See section Field data of ISO transponders (MDS D) (Page 56).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
8.8.2
Information for RF300 compatibility
Note
Compatibility with SIMATIC RF300 depending on MLFB number
Only the MDS D160 with MLFB
8.8 MDS D160
Area of application Thanks to its rugged packaging, the MDS D160 is a transponder that
can be used under extreme environmental conditions. It is washable,
heat-resistant and resistant to all chemicals generally used in the
Memory size 112 bytes of EEPROM user memory
laundry process.
Typical applications are, for example:
• Rented work clothing
• Hotel laundry
• Surgical textiles
• Hospital clothing
• Dirt collection mats
• Clothing for nursing homes/hostels
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
6GT2600-0AB10 is compatible with SIMATIC RF300.
307
ISO transponder
8.8.3
Ordering data
Article number
MDS D160
6GT2600-0AB10
Article number
Spacer
6GT2690-0AG00
8.8.4
Mounting on metal
Mounting on metal
①
Transponder
②
Metal carrier
③
Spacer
h
≥ 10 mm
Note
Going below the minimum distance (h)
If the minimum distance (h) is not observed, a reduction of the fie
In critical applications, it is recommended that a test is performed.
Flush-mounting
8.8 MDS D160
Table 8- 18 Ordering data for MDS D160
Table 8- 19 Ordering data for MDS D160 accessories
Figure 8-17 Mounting the MDS D160 on metal with spacer
Flush-mounting of the MDS D160 in metal is not permitted!
SIMATIC RF300
308System Manual, 07/2017, C79000-G8976-C345-07
ld data results.
ISO transponder
8.8.5
Technical specifications
6GT2600-0AB10
Product type designation
SIMATIC MDS D160
Memory
Memory configuration
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Recommended distance to metal
≥ 10 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
Mechanical strength
8.8 MDS D160
Table 8- 20 Technical specifications for the MDS D160
• UID • 8 bytes
• User memory• 112 bytes EEPROM
• OTP memory• 16 bytes (EEPROM)
Write/read distance (Sg) Dependent on the reader used, see section "Field
Housing
• Material
• Color
• during write/read access
• outside the read/write field • -40 … +175 °C
• during storage • -25 to +100 ℃
• PPS
• beige
• -25 … +85 °C
• from +125 ℃: for 1000 hours, 20% reduction
of the limit distance
• at +175 ℃: 100 washing cycles tested
• at +220 ℃: Tested once for up to 30 seconds
• Isostatic pressure• 300 bar for 5 min
• Axial pressure • 1000 N for 10 s
• Radial pressure • 1000 N for 10 s
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
309
ISO transponder
6GT2600-0AB10
cess
MDS lifespan
At least 100 wash cycles
18 ms; 6 axes; 2000 repetitions/h
10 ... 2000 Hz; 3 axes; 2.5 h
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
16 x 3 mm
Weight
1.2 g
1)
2)
The processing instructions of the adhesive manufacturer must be observed.
Note
Regeneration time between washing cycles
The regeneration time for the MDS D160 between washing cycles must be at lea
8.8 MDS D160
Resistance to chemicals All chemicals normally used in the washing pro-
Degree of protection
• IP68
24 hours, 2 bar, +20 °C
• IPx9K
Shock according to IEC 68-2-271) 400 m/s2
Vibration according to IEC 68-2-61) 100 m/s2
Type of mounting
• Patched
• Sewn in
2)
• Glued
The values for shock and vibration are maximum values and must not be applied continuously.
SIMATIC RF300
310System Manual, 07/2017, C79000-G8976-C345-07
st 24 hours.
ISO transponder
8.8.6
Dimension drawings
Dimensional drawing of MDS D160
Dimensions in mm
Dimensional drawing of spacer
Dimensions in mm
8.8 MDS D160
Figure 8-18 Dimensional drawing of MDS D160
Figure 8-19 Dimensional drawing of spacer
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
311
ISO transponder
8.9
MDS D165
8.9.1
Features
MDS D165 (special version)
Characteristics
cation.
Memory size
112 bytes of EEPROM user memory
(Page 56).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP65
8.9.2
Ordering data
Article number
MDS D165 (special version ISO-CARD)
6GT2600-1AB00-0AX0
Type of delivery
8.9.3
Technical data
6GT2600-1AB00-0AX0
Product type designation
SIMATIC MDS D165
Memory
Memory configuration
8.9 MDS D165
Area of application The design of the transponder (self-adhesive label)
permits a variety of designs, guaranteeing optimum
dimensioning for the widest variety of applications.
