Siemens ELN1V1 Operating Instructions

SCALANCE W760/W720

___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC NET
Operating Instructions
03/2015
C79000
Information on the Internet
1
Introduction
2
Description
3
Mounting
4
Connection
5
Technical data
6
Dimension drawings
7
Approvals
8
-G8976-C322-05
Siemens AG Division Process Industries and Drives Postfach 48 48 9 GERMANY
C79000-G8976-C322-05
Copyright © Siemens AG 2014 - 2015. All rights reserved

Legal information

Warning notice system
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
Qualified Personnel
personnel qualified
Proper use of Siemens products
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
Disclaimer of Liability
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
The product/system described in this documentation may be operated only by task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Note the following:
documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
for the specific
0026 NÜRNBERG
05/2016 Subject to change

Contents

1 Information on the Internet ...................................................................................................................... 5
2 Introduction ............................................................................................................................................. 7
3 Description .............................................................................................................................................. 9
4 Mounting ............................................................................................................................................... 13
5 Connection ........................................................................................................................................... 15
6 Technical data ...................................................................................................................................... 25
7 Dimension drawings .............................................................................................................................. 27
8 Approvals .............................................................................................................................................. 29
Index..................................................................................................................................................... 31
2.1 Information on the Operating Instructions ................................................................................ 7
2.2 Structure of the type designation .............................................................................................. 8
2.3 Security information .................................................................................................................. 8
3.1 Components of the product ...................................................................................................... 9
3.2 LED display ............................................................................................................................... 9
3.3 Reset button ............................................................................................................................ 11
4.1 Installing on a DIN rail / removing ........................................................................................... 14
5.1 Lightning protection, power supply and grounding ................................................................. 15
5.2 Power supply .......................................................................................................................... 19
5.3 Ethernet .................................................................................................................................. 20
5.4 Suitable cables for power supply and Ethernet ...................................................................... 20
5.5 Antenna connector .................................................................................................................. 21
5.6 Suitable antenna cables and antennas ................................................................................... 22
6.1 Technical specifications W761/W722/W721 RJ-45 ................................................................ 25
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
3
1
Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Kompaktbetriebsanleitung in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.com/ww/view/lu/10806097
Please observe the warnings and additional information in the compact operating instructions in your language in the Internet: http://support.automation.siemens.com/ww/view/au/10806097 http://support.automation.siemens.com/ww/view/ca/10806097 http://support.automation.siemens.com/ww/view/gb/10806097 http://support.automation.siemens.com/ww/view/ie/10806097 http://support.automation.siemens.com/ww/view/us/10806097 http://support.automation.siemens.com/ww/view/za/10806097
Veuillez tenir compte des avertissements et informations supplémentaires de la notice de service dans votre langue sur Internet: http://support.automation.siemens.com/ww/view/be/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/fr/10806097 http://support.automation.siemens.com/ww/view/lu/10806097
Si prega di tenere conto delle avvertenze e ulteriori informazioni nell’istruzione operativa compatta nella relativa lingua in Internet: http://support.automation.siemens.com/ww/view/it/10806097
Se ruega tener en cuenta las advertencias y las informaciones complementarias contenidas en las instrucciones de servicio (resumen) en español en Internet: http://support.automation.siemens.com/ww/view/cl/10806097 http://support.automation.siemens.com/ww/view/es/10806097
Dbejte prosím na výstražné pokyny a doplňkové informace v kompaktním návodu k obsluze
ve vašem jazyce na internetu: http://support.automation.siemens.com/ww/view/cz/10806097
Vær venligst opmærksom på de advarselsanvisninger og ekstra informationer der findes på dit sprog i kompaktdriftsvejledningen på internettet: http://support.automation.siemens.com/ww/view/dk/10806097
Noudata lyhyen käyttöoppaan sisältämiä varoituksia ja huomio sen muutkin tiedot. Oman kielisesi käyttöoppaan löydät internetistä osoitteesta: http://support.automation.siemens.com/ww/view/fi/10806097
Λάβετε υπόψη τις υποδείξεις προειδοποίησης και τις πρόσθετες πληροφορίες των συνοπτικών οδηγιών χρήσης που παρέχονται στη γλώσσα σας στο Διαδίκτυο:
http://support.automation.siemens.com/ww/view/gr/10806097
请注意互联网上精编版操作说明相应语言版本中的警告提示和附加信息: http://support.automation.siemens.com/ww/view/cn/10806097
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
5
Information on the Internet
http://support.automation.siemens.com/ww/view/hk/10806097 http://support.automation.siemens.com/ww/view/sg/10806097
Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt használati útmutatóban található figyelmeztetéseket és további információkat:
http://support.automation.siemens.com/ww/view/hu/10806097
Skoðið vel viðvaranir og aðrar upplýsingar í notkunarleiðbeiningunum á ykkar tungumáli á
internetinu: http://support.automation.siemens.com/ww/view/is/10806097
インターネットサイトにある各言語の注意事項および追加情報を参照してください: http://support.automation.siemens.com/ww/view/jp/10806097
사이트에 있는 귀하의 언어로 된 콤팩트 사용 설명서에 명시된 경고 지침 및 추가 정보를 준수하십시오:
http://support.automation.siemens.com/ww/view/kr/10806097
http://support.automation.siemens.com/ww/view/kw/10806097
Neem goed nota van de waarschuwingen en extra informatie in de compacte gebruiksaanwijzing in uw taal op internet: http://support.automation.siemens.com/ww/view/be/10806097 http://support.automation.siemens.com/ww/view/nl/10806097
Vennligst følg advarslene og annen informasjon i den kompakte bruksanvisningen, som du finner på ditt språk på internett: http://support.automation.siemens.com/ww/view/no/10806097
Proszę zwrócić uwagę na ostrzeżenia oraz dodatkowe informacje w kompaktowej instrukcji obsługi, dostępnej w odpowiednim języku w internecie:
http://support.automation.siemens.com/ww/view/po/10806097
Observera varningshänvisningarna och extrainformationerna i kompaktbruksanvisningen som finns på ditt språk på internet: http://support.automation.siemens.com/ww/view/se/10806097
İnternette kendi dilinizdeki kompakt işletim kılavuzunda yer alan uyarı notlarına ve ek
bilgilere lütfen dikkat edin:
http://support.automation.siemens.com/ww/view/tr/10806097
SCALANCE W760/W720
6 Operating Instructions, 03/2015, C79000-G8976-C322-05
2
2.1

