Siemens XPS,XCT Operating Instructions Manual

Ultrasonic Transducers
XPS/XCT
Operating Instructions 03/2013
This manual outlines the essential features and functions of the Echomax XPS/XCT Series transducers. This manual, and the website: www.siemens.com/processautomation Siemens Milltronics representative.
Questions about the contents of this manual can be directed to:
Siemens Milltronics Process Instruments Siemens AG 1954 Technology Drive, P.O. Box 4225 Industry Sector Peterborough, Ontario, Canada, K9J 7B1 76181 Karlsruhe Email: techpubs.smpi@siemens.com
Transducer Applictions Manual
. Printed copies are available from your local
European Authorized Representative
Deutschland
, are also available on our
Copyright Siemens Milltronics
Process Instruments 2013.
Disclaimer of Liability
All Rights Reserved
We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions.
While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement.
Technical data subject to change.
English
mmmmm
MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments
Safety Guidelines
Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are
accompanied by a clarification of the level of caution to be observed.
WARNING: relates to a caution symbol on the product, and means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage.
WARNING: means that failure to observe the necessary precautions can result in death, serious injury, and/or considerable material damage.
CAUTION: means that failure to observe the necessary precautions can result in considerable material damage.
Note: means important information about the product or that part of the operating manual.
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-1
mmmmm
Unit Repair and Excluded Liability
The user is responsible for all changes and repairs made to the device by the user or by the user’s agent.
All new components are to be provided by Siemens Milltronics Process Instruments Inc.
English
Restrict repair to faulty components only.
Do not reuse faulty components.
Page EN-2 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
Introduction
transducer
transducer face
–3 db boundary
axis of transmission, perpendicular to transducer face
This product is intended for use in industrial areas. Operation of this equipment in a residential area may cause interference to several frequency based communications
The Echomax XPS/XCT series of transducers operate with Siemens Milltronics ultrasonic level monitoring products.
The transducer converts the electrical transmit pulse from the transceiver into acoustical energy. It then converts the acoustical energy of the echo back into electrical energy for the controller.
The transducer face emits acoustical energy radiating outward, decreasing in amplitude at a rate inversely proportional to the square of the distance. Maximum power radiates perpendicularly from the transducer face on the axis of transmission. Where power is reduced by half (– 3 dB), a conical boundary centered around the axis of transmission defines the sound beam, the diameter of which is the beam angle.
.
English
mmmmm
General Guidelines
The XPS/XCT transducers have an integrated temperature sensor that reports the air temperature at the transducer to the controller.
WARNING: Materials of construction are chosen based on their chemical
compatibility (or inertness) for general purposes. For exposure to specific environments, check with chemical compatibility charts before installing.
XPS/XCT Series – Certificate SIRA 99ATEX5153X
This equipment may be used in hazardous areas associated with all gases with temperature classes T1, T2, T3 and T4 for the XPS series (XPS-10, XPS-15, XPS-30, and XPS-40) and T1, T2, and T3 for the XCT series (XCT-8 and XCT-12). The XPS series is only certified for use in ambient temperatures in the range of - 40 °C to 95 °C and the XCT series is only certified for use in ambient temperatures in the range of -40 °C to 145 °C. Neither should be used outside of their respective temperature ranges.
Installation shall be carried out in accordance with the applicable code of practice, and by suitably trained personnel.
These devices should only be supplied from a circuit containing a suitably-rated fuse that has a breaking capacity of 4000A. This fuse is included in Siemens Milltronics controllers.
Repair of this equipment shall be carried out in accordance with the applicable code of practice.
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-3
The certification of this equipment relies on the following materials used in their construction:
XPS Series XCT Series
mmmmm
English
Enclosure Kynar®1710
Kynar®710
Encapsulant Stycast LA-9823-76 Durapot® 861-F3 & 864
1.
Kynar®is a registered trademark of ELF Atochem. Durapot®is a registered trademark of Cotronics Corporation.
For manual override, use the disconnect switch provided in the building installation of the associated controller.
XPS 30/40 Series – Certificate SIRA 01ATEX5153X
This equipment may be used in hazardous dust zones with all conductive and non­conductive dusts. The XPS-30 and XPS-40 type series transducers have a maximum surface temperature of 135 °C (275 °F) (Temperature Class T4). These units are certified for use in ambient range of -40 to 95 °C (-40 to 203 °F). The transducers should not be used outside this temperature range. The XPS-30 and XPS-40 ultrasonic transducers must be installed so the face of the transducer is not substantially subjected to light.
Installation shall be carried out in accordance with the applicable code of practice, and by suitably trained personnel. Repair of the equipment shall be carried out in accordance with the applicable code of practice and installation instructions.
These devices should only be supplied from a circuit containing a suitably rated fuse that has a breaking capacity of 4000A. This fuse is included in Siemens Milltronics controllers.