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identifi-
Write/read range See section Field data of ISO transponders (MDS D)
Table 8- 21 Ordering data for MDS D165
Minimum order quantity: 1250 units (5 rolls with 250 units each)
Table 8- 22 Technical specifications for MDS D165
• UID • 8 bytes
SIMATIC RF300
312System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
6GT2600-1AB00-0AX0
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
durability of the adhesive.
Degree of protection
IP65
Design, dimensions and weight
Dimensions (L x W x H)
86 x 54 x 0.3 mm
1)
The processing instructions of the adhesive manufacturer must be observed.
8.9 MDS D165
• User memory• 112 bytes EEPROM
• OTP memory• 16 bytes (EEPROM)
Write/read distance (Sg) Dependent on the reader used, see section "Field
• Material • Top • PET plastic (label
material)
• Inlay • PET plastic (carrier
material)
• Antenna • Aluminum
• Bottom• Double-sided trans-
• Color • White
• during write/read access• -25 ... +80 °C
• outside the read/write field • -25 to +80 ℃
• during storage • +20 to +30 ℃
Can be stored for 2 years, determined by the
fer adhesive on silicon paper
Weight 1 g
Type of mounting Glued with self-adhesive label 1)
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
313
ISO transponder
8.9.4
Dimension drawing
Dimensions in mm
8.10
MDS D200
8.10.1
Features
MDS D200
Characteristics
up to product identification.
Memory size
256 bytes of EEPROM user memory
Mounting on metal
Yes, with spacer
ISO standard
15693 with Tag-it HFI technology
Degree of protection
IP67
8.10 MDS D200
Figure 8-20 Dimension drawing of MDS D165
Area of application From simple identification such as elec-
tronic barcode replacement/supplementation, through
warehouse and distribution logistics, right
Write/read range See section Field data of ISO transpond-
ers (MDS D) (Page 56).
SIMATIC RF300
314System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.10.2
Ordering data
Article number
MDS D200 (special version ISO-CARD)
6GT2600-1AD00-0AX0
Article number
(in conjunction with spacer 6GT2190-0AA00)
(not suitable for fixing directly onto metal)
8.10.3
Mounting on metal
Mounting on metal
h
≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
8.10 MDS D200
Table 8- 23 Ordering data for MDS D200
Table 8- 24 Ordering data for MDS D200 accessories
Spacer
(in conjunction with fixing pocket 6GT2190-0AB00)
Fixing pocket
Fixing pocket
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
Figure 8-21 Mounting of the MDS D200 on metal with spacer
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
315
ISO transponder
Flush-mounting
a
≥ 20 mm
h
≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
Note
If the minimum guide values (h) are not observed, a reductio
8.10.4
Technical data
6GT2600-1AD00-0AX0
Product type designation
SIMATIC MDS D200
Memory
Memory configuration
8.10 MDS D200
Figure 8-22 Flush-mounting of MDS D200 in metal with spacer
n of the field data results.
Table 8- 25 Technical specifications for MDS D200
• UID • 8 bytes
• User memory• 256 bytes EEPROM
SIMATIC RF300
316System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
6GT2600-1AD00-0AX0
Read cycles (at < 25 ℃)
> 1014
Write cycles (at < 25 ℃)
> 106
Data retention time (at < 25 ℃)
> 10 years
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
IP67
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810 1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810 1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85 x 54 x 0.8 mm
Weight
5 g
1
2)
The processing instructions of the adhesive manufacturer must be observed.
8.10 MDS D200
• OTP memory • 16 bytes (EEPROM)
Write/read distance (Sg) Dependent on the reader used, see section "Field
• Material• PET
• Color • White
• during write/read access • -20 to +60 ℃
• outside the read/write field • -20 to +60 ℃
• during storage • -20 to +60 ℃
Type of mounting
)
The values for shock and vibration are maximum values and must not be applied continuously.
• Fixing pocket
2)
• Glued
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
317
ISO transponder
8.10.5
Dimension drawing
Dimensions in mm
8.11 MDS D261
Figure 8-23 Dimension drawing of MDS D200
SIMATIC RF300
318System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.11
MDS D261
8.11.1
Features
MDS D261
Characteristics
cation.
Memory size
256 bytes of EEPROM user memory
(Page 56).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP65
8.11.2
Ordering data
Article number
MDS D261
6GT2600-1AA00-0AX0
Type of delivery
8.11.3
Technical data
6GT2600-1AA01-0AX0
Product type designation
SIMATIC MDS D261
Memory
Memory configuration
8.11 MDS D261
Area of application The design of the transponder (self-adhesive label)
permits a variety of designs, guaranteeing optimum
dimensioning for the widest variety of applications.
From simple identification such as electronic barcode
replacement/supplementation, through warehouse
and distribution logistics, right up to product identifi-
Write/read range See section Field data of ISO transponders (MDS D)
Table 8- 26 Ordering data for MDS D261
Minimum order quantity: 1250 units (5 rolls with 250 units each)
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Table 8- 27 Technical specifications of MDS D261
• UID • 8 bytes
319
ISO transponder
6GT2600-1AA01-0AX0
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Recommended distance to metal
≥ 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
durability of the adhesive
Degree of protection
IP65
Design, dimensions and weight
Dimensions (L x W x H)
55 x 55 x 0.3 mm
1)
The processing instructions of the adhesive manufacturer must be observed.
8.11 MDS D261
• User memory• 256 bytes EEPROM
• OTP memory• 16 bytes (EEPROM)
Write/read distance (Sg) Dependent on the reader used, see section "Field
• Material • Top • PET plastic (label
material)
• Inlay • PET plastic (carrier
material)
• Antenna • Aluminum
• Bottom• Double-sided trans-
• Color • White
• during write/read access• -20 ... +60 °C
• outside the read/write field • -20 … +85 °C
• During transportation and storage • +20 to +30 ℃
Can be stored for 2 years, determined by the
fer adhesive on silicon paper
Weight 1 g
Type of mounting Glued with self-adhesive label 1)
SIMATIC RF300
320System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.11.4
Dimension drawing
Dimensions in mm
8.12
MDS D324
8.12.1
Characteristics
MDS D324
Characteristics
Memory size
992 bytes of EEPROM user memory
sponders (MDS D) (Page 56)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67; IPx9K
8.12 MDS D324
Figure 8-24 Dimension drawing of MDS D261
Area of application Production and distribution logistics
and product identification
Can also be used in harsh environ-
ments under extreme environmental
conditions (e.g. with higher temperature
load).
Write/read range See section "Field data of ISO tran-
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
321
ISO transponder
8.12.2
Ordering data
Article number
MDS D324
6GT2600-3AC00
Article number
Spacer
6GT2690-0AK00
8.12.3
Mounting on metal
Mounting on metal
h
≥ 15 mm
8.12 MDS D324
Table 8- 28 Ordering data MDS D324
Table 8- 29 Ordering data MDS D324 accessories
SIMATIC RF300
322System Manual, 07/2017, C79000-G8976-C345-07
Figure 8-25 Mounting the MDS D124/D324/D424/D524/E624 and RF320T on metal with spacer
ISO transponder
Flush-mounting
h
≥ 15 mm
a
≥ 25 mm
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with metal screws (M3 counters
impact on the range.
8.12.4
Technical specifications
6GT2600-3AC00
Product type designation
SIMATIC MDS D324
Memory
Memory configuration
Read cycles (at < 40 ℃)
> 1014
Write cycles (at < 40 ℃)
> 106
Data retention time (at < 40 ℃)
> 10 years
8.12 MDS D324
Figure 8-26 Flush-mounting of the MDS D124/D324/D424/D524/E624 and RF320T in metal with
spacer
unk head screws). This has no tangible
Table 8- 30 Technical specifications of MDS D324
• UID • 8 bytes
• User memory• 992 bytes EEPROM
• OTP memory• 16 bytes (EEPROM)
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
323
ISO transponder
6GT2600-3AC00
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
Shock according to EN 60721-3-7 Class 7M31)
1000 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
27 x 4 mm
Weight
5 g
1)
2
3)
The processing instructions of the adhesive manufacturer must be observed.
