This technical manual describes the system board D2559, which is equipped
with one Intel
Further information about drivers is provided in the readme files on the hard
disk, on the supplied “ServerStart“ or “Update“ CDs.
You will find further information in the BIOS description.
Notational conventions
The meanings of the symbols and fonts used in this manual are as follows:
italicsindicates commands, menu items, file and path
fixed fontindicate system output on the monitor
semi-bold fixed
font
[Key symbol]indicates keys according to their representation on the
“quotation marks”indicates names and terms that are being empha-
Êindicates an operation that to be performed
®
processor.
names or software programs
indicates values to be entered through the keyboard
keyboard
If capital letters are to be entered explicitly, then the
Shift key is shown, e.g. [SHIFT] - [A] for A.
If two keys need to be pressed at the same time, then
this is shown by placing a hyphen between the two key
symbols.
sized.
V CAUTION!indicates warnings, which, if ignored, will endanger
your health, destroy the system or lead to the loss of
data.
Iindicates additional information, notes and tips
Table 1: Notational conventions
D2559 (TX150 S6)Technical Manual5
Page 6
Page 7
2Important notes
In this chapter you will find essential information regarding safety when working
with your server.
V CAUTION!
With the system board installed you must open the system to access the
system board. How to access the system board of your system is
described in the appropriate service supplement.
When handling the system board, refer to the specific notes on safety in
the operating manual and/or service supplement for the respective
server.
2.1Notes on safety
V CAUTION!
● The actions described in these instructions should only be performed
by authorized, qualified personnel. Equipment repairs should only be
performed by qualified staff. Any failure to observe the guidelines in
this manual, and any unauthorized openings and improper repairs
could expose the user to risks (electric shock, fire hazards) and could
also damage the equipment. Please note that any unauthorized
openings of the device will result in the invalidation of the warranty
and exclusion from all liability.
● Transport the device only in the antistatic original packaging or in
packaging that protects it from knocks and jolts.
● Only install expansions that are allowed for the system board. If you
install other expansions, you may damage the requirements and rules
governing safety and electromagnetic compatibility or your system.
Information on which system expansions are suitable can be
obtained from the customer service centre or your sales outlet.
● The warranty expires if the device is damaged during the installation
or replacement of system expansions.
D2559 (TX150 S6)Technical Manual7
Page 8
Notes on safetyImportant notes
V ● Components can become very hot during operation. Ensure you do
not touch components when making extensions to the system board.
There is a danger of burns!.
● Transmission lines to peripheral devices must be adequately
shielded.
● To the LAN wiring the requirements apply in accordance with the
standards EN 50173 and EN 50174-1/2. As minimum requirement
the use of a protected LAN line of category 5 for 10/100 MBps
Ethernet, and/or of category 5e for Gigabit Ethernet is considered.
The requirements of the specification ISO/IEC 11801 are to be
considered.
● Never connect or disconnect data transmission lines during a storm
(lightning hazard).
Batteries
V CAUTION!
● Incorrect replacement of lithium battery may lead to a risk of
explosion. The batteries may only be replaced with identical batteries
or with a type recommended by the manufacturer.
It is essential to observe the instructions in chapter “Replacing the
lithium battery”.
8Technical ManualD2559 (TX150 S6)
Page 9
Important notesNotes on safety
Modules with electrostatic-sensitive components
Systems and components that might be damaged by electrostatic discharge
(ESD) are marked with the following label:
Figure 1: ESD label
When you handle components fitted with ESDs, you must observe the following
points under all circumstances:
● You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.
● The equipment and tools you use must be free of static charges.
● Remove the power plug from the power socket before inserting or removing
boards containing ESDs.
● Always hold boards with ESDs by their edges.
● Never touch pins or conductors on boards fitted with ESDs.
● Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install/deinstall the board.
● Place all components on a static-safe base.
I You will find a detailed description for handling ESD components in the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
D2559 (TX150 S6)Technical Manual9
Page 10
CE CertificateImportant notes
Notes about boards
● During installation/deinstallation of the system board, observe the specific
instructions described in the service manual for the server.
● Remove the plug from the mains outlet so that system and system board are
totally disconnected from the mains voltage.
● To prevent damage to the system board, the components and conductors on
it, please take great care when you insert or remove boards. Take great care
to ensure that extension boards are slotted in straight, without damaging
components or conductors on the system board, or any other components,
for example EMI spring contacts
● Be careful with the locking mechanisms (catches, centring pins etc.) when
you replace the system board or components on it, for example memory
modules or processors.
● Never use sharp objects (screwdrivers) for leverage.
2.2CE Certificate
The shipped version of this board complies with the requirements
of the EEC directive 89/336/EEC "Electromagnetic compatibility".
Compliance was tested in a typical PRIMERGY configuration.
10Technical ManualD2559 (TX150 S6)
Page 11
Important notesEnvironmental Protection
2.3Environmental Protection
Environmentally friendly product design and development
This product has been designed in accordance with standards for ”environmentally friendly product design and development“. This means that the designers
have taken into account important criteria such as durability, selection of
materials and coding, emissions, packaging, the ease with which the product
can be dismantled and the extent to which it can be recycled.
This saves resources and thus reduces the harm done to the environment.
Notes on saving energy
Devices that do not have to be on permanently should not be switched on until
they need to be used and should be switched off during long breaks and on
completion of work.
Notes on packaging
Please do not throw away the packaging. We recommend that you do not throw
away the original packaging in case you need it later for transporting.
Notes on dealing with consumables
Please dispose batteries in accordance with local government regulations.
Do not throw batteries and accumulators into the household waste. They must
be disposed of in accordance with local regulations concerning special waste.
All batteries containing pollutants are marked with a symbol (a crossed-out
rubbish bin on wheels). In addition, the marking is provided with the chemical
symbol of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
Notes on labeling plastic housing parts
Please avoid attaching your own labels to plastic housing parts wherever
possible, since this makes it difficult to recycle them.
D2559 (TX150 S6)Technical Manual11
Page 12
Environmental ProtectionImportant notes
Returning, recycling and disposal
The device may not be disposed of with household rubbish. This
appliance is labelled in accordance with European Directive
2002/96/EC concerning used electrical and electronic appliances
(waste electrical and electronic equipment - WEEE).
The guideline determines the framework for the return and recycling
of used appliances as applicable throughout the EU. To return your
used device, please use the return and collection systems available
to you. You will find further information on this at www.fujitsu-siemens.com/recycling.
For details on returning and reuse of devices and consumables within Europe,
refer to the “Returning used devices” manual, or contact your Fujitsu Siemens
Computers branch office/subsidiary or our recycling centre in Paderborn:
Fujitsu Siemens Computers
Recycling Center
D-33106 Paderborn
Tel. +49 5251 8 18010
Fax +49 5251 8 18015
12Technical ManualD2559 (TX150 S6)
Page 13
3Features
3.1Overview
Processor
– one Intel
– processor socket LGA775 for Intel
1333 MHz Front Side Bus
Main memory
– four slots for main memory DDR2 667/800 MHz (unbuffered),
SDRAM memory modules with 256 MB up to 4 Gbyte
– maximum 16 Gbyte of memory
– minimum 256 MB
– ECC multiple bit error detection and single bit error correction
– local BIOS update via bootable USB device or optional floppy disk
– remote BIOS update via LAN
– iRMC chipset with integrated VGA graphic controller
– ADM7462 thermal system management controller
®
Xeon™ processor
®
3210 MCH north bridge
®
ICH9R south bridge
®
Xeon™ processor with 800, 1066 or
External connectors
– 4x UHCI USB 2.0
– serial port (COM1)
– serial port (COM2) (optional)
– parallel port (optional)
– 2x PS/2 ports for keyboard and mouse
–VGA
– RJ45 LAN
– RJ45 Service LAN
D2559 (TX150 S6)Technical Manual13
Page 14
OverviewFeatures
Internal connectors
– dual USB 2.0
– SATA (1-4) multilane
–2x SATA
– floppy disk
– SAS/SATA/HD Activity LED
– front panel
– CPU fan 4 pins
– system fan 4 pins
– 4x system fans 5 pins
– PC98
– power (12V, -12V, 5V, 3.3V and 5V auxiliary)
– 12V (CPU) power
– intrusion detection
–SMB
PCI slots
– 3 x PCI (32 Bit / 33 MHz)
– 2 x PCI Express x8
– 1 x PCI Express x4
BIOS features
– Phoenix System BIOS V 6.00
– SMBIOS 2.34 (DMI)
– MultiProcessor specification 1.4
– Server Hardware Design Guide 3.0
– WfM 2.0
– ACPI 1.0b support with extensions from ACPI 2.0/3.0
– USB keyboard/mouse
– boot possible from:
– 120 MB floppy disk drive or USB floppy disk drive
– CD-ROM
– USB 2.0 devices
–LAN
– no Alert on LAN
– console redirection support
– OEM logo
– memory disable
14Technical ManualD2559 (TX150 S6)
Page 15
FeaturesOverview
Environmental protection
Battery in holder for recycling
Form factor, slot compatibility list
– ATX dimension: 305 mm x 244 mm
– ACPI 1.0b, OnNow, PCI 2.3, PCI Express 1.0a, WfM 2.0, SHDG 3.0,
MPS 1.4, IPMI 2.0, PCI SHPC 1.0, USB2.0
CSS (Customer Self Service)
This system board supports the CSS functionality. You will find a description of
CSS functionality in the operating manual of your server.