The certification of this equipment relies on the following materials used in their construction:
Enclosure: Kynar®710 Encapsulant: Stycast LA-9823-76
For manual override, use the disconnect switch provided in the building installation of the associated controller.
Product Marking
Note: Kynar®polyvinylidene flouride is resistant to attack from most chemicals under the
described operating conditions. However, for exposure to specific environments, check with chemical compatibility charts prior to installation.
WARNING: This product is designated as a Pressure Accessory per Directive 97/
23/EC and is
not
intended for use as a safety device.
Page EN-4 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
XCT-8
XCT-8 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 145 °C V in: 1.77 V r.m.s.; 250 Vp Iin:44.2mAr.m.s.
Enclosure: IP66, IP68
0518
SIRA 99ATEX5153X
II2GD EExmIIT3
Siemens Milltronics Process Instruments, Peterborough
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA
- VEJA INSTRUÇÕES
KCC-REM-S49 Echomax
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
Class I, Zone 1, ExsIT4,Amb.Temp.:–40°C to 95°C
IC 3 145 DIPIP65/IP67 AEx X
Ex s I T , Amb. Temp.: –40°C to °C
NZ 08.3066
Class I, Div 2, Group A, B, C, D Class II, Div 2, Group F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
Ex mb IIC T3 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
OCP 0017
Ex mb IIC T3 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
XCT-12 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 145 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
SIRA 99ATEX5153X
II2GD EExmIIT3
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
OCP0017
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
ClassI,Zone1 ExsIT4,Amb.Temp.: 9
, DIP IP65 / 67 AEx X
–40°Cto 5°C
ExsIICT3 Amb.Temp.:–40°Cto145°C
IP
NZ 08.3066
Class I, Div 2, Group A, B, C, D Class II, Div 2, Group F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
0518
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA - VEJA INSTRUÇÕES
KCC-REM-S49 Echomax
XCT-12
English
mmmmm
Note:
Product configuration number shown for example only.
Serial number shown for example only.
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-5
mmmmm
XPS-10 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
ClassI,Zone1, ExsI/IICT4 DIP IP65 / 67 ANZEx 08.3066X
0518
SIRA 99ATEX5153X
II 2 GD EExmIIT4
KCC-REM-S49
Echomax
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA
- VEJA INSTRUÇÕES
OCP 0017
XPS-15 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40°C to 95°C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIP IP65 / 67 ANZEx 08.3066X
SIRA 99ATEX5153X
II2GD EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
0518
KCC-REM-S49
Echomax
XPS-10
English
XPS-15
Note:
Product configuration number shown for example only.
Serial number shown for example only.
Page EN-6 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
XPS-30
XPS-30 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp Iin:44.2mAr.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIP IP65 / 67 ANZEx 08.3066X
SIRA 99ATEX5153X
II 2G 1D EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
KCC-REM-S49
Echomax
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS (20 N-m)
ATENÇÃO - RISCO POTENCIAL DE CARGA
ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
XPS-40 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIPIP65/67 ANZEx 08.3066X
SIRA 99ATEX5153X
II 2G 1D EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
KCC-REM-S49
Echomax
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS (20 N-m)
ATENÇÃO - RISCO POTENCIAL DE CARGA
ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
XPS-40
English
mmmmm
Note:
Product configuration number shown for example only.
Serial number shown for example only.
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-7
Specifications
XPS-10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12
mmmmm
English
Measurement
Range
Frequency (kHz) 44 44 30 22 44 44
Beam Angle 12 6 6 6 12 6
Location
Maximum
Altitude (m)
Ambient
Temperature
Pressure
Pollution Degree
Housing
Mounting
0.3 - 10 m (1 - 33 ft)
indoor/outdoor indoor/outdoor indoor/outdoor indoor/outdoor indoor/outdoor indoor/outdoor
2000 2000 2000 2000 2000 2000
-40 to 95 C
(-40 to 203 F)
8 bar
(120 psi)
44 4444
PVDF PVDF PVDF PVDF Standard: PVDF
1" NPT or BSP conduit connection
0.3 - 15 m (1 - 50 ft)
-40 to 95 C
(-40 to 203 F)
8 bar
(120 psi)
1" NPT or BSP
conduit
connection
0.6 - 30 m
(2 - 100 ft)
Environmental
-40 to 95 C
(-40 to 203 F)
Europe: 0.5 bar
N. America: 15 psi
Construction
1-1/2" NPT or BSP
conduit
connection
0.9 - 40 m (3 -130 ft)
-40 to 95 C
(-40 to 203 F)
Europe: 0.5 bar
N. America: 15 psi
1-1/2" NPT or BSP
conduit
connection
0.6 - 8 m (2 - 26 ft)
-40 to 145 C
(-40 to 293 F)
8 bar
(120 psi)
Optional: Universal* sized flange available with PTFE
1" NPT or BSP
conduit
connection
0.6 - 12 m (2 - 40 ft)
-40 to 145 C
(-40 to 293 F)
8 bar
(120 psi)
facing
1" NPT or BSP
conduit
connection
factory bonded to suit ANSI, DIN, and JIS standards
polyethylene foam facing for dusty or steamy environments
submergence shield, where flooding can occur (available only for XPS-10, XPS-15)
split flange for field mounting to suit ANSI, DIN, and JIS standards (not
Options
available for XPS-40)
2-wire twisted pair/ braided and foil shielded,
0.5mm² (20 AWG), PVC jacket Maximum separation: 100 m (330 ft)
2-wire twisted pair/braided and
Cable
foil shielded, 0.5mm² (20 AWG),
Wei ght* *
Maximum
Separation
Supply Source Transducers shall only be supplied by Siemens Milltronics certified controllers
Approvals
PVC jacket
0.8 kg
(1.7 lb)
365 m
(1200 ft)
CE***, CSA, FM, CENELEC/ATEX, INMETRO: See nameplate or consult Siemens Milltronics for current
* Universal flange fits ANSI, DIN, and JIS standards. ** Approximate shipping weight of transducer with standard cable length. *** EMC performance available upon request.
