293 Wright St., Delavan, WI 53115
Phone:
1-800-468-7867
Fax:
1-800-390-5351
E-Mail:
flotec@flotecpump.com
Web Site:
http://www.flotecwater.com
OWNER’S MANUAL
Mini-Vac
®
NOTICE D’UTILISATION
Mini-Vac
®
MANUAL DEL USUARIO
Mini-Vac
®
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 1-800-468-7867
English ...................... Pages 2-6
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 468-7867
Français ................. Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-468-7867
Español ...............Paginas 12-16
SIM782 (Rev. 6/7/05)
4947 04
4835 0205
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Safety 2
SAFETY INFORMATION
Use this pump only on a 115
volt circuit. Pump is equipped
with an approved 3-conductor cord and 3-prong, grounding-type
plug. To reduce the risk of electric shock,
connect it to a properly grounded,
grounding-type receptacle.
If circuit has a 2-prong receptacle, replace
it with a properly grounded 3-prong receptacle installed in accordance with the
National Electrical Code and local codes
and ordinances.
Any extension cord used must be outdoor
grade, gauge 16 AWG or heavier, and not
more than 25’ long.
Risk of fire or explosion if
used to pump flammable liquids or if used
in explosive atmospheres. Pump water
only with this pump. Pump is designed
to pump water at temperatures between
32°-77° F (0°-25° C) only.
Risk of electrical shock. Do
not allow the motor to get wet!
Risk of burns. During nor-
mal operation, motor case may heat
enough to burn you. Do not touch motor
when it is hot.
Do not operate the pump continuously at a
discharge pressure of more than 12 psi
(83 kPa) or discharge lift of more than
28’ (8.5 M), as the motor will exceed the
normal safe operating temperature and
may heat to 180° - 190° F (82° C - 88° C).
NOTICE: This unit is not designed for applications involving salt water or brine! Use
with salt water or brine will void warranty.
SIMER warrants to the original consumer purchaser
(“Purchaser”) of its products that they are free from defects in
material or workmanship.
If within twelve (12) months from the date of the original
consumer purchase any such product shall prove to be
defective, it shall be repaired or replaced at SIMER’s option,
subject to the terms and conditions set forth below. Your original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Ninety (90) Day Warranty:
If within ninety (90) days from original consumer purchase
any Drill Pump or MiniVac Pump shall prove to be defective,
it shall be replaced, subject to the terms set forth below.
Two (2) Year Warranty:
If within two (2) years from original consumer purchase, any
1/3 HP Submersible Sump Pump, or Models 2330, 2300 or
A5500, shall prove to be defective, it shall be repaired or
replaced at SIMER’s option, subject to the terms and conditions set forth below.
Three (3) Year Warranty:
If within three (3) years from original consumer purchase any
4” Submersible Well Pump, 1/2 HP Submersible Sump
Pump, or Booster Pump Model 3075SS shall prove to be
defective, it shall be repaired or replaced at SIMER’s option,
subject to the terms and conditions set forth below.
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any
Pre-Charge water system tank shall prove to be defective, it
shall be repaired or replaced at SIMER’s option, subject to
the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to
replace product covered by this warranty. This warranty shall
not apply to acts of God, nor shall it apply to products which,
in the sole judgement of SIMER, have been subject to negligence, abuse, accident, misapplication, tampering, alteration;
nor due to improper installation, operation, maintenance or
storage; nor to other than normal application, use or service,
including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by
returning the defective product to the Retail outlet or to SIMER
as soon as possible after the discovery of any alleged defect.
SIMER will subsequently take corrective action as promptly as
reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the
term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND
BEYOND THE DURATION OF THE APPLICABLE EXPRESS
WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific
legal rights and you may also have other rights which vary
from state to state.
Simer Limited Warranty
SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351
EMail: info@simerpumps.com • Web: http://www.simerpumps.com
Hazardous
voltage
Installation 3
For parts or assistance, call Simer Customer Service at 1-800-468-7867
OIL THE PUMP
Oil the pump with 1/2 tablespoon food
grade mineral or vegetable oil with each
use. Pour the oil in the ‘IN’ port. Three 1/2
tablespoon oil packets are included.
NOTICE: The pump depends on the liquid
being pumped for lubrication.
