SIEMENS CF75, CF76 Service Repair Documentation Level 2.5

Page 1
Company Confidential s Com
Copyright 2005© Siemens AG
Service Repair Documentation
Release Date Department Notes to change
1.0 02.08.2005 ICM MP CC GRM T New document
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page 1 of 9
Page 2
Company Confidential s Com
Copyright 2005© Siemens AG
Introduction
This Service Repair Documentation is intended to carry out repairs on Siemens repair level
2.5Light. The described failures shall be repaired in Siemens authorized local workshops only.
The level 2.5light (former Level 2.5 ) partners are obliged to repair boards, up to their repair level, under consideration of the information given by level 2.5Light (former level 2.5) repair instruction.
All repairs have to be carried out in an ESD protected environment and with ESD protected equipment/tools. For all activities the international ESD regulations have to be considered.
Assembling/disassembling has to be done according to the latest CF75, CF76 Level 2 repair documentation. It has to be ensured that every repaired mobile Phone is checked according to the latest released General Test Instruction document (both documents are available in the Technical Support section of the C-market).
Check at least weekly C-market for updates and consider all CF75, CF76 related Customer Care Information
CF75 Partnumber on IMEI label: S30880-S6010-#xxx CF76 Partnumber on IMEI label: S30880-S6090-#xxx
, while # may be any letter (A-Z) and xxx may be any number from 100, 101, 102....
Scrap Handling: All Scrap information given in this manual are related to the SCRAP-Rules and instructions.
Attention: - Consider the new "LEAD-FREE" soldering rules (available in the
communication market)
- Avoid excessive heat.
If you have any questions regarding the repair procedures or technical questions do not hesitate to contact our technical support team in Kamp-Lintfort, Germany:
Tel.: +49 2842 95 4666 Fax: +49 2842 95 4302 E-mail: st-support@siemens.com
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page 2 of 9
Page 3
Company Confidential s Com
Copyright 2005© Siemens AG
Table of Content
1 CF75, CF76 board layout ..............................................................................................................4
2 Connector SIM Card Reader .........................................................................................................5
3 Connector IO Jack.........................................................................................................................6
4 Connector Board to Board.............................................................................................................7
5 Connector Battery .........................................................................................................................8
6 IRDA..............................................................................................................................................9
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page 3 of 9
Page 4
Company Confidential s Com
Copyright 2005© Siemens AG
1 CF75, CF76 board layout
Jigs, Tools and Working materials for all described repairs:
- hot air blower
- soldering gun
- tweezers
- flux
- solder
Connector BOARD TO BOARD
IRDA
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Connector SIM CARD READER
Connector BATTERY
Page
4 of 9
Connector IO JACK
Page 5
Company Confidential s Com
Copyright 2005© Siemens AG
2 Connector SIM Card Reader
okay
okay
not okay
SCRAP has to be
send separately to
WSC
- check for twisted or bended contacts
- check for dry joints
okay
Level 2 Repair
Fault Symptoms
Customer: GRT:
Handset does not accept SIM card SIM Card Problems
SIM Card Problems
Watch for oxidation and damaged pads of the SIM card reader
not okay
Check the status of the SIM card reader visually
Exchange SIM Card reader
not okay
Use the resistor test function of a multimeter to check connection between spring contacts and soldering contacts. The value must be ~0

Connector SIM Card Reader

Use soldering iron to remove defective component. Avoid excessive heat! Watch surrounding components! Resolder new component afterwards.
E-commerce order number: L50634-Z97-C406 E-commerce order name: CONNECTOR SIM CARD READER R65 (B) Soldering temperature: ~ 360°C Tip Temp. IRIS Diagnose Code: 43300 Interface/SIM Cardreader/Mechanical Damage
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page
5 of 9
Page 6
Company Confidential s Com
Copyright 2005© Siemens AG
3 Connector IO Jack
Fault Symptoms
Customer: GRT:
Charging Problems No connection to GRT Problems with external loudspeaker or microphone when using a car kit Tbd. Problems with accessories connected at the IO connector
IO connector Problems
Watch for oxidation and damaged pads of the IO connector
okay
Check for dust inside the IO connector
not okay
Check the status of the IO connector visually
okay
okay
Exchange IO connector
not okay
Use the resistor test function of a multimeter to check connection between spring contacts and soldering contacts. The value must be ~0
okay