8.12 MDS D324
Write/read distance (Sg) Dependent on the reader used, see section "Field
• Material• Epoxy resin
• Color • Black
• during write/read access • -25 to +125 ℃
• outside the read/write field • -40 to +140 ℃
• during storage • -40 to +140 ℃
Degree of protection to EN 60529
• IP67
• IPx9K
Type of mounting
• 1 x M3 screw
2)
≤ 1 Nm
• Glued 3)
The values for shock and vibration are maximum values and must not be applied continuously.
) To prevent it loosening during operation, secure the screw with screw locking varnish.
SIMATIC RF300
324System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.12.5
Dimension drawing
8.12 MDS D324
Figure 8-27 Dimension drawing of MDS D324
All dimensions in mm
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
325
ISO transponder
8.13
MDS D339
8.13.1
Characteristics
MDS D339
Characteristics
(Page 56).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP68/IPx9K
8.13.2
Ordering data
Article number
MDS D339
6GT2600-3AA10
Article number
Spacer
6GT2690-0AA00
(Ø x H): 22 x 60 mm
(Ø x H): 22 x 47 mm
8.13 MDS D339
Area of application Applications in production automation with high
temperature demands (up to +220 °C)
Typical application areas:
• Paintshops and their preparatory treatments
• Primer coat, electrolytic dip area, cataphoresis
with the associated drying furnaces
• Top coat area with drying furnaces
• Washing areas at temperatures > 85 °C
• Other applications with higher temperatures
Memory size 992 bytes of EEPROM user memory
Write/read range See section Field data of ISO transponders (MDS D)
Table 8- 31 Ordering data for MDS D339
Table 8- 32 Ordering data for MDS D339 accessories
Quick change holder
Quick change holder
6GT2690-0AH00
6GT2690-0AH10
SIMATIC RF300
326System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.13.3
Mounting on metal
Mounting on metal
h
≥ 30 mm
Flush-mounting
h
≥ 30 mm
a
≥ 100 mm
8.13 MDS D339
Direct mounting of the MDS D139/D339 on metal is not allowed. A distance of ≥ 30 mm is
recommended. This can be achieved using spacers (see "Ordering data (Page 326)").
Figure 8-28 Mounting the MDS D139/D339 on metal with spacer
It is possible to mount the MDS D139/D339 in metal. With large antennas, for example ANT
D5, this leads to a reduction of ranges.
Figure 8-29 Flush-mounting of the MDS D139/D339 in metal with spacer
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
327
ISO transponder
Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It is possible
to mount the MDS with
recommended that a test is performed in critical applications.
8.13.4
Cleaning the mobile data memory
Note
Do not clean the transponder with mechanical tools, sand
cleaning methods result in damage to the transponder.
Clean the transponder only with the cleaning agents listed in the section "Chemical
resistance of the MDS".
8.13.5
Technical specifications
6GT2600-3AA10
Product type designation
SIMATIC MDS D339
Memory
Memory configuration
Data retention time (at < 40 ℃)
> 10 years
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
8.13 MDS D339
metal screws (M5). This has no tangible impact on the range. It is
Write/read distance (Sg) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 56)"
• Material • PPS
SIMATIC RF300
328System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
6GT2600-3AA10
Recommended distance to metal
≥ 30 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
Shock according to EN 60721-3-7 Class 7M31)
500 m/s2
Vibration according to EN 60721-3-7 Class 7M31)
200 m/s2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
85 x 15 mm
Weight
50 g
1.5 Nm
1
2)
ing the MDS in high temperatures (expansion coefficient).
8.13 MDS D339
• Color • Black
• during write/read access • -25 to +100 ℃
• outside the read/write field • -40 to +220 ℃
• from +125 ℃: 20% reduction in the limit dis-
tance
•at +200 ℃: Tested up to 5000 hours or
6000 cycles
• at +220 ℃: Tested up to 2000 hours or
2000 cycles
• during storage • -40 to +100 ℃
Degree of protection to EN 60529
• IP68
2 hours, 2 bar, +20 °C
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Type of mounting 1 x M5 screw 2)
The values for shock and vibration are maximum values and must not be applied continuously.
