There are several terms and acronyms that you should become familiar with before reading this
manual. They are shown below.
Term/Acronym Definition
Crosspoint The electronic switch that assigns one of the inputs on the
matrix crosspoint modules to an output.
Chapter
1
Destination The output of a routing switcher connected to a device that
receives signals from the output of the switcher.
Output Connects the signal to the destination device.
Source The signal that is connected to the input of the routing
switcher.
Input Connected to the source that provides the signal to the
switcher.
Matrix The crosspoint array of the switcher module that selects
which input is selected to an output.
Protocol The command structure used on a serial bus to affect a
switch or multiple switches on the routing switcher.
Routing Switcher Consists of one or more crosspoint modules that switch
together, or sometimes independently, to connect the
desired signals through the switcher.
Serial Port The 9-pin RS232 connector that allow you to control the
switcher using a standard personal computer or other
external device. Sends control protocol commands in
ASCII.
1
Page 8
SIERRA VIDEO
Warnings & Safety Regulations
The information in the following section provides important warnings and safety guidelines for
both the operator and service personnel. Specific warnings and cautions may be found
throughout this manual. Please read and follow the important safety precautions noting especially
those instructions relating to risk of fire, electrical shock and injury to persons.
Any instructions in this manual that require opening the equipment cover or enclosure are
intended for use by qualified service personnel only. To reduce the risk of electrical shock, do not
perform any servicing other than what is contained in the operating instructions unless you are
qualified.
Warnings
Heed all warnings on the unit and in the operating instructions.
Disconnect AC power before installing any options.
Do not use this product in or near water.
This product is grounded through the grounding conductor of the power cord. To avoid
Route power cords and other cables so that they are not likely to be damaged, or create a
Dangerous voltages exist at several points in this product. To avoid personal injury, do not
To avoid fire hazard, use only the specified type, correct voltage, and current rating of fuse.
Have qualified personnel perform safety checks after any completed service
This is an FCC class A product. In a domestic environment, this product may cause radio
Cautions
Use the proper AC voltage to supply power to the switcher. When installing equipment, do
To prevent damage to equipment when replacing fuses, locate and correct trouble that caused
Use only the recommended interconnect cables to connect the switcher to other frames.
Follow static precautions at all times when handling the equipment.
electrical shock, plug the power cord into a properly wired receptacle before connecting
inputs and outputs.
hazard.
touch unsafe connections and components when the power is on.
Always refer fuse replacement to qualified service personnel.
interference, in which case the user may be required to take necessary measures.
not attach the power cord to building surfaces.
the fuse to blow before applying power.
2
Page 9
Cautions (continued)
Leave the side, top, and bottom of the frame clear for air convection cooling and to allow
room for cabling. Slot and openings in the frame are provided for ventilation and should not
be blocked.
Only an authorized Sierra Video technician should service the units. Any user who makes
changes or modifications to the unit without the expressed approval of the Sierra Video will
void the warranty.
Power Supply
The Sierra Video SCP series of control panel use a “wall mount” AC to DC adapter, converting
120/220VAC to 9VDC @1A. The adapter is supplied with your control panel.
EMC Regulatory Notices
Federal Communications Commission (FCC) Part 15 Information: This device complies with Part
15 of the FCC standard rules. Operation is subject to the following conditions:
This device may not cause harmful interference
SCP-132
This device must accept any interference received including interference that may cause
undesirable operations.
Delivery Damage Inspection
Carefully inspect the frame and exterior components to be sure that there has been no shipping
damage. Make sure all modules are seated correctly and have not detached during shipment.
3
Page 10
SIERRA VIDEO
Factors Affecting Quality of Results
There are many factors affecting the quality of results when signals are transmitted from a source
to a destination.
Signal cables — Use only the best quality cables to avoid interference and degraded signal
quality and elevated noise levels.
Sockets and connectors of the sources and destinations — Use only the highest qua lity, since
"zero ohm" connection resistance is the target. Connectors should also match the required
impedance (75 ohm in video) to minimize return loss.
Amplifying circuitry — Must have quality performance when the desired end result is high
linearity, low distortion, and low noise.
Distance between sources and destinations — Plays a major role in the final result. For long
distances (over 15 meters) between sources and destinations, special measures should be
taken to avoid high frequency cable losses. These measures include using higher quality
cables and/or adding line cable equalizing amplifiers.
Interference from neighboring electrical appliances — These can have an adverse affect on
signal quality. Balanced audio lines are less prone to interference, but unbalanced audio
should be installed away from any main power lines, electric motors, transmitters, etc. even
when the cables are shielded.
CAUTION!
Only an authorized Sierra Video technician can service the control panels. Any user who
makes changes or modifications to the unit without the expressed approval of the
manufacturer will void the warranty
Use the proper AC to DC adapter to supply power to the unit.
Use only the recommended interconnect cables to connect the control panel to other
frames.
4
Page 11
SCP Control Panel Family
Overview
The SCP line of control panels requires switcher software version 7.xxx or newer for
programming compatibility.
