Warning ............................................................................................................................................................................... 2
Unpack i ng Ins tructi ons ................................................................................................................................................. 2
Safety Instructions ......................................................................................................................................................... 2
Operating Determinations .......................................................................................................................................... 4
Rigging ............................................................................................................................................................................ 4
Connection with the mains ......................................................................................................................................... 5
Return Procedure .......................................................................................................................................................... 6
Claims .............................................................................................................................................................................. 6
Description of the device ................................................................................................................................................. 7
Features .......................................................................................................................................................................... 7
Overview ........................................................................................................................................................................ 7
Backside.......................................................................................................................................................................... 8
Installation ........................................................................................................................................................................... 8
Set Up and Operation ....................................................................................................................................................... 9
Control Modes ............................................................................................................................................................... 9
One Hydrogen (Built-in Programs) .......................................................................................................................... 9
Multiple Hydrogens (Master/Sl av e Mod e) ............................................................................................................ 9
Multiple Hydrogens (DMX Control) .......................................................................................................................10
Fixture Linking ...............................................................................................................................................................11
Data Cabling ...............................................................................................................................................................11
Control Panel ...............................................................................................................................................................12
Control Mode ..............................................................................................................................................................12
DMX Addressing ..........................................................................................................................................................12
Menu Overview ...........................................................................................................................................................13
Main M e nu O pt i ons ....................................................................................................................................................14
1.Settings Menu ........................................................................................................................................................14
2.Built-in Programs ....................................................................................................................................................14
3.DMX Mode .............................................................................................................................................................15
4.Master/Slave Mode ..............................................................................................................................................15
DMX Channels .............................................................................................................................................................15
4 channe ls .................................................................................................................................................................15
Maintenance ....................................................................................................................................................................16
Replacing the fuse...................................................................................................................................................16
Troubleshooting................................................................................................................................................................16
No Lig ht .........................................................................................................................................................................16
No Response to DMX..................................................................................................................................................16
Product Specifi ca tion .....................................................................................................................................................18
Dimensions ........................................................................................................................................................................19
Notes ..................................................................................................................................................................................20
1
Hydrogen DMX MKII
Your shipment includes:

Warning

Unpacking Instructions

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present, and have been received in good condition. Notify the dealer immediately and retain pac k i ng m at e rial for ins pe c t ion if any part s appear damaged from sh ipping or the c arton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Showtec Hydro gen DMX MKII including a hanging bracket
IEC power cable 1,5 m
User manual
LED Expected Lifespan
LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration of this decline. Packaged in cluster s, LEDs exhibi t higher operatin g temper a tures than in ideal or singular optimum conditions. For this reason when all color LEDs are used at their fullest intensity, life of the LEDs is significantly reduced. If improv i ng the device’s lifespan expectancy is of higher priority, place care in provid ing for lower opera t ional temperatures. Thi s may include cl imatic-environmental and the reduction of overall project i o n int ensity.

Safety Instructions

Every person involved with the installation, operation and maintenance of this device has to:
be qualified
follow the in s t ructions of this manual
2
Hydrogen DMX MKII
Before the initial start-up, plea s e make sure that ther e is no damage cau s e d by transpo rtation. Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to follo w t he safety instruct io ns and warning notes writ t e n in this manual.
Please consider that damages caused by manual modifications to the d evice are not subject to warranty.
This device contains no user-servic eable parts. Refer servi cing to qualified technicians only.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Never let the power cord co me into contact wi th other cables! Handle the power cor d and all connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Do not open the device and do not modify the device.
Never use anything to cover the ground contact.
Never leave the device running with ou t a lamp!
Never look directly into the light source.
Never leave any cables lying around.
Do not insert objects into air vents.
Do not connect this device to a dimmerpack .
Do not switch the device on and off in short intervals, as this would reduce the device’s life.
Do not shake the device. Avoid brute force when installing or operating the device. The Hydrogen
DMX MKII reacts very sensitively to movement.
Never use the device during thunderstorms, unplug the device immediately .
Only use device indoor, avoid contact with water or other liquids.
Do not touch the device’s housing bare-handed during its operation (housin g becomes hot).
Only oper ate t he device a fter having familiarized with its functions.
Avoid flames and do not put close to flammable liquids or gases.
Always keep case closed while operating.
Always allow free air space of at least 50 cm around the unit for ventilation.
Always disconnect power from the mains, when device is not used or before cleani ng ! Only handle
the power cord by th e pl ug. Never pull out the plug by tugging the power cord.
Make sure that the device is not exposed to extreme heat, moisture or dust.
Only install the device with the hanging bracket.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power-
cord from time to time.
If the external cable is damag e d, it has to be repl ac e d by a qualified technician.
If the lens or glass is obviously damaged, it has to be replaced. So that its functions are not impaired,
due to cracks or deep scratches.
If device is dropped or struck, disconnect mains power supply immediately. Have a qualified engineer inspect for safety before operatin g.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switc h it on immediat e l y. The arisi ng condensat i o n water might damage your device. Leave the device switched off until it has reached room temperature.
If your Sho w tec dev ice fails to work properly, discontinu e use immediatel y. Pack the u nit securely (pref e rably in th e or iginal pa cking material), and return it to you r Showtec dealer for service.
For adult use on l y. Light effect must be installed out of the reach of children. Never leave the unit running unattended.
For replacement, use fuses of same type and rating only.
The user is responsible for correct posi tioning and operating of the Hydrogen DMX MKII. The
manufac turer will not accept li ability for d amages caus e d by the mis us e or i ncorrect inst allation of this device.
3
Hydrogen DMX MKII
This device falls under protection cla ss I. Therefore it is essential to connect the yellow/green conductor to earth.
During th e initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defectiv e.
Repairs, servi cing and electric conn ection must be carried out by a qualified technician.
WAR RANTY: Till one year after date of purchase.

Operating Determinations

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
The minimum distance between light-output and the illuminated surface must be more than 1 meter.
The maximum ambient temperature ta = 45°C must never be exceeded.
The relative humidity must not exceed 50 % with an ambient temperature of 40° C.
If thi s dev ice is operated in any othe r way, than the one described in this manual, th e pro duct may
suffer damages and the warranty becomes void.
Any other operatio n may lead to d a ng e rs like shor t -circuit, burns, elec t ric shock, c rash etc.
You endanger your own safety and the safety of others!

Rigging

Please follow the European and national guidelines concerning rigging, trussing and all othe r safety issues.
Do not attempt the installation yourself ! Always let the installation be carried out by an authorized dealer !
Procedure:
If the projector is lowered from the ceiling or high joi sts, professional trussing systems have to be used.
Use a clamp to mount the projector, with the mounting-bracket, to the trussing system.
The projector must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net or
a safety cable.
When rigging, derigging or servicing the projector, always make sure, that the area below the installation place is block ed and stayin g in the area is forbidden.
Improper installation can cause serious injuries and damage of property !
4
Hydrogen DMX MKII
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
PHASE
N
BLUE
BLACK
SILVER
NEUTRAL
YELLOW/GREEN
GREEN
GREEN
PROTECTIVE GROUND
Hydrogen DMX MKII can be fitted to any kind of truss, with a safety cable and a clamp.

Connection with the mains

Connect the device to the mains with the power-plug. Always pay attention, that the right color cable is connected to the right place.
Make sure that the device is always connected properly to the earth!
Improper installation can cause serious damage to people and property!
5
Hydrogen DMX MKII
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be is sued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products retu rned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl Be prepared to provide the model number, serial number and a brief description of the cause for the retu rn. Be sure to properly pac k fixture, any shipping damage resulting from inad equate pa ckagin g is the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace produ c t ( s ). As a sugges t i on, prope r UPS packin g or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper inside the box:
01) Your na me
02) Your address
03) Your pho ne number
04) A brief description of the symptoms
and reque s t an RMA prior to shi pping the fixtur e .

Claims

The client has the obligation to check the delivered goods immedia tely upon delivery for any short­comings and/or visible defects, or perform this check after our announcement that the goods are at their disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibili ty to no tify and submit clai ms with the shipp er in the event that a fixture i s dama g ed due to shipping. Transportation damage has to be reported to us within one day after receipt of the d elivery. Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with a letter de f i ning the reason for retu rn shipment . Non-prepaid return shipments will be refused, unless otherwise agreed in writing. Complaints against us must be made known in writing or by fax within 10 working days after receipt of the invoice. After this period complaint s will no t be handled anymore. Complaints wil l only then be considered if the client has so far complied with all parts of the agreement, regardless of the agreement of which the obligation is resulting.
6
Hydrogen DMX MKII
Overview
Fig. 01
01) Adjustment scr ew
02) Lens

Description of the device

Features

The Showtec Hydrogen DMX MKII is a light effect with high output and great effects.
Input voltage: 100-240V 50/60 Hz
Continuous power: 30W
Control: Built-in programs, DMX-512, Master/Slav e
Light source: 1 x 20W LED
DMX control via standard DMX-controller
4 DMX channels
Fixture Connection: XLR Data in/out (XLR 3-pin)
4-digit LED dis pl a y
Housing: Black Metal & Flame-retardant plastic
Long LED lifetime
Strobe: 20Hz
Power connector: IEC In/Out
Beam angle: 25°
Plug & Play
Manual focus
Strong l ig ht output
Device slo wly switches between the colors : Red, Green, Blue, Purple, Yellow an d White in a realistic water wave effect
Fuse: T1AL/250V
Dimensions: 275 x 250 x 135 mm LxWxH (excl. bracket)
Weight: 3,5 Kg
7
Hydrogen DMX MKII
Backside
Fig. 02
03) DMX signal IN
04) DMX signal OUT
05) IEC Power OUT DC 100-240V
06) IEC Power IN DC 100-240V + Fuse T1AL/250V
07) Ground/earth connection
NOTE: Knowledge of DMX is required to fully utilize this unit.

Installation

Remove all packing materials from the Hyd rogen DMX MKII. Check if all foam and plastic paddin g is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing. Damages caused by non-observance are not subject to warranty.
8
Hydrogen DMX MKII
There are 3 modes:
Stand-alon e (built-in progra m s ) Master/Slave
DMX-512 (4CH)
The pins:
01) Earth
02) Signal (-)
03) Signal (+)
Multiple Hydro gens Ma s ter/ Sla ve Set Up
Fig. 03

Set Up and Operation

Follow the directions below, as they pertain to your preferred operat ion mod e. Before plug ging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to opera t e a 120V sp ecificatio n produc t on 240V power, or vice versa.

Control Modes

One Hydrogen (Built-in Programs)

01) Fasten the effect light onto firm trussin g. Leave at least 1 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Plug the end of the electric mains power cord into a proper electric power supply socket.
04) When the Hydrogen is not connect e d with a DMX cable, it functions as a stand-alone device.
05) Please see page 1 4-15 for more information about the built-in programs .

Multiple Hydro gens (Ma s ter/ Sla ve Mo de)

01) Fasten the effect light onto firm trussin g. Leave at least 0,5 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Plug the end of the electric mains power cord into a proper electric power supply socket.
04) Use a 3-pin XLR cable to connect the Hydrogens.
Link the u nit s as shown in fig. 3, connect a DMX signal cable from the first unit's DMX "out" socket to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units. You can use the same functions on the master device as described on pages 14-15. This means that you can set your desired operation mode on the master device and all slave devices will r eact th e same as the master device.
9
Hydrogen DMX MKII
Fig. 04

Multiple Hydrogens (DMX Control)

01) Fasten the effect light onto firm trussin g. Leave at least 1 meter on all sides for air circulation .
02) Always use a safety cable (ordercode 70140 / 70141).
03) Plug the end of the electric mains power cord into a proper electric power supply socket.
04) Use a 3-p XLR cable to connect the Hydrogens and other devices.
05) Link th e un its as shown i n (F ig. 04), Connect a DMX signal cable from the first unit's DMX "out" sock et to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
06) Suppl y e lectric power: Plug electric mains power cords into each unit's IEC socket, then plug the other end of the mains power cord into proper electric power supply sockets, starting with the first unit. Do not supply power before the whole system is set up and connec t ed prope rl y.
Multi ple Hy dr ogens DM X Set Up
10
Note: Link all cables before connecting electric power
Hydrogen DMX MKII
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the
isolated splitter may result in deterio ra tion of the digital DMX signal.

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
EIA-485 standard no more than 30 devices should be connected on one data link. Connecting more than 30 fixtures on one serial data link withou t the use of a DMX optically
Maximum recommended DMX data link distance: 100 meters Maximum recommend ed number of Hydrogens on a DMX data link: 30 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purcha se DAP Audio certifi ed DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own ca ble please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DAP Audio Certified DMX Data Cables
DAP Audio cable fo r allround u s e. bal. XLR/M 3 p. > XLR/F 3 p. Ordercode FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m. ), FL01 20 (20m. ).
DAP Audio cable fo r t he demandin g u se r with except ional audi o-qualities and connector made by Neutrik®. Ordercode FL71150 (1,5m.), FL713 (3m.), FL716 (6m. ), FL7110 (10m.).
The Hydrogen can be operated with a controller in control mode or without the controller in stand-alone
mode.
11
Hydrogen DMX MKII
A) LED display
B) Mode button
C) Setup button
D) Up button
E) Down button
Fig. 05
Display Off after 10 seconds

Control Panel

Control Mode

The fixtures are individually add ressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller. (When you selec t the DMX address and save it, the controller will display the sav ed DMX address the next time.)

DMX Addressing

The control panel on the front side of the base allows you to assign the DMX fixture address, which is the firs t ch annel from which the Hydrogen will respond to the controller. Please note when you use the controller, the unit has 4 channels. When using multiple Hydrogens, make sure you set the DMX addresses right. Therefore, the DMX address of the first Hydrogen should be 1(001); the DMX address of the second Hydrogen should be 1+4=5 (005); the DMX address of the third Hydrogen should be 5+4=9 (009), etc. Please, make sure that y ou do not hav e any overlapping channels in order to contr ol e ach Hydrogen correctly. If two or more Hydrogens are addressed similarly, they will work similarly.
Controlling:
After having addressed all Hydrogen fixtures, you may now start operating these via your lighting controller. Note: After switching on, the Hydrogen wil l automati cally detect wheth er DMX 512 data is received or not. If there is no data received at the DMX-input, the “ LED“ on the control panel will not flash. The problem may be:
The XLR cable from the controller is not connected with the input of the Hydrogen.
The controller is switched off or defective, the cable or connector is detective, or the signal wires
are swapped in the input connector.
Note: It’s necessary to insert a XLR termination plu g (with 120 Ohm) in the last fixtur e in order to ensure proper transmission on the DMX data link.
When no button is pressed for 10 seconds, the display will turn off. To ligh t up th e display, you hav e to pre s s t he MODE, SETUP, UP or DOW N butt on. Once you have pressed the button, the display will light up.
12
Hydrogen DMX MKII

Menu Overview

13
Hydrogen DMX MKII
Settings Menu
Built-in Programs
DMX address
Master/Slave Mode
Program’s run sp ee d, from off to full speed
Color change speed, from off t o a f ast-paced change
LED bri g htness, from off to very bright
Strobe settings, 0 = off, 1-99 = from slow to a fast-paced strobe flash

Main Menu Options

Upon ev e ry start-up , the device will reset th e software. will appear on the display for a short period of time. Subsequently, th e device will en ter last active mode, before it was switched off.

1.Settings Menu

Press the MODE butt o n until appears on the display.
01) Press the Up or Down button to toggle between the three following menus:
02)
While in this menu, press the SETUP bu tton . The display will shor tly fla sh . When it stops, the color wheel
has been reset. If the reset process is not completed successfully, will app ear on the display.
If t his communicate persists, even if the fixture was turned off and on, the fixture is damaged and
requires an inspection carried out by an authorize d technic i an.
03)
This menu is designed to reset the motor. Press the SETUP button and observe the display. If appears on the display, the reset process was not completed successfully. If appears on the display, the reset process was successful.
04)
While in this menu, press the SETUP button and the fixture will restore the factory settings. The motor
will reset, too.

2.Built-in Programs

With this menu you can you can set the built-in prog r am s .
01) Press the MODE button and then the Up / Down buttons, until the display shows .
02) Press the SETUP button to open thi s me nu.
03) You can use the SETUP button to s croll thro ugh the following settings and adjust them, if need be:
04) Press the MODE button and then the Up / Down buttons, until the display shows . In this menu, it is not possible to adjust the program’s run speed settings, as well as the color change settings. Neverth eless, th e LED brightn ess and strobe settin gs remain adju stabl e, just as in case of
.
14
Hydrogen DMX MKII
Channel 1 – LED brightness
0-255
From dark to brightest
Channel 2 – Wate r effect
0-127
Water effect active, from slow to fast
128-255
Water effect inactive
Channel 3 – Water effect color change
0-127
Water effect color change active , f rom slow to fa s t
128-255
Water effect color change inactive
Channel 4 – LED strobe
0-9
LED strobe inacti ve
10-255
LED strobe active, from slow to fast flash

