ARCADIS Avantic
Disposal Instructions
System
SP
Disposal Instructions
10048590
Print No.:
Replaces: n.a.
SPR2-330.861.01.01.02
© Siemens AG
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.
English
Doc. Gen. Date: 02.05
2005

2 Revision / Disclaimer
1Revision / Disclaimer
Document revision level
The document corresponds to the version/revision level effective at the time of system
delivery. Revisions to hardcopy documentation are not automatically distributed.
Please contact your local Siemens office to order current revision levels.
Disclaimer
The installation and service of equipment described herein is to be performed by qualified
personnel who are employed by Siemens or one of its affiliates or who are otherwise
authorized by Siemens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service procedures.
ARCADIS Avantic SPR2-330.861.01.01.02 Siemens AG
02.05 CS SD 24
Page 2 of 8
Medical Solutions

Table of Contents 3
1- 0Table of Contents
1 _______ Environmental Protection Measures ________________________________ 4
Disposal list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 _______ Changes to Previous Version______________________________________ 7
Siemens AG SPR2-330.861.01.01.02 ARCADIS Avantic
Medical Solutions
02.05 CS SD 24
Page 3 of 8

4 Environmental Protection Measures
1Environmental Protection Measures
2-
Disposal list 0
• The items in the following table are to be disposed of by a suitable disposal company.
Compo-
nent/assembly
X-ray tube
assembly
Tube assembly
collimator
33 cm X-ray
image intensifier
Position
C-arm, bottom (1/Fig.1/p.4) Lead oil implosion
C-arm, bottom of the
(2/Fig.1/p.4) Lead 1
X-ray tube assembly
I.I. housing, inserted
(3/Fig.1/p.4) Lead implosion of
in housing
Hazardous mate-
rial/risk
of the X-ray tube
the image intensifier
Quan-
tity
1
1
tube
33 cm X-ray
image intensifier
C-arm, top lead (4/Fig.1/p.4) Lead implosion of
the image intensifier
1
tube
TFT monitor(s) Monitor cart, top (1/Fig.2/p.5) n.a. 1 / 2
PC PC in the monitor cart (1/Fig.3/p.5)
Lithium 2
(2/Fig.2/p.5)
Printer In the monitor cart (3/Fig.2/p.5) n.a. 1
Battery PC (1/Fig.3/p.5) Lithium 1
Battery UPS (4/Fig.2/p.5) Lead 1
Fig. 1: System overview_ARCADIS Avantic
ARCADIS Avantic SPR2-330.861.01.01.02 Siemens AG
02.05 CS SD 24
Page 4 of 8
Medical Solutions

Environmental Protection Measures 5
Fig. 2: Monitor trolley
Fig. 3: PC overview
Pos. Lithium battery
Siemens AG SPR2-330.861.01.01.02 ARCADIS Avantic
Medical Solutions
02.05 CS SD 24
Page 5 of 8

6 Environmental Protection Measures
Fig. 4: View of battery
Pos. Lithium battery
ARCADIS Avantic SPR2-330.861.01.01.02 Siemens AG
02.05 CS SD 24
Page 6 of 8
Medical Solutions

Changes to Previous Version 7
2Changes to Previous Version
3-
n.a., first issue
Siemens AG SPR2-330.861.01.01.02 ARCADIS Avantic
Medical Solutions
02.05 CS SD 24
Page 7 of 8

8 Changes to Previous Version
ARCADIS Avantic SPR2-330.861.01.01.02 Siemens AG
02.05 CS SD 24
Page 8 of 8
Medical Solutions