLE
The information contained in this document is subject to change without notice.
...1x
...2x
...3x
Activate 12HR
Deactivate
Activate 24HR
Repair Parts and Maintenance Guide
133
The information contained in this document is subject to change without notice.
BASYS® Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and should not require resetting unless under extreme situations.
Wait, until LED  ashes GREEN.
IR Activation (see previous page).To enter programming mode place  nger on IR clic for 2 times then remove. Light on side of crown should blink to indicate programming mode.
SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x 8x
5x
NOTE: Replace Battery when LED1 indicator fl ashes red each time faucet is in use or when faucet stops functioning. LED1 is identifi ed by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening hex screw located on underside of spout and slide crown down and lift off.
NOTE: Screw is captive within faucet body and will not fall out.
Remove battery pack assembly by lifting out of spout.
Open battery pack assembly by pushing in tabs on side of assembly.
Remove all four (4) AA-cell batteries from battery pack.
Insert four (4) NEW AA-cell batteries into battery pack assembly cartridge.
NOTE: Insure batteries are installed with proper polarity. The cover of the case indicates polarity of batteries. Improper polarity will not harm the faucet. Improper polarity will cause the faucet not to operate.
Replace cover of the battery pack assembly and reinsert assembly into faucet.
Slide on crown and secure.
UNLOCK
LOCK
SPARE FILTER
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x 8x
5x
1x
2x
3x
4x
6x - Factory Setting
7x 8x
5x
1x
2x
3x
4x
6x - Factory Setting
7x 8x
5x
UNLOCK
Cover IR clic until LED  ashes 4x - hold on until LED  ashes 1x to 8x, from minimum to maximum. See diagram below. Release when requested range is reached.
Faucets and
Soap Dispensers
OPERATION
As the user’s hands enter the beam’s effective range, the beam is re ected back into the sensor receiver and activates the solenoid valve allowing water to  ow from the faucet. Water will  ow until the hands are removed or until the faucet reaches its automatic time out limit setting.
SET AND FIX TEMPERATURE AND ADJUST HOT LIMIT STOP
Adjust lever to set temperature.
Optional — To  x temperature, set lever to the desired position, then remove lever and plug hole with Cap.
Optional Hot Limit Stop Adjustment — To adjust the hot/ cold mix (factory set at 50/50) remove the lever.
Check to make sure dot is in center position before beginning adjustment.
Faucet may be adjusted in 10º increments.
Faucets and
Soap Dispensers
2 mm
2 mm
Repair Parts and Maintenance Guide
BASYS® Infrared Sensor Activated
Steps to Default IR Function Activate Function Setting Clic
IR Activation Cover IR clic approximately for 2 sec. –– –– until LED will  ash GREEN 1x - then remove  nger from IR clic (Active for 5 sec.)
Cleaning IR activation; Cover IR clic 2x - con rmation 2 min. –– Mode of the function is active by a couple  ashes by the LED; to return to normal operation cover IR clic 1x or the faucet will automatically return to normal function after 2 min.
12/24 Line See below. Off Off Purge 12HR Feature 24HR
Sensor See page 123. 6 1-8 Range Adjustment
Reset IR activation; Cover IR clic 2x; LED will  ash 5x Manually –– Electronics Cover IR clic 1x for 5 sec. until LED  ashes 4x, then remove  nger from IR clic Wait for 20 sec. (After 10 sec. water will  ow for 6 sec. and automatically adjust to environment)
Security Off After 90 seconds (max) of hand and/or object On –– within sensor appears permanent, water ow will stop and will remeasure environment
Please contact factory for more extensive programming options.
12/24 LINE PURGE FEATURE
This feature will operate the faucet every 12 or 24 hours since last use, if not used to prevent stagnant water conditions.
Default purge duration is two minutes.
Consult factory regarding other timing options.
IR activation (see above). Cover IR clic approximately 24 sec. (ignore LED indications during this period). Release when requested program is reached. (See diagram to right). Programming mode will time out after 2 minutes if no changes
1x 24 sec
+ ...
Deactivate
...1x
are made.
The information contained in this document is subject to change without notice.
132
Activate 12HR
...2x
Activate 24HR
...3x
Loading...
+ 4 hidden pages