Siemens PSO 4000 Quick Reference Manual

Page 1
WARNING
IF “FAIL” APPEARS ON THE DISPLAY, THE CALIBRATION REQUIRED LED (LEFT COLUMN) REMAINS LIT, OR THE CALIBRATED LED (RIGHT COLUMN) DOES NOT LIGHT, THE CALIBRATION PROCESS DID NOT COMPLETE. SHOULD THIS HAPPEN, CYCLE THE UNIT POWER AND THEN REPEAT STEP 2 ABOVE. IF “FAIL” APPEARS AGAIN, FURTHER TROUBLE­SHOOTING IS REQUIRED.
3. Remove the test shunt. The RX Occupancy LED should
light. If the RX Occupancy LED fails to light, the calibration process has failed (refer to the WARNING above). Inspect all equipme nt and connections and repeat steps 1 & 2. If the calibration fails again, further troubleshooting is required.
4. The RX Occupancy LED should light once the test
shunt has been removed. Repeat steps 1 – 4 for the OT2 Receiver. When the O T2 RX Occupancy LED lights, proceed to Receiver and Tra nsceiver Checkout Procedures, Section 7.5.1.
Receiver and Transceiver Ch eckout Procedures
1. On the OT1 Transceiver, scroll down the Main Menu
of the Receiver until INFO appears on the display.
2. Momentarily press the MENU Button and release it.
“+RX SIG LVL =” appears on the Display.
3. Take note of RX SIG LVL. T his is the normal receive
signal value. Verify the RX SIG LVL value is >300. If not, set TX LVL to High and perform calibration and checkout procedures again. If the value remains below 300 after selecting TX LVL=High, select a lower frequency where RX SIG LVL value is >300.
4. In the WSS containing the transmitter, remove the
transmitter’s signal to the track by disconnecting a transmitter lead from the track surge equipment
5. On the receiver, take note o f the Signal Level. If the
Signal Level is greater than 20, an unintended signal of like frequency may be pr esent.
WARNING
DO NOT PROCEED TO STEP 6 AND BEYOND UNTIL THE UNINTENDED SIGNAL OF LIKE FREQUENCY IS NO LONGER PRESENT (THIS MAY REQUIRE A FREQUENCY CHANGE TO AVOID UNINTENDED HARMONICS.) THIS CONDITION MUST BE RE SOLVED.
6. Verify that the RX LED found in the Occupancy
portion of the face of the unit is de-energized. If the LED remains lit, troubleshoot the unit.
7. Restore the Transmitter signal to the track by
reconnecting the lead in the transmitter’s track surge equipment.
8. Verify that the RX LED found in the Occupancy
portion of the face of the unit energizes. If the LEDs fail to light, troubleshoot the unit, re-calibrate, and perform Steps 1 - 7 again. When the unit passes, repeat steps 1 – 8 for the O T2 Receiver.
9. Verify proper operation of the track circuit
equipment before placing in service in accordance with railroad or agency procedures and applicable FRA rules.
10. Verify proper PSO 4000 operation by observing train
moves, per railroad or agency policy.
11. The system is now ready for operation.
NOTE
In the text on this side of the document and on the drawing on the reverse sid e of the document, all references to S ection numbers are those section numbers found within the Siemens Phase Shift Overlay 4000 (PSO 400 0) Installation and Instruction Manual, SIG-00­07-06.
QUICK REFERENCE GUIDE
INSTALL PSO 4000 TRANSCIEVER
MODULE AS REPEATER
Document Number SIG-QG-10-04
Version A.1
The following procedure should be used when installing Phase Shift Overlay 4000 (PSO 4000) Track Circuits utilizing PSO 4000 Transmitter, 7A471, PSO Receiver, 7A473, and PSO Transceiver Assembly, 7A475.
WARNING
VERIFY THAT THE PSO 4000 RECEIVER’S, AND TRANSCEIVER ASSEMBLY’S SOFTWARE, FREQUENCY, AND ADDRESS FORMATS ARE AS SPECIFIED BY THE RAILROAD’S OR AGENCY’S APPROVED WIRING OR INSTALLATION DIAGRAM. FAILURE TO DO SO MAY LEAD TO INCORRECT OR UNSAFE OPERATION OF THE TRACK CIRCUIT.
IF ANY RECEIVER IS CALIBR ATED IN POOR BALLAST CONDITIONS, IT MUST BE RE­CALIBRATED WHEN BALLAST CONDITIONS IMPROVE.
FAILURE TO FOLLOW THE R AILROAD’S OR AGENCY’S APPROVED WIRING OR INSTALLATION GUIDELINES REGARDING RECEIVER SETTINGS AND CALIBRATION MAY LEAD TO POSSIBLE UNSAFE OPERATION OF THE TRACK CIRCUIT.
AFTER CALIBRATION, VERIFY THAT THE TRACK C IRCUIT DE-ENERGIZES WHEN THE TRACK CIRCUIT IS SHUNTED WITH THE APPROPRIATE CALI BRATION RESISTANCE (0.06, 0.2, 0.3, 0.4, OR 0.5 OHMS). FAILURE TO DO SO MAY LEAD TO INCORRECT OR UNSAFE OPERATION OF THE TRACK CIRCUIT.
