As Navico is continuously improving this product, we retain the right to make changes to the product at any time which may not be reflected in this version of the manual. Please contact your nearest distributor if you require any further assistance.
It is the owner’s sole responsibility to install and use the instrument and transducers in a manner that will not cause accidents, personal injury or property damage. The user of this product is solely responsible for observing safe boating practices.
NAVICO HOLDING AS AND ITS SUBSIDIARIES, BRANCHES AND AFFILIATES DISCLAIM ALL LIABILITY FOR ANY USE OF THIS PRODUCT IN A WAY THAT MAY CAUSE ACCIDENTS, DAMAGE OR THAT MAY VIOLATE THE LAW.
Governing Language: This statement, any instruction manuals, user guides and other information relating to the product (Documentation) may be translated to, or has been translated from, another language (Translation). In the event of any conflict between any Translation of the Documentation, the English language version of the Documentation will be the official version of the Documentation.
This manual represents the product as at the time of printing. Navico Holding AS and its subsidiaries, branches and affiliates reserve the right to make changes to specifications without notice.
Copyright
Copyright © 2010 Navico Holding AS.
Feedback from you
Your feedback is important and helps Navico ensure that this manual is a valuable resource for all marine technicians. E-mail your comments or suggestions about this manual to the following address: tech.writing@navico.com
StructureScan LSS-1 Installation manual | 1
Page 4
2 | StructureScan LSS-1 Installation manual
Compliance Statements
The StructureScan™ LSS-1 complies with the following regulations:
• FCC Part 15
• CE compliant per EN60945
• C - Tick
For more information please refer to our website: www.simrad-yachting.com.
Warning
The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that of the receiver
Consult the dealer or an experienced technician for help
Page 5
StructureScan LSS-1 Installation manual | 3
Contents
Introduction .................................................. 4
Parts included in package ...............................4
Required tools and supplies ............................5
LSS-1 Indicator lights ....................................5
Installation and wiring .................................. 6
Selecting mounting location ...........................6
Mounting the LSS-1 module ............................7
Wiring .........................................................7
Connecting the LSS-1 to your display .......7
Connecting the transducer .....................7
Power connection ..................................8
Specications .............................................. 10
Spare parts and accessories ........................ 11
Spare parts ........................................ 11
Assessories ........................................ 11
Drawings ..................................................... 12
LSS-1 dimensions ....................................... 12
Page 6
Introduction
This document describes how to install the StructureScan™ LSS-1 and connect the unit to transducers and display units.
Separate installation instruction for transducers are included with the transducer package.
Parts included in package
For spare parts and part numbers, see Parts list page
11.
Item No. Description.
1 LSS-1 Black box module
1 4 pin power cable
1 Fuse, 3A Automotive Type
1 Fuse holder
2 Yellow Ethernet caps
1 Close end crimp connector
4 Phillips stainless steal screws (#8)
1 Warranty
1 This manual
4 | StructureScan LSS-1 Installation manual
Page 7
Required tools and supplies
LINK/ACT
1 2 3
SONAR
POWER
2 mm
Drill
(5/64”) Drill Bit
Phillips screw
driver Pencil
LSS-1 Indicator lights
IND. STAT US DESCRIPTION
No Ethernet communication (cable unplugged, bad cable or remote unit not powered)
Ethernet communication is
working (link /active light)
Transducer not connected or
cable/transducer is broken
Transducer detected/locked on to
bottom
Transducer detected/not locked
on to bottom
No power or not switched on (check yellow wire)
Product in factory mode; Ethernet communication working
Product in factory mode; no Ethernet communication (cable unplugged or bad cable)
1, 2 and 3
Sonar
Power
Off
Flashing - yellow
Off
On - Green
Flashing ­green
Off
On - Red System booting
On - Green System operating
Slow ashing
- Red/green
Fast ashing ­Red/gree n
StructureScan LSS-1 Installation manual | 5
Page 8
Installation and wiring
X
X
Electromagnetic interference Gasoline fumes Vibration Heat
Sunlight Salt spray Physical damage
2.0 m (6.5 ft) Min
1.8 m (6 ft) Min
1.5 m (5 ft) Min
RADAR
Radio or AIS Transmitter
Compass
The LSS-1 connects between the transducer and display unit, or via a network switch.
Before installing the LSS-1, consider location and cable runs necessary to connect the module to the display unit and power source.
Do not run the transducer cabling near the LSS-1 DC power cables or any VHF antenna coax or power cables for the VHF.
The LSS-1 conforms to the appropriate Electromagnetic Compatibility (EMC) standards; but proper installation is required to get the best use and per formance from this product.
Selecting mounting location
When installing the module certain factors that could affect its operation should be considered. Ensure you have as much separation as possible between different electrical equipment, (see diagram).
