Simer Pumps MOD P3010 User Manual

Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-800-468-7867
English . . . . . . . . . . . . . . Pages 2-4
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le
1 (800) 468-7867
Français . . . . . . . . . . . . Pages 5-7
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 1-800-468-7867
Español . . . . . . . . . . .Paginas 8-10
©2002 PRINTED IN U.S.A. SIM565 (Rev. 7/18/02)
OWNER’S MANUAL
12V DC Powered Submersible Utility Pump
NOTICE D’UTILISATION
Pompe utilitaire submersible fonctionnant sur le courant continu de 12 volts
MANUAL DEL USUARIO
Bomba sumergible de uso general con alimentación de corriente continua de 12 voltios
MOD. P3010
293 Wright St., Delavan, WI 53115
Phone: 1-800-468-7867
1-800-546-7867
Fax: 1-800-390-5351 Web Site: http://www.simerpump.com
®
®
Safety 2
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which
are important but not related to hazards.
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition. Replace missing or damaged safety labels.
GENERAL SAFETY INFORMATION
1. This equipment is only for use with an automotive,
tractor or marine type battery fully charged to 12 Volts DC.
To reduced the risk of electric shock,
disconnect wiring before servicing. Do not lift the
pump by the power cord.
2. Know the pump application, limitations, and poten­tial hazards.
3. Do not use in water where fish are present to avoid
obstructing the intake.
4. Before Servicing: Disconnect the cables from the battery. Release all pressure within the system. Drain all water from the system.
5. Secure the discharge line before starting the pump. An unsecured discharge line can whip, possibly caus­ing personal injury and/or property damage.
6. Check the discharge hose before each use, making certain all connections are secure, and that the hose is not kinked.
7. Periodically inspect the pump and system compo­nents. Keep free of debris and foreign objects.
8. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed.
9. Personal Safety: a. Wear safety glasses at all times when working
with the pump.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work
area.
d. Make the workshop child-proof – with padlocks,
master switches, and by removing starter keys.
10.Protect the electrical cord from sharp objects, hot sur­faces, oil, and chemicals. Avoid kinking the wires. Replace or repair damaged or worn cords immediately.
11. Do not touch an operating motor. Motors can operate at high temperatures.
SIMER warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below. Your origi­nal receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water system tank shall prove to be defective, it shall be repaired or replaced at SIMER’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of SIMER, have been subject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, operational fail­ures caused by corrosion, rust or other foreign materials in the system, or oper­ation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec­tive product to the Retail outlet or to SIMER as soon as possible after the dis­covery of any alleged defect. SIMER will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive rem­edy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse­quential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Simer Limited Warranty
SIMER • 293 Wright St. • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Installation / Operation 3
DESCRIPTION
This non-corrosive pump pumps up to 1380 GPH, pumps floors dry to 3/16”, fits inside a 6” opening, and weighs only 9 pounds. Includes a 1-1/4” garden hose adapter and 10’ replaceable DC cable leads.
Fire and Explosion Hazard. Do not use in
explosive atmospheres. Use only in a vented atmos­phere. Protect the motor from explosive fumes. Pump water only with this pump.
NOTICE: Do not use a battery charger to power this pump.
For more information, see your retailer, or call Simer customer service at 1-800-468-7867.
SPECIFICATIONS
Liquid Temp. Range ........... 35° to 120° F (1.7° to 50° C)
Circuit Requirement ...................................12 Volts DC
NOTICE: Pump water only with this pump. Never run the pump dry!
PERFORMANCE
INSTALLATION
1. Power Supply: Pump must be used only with a 12 Volt DC battery, or a direct current power supply. Do not connect to 120VAC.
2. Place the pump in the water on a hard surface.
3. Install a check valve between the pump discharge port and the discharge hose adapter to prevent back­ward flow through the pump when the pump shuts off. See Figure 1.
4. Connect the discharge hose.
NOTICE: Do not allow the pump to sit in dirt or sand. This will cause rapid wear of the pump.
5. Be sure the discharge line is open.
6. Connect the motor lead wires as indicated in Table I and as shown in Figure 2.
NOTICE: One of two cordsets is supplied with the pump. To determine which wire is negative and which is positive, refer to the wire labels. Fuse in on the positive wire. Wire color does not matter.
In order for the pump to run in the proper direction and prevent harm to the pump, the wires must be connected correctly.
GPM (LPM) AT TOTAL FEET (M)
Model 0 5 10 15 20 25 30
No. (0) (1.5m) (3m) (4.6m) (6.1m) (7.6m) (9.1m)
CAPACITY GALLONS(L)/Minute
23 20 18 14 10 6 1
P3010
(87) (76) (68) (53) (38) (23) (3.8)
Figure 1 – Discharge assembly.
Figure 2 – Wiring Connections.
Connect the ... To the ...
1. Connector with Positive (+) battery terminal positive (+) wire
2. Connector with Negative (-) battery terminal negative (-) wire
TABLE I – WIRING CONNECTIONS
Performance depends on state of battery.
1-1/4" Discharge Hose Adapter
Check Valve (Sold Separately)
Discharge Por t
Cord connector, wiring, and handle are removed for clarity.
Motor Lead Wires
®
Connect the negative wire to the negative battery terminal.
Connect the positive wire, with the fuse, to the positive battery terminal.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Operation / Repair Parts 4
OPERATION
Risk of electric shock. Before attempting to check why a unit has stopped operating, disconnect the battery from the unit. Do not handle a pump or pump
motor with wet hands or when standing on wet or damp surface, or in water. Do not use this pump in marine
applications.
1. The shaft seal depends on water for lubrication. Do
not operate the pump unless it is pumping water. The seal will be damaged if the pump is allowed to run dry. Pump water only.
2. The pump motor must be connected to a fully
charged automotive, tractor or marine type battery of the proper voltage, or a direct current, full wave recti­fying 12 Volt power supply with a filter, to smooth out any current surges.
3. Do not use a battery charger to power this pump.
BATTERY OPERATION
Fire or Explosion Hazard. Follow the bat­tery manufacturer’s recommendations for the mainte­nance and safe use of the battery. The battery can cause
a fire if the battery terminals are short circuited. Never allow the DC terminals to touch each other. Take special care NOT to touch the battery cable clamps together or to drop a tool (wrench) across the terminals. This will “short circuit” the battery.
• Keep sparks and flames away from the battery.
• Use the battery in a cool, dry, well ventilated area.
• Do not allow children to play around the battery.
Severe Burn Hazard. Battery acid is corro­sive and can cause severe burns and blindness. Do not
spill on skin or clothing. Always wear eye, skin and hand protection when working with the battery.
Key Part No. Description Qty. P3010
1 Hose Adapter, 1-1/4” 1 007-022 2 Screws, Handle 2 670-646 3 Handle 1 383-147-B 4 Pump Cover* 1 230-375-B 5 Gasket, Volute 1 345-031 6Volute 1 847-002 7 Screws, Volute 9 670-784 8 Pump Screen 1 667-013
9 Screws, Screen 3 670-646 10 Replacement Fuse 1 344-001 11 Power Cord 1 992-697
REPAIR PARTS LIST
* If the motor fails, replace the pump.
10
11
1
2
3
®
4
5
6
7
8
9
Loading...