indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
The product/system described in this documentation may be operated only by
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
for the specific
0026 NÜRNBERG
05/2016 Subject to change
Contents
1 Information on the Internet ...................................................................................................................... 5
6 Technical data ...................................................................................................................................... 39
Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der
Kompaktbetriebsanleitung in Ihrer Sprache im Internet:
http://support.automation.siemens.com/ww/view/at/10806097
http://support.automation.siemens.com/ww/view/ch/10806097
http://support.automation.siemens.com/ww/view/de/10806097
http://support.automation.siemens.com/ww/view/li/10806097
http://support.automation.siemens.com/ww/view/lu/10806097
Please observe the warnings and additional information in the compact operating
instructions in your language in the Internet:
http://support.automation.siemens.com/ww/view/au/10806097
http://support.automation.siemens.com/ww/view/ca/10806097
http://support.automation.siemens.com/ww/view/gb/10806097
http://support.automation.siemens.com/ww/view/ie/10806097
http://support.automation.siemens.com/ww/view/us/10806097
http://support.automation.siemens.com/ww/view/za/10806097
Veuillez tenir compte des avertissements et informations supplémentaires de la notice de
service dans votre langue sur Internet:
http://support.automation.siemens.com/ww/view/be/10806097
http://support.automation.siemens.com/ww/view/ch/10806097
http://support.automation.siemens.com/ww/view/fr/10806097
http://support.automation.siemens.com/ww/view/lu/10806097
Si prega di tenere conto delle avvertenze e ulteriori informazioni nell’istruzione operativa
compatta nella relativa lingua in Internet:
http://support.automation.siemens.com/ww/view/it/10806097
Se ruega tener en cuenta las advertencias y las informaciones complementarias contenidas
en las instrucciones de servicio (resumen) en español en Internet:
http://support.automation.siemens.com/ww/view/cl/10806097
http://support.automation.siemens.com/ww/view/es/10806097
Dbejte prosím na výstražné pokyny a doplňkové informace v kompaktním návodu k obsluze
ve vašem jazyce na internetu:
http://support.automation.siemens.com/ww/view/cz/10806097
Vær venligst opmærksom på de advarselsanvisninger og ekstra informationer der findes på
dit sprog i kompaktdriftsvejledningen på internettet:
http://support.automation.siemens.com/ww/view/dk/10806097
Noudata lyhyen käyttöoppaan sisältämiä varoituksia ja huomio sen muutkin tiedot. Oman
kielisesi käyttöoppaan löydät internetistä osoitteesta:
http://support.automation.siemens.com/ww/view/fi/10806097
Λάβετε υπόψη τις υποδείξεις προειδοποίησης και τις πρόσθετες πληροφορίες των
συνοπτικών οδηγιών χρήσης που παρέχονται στη γλώσσα σας στο Διαδίκτυο:
Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt
használati útmutatóban található figyelmeztetéseket és további információkat:
Neem goed nota van de waarschuwingen en extra informatie in de compacte
gebruiksaanwijzing in uw taal op internet:
http://support.automation.siemens.com/ww/view/be/10806097
http://support.automation.siemens.com/ww/view/nl/10806097
Vennligst følg advarslene og annen informasjon i den kompakte bruksanvisningen, som du
finner på ditt språk på internett:
http://support.automation.siemens.com/ww/view/no/10806097
Proszę zwrócić uwagę na ostrzeżenia oraz dodatkowe informacje w kompaktowej instrukcji
obsługi, dostępnej w odpowiednim języku w internecie:
Observera varningshänvisningarna och extrainformationerna i kompaktbruksanvisningen
som finns på ditt språk på internet:
http://support.automation.siemens.com/ww/view/se/10806097
İnternette kendi dilinizdeki kompakt işletim kılavuzunda yer alan uyarı notlarına ve ek
These operating instructions apply to the following software version:
● SCALANCE W774/W734 with firmware as of version 5.2
Based on the operating instructions, you will be able to install and connect up the
SCALANCE W774/W734 correctly. The configuration and the integration of the device in a
WLAN are not described in these instructions.
You will find detailed information about configuration in the SCALANCE W700 configuration
manuals on the accompanying SIMATIC NET IWLAN CD under the file name:
Read the license conditions for open source software carefully before using the product.
2.2
Structure of the type designation
2.3
Security information
2.2 Structure of the type designation
You will find license conditions in the following documents on the supplied data medium:
● DOC_License_74.pdf
● DOC_LicenseScalanceW_76.htm
The type designation of the device is made up of several parts that have the following
meaning:
Siemens provides automation and drive products with industrial security functions that
support the secure operation of plants or machines. They are an important component in a
holistic industrial security concept. With this in mind, our products undergo continuous
development. We therefore recommend that you keep yourself informed with respect to our
product updates. Please find further information and newsletters on this subject at:
http://support.automation.siemens.com.