TPM (option)
The system board is optional equipped with a TPM (Trusted Platform Module)
by the manufacturer. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker
Drive Encryption).
The TPM is activated via the BIOS system (for more information, refer to the
Fujitsu Siemens Computers BIOS manual).
V CAUTION!
– When using the TPM, note the program descriptions provided by the
third party manufacturers.
– You must also create a backup of the TPM content. To do this, follow
the third party manufacturer's instructions. Without this backup, if the
TPM or the system board is faulty you will not be able to access your
data.
– If a failure occurs, please inform your service about the TPM
activation before it takes any action, and be prepared to provide them
with your backup copies of the TPM content.
D2559 (TX150 S6)Technical Manual15
Page 16
Main memoryFeatures
3.2Main memory
The system board supports up to 16 Gbyte ECC main memory. 4 slots
(2 memory banks with 2 modules) are available for the main memory. Each
memory bank can be populated with 256 Mbyte, 512 Mbyte, 1 Gbyte, 2 Gbyte
or 4 Gbyte unbuffered DDR2 memory modules.
ECC memory modules are supported only.
I You will find the descriptions how to install memory modules in the
Options Guide of your server.
Module population
DIMM 1A
DIMM 2A
DIMM 1B
DIMM 2B
Figure 2: Main memory
– If the memory modules are populated in pairs, each pair must consist of
– The module capacity between pairs can differ: pair 2A/2B can be populated
with two 512 Mbyte memory modules and pair 1A/1B with two 1 Gbyte
memory modules.
16Technical ManualD2559 (TX150 S6)
Page 17
FeaturesMain memory
Following table shows examples for configurations
Mode
singlechannel
single/dualchannel
1
dual-channel
1
The dual-channel mode is only activated, if the size of the memory module in socket
DIMM 2A is equal to the summary of the sizes of the memory modules in the sockets
DIMM 1A and DIMM 1B.
Example: DIMM 1A = 512 MB, DIMM 1B = 512 MB, DIMM 2A = 1 GB
DIMM 1A
(black)
populated---
populatedpopulatedpopulated-
populated-populated-
populatedpopulatedpopulatedpopulated
DIMM 2A
(blue)
DIMM 1B
(black)
DIMM 2B
(blue)
D2559 (TX150 S6)Technical Manual17
Page 18
PCI busFeatures
3.3PCI bus
Slot 6
PCIe x8
Slot 5
PCIe x8
Slot 4
PCIe x4
Slot 3
PCI 32 Bit / 33 MHz
Slot 2
PCI 32 Bit / 33 MHz
Slot 1
PCI 32 Bit / 33 MHz
Figure 3: PCI slots
PCI slots
6
5
4
3
2
1
The following table shows an overview of the PCI slots:
PCI slot32bitFrequency
Description
in MHz
132 bit3332 bit PCI slot
232 bit3332 bit PCI slot
332 bit3332 bit PCI slot
4PCI e x4 slot
5PCI e x8 slot
6PCI e x8 slot
PCI, PCI Express interrupts
Each device connected to a PCI bus or PCI Express can use up to four interrupt
signals depending on the functionality.
18Technical ManualD2559 (TX150 S6)
Page 19
FeaturesPCI bus
PCI and PCI-X buses use four lines named INTA to INTD, typically connected
to all devices on the bus in order to periodically balance interrupt load. An
interrupt signal may thereby be used simultaneously by multiple devices
(interrupt sharing).