The SCP series are programmable control panels using a powerful on board microprocesso r
capable of handling a large database. This design manages serial communications with the
router and up to 64 SVS control panels (up to 99 in some router models). All buttons in the SCP
line are soft key. That is, every key can be programmed
The SCP panel is programmed using our free version of our Graphical Router Interface Program
TyLinx Pro or MediaNav software. The software lets you choose your panel, select your functions
and assign them to the buttons, store these settings in memory and/or copy the configurations to
multiple SCP panels.
SCP-132
These panels were designed to allow for maximum flexibility in the categorization of buttons. The
Shift Push is similar to the Ctrl key on the PC, which allows different functions to be performed on
the panel, such as toggling between “Alpha” and “Sort” on numerical values during a scroll
function.
The following steps should be completed before applying power to the control panel. It is very
important that the router the control panel is connected to, be correctly configured with names,
size, etc.
Chapter
2
Rack Mounting
Carefully inspect the control panel to ensure that there has been no shipping damage. Make sure
all shipping material is removed from the router frame.
The control panels described in this manual can be rack mounted in a standard 19" (RU) EIA rack
assembly and includes rack "ears" at the ends of the front of the frames. None of the control
panel models require spacing above or below the unit for ventilation.
To rack mount any of the control panels, simply place the unit's rack ears against the rack rails of
the rack, and insert proper rack screws through each of the holes in the rack ears. Always rack
mount the control panel prior to plugging the unit into a power receptacle or attaching any cables.
Dimensions
The SCP-132 control panels are 1 rack unit high, 19” wide, and 2.5” deep.
7
Page 14
SIERRA VIDEO
DIP switch settings
Your control panel has been configured at the factory for the settings you are most likely to need.
However, if you want to configure the control panel differently, you can do so by setting the
switches located on the processor board.
The SCP panels have 2 DIP switches that set the panel’s ID number, type, baud rate, and
memory settings. The panel is shipped with the factory defaults as indicated in the table below. ID
numbers are randomly set at the factory. If you need to change any values, follow the table
below.
Disconnect the panel’s power and remove the rear cover to
access the DIP switches. The table below shows the settings
available:
Note:
Control Panel
Dip Switch Settings Label (LB04152-00)
804112/804224 Select (S1-2):
804112 panel: S1-2 off
804224 panel: S1-2 on
804020 panel: S1-2 off
804132 panel S1-2 off*
Port speed (S1-6):
9,600 bps S1-6 off
31,250 bps S1-6 on *
Firmware Download (S1-7):
Normal Operation: S1-7 off *
Force Wait for Download: S1-7 on
Flash Memory Erase (S1-8):
Normal Operation: S1-8 off *
Erase Flash Memory: S1-8 on
Panel Id (S2-1 to S2-7):
Id 0 7 off 6 off 5 off 4 off 3 off 2 off 1 off
Id 1 7 off 6 off 5 off 4 off 3 off 2 off 1 on
Id 2 7 off 6 off 5 off 4 off 3 off 2 on 1 off
Id 3 7 off 6 off 5 off 4 off 3 off 2 on 1 on
Id 4 7 off 6 off 5 off 4 off 3 on 2 off 1 off
Id 5 7 off 6 off 5 off 4 off 3 on 2 off 1 on
(etc.)
Id 62 7 off 6 on 5 on 4 on 3 on 2 on 1 off
Id 63 7 off 6 on 5 on 4 on 3 on 2 on 1 on
(etc.)
Id 99 7 on 6 on 5 off 4 off 3 off 2 on 1 on
* Factory Settings
Changing any Dip Switch causes an automatic reset after a few se conds.
Each panel in a system MUST have its own unique ID number.
8
Page 15
The RS-485 Network
Once the panels DIP switch settings are compatible with the system (i.e. each panel has its own
unique ID number), the panel can be connected to the RS-485 network.
The panel has two mini XLR connectors. The mating connectors used are Switchcraft TA3F. If
these are not available locally, they can be purchased from Sierra Video. The cable entry hole
into these connectors is quite small and we have found that Belden 8451 cable fits quite well
through the strain relief.
The pinout of the connector is as follows:
Pin 1………RS-485 +
Pin 2………Ground
Pin 3………RS-485 –
The two connectors on the back of the control panel are connected in parallel. This allows the
panels to be looped (“daisy chained”) together. If it is more convenient, you can build a fanout
panel or box so that only one cable needs to run to each panel. In either case, the total cable
length cannot exceed 5,000 feet at 31,250 baud or 10,000 feet at 9,600 baud.
SCP-132
Power
9 vdc
Installation
Once the DIP switch settings have been set to your system requirements, connect the panel’s
control cable (RS-485) to the router and apply power to the panel.
Upon power up the panel will display a series messages. The first message displayed will read
“Power On Tests Successful” followed by “Starting Application Please Wait…”. The next
message displayed will read “Contacting Router, Please Wait…” on the top row. The bottom
row reads “804132” (the panel’s part number) “ID:xx” (the panel’s ID number) “Speed:xxxxx”
(panel port speed) “Sftwr: Vx.xx” (current software version).
