Read this manual ca
or operating your new air conditioning
unit. Make sure to save this manual for
futu
re r
efe
ence.
r
OTE:
r
efully befo
r
e installing
Page 3
User Notices
For correct installation and operation, please read all instructions carefully.
Before reading the instructions, please be aware of the following items:
Prohibit installing the wired controller at wet or sunshine places.
Do not knock, throw or frequently disassemble the wired controller.
Do not operate the wired controller with wet hands.
Do not remove or install the wired controller by yourself. If there is any
question, please contact our after-sales service center.
The wired controller is a general model, applicable for several kinds of units.
Some functions of the wired controller are not available for certain kinds of
units, more details please refer to the owner’s manual of unit. The setting of such unavailable function will not affect unit’s operation.
Shielding status (Buttons, temperature, ON/OFF, mode or
energy saving is shielded by remote monitor)
No. Symbols
1
2
3
4
5
6
8
9
13
2
Page 8
No. Symbols
Instructions
Current set fan speed
Memory function (Memory in power failure)
Save function
X-fan function
Remind to clean the filter
Timer on status
Gate card pulled-off status or nobody presented status
Quiet function
22 Function lock
14
15
16
17
18
19
20
21
3
Page 9
2 Buttons
2.1 Button Graphics
Fig. 2 Button graphics
4
Page 10
2.2 Function Instructions of Buttons
3
ON/OFF/BACK
5
<
8
>
No. Button name Button Function
Set low speed, low-medium speed, medium speed,
1 FAN
medium-high speed, high speed, turbo and auto speed.
2
6
4 SWING Set up&down swing and set left&right swing
∧
∨
(1) Set temperature
(2) Set parameter
(3) Move option cursor
(1) Turn on or turn off unit
(2) Return to last page
(1) Set related function on or off
(2) Move option cursor
(3) Set parameter
5
Page 11
No. Button name Button Function
(1) Enter menu page
7 MENU/OK
(2) Confirm setting
Set auto, cooling, dry, fan and heating modes for indoor
9 MODE
unit.
3 Operation Instructions
3.1 Menu Structure
Normal setting of wired controller can be set directly on the main
page, including fan speed, swing, set temperature, mode, ON/OFF. The
setting and status view of other functions can be set in corresponding
submenu. Detailed menu structure is as shown in Fig. 3.
6
Page 12
Main menu
User function menu
Air function setting
Sleep function setting
Health function setting
I-DEMAND function setting
Absence function setting
Clean function setting
Fixed-angle swing function setting
Save function setting
Auxiliary heat function setting
Dry function setting
Quiet function setting
Fahrenheit setting
Memory function setting
Low temperature dry function
Timer setting menu
Once
Daily
Weekly timer
Two week timer
Countdown timer on
Countdown timer off
Clock setting menu
Time format setting
Clock setting
View function menu
Unit status view
Current error view
Function lock menu
Unit ON/OFF lock
Mode setting lock
Temperature setting lock
Fan speed setting lock
Key lock
Fig. 3 Menu structure
7
Page 13
3.2 On/Off
When the wired control is on main page, press ON/OFF button to turn
on the unit. Press ON/OFF button again to turn off the unit. The interfaces
of On/Off status are shown in Fig. 4 and Fig. 5.
Fig. 4 Off interface Fig. 5 On interface
3.3 Mode Setting
Under On status, pressing MODE button can set mode circularly as:
8
Page 14
Note: If save function is on, auto mode is not available.
3.4 Temperature Setting
Under unit on status, pressing “∧” or “
increases or decreases set temperature by 1℃(1
” button on the main page
∨
); holding “∧” or “∨”
℉
button increases or decreases set temperature by 1℃(1℉) every 0.3s.
In cooling, dry, fan and heating mode, temperature setting range is
16℃~30℃(61
℉~86℉
). Under auto mode, set temperature cannot be
adjusted.
3.5 Fan Setting
Under On status, pressing FAN button can set fan speed circularly
as:
In unit on status, press SWING button for swing setting. Two swing
modes are available: fixed-angle swing and simple swing.
When fixed-angle swing mode is set, swing operation is as follows:
In unit on status, press SWING button to select up&down swing .
Up&down swing angle will be adjusted circularly as below:
→→→→→→→ →→→→
closed →
Select up&down swing and left&right swing through “
” or “>”
<
button. When left&right swing is selected. Left&right swing angle will
be adjusted circularly as below:
→→→→→→→→
closed→
Note:
① Turn on fixed-angle swing mode in function setting page;
① If fixed-angle swing is not available for the model, fixed-angle swing will be
invalid when the wired controller turns on fixed-angle swing mode.