Information on the Operating Instructions

Validity of the Operating Instructions
Article no. of the RoW version
Article no. of the US version
Access point
SCALANCE W761-1 RJ-45
6GK5761-1FC00-0AA0
6GK5761-1FC00-0AB0
Ethernet client modules
(iFeatures)
SCALANCE W721-1 RJ-45
6GK5721-1FC00-0AA0
6GK5721-1FC00-0AB0
Purpose of the Operating Instructions
Documentation on the accompanying CD
PH_SCALANCE-W760-W720-WBM_76.pdf and PH_SCALANCE-W760-W720-CLI_76.pdf
Note
Make sure that you read the explanations and instructions in the
License conditions
Note Open source software
Read the license conditions for open source software carefully before using the product.
These operating instructions cover the following products:
SCALANCE W722-1 RJ-45
These operating instructions apply to the following software version:
6GK5722-1FC00-0AA0 6GK5722-1FC00-0AB0
SCALANCE W760/W720 with firmware as of Version 5.2
Using the Operating Instructions, you will be able to install and connect the SCALANCE W760/W720 correctly. The configuration and the integration of the device in a WLAN are not described in these instructions.
You will find detailed information about configuration in the SCALANCE W700 configuration manuals on the accompanying SIMATIC NET IWLAN CD under the file name:
README.txt file
You will find license conditions in the following documents on the supplied data medium:
● DOC_License_74.pdf
● DOC_LicenseScalanceW_76.htm
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
7
Introduction
2.2
Structure of the type designation
2.3

Security information

2.2 Structure of the type designation

The type designation of the device is made up of several parts that have the following meaning:
Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development. We therefore recommend that you keep yourself informed with respect to our product updates. Please find further information and newsletters on this subject at: http://support.automation.siemens.com.
To ensure the secure operation of a plant or machine it is also necessary to take suitable preventive action (e.g. cell protection concept) and to integrate the automation and drive components into a state-of-the-art holistic industrial security concept for the entire plant or machine. Any third-party products that may be in use must also be taken into account. Please find further information at: http://www.siemens.com/industrialsecurity
SCALANCE W760/W720
8 Operating Instructions, 03/2015, C79000-G8976-C322-05