Connector IO Jack

Use soldering iron to remove defective component. Avoid excessive heat! Watch surrounding components! Resolder new component afterwards.
E-commerce order number: L36334-Z93-C303 E-commerce order name: IO-JACK SLIM 12-POL Soldering temperature: ~ 360°C Tip Temp. IRIS Diagnose Code: 46100 Interface/Charging Connector/Mechanical Damage
47300 Interface/Data Interface/Mechanical Damage 4B100 Interface/Headset Connector/Mechanical Damage
not okay
not okay
SCRAP has to be
send separately to
WSC
Clean IO connector
- check for twisted or bended contacts
- check for dry joints
Level 2 Repair
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page
6 of 9
Page 7
Company Confidential s Com
Copyright 2005© Siemens AG
4 Connector Board to Board
Fault Symptoms
Customer: GRT:
Display problems, like missing lines or columns on the LCD or display contrast problems or illumination problems
B to B connector Problems
Watch for oxidation and damaged pads of the BtoB connector
okay
not okay
Check the status of the BtoB connector visually
okay
Exchange BtoB connector
Level 2 Repair

Connector Board to Board

Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components! Resolder new component afterwards.
E-commerce order number: L36334-Z97-C341 E-commerce order name: CONNECTOR BOARD TO BOARD 30-POL Soldering temperature: ~ 360°C TIP Temp. IRIS Diagnose Code: 32100 Keys / Main / No Function
32200 Keys / Main / Reduced Functionality 36000 Keys / Illumination
Display problems
not okay
- check for twisted or
- check for dry joints
SCRAP has to be
send separately to
WSC
bended contacts
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page
7 of 9
Page 8
Company Confidential s Com
Copyright 2005© Siemens AG
5 Connector Battery
okay
okay
not okay
SCRAP has to be
send separately to
WSC
- check for twisted or bended contacts
- check for dry joints
okay
Level 2 Repair
Fault Symptoms
Customer: GRT:
Mobile does not switch on No connection to GRT
Battery connector Problems
Watch for oxidation and damaged pads of the battery connector
not okay
Check the status of the battery connector visually
Exchange Battery connector
not okay
Use the resistor test function of a multimeter to check connection between spring contacts and soldering contacts. The value must be ~0

Connector BATTERY

Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components! Resolder new component afterwards.
E-commerce order number: L36334-Z97-C336 E-commerce order name: CONNECTOR BATTERY 3-POL R65 Soldering temperature: ~ 360°C Tip Temp. IRIS Diagnose Code: 13000 Battery/Mechanical Damage
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page
8 of 9
Page 9
Company Confidential s Com
Copyright 2005© Siemens AG
6 IRDA
okay
okay
not okay
SCRAP has to be
send separately to
- check for dry joints
Fault Symptoms
Customer: GRT:
IRDA does not work Tbd.
IRDA Problems
Watch for oxidation and damaged pads of the IRDA Diode
not okay
Check the status of the IRDA Diode visually
Exchange IRDA Diode
Level 2 Repair
Irda Diode
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components! Resolder new component afterwards.
E-commerce order number: L36197-F5008-F492 E-commerce order name: IRDA 115.2 KBIT Soldering temperature: ~ 360°C Tip Temp. IRIS Diagnose Code: 41100 Interfaces / IRDA / No Function
41300 Interfaces / IRDA / Mechanical Damage
Service Repair Documentation TI_Repair_L2,5L_CF75_CF76_R1.0
Page
9 of 9
Loading...