* If the display stays on the “Contacting Router…” message, it is an indication that there is no
communication with the router. Check the RS-485 cable for correct connection.
If communication with the router is correct the panel will display the following message, “Sorting Router I/O Names… Please Wait…” at this point the panel is retrieving the input and output
names from the router’s processor.
If the router name, number of inputs or outputs is different than what is stored in the panel’s flash
memory, the message “Router Name or Size changed Erasing Flash, Resetting Panel…” is
displayed.
RS-485
Looped
Connectors
After these initial functions are complete, the panel will display its main control screen. The panel
is now ready for programming.
Note:
Each panel in a system MUST have its own unique ID number.
9
Page 16
SIERRA VIDEO
Programming
The Sierra Video TyLinx Pro or MediaNav software programs are used to setup the output(s) and level of
the control panel. Refer to the TYLINX PRO or MediaNav manual for detail on panel programming.
10
Page 17
SIERRA VIDEO
Chapter
3
Warranty
A. General
Buyer assumes all responsibility for ascertaining the suitability of Sierra Video (hereinafter "SVS")
products for Buyer's intended use. No product sold by SVS is designed or manufactured for use
in any manner or under any conditions other than those described in SVS's instruction manuals
and other printed material for each particular product. If any product is used or applied in a
manner or under conditions not specifically authorized by such written materials or if any product
is used by unqualified or improperly trained personnel, Buyer agrees that SVS shall have no
liability of any kind arising from such use, and Buyer agrees to indemnify and hold SVS harmless
from any claims of third parties arising from such use, and Buyer shall provide SVS with counsel
of SVS's choice to defend against such claims.
B. Limited Warranty
1. This limited warranty applies only to the original purchaser and is non-transferable. This limited
warranty begins on the date of purchase and will be in effect for seven (7) years for new
equipment and for three (3) years for "Factory Refurbished" equipment. Power Supplies and fans
are warranted for three (3) years from the date of purchase for new equipment and two (2) years
for “Factory Refurbished” units, from the date of purchase.
Buyer must obtain a Return Material Authorization ("RMA") number from SVS prior to returning a
product for repair. If, in SVS' sole discretion, the product is found to be defective during the term
of this warranty, SVS will at its option: (a) provide free replacement parts, and/or (b) repair the
unit at an SVS facility. During the warranty period, SVS will make every reasonable effort to
support critical emergencies by supplying no-cost loan equipment while the defective unit is being
repaired. SVS will provide replacement parts and/or factory service at no charge. Buyer bears
the cost of shipping products returned to SVS under this warranty. SVS will bear the cost of
shipping repaired products or replacement parts to the Buyer.
This limited warranty shall not apply to any of SVS's goods which have been altered or which
have been subjected to misuse, mishandling, improper storage or negligence. The
aforementioned provisions do not extend the original warranty period of any goods which have
been replaced by SVS. This limited warranty shall not apply to any goods not of SVS's
manufacture, Buyer to be entitled only to the warranty set forth in the original manufacturer's
limited warranty.
11
Page 18
SIERRA VIDEO
THIS LIMITED WARRANTY IS EXPRESSED IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS, IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE,
AND ALL OTHER OBLIGATIONS OR LIABILITIES ON SVS'S PART.
SVS neither assumes nor authorizes any other person to assume for SVS any other liabilities in
connection with the sale of products of its own manufacture.
2. SVS's liability hereunder on any claim of any kind, except as set forth herein for any loss,
injury to person or property or damage, shall in no case exceed the price allocable to the goods
which give rise to such claim.
3. In no event shall SVS be liable for any damages or injuries to person or property if any
goods do not meet the above limited warranty, including, without limitation, incidental expenses or
consequential or special damages, except as set forth in such limited warranty. The foregoing
states the exclusive remedy of Buyer and the exclusive liability of SVS for any breach of the
foregoing limited warranty.
C. Cancellation
Except as provided in paragraph B immediately above, all sales are final, and Buyer may cancel
this order or return products only upon written consent of SVS.
D. General
In the event of a breach of any of the terms hereof, the non-breaching party shall be entitled to
recover all of its costs, fees, and expenses, including, without limitation, reasonable attorney's
fees, from the breach party incurred as a result of such breach, regardless of whether or not a
suit is actually filed to enforce the terms hereof.
The provision hereof shall be governed by the laws of the State of California (excluding its choice
of law provisions).
The headings are for convenience only and do not limit or amplify the terms and provisions
hereof.
In case any one or more of the provisions set forth herein shall be held to be invalid, illegal, or
unenforceable in any respect, the validity, legality, and enforceability of the remaining provisions
contained herein shall not in any way be affected or impaired thereby.
No waiver, alteration, or modification of any of the provisions hereof shall be binding unless in
writing and signed by an authorized Officer of SVS.
NOTE:
All products returned to Sierra Video for service must have prior approval. Return
authorization requests may be obtained from your SVS dealer.
12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.