Description

3
3.1
Components of the product
3.2

LED display

Information on operating status and data transfer

3.1 Components of the product

The following components are supplied with the product:
SCALANCE W761 or SCALANCE W722 or SCALANCE W721
● 1 protective cap for the antenna socket
● 1 connector for the power supply
● SIMATIC NET Industrial Wireless LAN CD
Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office.
On the front of the housing, several LEDs provide information on the operating status of the device:
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
9
Description
LED
Color
Meaning
L1
Green
Power supply L1.
alternately
There is a connection via the WLAN interface.
alternately
the "MAC mode" parameter and is connected to no access point.
short, 1 x long
the "MAC mode" parameter and is connected to an access point.
Red
An error occurred during operation with the device.
time
R1
Note Primary user (radar) on all enabled channels (only when DFS is enabled)
If the device detects a primary user (for example radar signals) on all enabled channels of the WLAN interface, the LED F next 30 minutes. After this time, the device runs the scan again and c primary user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be shortened even by restarting the device.
3.2 LED display
P1 Green There is a connection via the Ethernet interface (Link).
Green and yel­low flashing
Data transfer via the Ethernet interface.
R1 Green
Green and yel­low flashing
Green flashing briefly
Green flashing 3 x
F
Red R1 flashing yel­low at the same
P1
Flashing yellow "Flashing" enabled using SIMATIC NET Primary Setup Tool (PST).
SCALANCE W760 in access point mode:
The WLAN interface is initialized and ready for operation.
SCALANCE W760 in client mode or SCALANCE W720:
Data transfer over the WLAN interface.
SCALANCE W760 in access point mode:
With 802.11h, the channel is scanned for one minute for primary users before the channel can be used for data traffic.
SCALANCE W760 in client mode or SCALANCE W720:
The client waits for the MAC address due to the setting "Automatic" for
SCALANCE W760 in client mode or SCALANCE W720:
The client waits for the MAC address due to the setting "Automatic" for
A primary user was detected on all enabled channels. (only when DFS is enabled or according to IEEE 802.11h)
is lit and R1 flashes. No data traffic is then possible for the
SCALANCE W760/W720
10 Operating Instructions, 03/2015, C79000-G8976-C322-05
hecks whether a
Description
3.3
Reset button
Functions of the reset button
Note
If you make changes to the configuration and restart immediately afterwards with the reset button, the changes may be lost. If you restart the device using the WBM (menu command "System > Restart") or using the CLI (command "restart" in the EXEC Modus), the configuration changes are always retained.

3.3 Reset button

The reset button (position ) is on the front of the housing:
The reset button has the following functions:
● Restart of the device
● Loading new firmware
● Restoring the default parameters (factory defaults)
You will find more detailed information in the configuration manual SCALANCE W760/W720 WBM.
Privileged
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
11
4
CAUTION
Minimum distance to antennas
WARNING
WARNING
General notes on use according to ATEX and IECEx
WARNING
Fit the device so that there is a minimum clearance of 20 cm between antennas and persons.
If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.
When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529.
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
13
Mounting
4.1
Installing on a DIN rail / removing
Procedure for installation
Procedure when removing

4.1 Installing on a DIN rail / removing

Follow the steps below to fit the SCALANCE W760/W720 to a DIN rail:
1. Place the device on the upper edge of the DIN rail as shown in the figure.
2. Press the device against the DIN rail until the DIN rail slider catch locks in place.
Follow the steps below to remove the SCALANCE W760/W720 from a DIN rail:
1. Press the release button on the top of the device to release the DIN rail catch.
2. Tilt the SCALANCE W760/W720 forward and remove the device from the DIN rail.
SCALANCE W760/W720
14 Operating Instructions, 03/2015, C79000-G8976-C322-05
5
5.1