Page EN-8 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
1.3 kg
(2.8 lb)
365 m
(1200 ft)
RG-62 A/U coax Maximum separation: 365 m (1200 ft)
4.3 kg
(9.5 lb)
365 m
(1200 ft)
approvals.
8 kg
(18 lb)
365 m
(1200 ft)
Silicon Jacket
0.8 kg
(1.7 lb)
365 m
(1200 ft)
1.3 kg
(2.8 lb)
365 m
(1200 ft)
Outline and Dimensions
B
A
C
D
standard
radiatin g face
optional bonded flange
refer to associated instructions
optional split flange
refer to associated instructions
optional submergence shield
refer to associa ted
G
B
C
E
F
Dimension XPS-10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12
A 88 mm (3.4") 121 mm
(4.8")
B 122 mm
(4.8")
132 mm
(5.2") C to suit ANSI, DIN and JIS standards D* 128 mm
(5.0")
E 124 mm
(4.9")
F 152 mm
(6.0")
138 mm
(5.4")
158 mm
(6.2")
198 mm
(7.8") G 28 mm (1.1") 28 mm (1.1") 28 mm (1.1") 28 mm (1.1") 28 mm (1.1") 28 mm (1.1")
* nominal
175 mm (6.9")
198 mm (7.8")
204 mm (8.0")
206 mm (8.1")
229 mm (9.0")
235 mm (9.2")
88 mm (3.4") 121 mm
(4.8")
122 mm (4.8")
128 mm (5.0")
132 mm (5.2")
138 mm (5.4")
n / a n / a n / a n / a
n / a n / a n / a n / a
English
mmmmm
WARNING: Optional Split Flange, Bonded Flange, and Easy Aimer configurations
are
not
suitable for pressure applications.
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-9
mmmmm
Easy Aimer (typical model)
transducer
safety chain
Mounting
WARNING: Special handling precautions must be taken to protect the face of the transducer from any damage.
English
Mount the transducer so that it is above the maximum material level by at least the blanking value. Refer to the associated controller manual.
On liquid applications, mount the transducer face parallel to the liquid surface. On solids applications, use a Siemens Milltronics Easy Aimer to help aim the transducer.
Do not overtighten. Most applications require only hand tightening of the mounting hardware. Connect a safety chain from the transducer to a structural member to secure installation. Consider using the optional temperature sensor when a flanged transducer is used, when a fast temperature response is required, or in high temperature vessels.
Note: For pressure tight applications, install transducers hand tight plus ½ turn to 1½ turns.
PTFE tape or other appropriate sealant may be used to aid in sealing the threads for use in pressure applications.
Mounting – Solids Applications
WARNING: Improper installation may result in loss of process pressure.
Page EN-10 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
Mounting – Liquid Applications
flexible conduit
steel channel
coupling
transducer
safety chain
Flexible Conduit
Bracket
Submersible Plywood
safety chain
rigid metal conduit
coupling
submergence shield
Transducer with submergence shield, used in applications where flooding is possible.
Plywood mounting provides excellent isolation, but must be rigid enough to avoid flexing if subjected to loading.
Flexible conduit mounted transducer should not be subjected to wind, vibration, or jarring.
English
mmmmm
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-11
mmmmm
Flanged
coupling
bolt
gasket
customer flange, flat face only
Customer flanged standpipe. If a metal flange must be welded to pipe, refer to Liquid Applications - Standpipes in the
Transducer Applications Manual
.
factory flanged transducer
nut
Blind Flange
nipple welded to blind flange coupling
flange, gasket, and hardware supplied by customer.
Note: Tighten the flange bolts
evenly in order to ensure a good seal between the mating flanges.
Caution: Overtightening can cause performance degradation.
Mounting – Liquid Applications (cont’d)
English
Installation
Note: Installation shall only be performed by qualified personnel and in accordance with
local governing regulations.
Do not route cable openly. For optimum isolation against electrical noise, run cable separately in a grounded metal conduit. Seal all thread connections to prevent ingress of moisture.
Do not run cable near high voltage or current runs, contactors, and SCR control drives. For pressure tight applications, install transducers hand tight plus ½ to 1½ turns.
PTFE tape or other appropriate sealant may be used to aid in sealing the threads for use in pressure applications.
WARNING: Never attempt to loosen, remove, or disassemble process connection
while vessel contents are under pressure.
Page EN-12 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
Interconnection
wht
blk
drain/shield
extend cable using RG-62 A/U coax
wht
drain/shield
wht
blk
junction box
drain/shield
extend cable using 18 AWG shielded/twisted pair
Direct Connection
Connect the transducer directly to the Siemens Milltronics transceiver via the two conductor shielded cable.
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, the white, black, and shield wires are all connected separately. DO NOT tie the white and shield wires together.
Coaxial Connection
English
mmmmm
Connect the transducer to the Siemens Milltronics transceiver via a junction box and RG– 62 A/U coaxial cable. This setup is effective for combined runs up to 365 m (1200 ft).
Note: When connecting to a SITRANS LUT400, a SITRANS LUC500, a MultiRanger 100/
200, or a HydroRanger 200, do NOT use coaxial cable; see diagram below for proper procedure.
2-Wire Extension
(for SITRANS LUT400, SITRANS LUC500, MultiRanger 100/200, and HydroRanger 200 only)
A5E32282889 XPS/XCT Series Transducers – OPERATION MANUAL Page EN-13
mmmmm
English
Page EN-14 XPS/XCT Series Transducers – OPERATION MANUAL A5E32282889
Echomax XPS/XCT Driftsvejledning
Denne manual opridser de væsentligste karakteristika og funktioner af transducerne i serien Echomax XPS/XCT. Denne manual samt vort website: www.siemens.com/processautomation Siemens Milltronics repræsentant.
Vejledning i anvendelse af transducere
. Trykte eksemplarer kan fås hos din lokale
kan også findes på
Spørgsmål vedrørende indholdet af denne manual kan rettes til:
Siemens Milltronics Process Instruments Siemens AG 1954 Technology Drive, P.O. Box 4225 Industry Sector Peterborough, Ontario, Canada, K9J 7B1 76181 Karlsruhe Email: techpubs.smpi@siemens.com
Europæisk autoriseret repræsentant
Deutschland
Copyright Siemens Milltronics
Process Instruments 2013.
Ansvarsfragåelse
Alle rettigheder forbeholdes
Vi opfordrer brugerne til at anskaffe de autoriserede, indbundne manualer eller at læse de elektroniske versioner, der er udarbejdet og skrevet af Siemens Milltronics Process Instruments. Siemens Milltronics Process Instruments påtager sig intet ansvar for indholdet af delvise eller fuldstændige gengivelser af indbundne eller elektroniske versioner.
Skønt vi har kontrolleret, at indholdet af denne manual stemmer overens med de beskrevne instrumenter, kan der stadig forekomme variationer. Vi kan derfor ikke garantere en fuldstændig overensstemmelse. Indholdet af denne manual revideres jævnligt, og eventuelle rettelser inkluderes i de efterfølgende udgaver. Vi modtager gerne forslag til forbedringer. Retten til ændringer af de tekniske data forbeholdes.
Dansk
MILLTRONICS er et registreret varemærke, der tilhører Siemens Milltronics Process Instruments
Sikkerhedsvejledning
De anførte advarsler skal overholdes for at sikre egen og andres sikkerhed samt for at beskytte produktet og det tilhørende udstyr. Disse advarsler ledsages af en tydeliggørelse af graden af forsigtighed, der bør overholdes.
ADVARSEL: vedrører et advarselssymbol på produktet og betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til død, alvorlig personskade og/eller omfattende materielle skader.
ADVARSEL: betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til død, alvorlig personskade og/eller omfattende materielle skader.
PAS PÅ: betyder, at en manglende overholdelse af de nødvendige forholdsregler kan føre til omfattende materielle skader.
Bemærk: betyder vigtige oplysninger om produktet eller denne del af brugsvejledningen.
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-1
Reparation af instrumentet og ansvarsbegrænsning
Brugeren er ansvarlig for alle modifikationer og reparationer, der udføres på apparatet af brugeren eller dennes repræsentant.
Alle nye dele skal leveres af Siemens Milltronics Process Instruments Inc.
Kun defekte dele bør repareres.
Defekte dele må ikke genbruges.
