Silex technology SX-3700WB User Manual

Users Manual SX2
2. PRICOM SX-3700WB
This product is a wireless USB device server that will serve USB type peripheral equipment (a printer, scanner etc.). By using the bundled PRICOM Monitor SX, it is possible to view the state of the connected printer via a network. In addition it is possible, by using the bundled PRICOM USB Utility, to share a scanner as a network scanner.
TIP
NOTE
function.
- Only one USB device can be connected at a time. The USB device must be connected directly to this product
- Refer to our web page ( http://www.silex.jp/ ) for the most up to date information.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EN55022 Class-B EN55024
PRICOM SX-3700WB
2-1
Users Manual SX2

Environment

The following are needed for this product.
The followings are objects that connect to the network.
- PC with wireless communication
- USB Cable (A-B Type Connectors)
- Printer, Scanner etc.
Supported OS
Windows 98/98SE/Me, Windows 2000, Windows XP, Windows Server 2003, UNIX/Linux, Macintosh (Mac OS 8.6 - Mac OSX Ver10.2 or newer)
Operating Environment
- Temperature: +10 C +35 C
- Humidity: 20% to 80%RH (no dewing)
Storage Environment
- Temperature: -10C to 50C
- Humidity: 20% to 90%RH (no dewing)
Electric current
5V +- 5% 1.0A
EMI
VCCI Class-B FCC Class-B EN55022 Class-B EN55024
PRICOM SX-3700WB
2-2
Users Manual SX2

Equipment explanation

Part name and function

Top
Infra LED (Green)
Front Side
Link LED (Green)
Status LED (Orange)
Bottom
Status LED (Orange)Ethernet Address (The last 6 digits are the product serial number)
Right Side
Power connector
Push Switch
<Top/Front Side> The LEDs have the following meaning: Infra LED (Green)
Lights when an Infra. mode network connection is established.
Link LED (Green)
Lights when an OldAdHoc mode network connection is flashed. Lights when an AdHoc mode network connection is established. Lights when an Infra. mode network connection is established.
Status LED (Orange)
Flashes during data transfer.
PRICOM SX-3700WB
USB Port
2-3
Users Manual SX2
<Bottom> Ethernet Address
The Ethernet (MAC) Address of the device is found on the bottom. The last 6 digits are the product’s serial number.
- If the Ethernet Address is 00:80:92:18:0E:1A (noted as 008092180E1A) then the
NOTE
<Right Side> USB Port
Power Connector
<Front Side> Push Switch
product’s serial number is 180E1A.
Connect a USB Cable (A Type connector)
Connect AC adapter
By pushing the push switch, the server can be restored to factory-default settings or do a self-diagnosis and print the configuration settings. It can also be used to put this product into infrastructure mode.
<Restore Factory default>
1. Please verify that AC adapter is not connected to this product.
2. While pushing the push switch, connect the AC adapter to the power supply connector of this product. Shortly after a power is supplied, all of the Light Emitting Diodes will light and then some will turn off.
3. Continuing pushing (about 5 seconds) — when the restoration starts all of the Light Emitting Diodes will light. When the status LED lights, release the push switch.
Push Switch
Link LED
- Do not turn off the power to this product while it is initializing to factory default.
TIP
- When this product is turned on again after factory default is completed, do not push the pushbutton switch.
PRICOM SX-3700WB
2-4
Users Manual SX2
<Put into infrastructure mode>
1. Please verify that AC adapter is connected and that this product has started normally.
Push Switch
2. Push and hold the push switch down. Continue to hold down the push switch for about 5 seconds. The lights will blink and then the infrastructure LED will light. It is now in infrastructure mode.
- When using Infrastructure during the initial setup, disable WEP on the access point.
TIP
<Self diagnostic/ Configuration Printing>
1. Verify that AC adapter is connected to this product.
2. Verify that the printer is connected and ready to print.
3. Verify that the printer is power on.
4. While holding the push switch, plug in the power supply. Status LED (Orange), Link LED (Green), InfraLED (Green) is bringing.
5. Hold the push switch (for about 30 seconds). The self test and configuration will then begin.
TIP
- If a mistake is made during the configuration, restore factory default and try again.
- Do not turn off the printer until the printing of self-test/configuration settings has finished.
- The printer must have and internal font for the self-test/configuration settings to print.
PRICOM SX-3700WB
2-5
Loading...