Please read the guide carefully before use.
Safety Precautions
• Do not turn on the plug with a wet hand, otherwise there might be the risk of electric
shock.
• When the body is inclined, please handle this with the power cut off.
• Do not touch the transduction piece upon starting, otherwise you will have the feel of
pain.
• Do not disassemble the unit without cutting off the power to avoid an electric shock.
• Do not replace the power cord without authorization.
IMPORTANT!
• This appliance is for use in home and similar environments:
- shops, offices or staff kitchens of other work places;
- in farm houses;
- customers of hotels, motels or other accommodation units;
- breakfast service of accommodation units.
This appliance can be operated by children of 8 years and above, people with limited
physical, auditory and cognitive skills or people with lack of experience and knowledge
as long as they are under supervision or they are provided instructions regarding the
operation of the appliance. In case they are not older than 8 years old or unsupervised,
children should not clean or maintain the device.
Keep the appliance and its cable from the reach of children aged <8.
Technical Data
Mist output: About 250ml/hr.
Mist type: Cool mist
Tank capacity: 2L
Power off when lack of water
AC220-240V, 50Hz, 18W
Suggestion for User
Humidify with cool boiled water or distilled water. Clean the transducer, water tank, base
on a weekly basis. Replace the used water in the water frequently to keep the unit clean.
When the unit is not to be used for a long time, do not store water in the water tank and
water bath. During storage, clean, mop up or air-dry all parts and then place them in the
original package.
- 1 -
Proper Operation
• Place the body horizontally at a suitable place.
• Take out and overturn the water tank, screw off the tank cover, inject clean tap water.
• Connect the unit to power supply, turn on the power switch and the humidifying indicator
will be illuminated.
• There is no staged adjustment of humidifying capacity, which is set to the dryness of
your room.
• When there is no water in the water tank ,the built-in safety device will disconnect the
atomization circuit automatically, when there is no spray output from the spray nozzle
and the water depletion indicator is illuminated (two colors of the same indicator).To
continue the operation, please cut off the power and add water into the water tank.
Operating Precautions
• Do not add hot water of above 40˚C to the water tank and water bath to avoid discoloration
or distortion.
• Do not let water flow into the body from the air outlet. Wipe off any water outside and
the body with dry cloth.
• When the room temperature is below 0˚C, please empty the water tank and water bath,
let the icing of water should damage the components.
• Do not place metals, chemicals and detergents into the water bath, otherwise there
might be poor atomization.
• When there is much water in the water bath, do not move it about, otherwise water
might overflow and flow into the body to cause troubles.
• Do not put the unit at a place with strong light or direct hot air radiation.
• Do not place the unit at an airport and try to keep it away from furniture and electric
appliances.
• Do not add water into the water bath directly.
• When the unit is not to be used for a long time. Please cut off the power and unplug
the plug.
• Never pour out the water remaining in the water remaining in the water bath without
the power turned off, otherwise the transducer will be burned out immediately.
• When the water tank is fully loaded, the unit can operate for 7-12 hours continuously
without replenishment.
Cleaning /Maintenance
Always unplug the unit before removing the water tank. Do not touch the water in the
base during operation!
Caution - risk of electric shock and damage of the product.
• Switch off the appliance and unplug it from the socket before cleaning it.
• Clean the water tank and the base regularly. Use water only, no detergents.
• Cleaning and descaling agent only to remove deposits from the transducer regularly.
- 2 -
• Make sure main body is never submerged in water.
• Clean the inner parts with a soft cloth. Do not use any solvents or aggressive cleaning
agents to clean the appliance.
• Only use the brush to clean to transducer .This should be done once a week. Only use
the soft-bristle portion of the brush.
• Change the water in the tank at least once a week if water is standing for more than
a week.
Trouble shooting
Problem: Indicator not illuminated, no air, no fog
Possible cause: The power plug is not properly plugged
Possible cause: The power switch is not turned on
Possible cause: The water level in the water bath is too high
What to do: Plug the power properly
What to do: Turn on the power switch
What to do: Pour out some water in the water bath screw down the water tank cover
Problem: Indicator illuminated with air, no fog
Possible cause: There is no water in the water tank
Possible cause: The automatic constant humidity knob is not turned on.
Possible cause: The water level float cap is not held down.
What to do: Top up the water tank
What to do: Turn on the automatic constant humidity knob clockwise
What to do: Hold down the water level float cap
Problem: Spray with odor
Possible cause: New unit
Possible cause: The water in the tank is not clean
What to do: Open the water tank
What to do: Place at a shade for 12 hours
What to do: Clean or replace the water tank
Problem: Small fog output
Possible cause:There is scale formation on the transducer
Possible cause: The water is dirty or has been stored too long
What to do: Clean the transducer
What to do: Replace with clean water
INFORMATION ABOUT USAGE FAULTS
Only use the specified voltage for the appliance. Check with your local voltage to see if
they match. To avoid any risk hazards, a damaged power cable must be changed by the
manufacturer, service organization or a likewise qualified technician. Do not attempt to
disassemble the device yourself in case of a failure, contact our call centre.