To ensure the secure operation of a plant or machine it is also necessary to take suitable
preventive action (e.g. cell protection concept) and to integrate the automation and drive
components into a state-of-the-art holistic industrial security concept for the entire plant or
machine. Any third-party products that may be in use must also be taken into account.
Please find further information at: http://www.siemens.com/industrialsecurity
There is a connection via the first Ethernet interface (Link).
alternately
Green
There is a connection via the second Ethernet interface (Link).
alternately
There is a connection via the WLAN interface.
alternately
the "MAC mode" parameter and is connected to no access point.
short, 1 x long
the "MAC mode" parameter and is connected to an access point.
Red
An error occurred during operation with the device.
time
R1
Note
Primary user (radar) on all enabled channels
If the device detects a primary user (for example radar signals) on all enabled channels of
the WLAN interface, the LED F
next 30 minutes. After this time, the device runs the scan again and c
primary user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened
even by restarting the device.
3.2 LED display
L2 Green Power supply L2.
P1
Green and yellow flashing
P2
Green and yellow flashing
Data transfer via the first Ethernet interface.
Data transfer via the second Ethernet interface.
R1 Green
Green and yellow flashing
Green
flashing briefly
Green
flashing 3 x
F
Red
R1 flashing yellow at the same
P1
Flashing yellow "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).
SCALANCE W774 in access point mode:
The WLAN interface is initialized and ready for operation.
SCALANCE W774 in client mode or SCALANCE W734:
Data transfer over the WLAN interface.
SCALANCE W774 in access point mode:
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
SCALANCE W774 in client mode or SCALANCE W734:
The client waits for the MAC address due to the setting "Automatic" for
SCALANCE W774 in client mode or SCALANCE W734:
The client waits for the MAC address due to the setting "Automatic" for
A primary user was found on all enabled channels.
is lit and R1 flashes. No data traffic is then possible for the
If you make changes to the configuration and restart immediately afterwards with the
reset button, the changes may be lost. If you restart the device using the WBM (menu
command "System >
EXEC Modus), the configuration changes are always retained.
Loading new firmware
Restoring the default parameters (factory defaults)
3.3 Reset button
The reset button (position ①) is on the top of the housing:
The reset button has the following functions:
●
To restart the device, press the Reset button briefly.
●
If the normal procedure with the "Load & Save" menu of Web Based Management is
unsuccessful, the reset button can be used to load new firmware. This situation can occur
if there is a power outage during the normal firmware update. You will find more detailed
information in the configuration manual SCALANCE W770/W730 WBM.
●
You will find more detailed information in the configuration manual SCALANCE
W770/W730 WBM.
Restart") or using the CLI (command "restart" in the Privileged
Fit the device so that there is a minimum clearance of 20 cm between antennas and
persons.
If a device is operated in an ambient temperature of more than 50 °C, the temperature of
the device housing may be higher than 70 °C. The device must therefore be installed so
that it is only accessible to service personnel or users that are aware of the reason for
restricted access and the required safety measures at an ambient temperature higher than
50 °C.
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or
cabinet must meet the requirements of at least IP54 in compliance with EN 60529.
Secure the device to the wall with two screws. The screws are not supplied with the device.
The type and length of the screws depend on the type of wall.
When used in an area with heavy load, the device is not adequately supported on an S7300 standard rail. Under such conditions, the device can come out of the mounting.
If you use the device in a heavy load area, mount it on an S7-1500 mounting rail or on the
wall.
Follow the steps below to fit the SCALANCE W774/W734 to an S7-300 standard rail:
1. Place the device on the upper edge of the S7-300 standard rail as shown in the figure.
2. Screw the housing to the S7-300 standard rail. The required screw ships with the
SCALANCE W774/W734.
Antennas installed outdoors must be within the area covered by a lightning protection
system. Make sure that all conducting systems entering from outdoors can be protected by
a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the VDE
0182 or IEC 62305 standard.
Suitable lightning protectors are available in the range of accessories of SIMATIC NET
Industrial WLAN:
Exception: When there is also DC power supplied via the antenna cable. In this case, only
the lightning protector LP798
WARNING
Danger due to lightning strikes
Note
The requirements of EN61000
when a Blitzductor is used with 24 VDC:
BVT AVD 24
type no. 918 422
Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans
Supply voltage
WARNING
Safety extra low voltage
WARNING
Transient overvoltages
5.1 Lightning protection, power supply and grounding
-free lightning protector LP798-2N.