Lightning protection, power supply and grounding

Lightning protection
WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.
Suitable lightning protectors are available in the range of accessories of SIMATIC NET Industrial WLAN:
Lightning protector LP798-1N (order no. 6GK5798-2LP00-2AA6)
Lightning protector LP798-2N (order no. 6GK5798-2LP10-2AA6)
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
15
Connection
Note
We recommend that you use the maintenance
Exception: When there is also DC power supplied via the antenna the lightning protector LP798
WARNING
Danger due to lightning strikes
Note
The requirements of EN61000
are met only
when a Blitzductor is used with 24 VDC:
BVT AVD 24 type no. 918 422
Manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans
Supply voltage
WARNING
Safety extra low voltage
WARNING
Transient overvoltages
5.1 Lightning protection, power supply and grounding
-free lightning protector LP798-2N.
cable. In this case, only
-1N can be used.
Installing this lightning protector between an antenna and a SCALANCE W700 is not adequate protection against a lightning strike. The LP798-1N lightening protector only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company.
-4-5, surge immunity tests on power supply lines,
Dehn Str. 1, Postfach 1640, D -
92306 Neumarkt, Germany
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS).
This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements.
Take measures to prevent transient voltage surges of more than 40% of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage).
SCALANCE W760/W720
16 Operating Instructions, 03/2015, C79000-G8976-C322-05
Connection
Grounding
WARNING
Danger to life from overvoltage, fire hazard
NOTICE
Damage to the device due to potential differences
WARNING
EXPLOSION HAZARD
WARNING
EXPLOSION HAZARD
General notes on use according to ATEX and IECEx
WARNING
EXPLOSION HAZARD
5.1 Lightning protection, power supply and grounding
When using outdoor antennas, the shared or even grounded pin of the circuit must be connected to the shield of the coaxial cable and with all touchable conductive parts and circuits. Otherwise, in the event of a fault there may be illegally high voltages on touchable parts.
To fully eliminate the influence of electromagnetic interference, the device must be grounded. There must be no potential difference between the following parts, otherwise the device or other connected device could be severely damaged:
• Grounding pin of the SCALANCE W700 and the ground potential of the antenna.
Grounding pin of the SCALANCE W700 and the ground potential of a device connected
over Ethernet.
Grounding pin of the SCALANCE W700 and the shield contact of the connected Ethernet cable.
Connect both grounds to the same foundation earth or use an equipotential bonding cable.
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2.
DO NOT OPEN WHEN ENERGIZED.
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
17
Connection
General notes on use in hazardous areas according to UL-HazLoc
WARNING
EXPLOSION HAZARD
5.1 Lightning protection, power supply and grounding
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non­hazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only.
SCALANCE W760/W720
18 Operating Instructions, 03/2015, C79000-G8976-C322-05
Connection
5.2
Power supply
Socket
Pin
Assignment
L+
+24 VDC
M
Ground

5.2 Power supply

The power is supplied to the SCALANCE W760/W720 via the three-pin socket.
The three-pin socket has the following pin assignment:
Grounding
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
19
Connection
5.3
Ethernet
5.4

Suitable cables for power supply and Ethernet

Cable specification
Application
Specification
have this approval)

5.3 Ethernet

The SCALANCE W760/W720 has two Ethernet interfaces located on the underside of the device (position
①).
The following table lists the requirements for a cable depending on the application.
Direct 24 VDC supply
Ethernet
Round cable cross-section with 6 to 8 mm diameter. Two-wire cable with 0.5 to 1.5 mm per wire.
Permitted tensile load at least 100 N.
UL listing: Type PLTC or ITC
1. IE FC TP standard cable GP 2 x 2 (type A) Order no.: 6XV1 840-2AH10
2. IE TP torsion cable 2 x 2 (type C) Order no.: 6XV1 870-2F
3. IE FC TP trailing cable 2 x 2 (type C) Order no.: 6XV1 840 3AH10
UL listing: Type PLTC or ITC (the three named types
2
cross-section
SCALANCE W760/W720
20 Operating Instructions, 03/2015, C79000-G8976-C322-05
Connection
5.5
Antenna connector
Procedure
Note Cabinet installation
When antenna. Suitable connecting cables for a connection between SCALANCE W760/720 and a detached antenna are available from SIMATIC NET. You will find detailed information in the follow

5.5 Antenna connector

The SCALANCE W760/W720 has an antenna connector R1 A1 of the type R-SMA located on the front of the device (position
①).
Follow the steps below to connect a cable for an external antenna to a SCALANCE W760/720:
1. Insert the connector on the antenna cable into the R-SMA socket R1 A1 (position tighten the retainer nut on the socket (key size SW8, tightening torque 0.6 Nm).
installing the SCALANCE W760/720 in a cabinet, you need to use a detached
ing section.
) and
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
21
Connection
5.6
Suitable antenna cables and antennas
N-Connect/R-SMA connecting cable
Length
Order number
10 m
6XV1875-5CN10
Suitable antennas
Note
When you select an antenna, keep in mind the national approvals for your device.
Type
Properties
Order number
2.4 GHz, N-Connect female
5 GHz, N-Connect female
5 GHz, 2 x N-Connect female
4.9 GHz and 5 GHz, N-Connect female
2.4 GHz and 5 GHz, N-Connect female
5 GHz, 2 x N-Connect female
2.4 GHz and 5 GHz, N-Connect female
connector.