PCI Express devices send their interrupts through messages. This avoids
restrictions in wiring.
The following interrupt signals are used in the system:
Slot/devicePropertyInterrupt signal
VGAiRMC graphicInt B
LANBCM5755T Int A
Slot 6PCIe x8Int A, B, C, D
Slot 5PCIe x8Int A, B, C, D
Slot 4PCIe x4Int A, B, C, D
Slot 3PCI (33 MHz)Int C, D, F, G
Slot 2PCI (33 MHz)Int F, G, C, D
Slot 1PCI (33 MHz)Int G, F, D, C
Assignment of the PCI interrupts
If you select Auto in the BIOS setup, the interrupts are assigned automatically
and no further settings are required.
D2559 (TX150 S6)Technical Manual19
Page 20
Screen resolutionFeatures
3.4Screen resolution
Depending on the operating system used the screen resolutions in the following
table refer to the graphic controller on the system board. The MATROX G200
graphic controller is integrated in the iRMC (integrated Remote Management
Controller).
Screen resolutionMax. color depthMax. frequency
640 x 480 Hz32 Bit85 Hz
800 x 600 Hz32 Bit85 Hz
1024 x 768 Hz32 Bit75 Hz
1152 x 864 Hz24 Bit60 Hz
1280 x 1024 Hz24 Bit60 Hz
1600 x 1200 Hz16 Bit60 Hz
If you are using an external graphic controller, you will find details of supported
screen resolutions in the operating manual or technical manual supplied with
the graphic controller.
3.5Temperature / system monitoring
Temperature and system monitoring aim to reliably protect the computer
hardware against damage caused by overheating. In addition, any unnecessary
noise is also prevented by reducing the fan speed, and information is provided
about the system status.
The temperature and system monitoring are controlled by an onboard controller.
The following functions are supported:
Temperature monitoring
Measurement of the processor and the system internal temperature by an
onboard temperature sensor, measurement of the ambient temperature by a
2
C temperature sensor.
I
20Technical ManualD2559 (TX150 S6)
Page 21
FeaturesTemperature / system monitoring
Fan monitoring
The CPU, power supply unit and system fans are monitored. Fans that are no
longer available, blocked or sticky fans are detected.
Fan control
The fans are regulated according to temperature.
Sensor monitoring
The removal of, or a fault in, a temperature sensor is detected. Should this
happen all fans monitored by this sensor run at maximum speed, to achieve the
greatest possible protection of the hardware.
Voltage monitoring
When voltage exceeds warning level high or falls below warning level low an
alert will be generated.
Cover monitoring
Unauthorized opening of the cover is detected, even when the system is
switched off. However, this will only be indicated when the system is switched
on again.
System Event Log (SEL)
All monitored events of the system board are signalized via the Global Error
LED and recorded in the System Event Log. They could be retrieved in the BIOS
Setup or via ServerView.
D2559 (TX150 S6)Technical Manual21
Page 22
LEDsFeatures
3.6LEDs
Figure 4: LEDs
CE
D
B
DIMM1B
DIMM2B
G
Super
I/O
A
CPU
DIMM1A
DIMM2A
MCH
F
F
F
Battery
CSS
button
F
iRMC
F
F
Slot 6
LAN
Slot 5
Slot 4
RAID
Slot 3
key
PCI 32 Bit / 33 MHz
Slot 2
PCI 32 Bit / 33 MHz
Slot 1
PCI 32 Bit / 33 MHz
E
PCIe x8
PCIe x8
PCIe x4
E
E
E
E
LED s A, B and C are visible from outside on the rear of the server. All the other
LEDs are only visible, if the cover of the server has been opened.
22Technical ManualD2559 (TX150 S6)
Page 23
FeaturesLEDs
The LEDs have the following meaning:
LED IndicatorMeaning
A - GEL
(Global Error
LED)
amber indicates a prefailure
amber flashing indicates a failure. Reasons for a failure
may be:
- overheating of one of the sensors
- sensor defect
- fan defect
- CPU error
- Software detected an error
B - CSS
(Customer Self
Service)
yellowindicates a prefailure
yellow flashing indicates a failure
C - Identification blueserver is identified via ServerView
D - memoryambermemory module failure
E - CPU/system
amberfan failure
fans
F - controllerambercontroller failure
G - iRMC healthy green blinkingiRMC (integrated Remote Management
Controller) is okay
If the server has been powered off (power-plugs must be disconnected) it is
possible to indicate the faulty component by pressing the CSS button.
