Simer Pumps 2115 User Manual

OWNER’S MANUAL
Submersible Electronic Pool Cover Pump
NOTICE D’UTILISATION
Pompe submersible électronique pour couverture de piscine
MANUAL DEL USUARIO
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-800-468-7867
English . . . . . . . . . . . . . . . Pages 2-5
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le
1 (800) 468-7867
Français . . . . . . . . . . . . . Pages 6-9
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 1-800-468-7867
Español . . . . . . . . . . .Paginas 10-13
©2007 SIM822 (Rev. 12/10/07)
MODEL 2115
293 Wright St., Delavan, WI 53115
Phone:
1-800-468-7867 1-800-546-7867
Fax:
1-800-390-5351
Safety / Installation 2
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
GENERAL SAFETY
The pump motor is equipped with an automati-
cally resetting thermal protector and may restart unexpectedly.
DO NOT plug in the pump while standing in water or on a wet or damp surface.
DO NOT use in water where fish are present (oil in motor can kill fish).
DO NOT pick up the pump by the power cord. Protect the electrical cord from sharp objects, hot surfaces, oil,
and chemicals. Avoid kinking the cord. Unplug the pump before servicing it or attempting to clean it. Secure the discharge hose before starting the pump. An unse-
cured discharge hose may whip, which can cause personal injury and property damage.
Keep the pump, base, and inlet screen free of debris and for­eign objects.
SPECIFICATIONS
Power supply required..........................................115V, 60 HZ.
Liquid Temp. Range........................................Max. 77°F (25°C)
Operation Position.........................................................Vertical
Individual Branch Circuit Required ..............................15 Amp
Operating Depth Beginning min...............................3/4"
(water level) Ending max...................................1/4"
Discharge.........................................................1" NPT (25 mm)
DESCRIPTION
The submersible pump is designed for water removal from pool covers in home swimming pool applications. Unit is construct­ed of hi-impact corrosion resistant plastic. Screened inlet and base prevent large solids from entering pump and protect pool cover.
NOTICE: This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.
PERFORMANCE
INSTALLATION
Hazardous voltage. Can shock, burn or cause
death. Do not use power cord to lift motor. Always use handle.
1. Pump should always stand upright on base when operating. Do not suspend pump by means of discharge hose or power cord. Keep pump inlet screen clear.
2. To install a garden hose, first install adapter provided with pump.
NOTICE: To keep friction as low as possible, hose must be 5/8" or larger. Keep hose as short as possible.
3. If, in your application, backflow is a problem when the pump stops, prevent it by installing a 1” NPT check valve in the pump discharge.
4. Power Supply: Pump is designed for 115V., 60 HZ. operation and requires an individual branch circuit of 15 amperes or more capacity. It is supplied with a 3-wire cord set with grounding-type, GFCI protected plug for use in a 3-wire, grounded outlet. For safety, pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway or ground wire system. Do not cut off the round grounding prong.
Risk of sudden starts. Can result in an elec-
trical shock or the pinching of hands or tools. The pump
motor is equipped with automatic resetting thermal protec­tor and may restart unexpectedly. Protector tripping is indi­cation of motor overloading as a result of operating pump at high pressure, excessively high or low voltage, inade­quate wiring, incorrect motor connections, or a defective motor or pump.
GPH (LPH) AT TOTAL FEET (M)
3' 5' 10' 15' 18' 20' 22'
(0.91) (1.52) (3.05) (4.57) (5.49) (6.09) (6.70)
1600 gal 1524 gal 1260 gal 924 gal 648 gal 372 gal 0 gal (6 057 L) (5 769 L) (4 770 L) (3 498 L) (2 453 L) (1 408 L) (0 L)
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.
Risk of Electric Shock. Connect only
to a properly-grounded, grounding type receptacle. The pump requires 115 volt, single phase current. The pump is protected by a ground-fault circuit interrupter (GFCI) built into the plug. Do not modify the cord, plug, or GFCI.
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
To reduce the risk of electric shock,
replace damaged cord immediately.
To reduce the risk of electric shock, do
not use an extension cord to connect the unit to the electrical supply; provide a properly located outlet.
SAVE THESE INSTRUCTIONS
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
Operation 3
OPERATION
Risk of electrical shock. Can burn or cause
death. Do not handle pump or pump motor with wet hands or
when standing on wet or damp surface, or in water. Disconnect power from pump before handling, servicing, or attempting to repair pump.
NOTE: The power cord for this pump is equipped with a Ground Fault Circuit Interrupter (GFCI). The GFCI will shut down the pump in the event of leakage of electrical current from the pump motor or cord to ground. If the pump does not respond when plugged in, unplug it, reset the GFCI (push the RESET button on the plug) and plug it in again. If it still doesn’t respond, make sure that the circuit breaker for the branch cir­cuit is in the ‘on’ position (closed). if the circuit breaker is closed and the pump doesn’t respond, consult a licensed elec­trician. DO NOT TRY TO MODIFY the cord or plug, and do not remove the GFCI.
The Electronic Pool Cover Pump is fully automatic in operation. The “smart” controller starts the pump every 2-1/2 minutes and causes it to run for 5 seconds. If it senses that there is no water to the pump, it stops. If it senses water, it continues to run until the water is pumped down to 1/4" deep, and then it stops. It then goes into a 7-minute quick-detection cycle, starting 4 times the first minute, twice the second minute, and once a minute for the next 5 minutes. If by the last check it has not detected water, it resumes its cycle (run­ning 5 seconds every 2-1/2 minutes) until it senses water again.