Dansk
Side DA-2 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
Indledning
transducer
transducer­overflade
–3 db grænse
transmissionsakse,
vinkelret på
transducer-
overfladen
Dette produkt er beregnet til anvendelse i industriområder. Brugen af dette udstyr i et beboelsesområde kan forårsage interferens med forskellige frekvensbaserede kommunikationer.
Transducerne i serien Echomax XPS/XCT fungerer med Siemens Milltronics ultralydsniveauovervågningsprodukter.
Transduceren omdanner den elektriske sendeimpuls fra transceiveren til akustisk energi. Derefter omdanner den ekkoets akustiske energi tilbage til elektrisk energi til kontrolenheden.
Transduceroverfladen udsender akustisk energi, der udbreder sig med en amplitude, der falder omvendt proportionalt til kvadraten af afstanden. Den udbredte effekt er maksimal vinkelret på transduceroverfladen langs transmissionsaksen. Lydstrålen, hvis diameter betegnes strålevinklen, defineres som en kegle centreret omkring transmissionsaksen, med en grænse svarende til en reduktion af effekten til halvdelen (– 3 dB).
Dansk
XPS/XCT transducerne har en indbygget temperaturføler, der angiver lufttemperaturen til kontrolenheden.
Generel vejledning
ADVARSEL: Konstruktionsmaterialerne er valgt på basis af deres kemiske
kompatibilitet (eller inerti) ved almindelig brug. Hvis de skal udsættes for særlige omgivelser, bør foreneligheden kontrolleres i tabeller over kemiske kompatibiliteter inden installationen.
XPS/XCT Serien – Certifikat SIRA 99ATEX5153X
Dette udstyr kan anvendes i eksplosionsfarlige områder i forbindelse med alle gasser med temperaturklasserne T1, T2, T3 og T4 for XPS serien (XPS-10, XPS-15, XPS-30 og XPS-40) og klasserne T1, T2 og T3 for XCT serien (XCT-8 og XCT-12). XPS serien er kun godkendt til brug ved omgivende temperaturer i intervallet fra - 40 °C til 95 °C, og XCT serien er kun godkendt til
brug ved omgivende temperaturer i intervallet fra -40 °C til 145 °C. Disse apparater bør ikke anvendes uden for deres respektive temperaturinterval.
Installationen af dette udstyr skal udføres af tilstrækkeligt uddannet personale i henhold til de gældende normer.
Disse apparater bør kun strømforsynes fra et kredsløb, der omfatter en sikring af passende intensitet, der har en brydeevne på 4.000A. Denne sikring er inkluderet i Siemens Milltronics’ kontrolenheder.
Reparation af dette udstyr skal udføres i henhold til de gældende normer.
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-3
Dette udstyr er godkendt på baggrund af brugen af følgende materialer ved dets fremstilling:
XPS serien XCT serien
Hus Kynar®1710 Indkapsling Stycast LA-9823-76 Durapot® 861-F3 og 864
1.
Kynar® er et registreret varemærke, der tilhører ELF Atochem. Durapot® er et registreret varemærke, der tilhører Cotronics Corporation.
For en manuel omgåelse bruges den afbryder, der indgår i installationen af den tilhørende kontrolenhed i bygningen.
Kynar®710
XPS 30/40 serien – Certifikat SIRA 01ATEX5153X
Dette udstyr kan anvendes i eksplosionsfarlige, støvende områder med alle typer ledende eller ikke-ledende støv. Transducerne i serierne af typen XPS-30 og XPS-40 har en maksimal overfladetemperatur på 135 °C (275 °F) (Temperaturklasse T4). Disse enheder er godkendt til brug i et interval af omgivende temperaturer på fra -40 til 95 °C (-40 til 203 °F). Transducerne bør ikke anvendes uden for dette temperaturinterval. Ultralydstransducerne XPS-30 og XPS-40
Dansk
skal installeres, således at transduceroverfladen ikke udsættes for lys i væsentligt omfang. Installationen skal udføres af tilstrækkeligt uddannet personale i henhold til de gældende
normer. Reparation af dette udstyr skal udføres i henhold til de gældende normer og installationsvejledninger.
Disse apparater bør kun strømforsynes fra et kredsløb, der omfatter en sikring af passende intensitet, der har en brydeevne på 4.000A. Denne sikring er inkluderet i Siemens Milltronics’ kontrolenheder.
Dette udstyr er godkendt på baggrund af brugen af følgende materialer ved dets fremstilling:
Hus: Indkapsling: Stycast LA-9823-76
Kynar®710
For en manuel omgåelse bruges den afbryder, der indgår i installationen af den tilhørende kontrolenhed i bygningen.
Produktets mærkning
Bemærk: Kynar® polyvinylidenfluorid er modstandsdygtigt over for angreb fra de fleste
kemikalier ved de beskrevne driftsbetingelser. Hvis det skal udsættes for særlige omgivelser, bør foreneligheden dog kontrolleres i tabeller over kemiske kompatibiliteter inden installationen.