10
Page 16
Simple swing mode: when fixed-angle swing mode is turned off,
swing operation is as below:
Pressing SWING button under unit on status, up&down swing frame
occurs. Then press SWING button to turn on or turn off up&down swing.
is displayed when up&down swing is on and is not displayed when
up&down swing is off. When up&down swing frame have not disappeared,
press “
<
” or “
” button to switch to left&right swing setting. Then
>
left&right swing frame occurs. In this case, press SWING button to turn on
or turn off left&right swing. is displayed when left&right swing is on
and is not displayed when left&right swing is off. For detailed operation,
please refer to Fig. 7.
11
Page 17
12 13
Page 18
Fig. 7 Swing setting
3.7 Functions Setting
Press MENU/OK button on main page to enter main menu page.
Press “
∧
” or “
∨
” or “
<
” or “
” button to select the function setting
>
symbol. Then press MENU/OK button to enter user function setting page.
Press “
∧
” or “
” button to select specific function item. Press “
∨
<
” or “
>
button to turn on or turn off this function. If the function item cann’t be set,
it will displays with gray color.Please refer to Fig. 8.
”
Page 19
Fig. 8 Function setting
14
Page 20
3.7.1 Fresh Air Function Setting
After entering user function page, press “∧” or “∨” button to select
fresh air function and press “
function. Press MENU button to adjust the mode of fresh air.
After entering fresh air mode setting, press “
adjust the mode in the range of 1~10. After setting, press MENU button
to save the setting.
The each mode means as follows:
1――The unit continuously runs for 60min, and fresh air valve runs
for 6 min.
2――The unit continuously runs for 60min, and fresh air valve runs
for 12 min.
3――The unit continuously runs for 60min, and fresh air valve runs
for 18 min.
4――The unit continuously runs for 60min, and fresh air valve runs
for 2 4 min.
5――The unit continuously runs for 60min, and fresh air valve runs
for 30 min.
” or “>” button to turn on or turn off air
<
∧
” or “
” button to
∨
15
Page 21
6――The unit continuously runs for 60min, and fresh air valve runs
for 36 min.
7――The unit continuously runs for 60min, and fresh air valve runs
for 42 min.
8――The unit continuously runs for 60min, and fresh air valve runs
for 48 min.
9――The unit continuously runs for 60min, and fresh air valve runs
for 54 min.
10――The unit continuously runs for 60min, and fresh air valve
always runs.
3.7.2 Sleep Function Setting
After entering user function page, press “
” or “∨” button to select
∧
sleep function and press “<” or “>” button to turn on or turn off sleep
functio1n with auto saving.
If this function is turned on, the unit will operate according to the
preset sleep curve to provide comfortable sleep environment.
Note:
① In fan or auto mode, sleep function is not available;
16
Page 22
② Sleep function will be cancelled when turning off the unit or switching modes.
3.7.3 Health Function Setting
After entering user function page, press “∧” or “∨” button to select
health function and press “<” or “>” button to turn on or turn off health
function with auto saving.
3.7.4 I-DEMAND Function Setting
After entering user function page, press “∧” or “
IDEMAND function option and press “
<
” or “
” button to turn on or turn
>
” button to select
∨
off this function with auto saving.
Note:
① This function is only available in cooling mode.
② When this function has been set, set temperature is displayed in 27℃(81℉).
In this case, temperature setting and fan speed setting are shielded.
③ This function will be cancelled when turning off the unit or switching modes.
④ This function and sleep function cannot be on simultaneously. If I-demand
function is set firstly and then sleep function is set, I-demand function will be
cancelled while sleep function will be valid, and vice versa.
17
Page 23
3.7.5 Absence Function Setting
After entering user function page, press “∧” or “∨” button to select
holiday function option and press “
<
” or “
” button to turn on or turn off
>
this function with auto saving.
This function is used to maintain indoor temperature so that unit can
realize fast heating.
Note:
① This function is only available in heating mode;
② When this function has been set, set temperature is displayed in 8℃(46℉).
In this case, temperature setting and fan speed setting are shielded;
③ This function will be cancelled when switching modes;
④ This function and sleep function cannot be on simultaneously. If absence
function is set firstly and then sleep function is set, absence function will be
cancelled while sleep function will be valid, and vice versa.
3.7.6 Memory Function Setting
After entering user function page, press “∧” or “∨” button to select
memory function and press “<” or “>” button to turn on or turn off
memory function with auto saving.