For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damag-
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
329
ISO transponder
8.13.6
Use of the MDS D339 in hazardous areas
Identification
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
8.13 MDS D339
The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment
and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the 94/9/EC directive are met:
● EN 60079-0:2006
● EN 60079-15:2005
● EN 61241-0:2006
● EN 61241-1:2004
II 3 G Ex nA II T6
Ii 3 D Ex tD A22 IP68 T 210°C
KEMA 09 ATEX 0133 X
SIMATIC RF300
330System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
Note
Installations- und Betriebsbedingungen für den Ex-Schutzbereich:
a) Der Einsatz des Gerätes in der Nähe von stark ladungserzeugenden Prozessen ist
untersagt.
b) Das Gerät ist mechanisch geschützt zu montieren.
c) Die Montage muss auf eine
d) Die Reinigung darf nur mit feuchtem Tuch erfolgen.
Installation and operating conditions for hazardous areas:
a) Use of the equipment in the vicinity of processes generating high charges is not allowed.
b) Th
c) Installation must be performed on a grounded and conductive mounting surface.
d) Cleaning only with a wet cloth
Conditions d'installation et de mise en oeuvre pour la zone de protection Ex :
a)
b) L'appareil doit être monté de manière à être protégé mécaniquement.
c) Le montage doit être effectué sur un socle conducteur mis à la terre.
d) Nettoyage uniquement
8.13 MDS D339
m geerdeten, leitenden Untergrund erfolgen.
e equipment must be mechanically protected when installed.
L'utilisation de l'appareil près de processus générant de fortes charges est interdite.
avec un chiffon humide
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
331
ISO transponder
8.13.7
Dimensional drawing
MDS D339
8.13 MDS D339
Figure 8-30 Dimension drawing of the MDS D339
Dimensions in mm
SIMATIC RF300
332System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
8.14
MDS D400
8.14.1
Features
MDS D400
Characteristics
tion logistics right through to product identification.
(Page 56)"
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67
8.14.2
Ordering data
Article number
MDS D400
6GT2600-4AD00
Article number
(in conjunction with fixing pocket 6GT2190-0AB00)
(in conjunction with spacer 6GT2190-0AA00)
(not suitable for fixing directly onto metal)
8.14 MDS D400
Area of application
Memory size 2000 bytes of FRAM user memory
Write/read range See section "Field data of ISO transponders (MDS D)
Table 8- 34 Ordering data of MDS D400
Simple identification such as electronic barcode replacement/supplements, from warehouse and distribu-
Table 8- 35 Ordering data of MDS D400 accessories
Spacer
Fixing pocket
Fixing pocket
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
6GT2190-0AA00
6GT2190-0AB00
6GT2390-0AA00
333
ISO transponder
8.14.3
Mounting on metal
Mounting on metal
h
≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
8.14 MDS D400
It is possible to mount the MDS D400 on metal.
Figure 8-31 Mounting of the MDS D400 on metal with spacer
SIMATIC RF300
334System Manual, 07/2017, C79000-G8976-C345-07
ISO transponder
Flush-mounted in metal
a
≥ 20 mm
h
≥ 20 mm
①
Transponder
②
Metal
③
Non-metal
Note
If the minimum guide values (h) are not observed, th
data.
8.14.4
Technical specifications
6GT2600-4AD00
Product type designation
SIMATIC MDS D400
Memory
Memory configuration
8.14 MDS D400
Figure 8-32 Flush-mounting of MDS D400 in metal with spacer
is will result in a reduction of the field
Table 8- 36 Technical specifications for MDS D400
• UID • 8 bytes
• User memory • 2000 bytes FRAM
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
335
ISO transponder
6GT2600-4AD00
Read cycles (at < 25 ℃)
> 1012
Write cycles (at < 25 ℃)
> 1012
Data retention time (at < 25 ℃)
> 10 years
data of ISO transponders (MDS D) (Page 56)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
Recommended distance to metal
≥ 20 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
IP67
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810 1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85 x 54 x 0.8 mm
Weight
5 g
1)
2)
The processing instructions of the adhesive manufacturer must be observed.
8.14 MDS D400
• OTP memory • 16 bytes FRAM
Write/read distance (Sg) Dependent on the reader used, see section "Field
• Material• PVC
• Color • White
• during write/read access • -20 to +60 ℃
• outside the read/write field • -20 to +60 ℃
• during storage • -20 to +60 ℃
Type of mounting
• Fixing lug
2)
• Glued
The values for vibration are maximum values and must not be applied continuously.
SIMATIC RF300
336System Manual, 07/2017, C79000-G8976-C345-07
Loading...