-1N can be used.
Installing this lightning protector between an antenna and a SCALANCE W700 is not
adequate protection against a lightning strike. The LP798-1N lightening protector only
works within the framework of a comprehensive lightning protection concept. If you have
questions, ask a qualified specialist company.
-4-5, surge immunity tests on power supply lines, are met only
Dehn Str. 1, Postfach 1640, D -
92306 Neumarkt, Germany
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 / EN
60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power
supply unit for the equipment power supply must comply with NEC Class 2, as described by
the National Electrical Code (r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
5.1 Lightning protection, power supply and grounding
When using outdoor antennas, the shared or even grounded pin of the circuit must be
connected to the shield of the coaxial cable and with all touchable conductive parts and
circuits. Otherwise, in the event of a fault there may be illegally high voltages on touchable
parts.
To fully eliminate the influence of electromagnetic interference, the device must be
grounded. There must be no potential difference between the following parts, otherwise the
device or other connected device could be severely damaged:
• Housing of the SCALANCE W700 and the ground potential of the antenna.
• Housing of the SCALANCE W700 and the ground potential of a device connected over
Ethernet.
• Housing of the SCALANCE W700 and the shield contact of the connected Ethernet
cable.
Connect both grounds to the same foundation earth or use an equipotential bonding cable.
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2 OR ZONE 2.
DO NOT OPEN WHEN ENERGIZED.
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR
COMBUSTIBLE ATMOSPHERE IS PRESENT.
To ensure dielectric strength according to IEEE 802.3, the supplying 24 V power supply unit
must be galvanically isolated with a dielectric strength of 1500 VAC. The galvanic isolation
must also not be bridged by other devices connected to the same power supply unit.
SCALANCE W774/W734 RJ-45
Pin
Assignment
L1+
24 VDC
M1
Ground
M2
Ground
L2+
24 VDC
5.2 Power supply
For the power supply, there are two options with the SCALANCE W774/W734:
● Direct feed in via the four-pin socket (position
①)
● Power over Ethernet via the RJ-45 Ethernet interface P2 (position
Ethernet interface P1 is not capable of PoE.
The four-pin connecting socket has the following pin assignment:
For the power supply, there are two options with the SCALANCE W774 M12 EEC:
● Direct feed in via the four-pin M12 socket (position
①)
● Power over Ethernet via the M12 Ethernet interface P2 (position
interface P1 is not capable of PoE.
The four-pin M12 socket has the following pin assignment:
②). The other Ethernet
1 L1+ 24 VDC
The two following variants are available for power supply via an Ethernet cable:
●
On an 8-wire Fast Ethernet cable, the power is supplied via the free data wires 4, 5, 7
and 8. This corresponds to alternative B according to IEEE 802.3af.
●
The power supply is known as phantom power via the wire pairs carrying signals (1/2 and
3/6).
Before you pull a plug via which the device is supplied with power using PoE, disable the
relevant PoE power supply.
Note
"Phantom power" only with SCALANCE W774 M12 EEC
The SCALANCE W774 M12 EEC device only supports the standard IEEE 802.3 at type 2.
With this device, the attachment to Ethernet is only possible using four
reason, no PSE (Power Sourcing Equipment
the free wire pairs.
Ethernet cables with M12 connectors for the SCALANCE W788
eight
Note
No power sourcing equipment (PSE)
The
devices.
5.2 Power supply
The SCALANCE W774/W734 RJ-45 devices support the standards IEEE 802.3at type 1
(IEEE 802.3af ) and IEEE 802.3.at type 2.
-wire cables. For this
) can be used that only supplies the power via
-x M12 (Gigabit Ethernet,
-wire) cannot be used for the SCALANCE W774 M12 EEC.
SCALANCE W774/W734 devices cannot be used as a PoE power supply for other
Ethernet interface P2
The power can also be supplied via this interface (Power over Ethernet).
5.3 Ethernet
The SCALANCE W774/W734 devices have two Ethernet interfaces located on the underside
of the device. Depending on the version, either RJ-45 or M12 sockets are available.
The SCALANCE W774/W734 has two antenna connectors of the type R-SMA located on the
top of the device.
Follow the steps below to connect a cable for an external antenna to a SCALANCE
W774/734:
1. Insert the connector on the antenna cable into the R-SMA socket and tighten the sleeve
nut on the socket (key size SW8, tightening torque 0.6 Nm). If you only use one antenna,
you need to connect this to the device via antenna connector R1 A1 (position
2. Screw a terminating resistor to the unused antenna socket R1 R2 (position
only using one antenna.