18
Page 24
3.7.7 Save Function Setting
After entering user function page, press “∧” or “∨” button to select
save function and press “<” or “>” button to turn on or turn off save
function. Press MENU button to enter save function setting page.
After entering save function setting page, press “
select cooling or heating limitation temperature. After selecting cooling or
heating limitation temperature, press “
limitation temperature value. After setting, press MENU button to save
the setting.
Note: When save function has been set, auto mode cannot be set.
” or “∨” button to adjust
∧
” or “>” button to
<
3.7.8 Auxiliary Heating Function Setting
After entering user function page, press “
auxiliary heating function and press “<” or “>” button to turn on or turn
off this function with auto saving.
19
” or “∨” button to select
∧
Page 25
3.7.9 X-fan Function Setting
After entering user function page, press “∧” or “
dry function option and press “
<
” or “
” button to turn on or turn off this
>
” button to select
∨
function with auto saving.
Note:
① This function is only available in cooling mode and dry mode;
② When this function is on, if the air conditioner is turned off, the indoor fan will
still operate at low speed for a while to blow the residual water inside the air
duct.
3.7.10 Quiet Function Setting
After entering user function page, press “∧” or “∨” button to select
quiet function and press “<” or “
function with auto saving.
Note: This function is only available in cooling mode, heating mode
and auto mode.
” button to turn on or turn off this
>
20
Page 26
3.7.11 Filter Clean Reminder Setting
After entering user function page, press “∧” or “∨” button to select
clean function option and press “
this function. Press MENU button to enter the setting page of filter clean
reminder function.
After entering the setting page of filter clean reminder function, press
“∧” or “
button to set pollution level; press “
accumulating time setting and then press “<” or “>” button to set
required time. After setting, press MENU button to save the setting.
operating time is 5500~10000 hours, with 500 hours in each increase or
decrease.
operating time is 1400~5000 hours, with 400 hours in each increase or
decrease.
operating time is 100~1000 hours, with 100 hours in each increase or
” button to select pollution level and then press “
∨
When level 1 is selected, the adjusting range of accumulating
When level 2 is selected, the adjusting range of accumulating
When level 3 is selected, the adjusting range of accumulating
” or “>” button to turn on or turn off
<
” or “>”
<
” or “∨” button to select
∧
21
Page 27
decrease.
This function is used to remind you to clean the filter when the unit’s
own operating time is reach your setting.
Whenever you turn off this function, the unit’s operating time will be
zero clearing.
3.7.12 Fahrenheit Temperature Setting
After entering user function page, press “∧” or “∨” button to select
Fahrenheit temperature function and press “<” or “
or turn off this function with auto saving. After closing this function,
Celsius temperature will be displayed.
” button to turn on
>
3.7.13 Fixed-angle Swing Mode Setting
After entering user function page, press “∧” or “∨” button to select
lock swing function option and press “
off this function with auto saving.
Note: If fixed-angle swing function is not available for the connected
unit, this function will be cancelled automatically after setting.
” or “>” button to turn on or turn
<
22
Page 28
3.7.14 Low-temperature Drying Function Setting
After entering user function page, press “∧” or “∨” button to select
low-temperature drying function and press “
” or “>” button to turn on or
<
turn off this function with auto saving.
Note:
① This function is only available in dry mode;
② When low-temperature drying function is on, the displayed set temperature in
dry mode is 12 ℃ (54℉ ). This function will be off automatically after
readjusting set temperature.
3.8 Unit Status View
Press MENU button to enter the menu and select the function
symbol to be viewed. Then press MENU button to enter view function
page. Press “
MENU button to enter unit status view page. Press BACK button to return
to the last page. Please refer to Fig. 9.
The following statuses can be viewed: if defrosting is operating; if
auxiliary heating is operating; residual time of filter cleaning reminder;
indoor ambient temperature; outdoor ambient temperature.
∧
” or “
” button to select status view function. Press
∨
23
Page 29
Fig. 9 Status View
24
Page 30
3.9 Current Error View
When error occurs in the unit, error symbol will be displayed on the
main page of wired controller to indicate that the unit is with error. In this
case, you can enter error view page to view the current error.
Press MENU button to enter the menu and select the function symbol
to be viewed. Then press MENU button to enter view function page. Press
“∧” or “
enter error view page. If there are too many errors, press “
turn pages. Press BACK button to return to the last page. Please refer to
Fig. 10.