ADVARSEL: Dette produkt betegnes som trykbærende udstyr i henhold til
direktivet 97/23/ EF og er
ikke beregnet til brug som sikkerhedsanordning.
Side DA-4 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
XCT-8
XCT-8 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 145 °C V in: 1.77 V r.m.s.; 250 Vp Iin:44.2mAr.m.s.
Enclosure: IP66, IP68
0518
SIRA 99ATEX5153X
II2GD EExmIIT3
Siemens Milltronics Process Instruments, Peterborough
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA
- VEJA INSTRUÇÕES
KCC-REM-S49 Echomax
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
Class I, Zone 1, ExsIT4,Amb.Temp.:–40°C to 95°C
IC 3 145 DIPIP65/IP67 AEx X
Ex s I T , Amb. Temp.: –40°C to °C
NZ 08.3066
Class I, Div 2, Group A, B, C, D Class II, Div 2, Group F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
Ex mb IIC T3 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
OCP 0017
Ex mb IIC T3 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
XCT-12 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 145 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
SIRA 99ATEX5153X
II2GD EExmIIT3
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
OCP0017
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
ClassI,Zone1 ExsIT4,Amb.Temp.: 9
, DIP IP65 / 67 AEx X
–40°Cto 5°C
ExsIICT3 Amb.Temp.:–40°Cto145°C
IP
NZ 08.3066
Class I, Div 2, Group A, B, C, D Class II, Div 2, Group F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
0518
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA - VEJA INSTRUÇÕES
KCC-REM-S49 Echomax
XCT-12
Dansk
Bemærk:
Den viste produktkonfiguration er kun givet som eksempel.
Det viste serienummer er kun givet som eksempel.
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-5
XPS-10
XPS-10 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
ClassI,Zone1, ExsI/IICT4 DIP IP65 / 67 ANZEx 08.3066X
0518
SIRA 99ATEX5153X
II 2 GD EExmIIT4
KCC-REM-S49
Echomax
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Static Hazard,
Do Not Rub With Dry Cloth.
WARNING:
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA
- VEJA INSTRUÇÕES
OCP 0017
XPS-15 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40°C to 95°C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIP IP65 / 67 ANZEx 08.3066X
SIRA 99ATEX5153X
II2GD EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
0518
KCC-REM-S49
Echomax
Dansk
XPS-15
Bemærk:
Den viste produktkonfiguration er kun givet som eksempel.
Det viste serienummer er kun givet som eksempel.
Side DA-6 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
XPS-30
XPS-30 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp Iin:44.2mAr.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIP IP65 / 67 ANZEx 08.3066X
SIRA 99ATEX5153X
II 2G 1D EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
KCC-REM-S49
Echomax
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS (20 N-m)
ATENÇÃO - RISCO POTENCIAL DE CARGA
ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
XPS-40 ULTRASONIC TRANSDUCER
Serial No: GYZ / A1034567 Ambient Temp.: – 40 °C to 95 °C V in: 1.77 V r.m.s.; 250 Vp I in : 44.2 mA r.m.s.
Class I, Zone 1, Ex s I/IIC T4 DIPIP65/67 ANZEx 08.3066X
SIRA 99ATEX5153X
II 2G 1D EExmIIT4
Siemens Milltronics Process Instruments, Peterborough
Enclosure: IP66, IP68
KCC-REM-S49
Echomax
Static Hazard, Do Not Rub With Dry Cloth.WARNING:
Ex mb IIC T4 Gb Ex tb IIIC T135 °C Db DNV 12.0077 X
Class I, Div 2, Group A, B, C, D Class II, Div 1, Group E, F, G Per Dwg.: 0-9650017Z-DI-A Max. Torque: 15 FT–LBS (20 N-m)
ATENÇÃO - RISCO POTENCIAL DE CARGA
ELETROSTÁTICA - VEJA INSTRUÇÕES
OCP 0017
XPS-40
Bemærk:
Den viste produktkonfiguration er kun givet som eksempel.
Det viste serienummer er kun givet som eksempel.