D2559 (TX150 S6)Technical Manual23
Page 24
Interfaces and connectorsFeatures
3.7Interfaces and connectors
12345
Super
I/O
CPU
28
DIMM1A
DIMM2A
DIMM1B
DIMM2B
MCH
23
Battery
22
CSS
button
iRMC
21
20
27
26
25
24
Figure 5: Schematic view of the system board D2559
Slot 6
LAN
Slot 5
Slot 4
RAID
Slot 3
key
PCI 32 Bit / 33 MHz
Slot 2
PCI 32 Bit / 33 MHz
Slot 1
PCI 32 Bit / 33 MHz
PCIe x8
PCIe x8
PCIe x4
1 = parallel port (optional)15 = SATA 6
2 = CPU fan16 = USB DAT
3 = slots for main memory modules 17 = USB intern
4 = PC9818 = system fan 3
5 = front panel19 = system fan 2
6 = floppy disk drive20 = SMB1
7 = power supply ATX PWR121 = intrusion
8 = system fan 522 = jumpers (see page 28)
9 = system fan 423 = HDD activity
6
7
8
9
10
11
12
13
14
15
16
17
18
19
24Technical ManualD2559 (TX150 S6)
Page 25
FeaturesInterfaces and connectors
10 = USB24 = PCI slots
11 = power supply ATX 12V25 = RAID key
12 = CSS button26 = serial interface 2
13 = Mini SAS27 = system fan 1
14 = SATA 528 = external ports
RAID key
The SATA SW RAID 5 functionality will be activated by installing a license key
(RAID key).
3.7.1External ports
24
1
1112
Figure 6: External ports of the system board D2559
1 = CSS LED (yellow)/
7 = USB port 2
53
68109
7
Global Error LED (amber)/
Identification LED (blue)
2 = PS/2 mouse connector8 = USB port 3
3 = parallel interface (optional)9 = USB port 4
4 = service LAN connector 10 = VGA port
5 = system LAN connector 11 = serial interface COM1
6 = USB port 112 = PS/2 keyboard connector
The serial interface COM1 can be used as default interface or to communicate
with the iRMC.
D2559 (TX150 S6)Technical Manual25
Page 26
Interfaces and connectorsFeatures
LAN connectors
On this system board you will find two LAN controllers: a Gigabit LAN controller
(Broadcom BCM5755T) and a service LAN controller.
The Gigabit LAN controller BCM5755T supports the transfer rates of
10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The Service LAN controller supports the
transfer rates of 10 Mbit/s and 100 Mbit/s.
The LAN controllers support WOL function through Magic Packet™.
It is also possible to boot a device without its own boot hard disk via LAN. Here
Intel PXE is supported.
The service LAN port serves as management interface and is prepared for
RemoteView.
The LAN connectors are equipped each with two LEDs (light emitting diode)
indicating the transfer rate and the activity.
21
Figure 7: LAN connector system LAN controller
1 LAN transfer rate green +
offtransfer rate 10 Mbit/s
yellow
greenontransfer rate 100 Mbit/s
yellowontransfer rate 1000 Mbit/s
2 LAN link/activitygreenonLAN connection
offno LAN connection
flashingLAN transfer
26Technical ManualD2559 (TX150 S6)
Page 27
FeaturesInterfaces and connectors
21
Figure 8: LAN connector service LAN controller
1 LAN transfer rate greenofftransfer rate 10 Mbit/s
greenontransfer rate 100 Mbit/s
2 LAN link/activitygreenonLAN connection
offno LAN connection
flashingLAN transfer
D2559 (TX150 S6)Technical Manual27
Page 28
Settings with jumpersFeatures
3.8Settings with jumpers
defaultRCVRPWD SKIP
Figure 9: Jumpers
Recovering system BIOS - jumper RCVR
RCVR enables recovery of the old system BIOS after an attempt to update has
failed. To restore the old system BIOS you need a Flash BIOS Diskette (please
call our customer service centre).
being setThe system boots from the “Flash BIOS floppy disk“ from drive
A and reprograms the system BIOS on the board.
defaultThe System BIOS is started with the system BIOS from the
system board (default setting).