” button to select error information. Press MENU button to
∨
” or “
∧
25
∨
” to
Page 31
Fig. 10 Current Error View
26
Page 32
3.10 Timer Setting
The wired controller can set 6 kinds of timer: one time clock timer,
everyday timer, one week timer, two week timer, countdown timer on and
countdown timer off. Select timer symbol after entering menu page.
Press MENU button to enter timer setting page. Press “
to select one kind of timer. Press “
this timer. Please refer to Fig. 11.
Fig. 11 Turn on or turn off timer
<
” or “
” button to turn on or turn off
>
27
∧
” or “
” button
∨
Page 33
3.10.1 One Time Clock Timer
The wired controller can set one time clock timer. If the unit is off,
timer on can be set. If the unit is on, timer off can be set. This timer will be
carried out for only once when timer time is reached and then the timer
will be off automatically.
In timer function setting page, when one time timer is selected, press
“<” or “
button to enter timer time setting page, as shown in Fig. 12.
“∧” or “
decreases time rapidly. After finishing setting, press MENU button to
save timer time.
” button to turn on or turn off this timer function. Press MENU
>
Press “
” or “
<
” button to adjust time. Holding “
∨
” button to select timer hour or minute and press
>
28
” or “∨” button increases or
∧
Page 34
Fig. 12 Setting page of one time clock timer
Note:
① If this timer function is turned on, when the unit is turned on or turned off, this
timer function will be cancelled automatically.
3.10.2 Daily Timer
In daily timer, user can set eight segments of timer individually. The
individual segment will be valid only when it is turned on. In each
segment, you can set time, unit ON/OFF, set temperature in cooling (it is
valid only when the current mode is cooling), set temperature in heating
29
Page 35
(it is valid only when the current mode is heating). Please refer to Fig. 13.
After entering daily timer setting page, press “
select setting item. Press “
MENU button to save setting.
” or “
∧
Fig. 13 Daily timer setting
” button to adjust the value. Press
∨
<
” or “
” button to
>
30
Page 36
3.10.3 Weekly Timer
The user can set the everyday timer content for a week. In each day,
the user can set eight segments of timer content. The unit will execute
corresponding timer setting in a week.
After entering weekly timer setting page, press “
select the day to be set. Then press MENU button to enter timer
programming of that day. Press “
set. Press “
save setting. Please refer to Fig. 14.
∧
” or “
” button to adjust the content. Press MENU button to
∨
<
” or “
31
” button to select the item to be
>
<
” or “
” button to
>
Page 37
32 33
Page 38
Fig. 14 Weekly timer setting
3.10.4 Two Week Timer
The user can set the everyday timer content for two weeks. In each
day, the user can set eight segments of timer content. The unit will
execute corresponding timer setting in two weeks.
In timer function setting page, press “
∧
” or “
” button to select two
∨
week timer setting and then press MENU button to enter two week timer
menu page. Press “
∧
” or “
” button to select current week option and
∨
Page 39
then press “
<
” or “
” button to set current week as first week or
>
second week. Press MENU button to save current week setting. Please
refer to Fig. 15.
Fig. 15 Setting of current week
After entering two week timer menu page, press “
∧
” or “
” button to
∨
select the two week schedule option and then press MENU button to
enter two week timer programming. After entering two week timer setting
page, press “
<
” or “
” button to select the day to be set. Then press
>
MENU button to enter timer programming of that day. Press “
button to select the item to be set. Press “
34
∧
” or “
” button to adjust the
∨
” or “>”
<
Page 40
content. Press MENU button to save setting. Press BACK button to exit
this page. The setting symbols please refer to weekly timer setting.
3.10.5 Countdown Timer
Countdown timer includes timer on and timer off. Unit On/Off after a
desired hour can be set. In unit on status, timer off can be set, or timer off
and timer on can be set simultaneously. In unit off status, timer on can be
set, or timer off and timer on can be set simultaneously. If timer off in x
hours and timer on in y hours are set simultaneously in unit on status, the
unit will be off in x hours and then the unit will be on in y hours after timer
off.
After entering timer on setting page, press “
∧
” or “
” button to
∨
increases or decreases timer time by 0.5h. Press BACK button to return
to the last page. Please refer to Fig. 16.
35
Page 41
Fig. 16 Countdown timer on
After entering timer off setting page, press “
∧
” or “
” button to
∨
increases or decreases timer time by 0.5h. Press BACK button to return
to the last page. Please refer to Fig. 17.