FOLLOWING INSTALLATION OR AFTER ANY RECEIVER MENU CHANGES HAVE BEEN MADE, RECALIBRATE THE RECEIVER AND TEST FOR PROPER OPERATION PER THE REQUIREMENTS SPECIFIED IN TABLE 7-2 AND TABLE 7-3 OF SIG-00-07-06, PSO 4000 I & I MANUAL.
Perform the following steps to install the PSO 4000 un its:
1. Install and connect all PSO equipment in the Wayside
Signaling Station (WSS) per the railroad’s or agency’s approved wiring or installation diagram.
2. Connect all required wiring per the railroad’s or
agency’s approved wiring or installation diagram.
3. Prior to beginning programming, verify LED
functionality using the *CHECK LED portion of the TEST menu per Section 5.2.7.2. If any LED fails to light following test, replace the unit.
4. Program each unit by performing Set to Default. Then
proceed through the setup (SETP) menu to program each unit per the railroad’s or agency’s approved written instructions.
With each unit properly installed and programmed per written instructions, calibrate the OT1 PSO Transceiver Assembly, 7A475 receiver (RX) as follows:
1. When the track ballast is good, connect a track test
shunt (hardwire, 0.06-ohm, 0.2-ohm, or as required) across the track at the receiver track connections. When the ballast is poor, connect the shunt across the track at a point 30 feet b eyond the receiver track connections. Verify solid connections of the shunt to each rail.
2. Scroll down the Main Menu until CAL appears on the
display. Then:
Press the MENU Button for two (2) seconds until
RX CAL appears.
Hold the MENU Button down until the release
(REL) message appears. Release th e MENU Button immediately once the releas e (REL) message appears.
As soon as the MENU button is released, the
armed (ARMD) message appears. Immediately press and release the MENU Button as soon as the ARMD message appears. This starts the calibration process. If the MENU Button is not pressed within two (2) seco nds, the calibration process cancels and the calibration process must be restarted.
*RX CAL flashes during the calibration process.
PASS or FAIL appears for two (2) seconds when
calibration is complete. When PASS appears, continue to Step 3. If FAIL appears, the CALIBRATION REQUIRED LED remains lit
-2-
Copyright © 2010-2014 Siemens
All Rights Reserved
-8-
-7-
Page 2
Diagnostic
Menu Navigate
+
N
B
Port
Power
Health
OUT
IN1 IN2
TX Enable
+
+
+
Made in USA
07-06_7A475_RPTR_APP_DWG 06-14-10
Diagnostic
Menu Navigate
RX
RX
+
N
B
Port
Power
Health
OUT2
OUT1
OUT3 IN1 IN2
+
+
+
+
+
Made in USA
PSO 4000 TRANSMITTER, 7A471
PSO 4000 RECEIVER, 7A473
PSO 4000 TRANSCEIVER
ASSEMBLY, 7A475
TUNED RECEIVER
COUPLER, 7A355-f
TUNED RECEIVER
COUPLER, 7A355-f
Diagnostic
Menu Navigate
+
N
B
Port
Power
Health
OUT2
OUT1
OUT3 IN1 IN2
TX Enable
+
+
+
+
+
RX
RX
Made in USA
+
= TWIST TWO TURNS PER FOOT
= 022700-1X EQUALIZER, H.D.
= 022585-1X ARRESTER, H.D.
= EARTH GROUND
LEGEND
PSO 4000 TRACK WIRES MAY BE #9 A.W.G. FOR LENGTHS UP TO 100 FEET. FOR LENGTHS BETWEEN 100 AND 300 FEET, TRACK WIRES SHOULD BE #6 A.W.G. IF LENGTHS EXCEED 300 FEET, REFER TO SECTION 7.2.3 FOR TRACK WIRE SELECTION AND SECTION 3.3 FOR COUPLER USAGE AND INSTALLATION.
PSO 4000 UNIT INPUTS AND OUTPUTS ARE CONNECTED PER THE RAILROAD'S OR AGENCY'S WRITTEN INSTRUCTIONS.
OT1 AND OT2 MUST BE DIFFERENT PSO FREQUENCIES.
NOTES
1.
2.
3.
MIN. #9 AWG TWISTED PAIR MIN. #9 AWG TWISTED PAIR
PRIME GND
EARTH GND
N1
B1
#6
#6
B2
OL-B12
N2
OL-N12
#16
Battery Charger
PRIME GND
EARTH GND
N1
B1
#6
#6
B2
OL-B12
N2
OL-N12
#16
Battery Charger
PRIME GND
EARTH GND
N1
B1
#6
#6
B2
OL-B12
N2
OL-N12
#16
Battery
Charger
THE POLARITY OF THESE CIRCUITS MUST BE OBSERVED, SINCE DAMAGE TO THIS EQUIPMENT WILL RESULT FROM REVERSED POLARITY.
WARNING
NOTES:
1. ALL WIRING TO BE #16 AWG UNLESS NOTED OTHERWISE
2. WIRE SIZE SHOWN IS MINIMUM GAUGE
-6-
-5-
-4-
-3-