Skipping the password query - jumper PWD SKIP
PWD SKIP is used to define whether the password is queried at system startup,
if the password protection is enabled in BIOS Setup (in Security menu, the
Password field must be set to Enabled).
being setThe password query is skipped. Passwords are deleted.
defaultThe password query is effective (default setting).
28Technical ManualD2559 (TX150 S6)
Page 29
4Replacing the lithium battery
In order to save the system information permanently, a lithium battery is
installed to provide the CMOS-memory with a current. When the charge is too
low or the battery is empty, a corresponding error message is provided. The
lithium battery must then be replaced.
V The lithium battery must be replaced with an identical battery or a battery
type recommended by the manufacturer (CR2032).
Do not throw lithium batteries into the trash can. It must be disposed of
in accordance with local regulations concerning special waste.
Make sure that you insert the battery the right way round. The plus pole
must be on the top!
4
2
1
3
Figure 10: Replacing the lithium battery
Ê Press the locking spring into direction of the arrow (1), so that the lithium
battery jumps out of its socket.
Ê Remove the battery (2).
Ê Insert a new lithium battery of the same type into the socket (3) and (4).
D2559 (TX150 S6)Technical Manual29
Page 30
Page 31
Abbreviations
The technical terms and abbreviations given below represent only a selection of
the full list of common technical terms and abbreviations.
Not all technical terms and abbreviations listed here are valid for the described
system board.
ACPI
Advanced Configuration and Power Interface
ASR&R
Automatic Server Recovery and Restart
ATA
Advanced Technology Attachment
BBU
Battery Backup Unit
BIOS
Basic Input Output System
BMC
Baseboard Management Controller
CMOS
Complementary Metal Oxide Semiconductor
COM
COMmunication port
CPU
Central Processing Unit
DDR
Double Data Rate
DIMM
Dual In-line Memory Module
D2559 (TX150 S6)Technical Manual31
Page 32
Abbreviations
DIP
Dual In-line Package
DMI
Desktop Management Interface
DRAM
Dynamic Random Access Memory
ECC
Error Correction Code
EEPROM
Electrical Erasable Programmable Read Only Memory
EPROM
Erasable Programmable Read Only Memory
EMRL
Embedded RAID Logic
EVRD
Enterprise VRD
HPC
Hot-plug Controller
ICE
In Circuit Emulation
IDE
Integrated (intelligent) Drive Electronics
IME
Integrated Mirror Enhanced
IOOP
Intelligent Organization Of PCI
IPMB
Intelligent Platform Management Bus
32Technical ManualD2559 (TX150 S6)
Page 33
IPMI
Intelligent Platform Management Interface
iRMC
integrated Remote Management Controller
LAN
Local Area Network
LED
Light Emitting Diode
MPS
Multi Processor Specification
NMI
Non Maskable Interrupt
OEM
Original Equipment Manufacturer
OHCI
Open Host Controller Interface
Abbreviations
OS
Operating System
PCI
Peripheral Components Interconnect
PDA
Prefailure Detection and Analyzing
PIO
Programmed Input Output
PLD
Programmable Logic Device
PS(U)
Power Supply (Unit)
D2559 (TX150 S6)Technical Manual33
Page 34
Abbreviations
PWM
Puls Wide Modulation
PXE
Preboot eXecution Environment
RAID
Redundant Array of Inexpensive Disks
RSB
Remote Service Board
RST
ReSeT
RTC
Real Time Clock
SAS
Serial Attached SCSI
SATA
Serial ATA
SCSI
Small Computer Systems Interface
SDDC
Single Device Data Correction
SDRAM
Synchronous Dynamic Random Access Memory
SHDG
Server Hardware Design Guide
SMB
System Management Bus
SMM
Server Management Mode
34Technical ManualD2559 (TX150 S6)
Page 35
SMP
Symmetrically Multi Processing
UHCI
Unified Host Controller Interface
USB
Universal Serial Bus
VGA
Video Graphics Adapter
VRD
Voltage Regulator Down
VRM
Voltage Regulator Module
WfM
Wired for Management
WOL
Wake up On LAN
Abbreviations
D2559 (TX150 S6)Technical Manual35
Page 36
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.