NOTICE: When you plug the pump into the outlet, it will start and run for 5 seconds. It will then cycle as described above.
If the unit is put in the water and started, interrupting the water flow into the pump during the 5-second water-sensing run will cause it to wait 2-1/2 minutes before restarting.
1. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the overload protector will stop the motor before it is dam­aged. When the motor has cooled sufficiently, the overload protector will reset itself and the motor will restart.
NOTICE: If the overload protector stops the pump repeated­ly, disconnect the power from the pump and check it to find the problem. Low voltage, clogged impeller, too much back pressure in the discharge hose (as when pumping through 50’ (15 M) of coiled hose), or extended running of pump with no load, can all cause overheating.
2. The water being pumped cools the motor, allowing the pump to run continuously at any depth of water above 1/4". However, if the motor overload stops the pump, allow it to cool for one hour before restarting. The motor will not restart before the overload has cooled.
LOCKED ROTOR
1. If the pump tries to start and senses that the rotor is locked, it will shut off, wait 2-1/2 minutes, and try to restart.
2. If the rotor has unlocked, the pump will resume normal operation. If the rotor is still locked, the pump will shut off again and wait through another 2-1/2 minute cycle.
3. After 2-1/2 minutes, the pump will again try to start. If the rotor has unlocked, the pump will resume normal opera­tion. If the rotor is still locked, the pump will shut off and will not restart automatically.
4. To restart the pump manually, unplug it and plug it in again.
5. If the rotor is still locked, UNPLUG THE PUMP, remove the base, shield, and screen, and clean out the rotor.
Risk of dangerous or fatal electrical shock.
Disconnect the pump from the power source before disassembling the pump or cleaning out the rotor.
6. See Page 4 for important information about the alignment of the screen and shield when you reassemble them. Note that the pump will not operate correctly if these parts are not correctly installed.
7. Once you have reassembled the pump, reset it on the pool cover and plug it in again to resume normal operation.
AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock will cause the pump to overheat and fail. This pump has an anti-airlock hole in the bottom of the pump body. If you suspect an airlock, unplug the pump, clean out the anti-airlock hole with a paper clip or piece of wire, and restart the pump.
NOTICE: If the outlet of the discharge hose is submerged you must have a 1/8" hole in the discharge hose to prevent airlock. This hole must be open to air.
NOTICE: If you move the pump or the pump airlocks, be sure to drain the hose before trying to restart the pump.
Repair Parts / Troubleshooting 4
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
TROUBLESHOOTING
Risk of electrical shock and sudden start.
Disconnect electrical power to pump before attempting to troubleshoot or work on it.
REPAIR PARTS
k
3rd
Anti-Airlock Hole
Tighten 1st
Orient Part Number with Anti-Airlock Hole as shown
2nd
Insert Screws through base. (Base omitted for clarity)
Key Part Description Qty. Part No.
1 Base 1 PS70-83 2 Screen 1 PS8-6P 3 Shield 1 PS70-3P 4 Impeller 1 PS5-25P 5 Motor 1 ** 6 90° Garden Hose Adapter 1 PS74-78 7 Power Cord 1 PS17-1505
NOTICE: To purchase a check valve, call Customer Service at 1-800-365-6832 and order part number PW73-63.
** If motor fails, replace entire pump.
• Not Illustrated.
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Pump won’t Blown fuse If blown, replace with fuse of proper size start or run
Low line voltage If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company. Defective motor Replace pump Impeller Remove base and screen, locate source of binding
Pump operates Low line voltage Call power company but delivers little or no water
Something caught in impeller Clean out impeller Small diameter garden hose Use larger diameter garden hose or 1" flexible pipe. Eliminate any
or long discharge line excess hose. Short hoses work best Check valve installed without Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump
vent hole discharge & check valve Air lock Turn off pump for a few seconds, clean out anti-airlock hole and restart pump Coils or bends in hose Straighten hose
Assemble Screen and Shield as shown.
7
6
5
Anti-Airloc
4
Hole
3
2
1
5635 0607
Warranty 5
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.
SIMER warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in material or workmanship. If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or
replaced at SIMER’s option, subject to the terms and conditions set forth below.Your original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Product/Model No. Warranty Period
M40P, M40, BW85P, CM10, CMK 90 days
2330, 2300, 2310, 2955, 2956, 2957, 2960, A5500 2 Years
4" Submersible Well Pumps, 3984, 3983, 2975PC, 2958, 2985, 3075SS 3 Years
Pre-Charge Water System Tank, 3986, 3985, 2956 5 Years
3988, 3995, 3997, 3963 Lifetime
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of SIMER, have been subject to negligence, abuse, accident, misap­plication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to SIMER as soon as possi­ble after the discovery of any alleged defect. SIMER will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole o
bligation and purchaser’s exclusive remedy for defective products. SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR­POSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867/1-800-546-7867 • Fax: 1-800-390-5351
E-Mail: info@simerpumps.com • Web Site: http://www.simerpumps.com
Loading...
+ 11 hidden pages