DO NOT RUN THE PUMP DRY!
If the pump does not start to move water in
30 seconds or less, recheck the installation
and plumbing.
Mount the pump solidly on a stable
platform.
USE 1/2" HOSE (OR LARGER)
Use a reinforced hose on the inlet. The
pump should be less than 10’ above and
less than 25’ to one side of the water
source. Make the outlet hose as short as
possible – 25’ or less.
Check the washer in the inlet fitting to
make sure it is airtight. If this joint leaks
air, the pump will not operate.
Oil
Do Not Run Pump Dry!
IN
IN
Water OUT
1/2" or Larger
Outlet Hose
OUT
Water IN
1/2" or Larger
Reinforced
IN
Inlet Hose
4837A 0205
Installation 4
For parts or assistance, call Simer Customer Service at 1-800-468-7867
KEEP THE HOSES AS STRAIGHT
AS POSSIBLE
To reduce friction, do not coil or kink the
hoses. When pumping from a well or
stream, raise the inlet hose a few inches off
the bottom to avoid sucking in sand, silt or
pebbles (which can disable the impeller).
Install a strainer or the Pud-L-Scoop
TM
(included only with Model M40P-04) to
protect the pump from large solids.
NOTICE: Attach the Pud-L-Scoop
TM
to the
end of the inlet line and place it in at least
1/2" of water at the lowest point to be
pumped. Be sure all connections are air tight.
INLET HOSE GOES IN THE
WATER; OUTLET HOSE STAYS
OUT OF THE WATER. MOTOR
MUST STAY DRY
Make sure all inlet connections are tight
(no air leaks) and the inlet hose is in the
water. Make sure the end of the outlet hose
is
not
under water. If the outlet is under
water, the pump may not work.
Plug the cord into a 3-wire, 115 volt,
60 Hz, grounded A.C. outlet.
You should get water in 30 seconds or less.
If not, add more oil and repeat the process.
If your pump does not prime on the second try, check the impeller and the inside
of the pump head for wear. Replace as
needed.
In rare cases you may need to prime the
pump. To prime it, fill the suction hose
with water, put it back in the water source,
and start the pump.
The motor must have air circulation
around it for proper cooling. This pump
will lift water 12’; trying to lift water more
than 12’ can cause the motor to run hot.
The motor has a thermal overload which
will stop it if it gets too hot. If the motor
stops, allow it to cool for 30 minutes
before trying to start it again.
Straight
Hose!
No kinks!
No Coils!
Outlet Hose
Water OUT
NOTE: If you don’t get water in
30 seconds or less, add more oil
and repeat the process.
See Step 1.
Plug in pump to start it.
Water IN
Inlet Hose
IN
Installation 5
For parts or assistance, call Simer Customer Service at 1-800-468-7867
UNPLUG THE PUMP
Unplug the pump before all the water is
completely gone.
DO NOT RUN PUMP DRY!
PERFORMANCE
The pump will deliver 350 gallons/1325
liters per hour with an unrestricted discharge line. If the discharge line is restricted or raised and the pressure on the pump
outlet port increases, it will pump less
water.
NOTICE: This pump’s motor has brushes.
Inspect the brushes frequently; replace
them if they’re worn.
5
SYMPTOM PROBABLE CAUSE(S) CORRECTIVE ACTION
Pump stops without Pump has overheated Wait for overload to reset; pump will automatically
warning and thermal overload restart
has tripped
Discharge hose too long Use shorter hose or reduce lift
or discharge lift higher
than 28’
Pump Won’t Prime Pump body not oiled Add oil through inlet port (see Page 3)
Suction hose too long or Use 1/2
" Suction hose, 25’ long or less
too small (the shorter the hose, the better)
Worn impeller Replace impeller
Suction leaks Replace hose washer, check for leaks in hose
Suction hose kinked Straighten out suction hose
or coiled
Pump leaks Shaft U-cup seal leaks Replace shaft seal
Cover O-Ring leaks Replace cover O-Ring
Pump runs, pumps Worn impeller Replace impeller
little or no water
Bad motor brushes Replace motor brushes
Bad U-cup shaft seal Replace shaft seal
(pump will leak)
Suction or discharge hose Straighten out hose
kinked or coiled
TROUBLESHOOTING CHART
Unplug