Dansk
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-7
Tekniske data
XPS-10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12
Måleområde
Frekvens (kHz) Strålevinkel
0,3 - 10 m
(1 - 33 fod)
44 44 30 22 44 44
12 6 6 6 12 6
0,3 - 15 m
(1 - 50 fod)
0,6 - 30 m
(2 - 100 fod)
0,9 - 40 m
(3 -130 fod)
0,6 - 8 m
(2 - 26 fod)
0,6 - 12 m
(2 - 40 fod)
Omgivelser
Placering
Maksimal højde (m)
Omgivende temperatur
Dansk
Tr y k
Forureningsgrad
indendørs/
udendørs
2000 2000 2000 2000 2000 2000
-40 til 95 C
(-40 til 203 F)
8 bar
(120 psi)
444444
indendørs/
udendørs
-40 til 95 C
(-40 til 203 F)
8 bar
(120 psi)
indendørs/
udendørs
-40 til 95 C
(-40 til 203 F)
Europa: 0,5 bar
N. Amerika:
15 psi
indendørs/
udendørs
-40 til 95 C
(-40 til 203 F)
Europa: 0,5 bar
N. Amerika: 15 psi
indendørs/
udendørs
-40 til 145 C
(-40 til 293 F)
8 bar
(120 psi)
indendørs/
udendørs
-40 til 145 C
(-40 til 293 F)
8 bar
(120 psi)
Konstruktion
PVDF PVDF PVDF PVDF Standard: PVDF
Hus
1" NPT eller
Montage
Valgmuligheder
Kabel
Vægt**
Maksimal afstand
Forsyningskilde Transducerne må kun forsynes fra kontrolenheder, der er godkendt af Siemens Milltronics
Godkendelser
BSP kabelrør­tilslutning
• fabrikssamlet iht. ANSI, DIN og JIS standarderne
• overflade af polyethylenskum til omgivelser m. støv el. damp
• neddykningsbeskyttelse til steder m. risiko for oversvømmelse (fås kun til XPS-10, XPS-15)
• delt flange til feltmontering iht. ANSI, DIN og JIS standarderne (fås ikke til XPS-40)
2-tråds parsnoet/flettet og folieafskærmet, 0,5mm² (20 AWG), kappe af PVC
0,8 kg
(1,7 lb)
365 m
(1200 fod)
CE***, CSA, FM, CENELEC/ATEX, INMETRO: Se på navneskiltet eller jf. Siemens Milltronics for de aktuelle godkendelser.
1" NPT eller BSP kabelrør­tilslutning
1,3 kg
(2,8 lb)
365 m
(1200 fod)
1-1/2" NPT eller BSP kabelrør­tilslutning
• 2-tråds parsnoet/flettet og folieafskærmet, 0,5mm² (20 AWG), kappe af PVC Maksimal afstand: 100 m (330 fod)
• RG-62 A/U koaksial Maksimal afstand: 365 m (1200 fod)
4,3 kg
(9,5 lb)
365 m
(1200 fod)
1-1/2" NPT eller BSP kabelrør­tilslutning
8 kg
(18 lb) 365 m
(1200 fod)
Ekstraudstyr: Universel* størrelse flange med PTFE­overflade
1" NPT eller BSP kabelrør­tilslutning
Kappe af silicone
0,8 kg
(1,7 lb)
365 m
(1200 fod)
1" NPT eller BSP kabelrør­tilslutning
1,3 kg
(2,8 lb)
365 m
(1200 fod)
* Universel flange, der passer til ANSI, DIN og JIS standarderne. ** Omtrentlig forsendelsesvægt af transducer med standard kabellængde. *** EMC-data fås på anfordring.
Side DA-8 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
Omrids og dimensioner
B
A
C
D
udstrålings­flade
standard
ekstraudstyr: sammensat flange jf. den tilhørende vejledning
ekstraudstyr: delt flange jf. den tilhørende vejledning
ekstraudstyr:
neddykningsbeskyttelse
jf. den tilhørende vejledning
G
B
C
E
Dimensioner XPS 10 XPS-15 XPS-30 XPS-40 XCT-8 XCT-12
A 88 mm (3,4") 121 mm (4,8") 175 mm (6,9") 206 mm (8,1") 88 mm (3,4") 121 mm (4,8") B 122 mm (4,8") 132 mm (5,2") 198 mm (7,8") 229 mm (9,0") 122 mm (4,8") 132 mm (5,2") C passende til ANSI, DIN og JIS standarderne D* 128 mm (5,0") 138 mm (5,4") 204 mm (8,0") 235 mm (9,2") 128 mm (5,0") 138 mm (5,4") E 124 mm (4,9") 158 mm (6,2") ikke relevant ikke relevant ikke relevant ikke relevant F 152 mm (6,0") 198 mm (7,8") ikke relevant ikke relevant ikke relevant ikke relevant G 28 mm (1,1") 28 mm (1,1") 28 mm (1,1") 28 mm (1,1") 28 mm (1,1") 28 mm (1,1") * nominel
F
ADVARSEL: Konfigurationerne m. Delt flange, Sammmensat flange eller Easy
Aimer (ekstraudstyr) er
ikke egnet til anvendelser under tryk.
Dansk
Montage
ADVARSEL: Ved håndteringen skal der træffes særlige forholdsregler for at beskytte transducerens overflade mod beskadigelse.
Transduceren monteres, så den sidder i en afstand over materialets maksimale niveau, der mindst er lig med slukningsafstanden. Der henvises til manualen for den tilhørende kontrolenhed.
Ved anvendelser med væsker monteres transducerfladen parallelt med væskeoverfladen. Ved anvendelser med faste stoffer bruges en Siemens Milltronics Easy Aimer som hjælp til at rette transduceren ind.