5.6 Suitable antenna cables and antennas

To connect an antenna with an N-Connector, the following cables are suitable:
0.3 m 1 m 2 m 5 m
ANT792-6MN Omni antenna, mast/wall mounting, 6 dBi
ANT793-6MN Omni antenna, mast/wall mounting, 5 dBi
ANT793-8DJ Directional antenna, mast/wall mounting,
18 dBi 5 GHz, 2 x N-Connect female
ANT793-8DK Directional antenna, mast/wall mounting,
23 dBi
6XV1875-5CE30 6XV1875-5CH10 6XV1875-5CH20 6XV1875-5CH50
6GK5 792-6MN00-0AA6
6GK5 793-6MN00-0AA6
6GK5 793-8DJ00-0AA0
6GK5 793-8DK00-0AA0
ANT793-8DP Directional antenna, mast/wall mounting,
13 / 13.5 dBi
ANT795-6DC Wide angle antenna, mast/
wall mounting, 9 dBi
ANT793-6DG Wide angle antenna, mast/
wall mounting, 9 dBi
ANT795-6MN Omni antenna, mounted on roof/vehicle,
6/8 dBi
ANT795-4MC Omnidirectional antenna, 3/5 dBi, 2.4 GHz
and 5 GHz, IP65, N-Connect male for direct installation on the device, straight
SCALANCE W760/W720
22 Operating Instructions, 03/2015, C79000-G8976-C322-05
6GK5793-8DP00-0AA0
6GK5 795-6DC00-0AA0
6GK5 793-6DG00-0AA0
6GK5 795-6MN10-0AA6
6GK5 795-4MC00-0AA3
Connection
180°.
tion, 4 dBi, 2.4 GHz, N-connect female.
tion, 6 dBi, 5 GHz, N-connect female.
Omni Antenna, 2/2,5 dBi, 2,4 GHz and 5GHz, IP69K, N-Connect male
Omni Antenna 5/7 dBi, 2,4 GHz and 5GHz, IP67, N-Connect female
Omni Antenna for Mobile Wireless, WLAN and GPS, WLAN: 6/7 dBi, 2,4 GHz and
Connect female,
Port 2
Directional Antenna, 5 GHz, 14dBi, IP66, 2xN-Connect female
GHz PE 1/2"
2.400 - 2.485 GHz, N-Connect female.
GHz PE 1/2"
5.150 - 5.875 GHz, N-Connect female.
NOTICE
ANT795-4MA
Note ANT793-8DJ
The antenna ANT793 length) or 6XV1875
Notice for USA/Canada
Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2).
5.6 Suitable antenna cables and antennas
ANT795-4MD Omnidirectional antenna, 3/5 dBi, 2.4 GHz
and 5 GHz, IP65, N-Connect male for direct installation on the device, 90° con­nector.
ANT795-4MA Omni antenna, directly on the device, 3/5
dBi
2.4 GHz and 5 GHz, IP30, R-SMA con­nector male for direct mounting on the device, connector angle adjustable 0° to
ANT792-4DN RCoax helical antenna, circular polariza-
ANT793-4MN RCoax λ5/8 antenna with vertical polariza-
ANT795-4MX
ANT795-6MP
ANT896-6MM
5GHz, IP68, IP69 K, QMA-
ANT793-8DL
6GK5 795-4MD00-0AA3
6GK5 795-4MA00-0AA3
6GK5 792-4DN00-0AA6
6GK5 793-4MN00-0AA6
6GK5795-4MX00-0AA0
6GK5795-6MP00-0AA0
6GK5896-6MM00-0AA0
6GK5793-8DL00-0AA0
IWLAN RCoax cable 2.4
IWLAN RCoax cable 5
Omni antenna, 0 dBi
Omni antenna, 0 dBi
6XV1875-2A
6XV1875-2D
The ANT795-4MA antenna has degree of protection IP30 and is therefore suitable for dry environments.
-8DJ may only be used with the antenna cable 6XV1875-5CH50 (5 m
-5CN10 (10 m length). Other antenna cables are not permitted.
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
23
Connection
Note ANT793-8DK
The antenna ANT793
5CN10 (10 m
length). Other antenna
Notice for USA/Canada
Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2).
5.6 Suitable antenna cables and antennas
-8DK may only be used with the antenna cable 6XV1875­cables are not permitted.
SCALANCE W760/W720
24 Operating Instructions, 03/2015, C79000-G8976-C322-05
6
6.1