Within the area of authority of the NEC and CEC, the SCALANCE W770/W730 devices and
the antennas connected to them may only be used in a closed building. For this reason, do
not lead antennas into the outdoor area if you need to meet UL requirements.
When installing the SCALANCE W770/W730 in a cabinet, you need
antennas. Suitable connecting cable for a connection between SCALANCE W770/W730 and
a detached antenna are available from SIMATIC NET. You will find detailed information in
the following section.
5.6
Suitable antenna cables and antennas
N-Connect/R-SMA connecting cable
Length
Order number
10 m
6XV1875-5CN10
Suitable antennas
Note
When you select an antenna, keep in mind the national approvals for your device.
Type
Properties
Order number
2.4 GHz, N-Connect female
5 GHz, 2 x N-Connect female
5 GHz, 2 x N-Connect female
4.9 GHz and 5 GHz, N-Connect female
2.4 GHz and 5 GHz, N-Connect female
5.6 Suitable antenna cables and antennas
to use detached
To connect an antenna with an N-Connector, the following cables are suitable:
0.3 m
1 m
2 m
5 m
ANT792-6MN Omni antenna, mast/wall mounting, 6 dBi
ANT793-6MN Omni antenna, mast/wall mounting, 5 dBi
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
5.7 Replacing the PLUG (C-PLUG or KEY-PLUG)
If a new C-PLUG or KEY-PLUG with a valid license is inserted in a SCALANCE W786, the
configuration stored locally on the device is saved on the PLUG.
If an incorrect PLUG, for example from another product or a damaged plug is inserted, the
device signals an error with the red LED. The user then has the choice of either removing
the PLUG again or selecting the option to reformat the PLUG.
In terms of the PLUG, the WLAN devices work in two modes:
● Without PLUG
The device stores the configuration in internal memory. This mode is active when no
PLUG is inserted.
● With PLUG
The configuration stored on the PLUG is displayed over the user interfaces. If changes
are made to the configuration, the device stores the configuration directly on the PLUG
and in the internal memory. This mode is active as soon as a PLUG is inserted. As soon
as the device is started with a PLUG inserted, the SCALANCE W700 starts up with the
configuration data on the PLUG.
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is inserted at one second intervals. If it is
detected that the PLUG was removed, there is a restart.
If a KEY-PLUG was inserted in the device, the device changes to a defined error state
following the restart. With SCALANCE W, the available wireless interfaces are deactivated
in this case.
Figure 5-1 Position of the slot for PLUG on the top of the SCALANCE W774/734
Follow the steps below to remove a PLUG from the device:
1. Turn off the power to the device.
2. Release the screw slot cover (position
3. Insert a screwdriver between the front edge of the PLUG (Position
4. Remove the PLUG from the slot.
5. Screw the cover back onto the device.
Follow the steps below to insert a PLUG in the device:
1. Turn off the power to the device.
2. Release the screw slot cover (position
3. The housing of the PLUG has a protruding ridge on the long side (position
①) and swing the slot cover to the side (position
②).
③) and the slot and
release the PLUG.
①) and swing the slot cover to the side (position
②).
④). The slot
has a groove at this position. Insert the PLUG correctly oriented into the slot. The PLUG
is correctly inserted when it is completely inside the device and does not jut out of the
slot.
A C-PLUG only stores information about the configuration of a device. In addition to the
configuration, a KEY-PLUG also contains a license with which you can enable special
functions, for example iFeatures:
*) The PoE class depends on the hardware version of the device. Devices with a hardware
version ≥ 3 have PoE class 2. Devices with a lower hardware version have PoE class 3.
Ambient temperature During operation with the rack in-
24 VDC Safe Extra Low Voltage (SELV)
• 19.2 to 28.8 VDC
• 16.8... 31.2 VDC (UL approvals only
valid for 19.2 ... 28.8 VDC)
-20 ℃ to +60 ℃
During operation with the rack in-
During storage -40 ℃ to +85 ℃
During transportation -40 ℃ to +85 ℃
Relative humidity During operation ≤ 95% at 25 °C, no condensation
Operating altitude During operation ≤ 2,000 m above sea level at max. 60 °C
Contaminant concentration According to IEC 60721
Dimensions (W x H x D) 26 x 156 x 127 mm
Installation options
• Wall mounting
• Installation on a DIN rail
• Installation on an S7-300 standard rail
• Installation on an S7-1500 standard rail
-20 ℃ to +60 ℃
ambient temperature
*) The PoE class depends on the hardware version of the device. Devices with a hardware
version ≥ 2 have PoE class 2. Devices with a lower hardware version have PoE class 3.
You will find the approvals of the products in the reference work "Approvals SCALANCE
W700 802.11n" on the Internet pages of Siemens Industry Online Support: