Siemens NXAIR S User Manual

Page 1
Siemens Ltd., China
No.7 Wangjing Zhonghuan Nanlu,Chaoyang District, Beijing 100102 Tel: 0086-010-6476 8888 Fax:0086-010-6472 4912
Shenyang Branch
Jinan Rep. Office
5F, Shun Hua Yuan Commerical Club, No. 28 Shun Geng Rd. Jinan 250014, Shandong Tel: 0086-0531-8266 6088 Fax:0086-0531-8266 0836
Qingdao Rep. Office
Room 705-706, Crown Plaza,Qing Dao, No. 76,Xiang Gang Zhong Rd.,Qingdao, 266071, Shandong Tel: 0086-0532-8573 5888 Fax:0086-0532-8576 9963
Chengdu Branch
18/17F,Chuanxin Mansion 18,Sec.2,Renmin South Rd, Chengdu 610016, Sichuan Tel: 0086-028-8619 9499 Fax:0086-028-8619 9352
Wuhan Branch
19-20F,Jian Yin Tower No.709 Jianshe Avenue, Hankou 430015, Hubei Tel: 0086-027-8548 6688 Fax:0086-027-8548 6777
Xi'an Rep. Office
28F,Hi-Tech International Business Center No.33,Keji Rd.,Gaoxin District, Xi'an 710075, Shanxi Tel: 0086-029-8831 9898 Fax:0086-029-8833 8818
Shenzhen Branch
9F Han Tang Building OCT(overseas Chinese Town), Shenzhen 518053, Guangdong Tel: 0086-0755-2693 5188 Fax:0086-0755-2693 4476
Guangzhou Branch
16-17F,Dongshan Plaza 69,Xianlie Zhonglu, Guangzhou 510095, Guangdong Tel: 0086-020-8732 0088 Fax:0086-020-8732 0077
Nanning Rep. Office
No.109,Min Zu Rd.Investment Building,Room 908, Nanning 530022, Guangxi Tel: 0086-0771-552 0700 Fax:0086-0771-552 0701
Fuzhou Rep. Office
21F,China Bank Building, No.136,Wu Si Rd. Fuzhou 350003, Fujian Tel: 0086-0591-8750 0888 Fax:0086-0591-8750 0333
Kunming Rep. Office
27F,Bank Building, No.395, Youth Rd. Kunming 650011, Yunnan Tel: 0086-0871-315 8080 Fax:0086-0871-315 8093
Chongqing Rep. Office
Rm. 08A-11,18F, Metropolitan Business Mansion 68, Zourong Rd. Yuzhong District, Chongqing 400010 Tel: 0086-023-6382 8919 Fax:0086-023-6370 2886
No.298, Tianning Rd.,Minhang, Shanghai,China Post Code: 200245 Tel: 0086-021-2403 0000 Fax:0086-021-6492 4606
Order Number: JS016
2000
2006.10
SSLS-JS016-A
Page 2
Air -In s u l a t e d Me d iu m -Volt a g e
Switch gea r NXAIR S
Compact and Reliable in accordance with GB3906, DL404 (insulation), IEC 62271-200
Power Transmission and Distribution
Page 3
New Standards for the Market
Since the introduction of the type series NXAIR in 1998, Siemens has redefi ned the performance features of switchgear. Their extraordinary operational reliability due to modular design, their personal safety thanks to arc-fault tested construction, and the optimal operating symbols have set a standard on the market. Therefore, power supply utilities as well as industrial enterprises trust in NXAIR family when maximum reliability and quality is requested. And they are in best company, as proved by a basis of approx. 18,000 panels installed world-wide in power distribution systems - sometimes in most adverse operating conditions. To continue with this success also in the future, the complete NXAIR family has been revised and adjusted to today,s requirements.
2
Page 4
Prepared for the Future with IEC 62271-200
In autumn 2004, the existing switchgear standards for factory-assembled, metal-enclosed switchgear were redefi ned and documented in IEC 62271-200. Siemens has reacted to these changes by developing the SION vacuum circuit-breaker - one of twelve awarded corporate"inventions of the year" 2005.
Compact design in combination with high reliability predestined this circuit-breaker to application in NXAIR S switchgear. This made it possible not only to introduce one of the first switchgear types certified to the new standards on the market, but also to make them more compact in order to obtain e.g. lower building costs for the user, thus making the building more cost-effi cient.
Air-insulated medium-voltage switchgear NXAIR S is factory-assembled, type-tested, metal­enclosed switchgear for indoor installation according to GB3906, DL404 (insulation), IEC 62271-200(former IEC 60298).
Technical specs
Service continuity category LSC 2B (metal-clad)
Partition class PM (metal)
Internal arc classification IAC A FLR, I
IAC Internal arc classifi cation
A300 mm distance of indicators for test
FIndicators for test at the front LIndicators for test at the side R Indicators for test at the rear
I
40kA
sc
t = 1 s
In this way,NXAIR S switchgear is applicable without restrictions for wall-standing or free­standing arrangement in electrical service locations up to the maximum short-circuit current
,t
sc
3
Page 5
With NXAIR-Family, You Are on the Safe Side
Peace of Mind
For power supply companies and industrial enterprises, the certifi cation of the NXAIR family to the new standard offers very practical advantages: Smooth operation, exemplary availability and optimal security.
Factory-assembled, type-tested switchgear to GB3906, DL404 (insulation) and IEC 62271-200 Modular construction with pressure-resistant partitions (switching-device, connection, busbar and low-voltage compartments are exchangeable) Principle of bushing-type current transformers (combination of post insulator, current measurement, partition) More than 300,000 air-insulated switchgear panels of Siemens in operation world-wide Use of maintenance-free vacuum circuit­breakers Vacuum circuit-breaker and earthing switch type­tested in the panel Pressure-resistant partitions Use of standard components available world­wide Quality assurance to DIN EN ISO-9001
Page 6
Saves Lives
All switchgear types of the NXAIR family are approved for the internal arc classifi cation IAC A FLR, service continuity category LSC 2B, partition class PM. Thus they are universally applicable, meeting the highest requirements regarding personal safety.
All operations behind closed high-voltage door Metal enclosure and compartmentalization High-voltage door locked Switchgear with internal arc classi fication IAC A FLR (accessible from front, side and rear) for all short-circuit currents and arc­fault duration of 1 s Service continuity category LSC 2B (separate compartments for busbar, connection and switching device) Partition class PM (metal-clad) in pressure­resistant design Unambiguous switch position indicators and control elements on the high-voltage door Use of vacuum circuit-breakers Standard degree of protection IP4X Positively driven shutters Logical mechanical interlocking system
Technical data NXAIR S
Rated
-voltage kV 7.2 12
-frequency Hz 50 50
-short-duration power-frequency withstand voltage
kV 32 42
-lightning impulse withstand voltage kV 60 75
-short-circuit breaking current.max kA 40 40
-short-time withstand current, 4s.max
kA 40 40
-short-circuit making current.max kA 100 100
-peak withstand current.max kA 100 100
-normal current of busbar .max A 3150 3150
-normal current of feeders.max A3150 3150 Width
<
630 A,
=
1250 A 2000 A
<
31.5 kA
=
mm 600 600 mm 800 800
mm 800 800 2500 A mm 800 800 3150 A mm 1000 1000
Height mm 2150 2150 Depth mm 1350
mm 1450
<
31.5 kA,
1)
=
2)
3150 A, 40 kA
<
2500 A
=
1)
2)
1350 1450
1)
2)
Product range NXAIR S
Circuit-breaker panel Disconnector panel Metering panel Contactor panel Fixed-mounted switch-disconnector panel Bus sectionalizer
√ √ √ √ √ √
5
Page 7
With NXAIR-Family, You Are on the Economic Side
Increases Productivity
Functions such as modular construction, type tests of the circuit-breaker inside the switch­gear, selective shutdown of a possible arc fault, confi nement of an internal arc to the respective compartment, and therefore maximum opera­tional reliability provide for uninterrupted opera­tion and a considerable increase of productivity.
Modular panel design enables fast replace­ment of the respective compartments Selective shutdown of an arc fault possible Service continuity category LSC 2B (separate compartments for busbar, connection and switching device) Cable testing without isolating the busbar Principle of bushing-type current transformer Con finement of internal arc to respective compartment Use of maintenance-free vacuum circuit-breakers Control cables in metallic wiring ducts
6
Page 8
Customer Orientation
The compact design of the NXAIR family by using the new circuit-breaker series SION pays off twice for the operator. On the one hand, the building costs can be reduced, and on the other hand, the maintenance-free circuit-break­ers and the modular design enable continuous operation to a large extent without expensive shutdown times.
Maintenance-free vacuum circuit-breakers Mainte nance intervals of the switchgear > 10 years under normal conditions Interruption of operation reduced to a minimum by modular design and logical mechanical interlocking system Selective shutdown of a possible arc fault is possible Minimum space requirements due to compact design
E
A
B
A: Switching-device compartment B: Busbar compartment C: Connection compartment
D
C
D: Withdrawable circuit-breaker E: Low-voltage compartment