Technical specifications W761/W722/W721 RJ-45

Note
You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W760/W720" on the supplied data medium (REF_W760
SCALANCE W761/W722/W721
Data transfer
Ethernet transfer rate
10 / 100 Mbps
Wireless transmission rate
1 ... 150 Mbps
IEEE 802.11n
Attachment to Industrial Ethernet
Quantity
1
Design
RJ-45 jack
Properties
Half duplex/full duplex, autocrossover, autonegotiation, autosensing, floating
Permitted cable lengths (Ethernet)
(Alternative combinations per length range)
The following technical specifications apply to the following devices:
SCALANCE W761-1 RJ-45
SCALANCE W722-1 RJ-45
SCALANCE W721-1 RJ-45
-RadioInterface.pdf).
Wireless standards supported IEEE 802.11a
IEEE 802.11b IEEE 802.11g
0 ... 55 m
Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180
Max. 45 m IE TP Torsion Cable with IE FC RJ45 + 10 m TP Cord via
IE FC RJ45 Outlet
0 ... 85 m
0 ... 100 m
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
Max. 85 m IE FC TP Marine/Trailing/Flexible/FRNC/Festoon/Food Cable with IE FC RJ45 Plug 180
Max. 75 m IE FC TP Marine/Trailing/Flexible/FRNC/Festoon/Food Cable + 10 m TP Cord via IE FC RJ45 Outlet
Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180
Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet
25
Technical data
SCALANCE W761/W722/W721
Wireless interface
Quantity
1
Design
R-SMA female
Impedance
50 Ω nominal
4920 ... 5875 MHz
Electrical data
Supply voltage
24 VDC Safe Extra Low Voltage (SELV)
Permitted range
19.2 to 28.8 VDC
Design
Terminal block, 3 terminals
Fusing
2.5 A / 24 VDC
Current consumption
Typical
150 mA
Power loss at 24 VDC
Typical
3.6 W
Permitted ambient conditions
stalled horizontally
stalled vertically
During storage
-40 ℃ to +85 ℃
During transportation
-40 ℃ to +85 ℃
Relative humidity
During operation
≤ 95% at 25 °C, no condensation
Design, dimensions and weight
Degree of protection
IP20
Weight
130 g
Dimensions (W x H x D)
50 x 114 x 74 mm
Installation options
Installation on a DIN rail
Mean time between failure (MTBF)
at 40 °C ambient temperature
106.51 years
6.1 Technical specifications W761/W722/W721 RJ-45
Antenna connector
Frequency range 2412 ... 2480 MHz
Power supply
Ambient temperature During operation with the rack in-
During operation with the rack in-
Operating altitude During operation 2,000 m above sea level at max. 55 °C
Contaminant concentration According to IEC 60721
0 ℃ to +55 ℃
0 ℃ to +55 ℃
ambient temperature
SCALANCE W760/W720
26 Operating Instructions, 03/2015, C79000-G8976-C322-05
7
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
27
8
You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support:
Using the search function:
support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en)
Enter the entry ID of the relevant manual as the search item.
In the navigation panel on the left-hand side in the area "Industrial Communication":
Industrial communication (http://support.automation.siemens.com/WW/view/en/10805878/133300)
Go to the required product group and make the following settings:
"Entry list" tab, Entry type "Manuals / Operating Instructions"
You will find the documentation for the SIMATIC NET products relevant here on the data storage medium that ships with some products:
● Product CD / product DVD
● SIMATIC NET Manual Collection
● SIMATIC NET IWLAN CD
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
29
A
C
D
E
G
I
L
P
R
S
T
Antenna
Connector, 21
Antennas
Specification, 22
Article numbers, 7
Cables
Specification, 20, 22
Connectors, 9
Dimension drawing, 27 Documentation on the CD, 7
Ethernet interface, 20
Reset button, 11 Resetting the device, 11 Restart of the device, 11
Safety extra low voltage, 16 Scope of delivery, 9 Supply voltage, 16
Technical specifications, 25 Type designation, 8
Grounding, 15
Installation
DIN rail, 14
Interfaces, 25
LED display, 9 Lightning protection, 15 Loading firmware, 11
Primary user (radar), 9 Protective cap, 9
SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05
31
Index
SCALANCE W760/W720
32 Operating Instructions, 03/2015, C79000-G8976-C322-05
Loading...