Pas på ikke at stramme for meget. Ved de fleste anvendelser er det tilstrækkeligt at stramme udstyret med håndkraft. Forbind transduceren til et strukturelement med en sikkerhedskæde for at sikre installationen. Overvej at bruge en temperaturføler (ekstraudstyr), når der anvendes en transducer med flange, såfremt der kræves en hurtig respons på temperaturen, eller i beholdere ved høj temperatur.
Bemærk: Ved tryktætte anvendelser installeres transducerne med en stramning ved
håndkraft plus ½ til 1½ ekstra omgang. PTFE-tape eller et andet passende tætningsmiddel kan bruges til at tætne gevindene ved brug i trykanvendelser.
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-9
Montage – Anvendelser med faste stoffer
Easy Aimer (typisk model)
transducer
sikkerhedskæde
bøjeligt rør
stålrende
samling
transducer
sikkerhedskæde
Bøjeligt rør
Bjælke
Neddykkelig version Krydsfiner
sikkerhedskæde
stift metalrør
samling
neddykningsbeskyttelse
Transducer med neddykningsbeskyttelse, der bruges i anvendelser, hvor der er risiko for oversvømmelse.
Montering på krydsfiner giver en fremragende isolation men bør være tilstrækkelig stiv til ikke at bøjes, hvis den udsættes for belastning.
En transducer, der er monteret på et bøjeligt rør, bør ikke udsættes for vind, vibrationer eller stød.
Dansk
ADVARSEL: Ukorrekt installation kan medføre tab af procestryk.
Montage – Anvendelser med væsker
Side DA-10 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
Montage – Anvendelser med væsker (fortsat)
Med flange
samling
bolt
pakning
kundens flange, udelukkende plan overflade
Stigrør med flange hos kunden. Hvis der skal svejses en metallisk flange på røret, henvises der til Anvendelser med væsker – Stigrør i
Vejledning i
anvendelse af transducere
.
transducer med flange fra fabrikken
møtrik
Blindflange
nippel svejset på blindflange samling
flangen, pakningen og de øvrige dele leveres af kunden.
Bemærk: Stram flangens bolte jævnt for at sikre en god tætnng mellem modflangerne.
Pas på: Overdreven stramning kan forringe funktionsegenskaberne.
Dansk
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-11
Installation
Bemærk: Installationen må kun foretages af kvalificeret personale og under
overholdelse af de lokalt gældende regler.
Undgå at trække kablet utildækket. For en optimal isolation mod elektrisk støj bør kablet føres separat i et jordet metalrør. Tætn alle gevindsamlinger for at undgå fugtindtrængning.
Undgå at føre kablet i nærheden af højspænding eller stærkstrøm, kontaktorer eller SCR­styredrev. Ved tryktætte anvendelser installeres transducerne med stramning ved håndkraft plus ½ til 1½ ekstra omgang.
PTFE-tape eller et andet passende tætningsmiddel kan bruges til at tætne gevindene ved brug i trykanvendelser.
Dansk
ADVARSEL: Forsøg aldrig at løsne, afmontere eller adskille procestilslutningen,
mens indholdet er under tryk.
Side DA-12 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
Sammenkobling
hvid
sort
drain/afskærmn
forlæng kablet vha. RG-62 A/U koaks
hvid
drain/afskærmn
hvid
sort
tilslutningsdåse
drain/afskærmn
forlæng kablet vha. 18 AWG afskærmet/parsnoet kabel
Direkte forbindelse
Forbind transduceren direkte til Siemens Milltronics transceiveren via det afskærmede to­leder-kabel.
Bemærk: Ved tilslutning til en SITRANS LUT400, en SITRANS LUC500, en MultiRanger
100/200 eller en HydroRanger 200 forbindes den hvide ledning, den sorte ledning og afskærmningsledningen alle separat. Den hvide ledning og afskærmningsledningen MÅ IKKE forbindes med hinanden.
Dansk
Koaksial forbindelse
Forbind transduceren til Siemens Milltronics transceiveren via en tilslutningsdåse og RG–62 A/ U koaksialkabel. Dette arrangement er effektivt for en samlet afstand på op til 365 m (1200 fod).
Bemærk: Ved tilslutning til en SITRANS LUT400, en SITRANS LUC500, MultiRanger 100/
200 og HydroRanger 200 må koaksialkabel IKKE BRUGES; jf. den egnede procedure i nedenstående diagram.
2-Leder-forlængelse
(kun for SITRANS LUT400, SITRANS LUC500, , MultiRanger 100/200 og HydroRanger 200)
A5E32282889 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING Side DA-13
Dansk
Side DA-14 XPS/XCT Serie Transducere – DRIFTSVEJLEDNING A5E32282889
Loading...
+ 130 hidden pages