6 | StructureScan LSS-1 Installation manual
Make sure the transducer cable is long enough to connect to the LSS-1. If not, an extension cable is available. For transducer cable length see Spare parts and accessories, page 11.
Page 9
Mounting the LSS-1 module
Preferably mount the LSS-1 module on a vertical surface so that cables exit sideways. If that is not feasable, create drip loops to prevent moisture entering the connectors.
Fasten the LSS-1 by using the screws included with the unit.
Secure cables and ensure to not put strain in the connectors.
Wiring
Refer to the Wiring diagram on page 9.
Removing the transducer cable from the LSS-1 while the module is powered on can cause sparks. Remove the transducer cable only after the module has been disconnected from its power source.
Connecting the LSS-1 to your display
The LSS-1 connects to your display over an Ethernet network, either directly or via an Ethernet network switch.
Connecting the transducer
The StructureScan transducer connects to the LSS-1 with the cable supplied with the transducer.
StructureScan LSS-1 Installation manual | 7
Page 10
8 | StructureScan LSS-1 Installation manual
On boats with large dead rise angle two
124
3
Red
Fuse
Black
NSE
Power
Control
bus
Black
BA
Yellow
Red
Yellow
Switch
Blue
(no connect)
Blue
(no connect)
12 V DC
12 V DC
+
_
+
_
LTWLTW
LTW
StructureScan transducers can be used. They are connected to the LSS-1 by using the optional Y cable.
Connect the transducers according to the labeling on the Y-cable.
Power connection
The unit will turn on when power is applied.
It is recommended to connect the LSS-1 to NSE Power control bus (A), and set NSE to power control master.
Alternatively the unit can be powered directly from the vessel’s battery (B).
Pin Color Signal
1 Black 12 V batter y -
2 Blue NC
3 Red 12V batter y +
4 Yel low Ignition sense
Page 11
StructureScan LSS-1 Installation manual | 9
If the LSS-1 is connected directly to the vessel’s battery,
A
A
B
B
B
orC
PWR
LTWLTW
LTW
LTW
LTW
LTW
the module will continue to draw power even when it is not in operation. It is recommended that the yellow
power cable wire be tted with an optional on/off switch,
allowing the LSS-1 to be powered off when not in use.
Reference Description
For part numbers, see Spare parts and assessories on page 11.
A Ethernet cable
B StructureScan Transducer cable
C StructureScan Y-cable (option)
Page 12
Specications
Mechanical
Dimensions: .................................................. See page 12
Weight: ..................................................... 0.8 kg (1.8lbs)
Material: ................................................ Plastic/Aluminum
Environmental
Operating temperature: ............... -15° - +55°C (5° - 131°F)
Storage temperature: ...............-40° - +85°C (-40° - 185°F)
Waterproof integrity .................................................. IPx7
Notified compliance ..........................CE, FCC, C-Tick, RoHS
Electrical
Power supply: ....................................................... 12V DC
Voltage input: ...............................................10 - 17 V DC
Fuse: ..................External: 3A Fast Acting Automotive Blade
Transmit power: .......................................... WRMS: 500W
WPK: 4000W
Current drain: ................................................Max: 0.75 A
Typical: 0.60 A
Inrush: 4.7 A pk
Communication
Ethernet: ............................................................. 3 ports
Shared device support: ..................................................3
Transducer
Number of devices support: ............................................1
Fre quencies: ...................................... 455kHz and 800kHz
10 | StructureScan LSS-1 Installation manual
Page 13
Spare parts and accessories
LTW
LTW
LTW
LTW
LTW
Spare parts
Item Part no. Description.
000-10238-001 Simrad LSS-1 module
032-0055-08 4 pin power cable
Assessories
Item Part no. Description.
000-00099-003
LSS-1 Thru-hull transducer,
including 9 m (30 ft) cable
LSS-1 Skimmer mount
000-00099-007
transducer, including 6 m
(20 ft) cable
000-00099-006
000-10202-001
Transducer Extension cable, 3 m (10 f t)
StructureScan Y-cable,
0.3 m (11.8”)
000- 0127-51 Ethernet cable, 1.8 m (6 ft)
000-0127-29 Ethernet cable, 4.6 m (15 ft)
000-0127-30 Ethernet cable, 7.6 m (25 f t)
000-0127-37 Ethernet cable, 15.2 m (50 ft)
000-0124-70
StructureScan LSS-1 Installation manual | 11
Kit of 4 replacement caps for
connectors
Page 14
Drawings
178 mm (7.0”)
188 mm (7.4”)
191 mm (7.5”)
210 mm
(8.26”)
58 mm (2.27”)
ø 4.7 mm
(0.185”)
200 mm
(7.87”)
LSS-1 dimensions
12 | StructureScan LSS-1 Installation manual