36
Page 42
Fig. 17 Countdown timer off
If timer function is on, the set hours will decrease as the unit
operation time increases. In this case, residual hours can be viewed after
entering timer setting page. This timer function will be carried out for only
once and then it will be cancelled automatically.
Note: If this timer function is turned on, when the unit is turned on or
turned off, this timer function will be cancelled automatically.
37
Page 43
3.11 Clock Setting
3.11.1 Time Format Setting
The user can set the time format in 12-hour system or 24-hour
system. Select clock symbol in menu page and then press MENU button
to enter clock setting page. Press “
and then press “
system. Please refer to Fig. 18.
<
” or “
” button to select 12-hour system or 24-hour
>
Fig. 18 Time format selection
∧
38
” or “
” button to select time format
∨
Page 44
3.11.2 Clock Setting
Select clock symbol in menu page and then press MENU button to
enter clock setting page. Press “
then press MENU button to enter time setting.
Press “
month, day; press “
MENU button to save setting. Please refer to Fig. 19.
<
” or “
” button to select setting items: hour, minute, year,
>
” or “
∧
∨
” or “
∧
” button to set the value and then press
” button to select time set and
∨
39
Page 45
Fig. 19 Clock setting
40
Page 46
3.12 Lock Setting
Select lock symbol in menu page and then press MENU button to
enter lock setting page. Press “
locked and then press “
Fig. 20.
Items can be locked: ON/OFF, mode setting, temperature setting,
fan speed setting, key lock. After locking, the corresponding item cannot
be set through buttons.
If the keys are locked, all keys cannot be operated after returning to
the main page. Please unlock according to the instructions on main page.
During unlocking, press MENU button, press “<” button and then press
“
” button to unlock keys.
>
<
” or “
” or “
∧
” button to lock or unlock. Please refer to
>
” button to select the item to be
∨
41
Page 47
Fig. 20 Lock setting
4 Installation Instructions
4.1 Parts and Dimension of Wired Controller
Fig. 21 Dimension of wired controller
42
Page 48
Fig. 22 Parts of wired controller
No. 1 2
3
Panel of wired
controller
1
Quantity
4.2 Installation Requirements
(1) Prohibit installing the wired controller at wet places;
(2) Prohibit installing the wired controller at the places with direct
(3) Prohibit installing the wired controller at the place near high
Name
Screw M4X25 Soleplate of wired
3 1
sunshine;
temperature objects or water-splashing places.
43
controller
Page 49
4.3 Installation Methods
Fig. 23 Installation diagram for wired controller
Fig. 23 is the simple installation process of wired controller; please
pay attention to the following items:
(1) Before installation, please cut off the power for indoor unit;
(2) Pull out the 2-core twisted pair wire from the installation hole on
44
Page 50
wall, and pull this wire through the “ ” hole at the rear side of
the soleplate of wired controller;
(3) Stick the soleplate of wired controller on the wall and then use
screw M4×25 to fix soleplate and installation hole on wall
together;
(4) Connect two-core twisted pair wire to H1 and H2 wiring column
and then fix the screws(it is needn’t to differentiate polarity. );
(5) Block the two-core wire into the groove at the left side of wiring
column; bundle the front panel of wired controller to its
soleplate.
Note:
If the procedures in point 2 and point 5 mentioned above is hard to be done as
the diameter of selected communication wire is big, please peel off the sheathed
layer in appropriate length according to actual situation.
45
Page 51
4.4 Disassembly
Fig. 24 Disassembly diagram for wired controller
46
Page 52
NOTE CONCERNING PROTECTION OF
ENVIRONMENT
This product must not be disposed of via normal household waste after its service life, but must be
taken to a collection station for the recycling of electrical and electronic devices. The symbol on the
product, the operating instructions or the packaging indicate such disposal procedures. The materials
are recyclable in accordance with their respective symbols. By means of re-use, material recycling or
any other form of recycling old appliances you are making an important contribution to the protection
of our environment. Please ask your local council where your nearest disposal station is located.
In case of quality problem or other please contact your local supplier or authorized service center.
Emergency number: 112
PRODUCER
SINCLAIR CORPORATION Ltd.
1-4 Argyll St.
London W1F 7LD
Great Britain
www.sinclair-world.com
This product was manufactured in China (Made in China).
REPRESENTATIVE
SINCLAIR EUROPE spol. s r.o.
Purkynova 45
612 00 Brno
Czech Republic
TECHNICAL SUPPORT
SINCLAIR Global Group s.r.o.
Purkynova 45
612 00 Brno
Czech Republic