3.DMX Mode

With this menu you can set the DMX address.
01) Press the MODE button and then the Up and Down buttons, until the display shows .
02) Press the SETUP button to open this me nu. You can choose 512 different DMX addresses.
03) Use the Up and Down buttons to select the required address from . Once you have set the desired DMX address, you can also choose the desired DMX Mode.
04) Press SETUP butto n again unt il you see . It indicates that the fixture is equipped with four active DMX channels.

4.Master/Slave Mode

With this menu you can set the Master or Slave.
01) Press the MODE button and then the Up and Down buttons, until the display shows . If the device has not been set to slave, it is automatically classified as a master device. All slave devices will copy the actions of the master device. If the device has been set to slave, it will react the same as its master device.

DMX Channels

4 channels

15
Hydrogen DMX MKII

Maintenance

The Showtec Hydrogen DMX MKII requires almost no maintena nce. However, you should keep the unit clean. Otherwise, the fixture’s li ght-output will be significantly reduced. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not im m erse in liqu i d. Wipe lens clean with glass cleaner and a soft cloth. Do not use alcohol or solvents. Keep connections cl ean. Disconnect electric power, and then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power.
The operator has to make sure that the safety related and machine-technical installations are to be inspected by an expert after every four years in the course of an acceptance test. The operator has to make sure that safety-relating and machine-technical installations are to be inspected by a skilled person once a year.
The following points have to be considered during the inspectio n :
01) All screws used for install ing the device or parts of the device have to be tightly connected and must not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechani cally movin g parts like a xles, ey es and others may not show any traces of wearing.
04) The electri c power supply cabl es must not show any damages or material fati gue.

Replacing the fuse

Power surges, short-circuit or inappropriate ele c tr ical power supply may cause a fus e to burn out. I f the fuse burns out, the produc t will not funct i on whatso ever. If this happen s , fo l l ow the directions below:
01) Unplug the unit from ele c t ric power source.
02) In ser t a screwdriver in to the slot in the fuse cover. Gently pry up the fuse cover. The fuse will come out.
03) Remove the used fuse. If brown or unclear, it is burned out.
04) Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to use a fuse of the same type and specification. See the product specification label for details.

Troubleshooting

No Light

This troubleshooting guid e is meant to help solve simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operat e s p r operly, do not carry out fol l owing ste ps. If the light effect does not operate properly, r e f e r servicing to a technici an. Response: Suspect three potential probl em ar eas: the po wer supply, the LEDs, the fuse.
01) Power supply. Check th at the unit is plugged in to an appropriate power supply.
02) The LEDs. Return the Hydro gen DMX MKII to yo ur S h owtec dealer.
03) The fuse. Repla ce the fuse. See above, for replacin g the fuse.
04) If all of the above appears to be O.K., plug the unit in again.
05) If you are unable to determine the cause of the problem, do not open the Hydrogen DMX MKII, as this may damage the unit and the warranty will become void.
06) Return th e device to your Showtec dealer .

No Response to DMX

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check th e D MX ca ble: Unplug the unit ; ch ange the DMX cable; then re connect to electric al power. Try your DMX control again.
03) Determine whether the controller or the light effect is at fault. Does the controller operate properly with ot her DMX produ cts ? If not, t ake the cont roller in f or repair . If so, take th e D MX c able and the light effect to a qualified technician.
16
Hydrogen DMX MKII
Problem
Probable cause(s)
Solution
No power to the fixture
Check if power is sw itc hed on and Primary fuse blown
Replace fuse
Fixtures reset
controller
The controller is not connected.
Conne c t controll er .
3-pin XLR Out of the controller
Install a phase reversing cable
Check data qualit y. If much low e r
distur bi ng t he li nk
Inspect connections and cables.
or replace damaged cables
Data link not terminated with 120 Ohm terminatio n pl ug
Insert terminatio n plug in outp ut
jack of the last fixture on the link
Incorrect addressing of the fixtures
Check address setting
Bypass one fixture at a time until
serviced by a qualified technician
Install a phase-reversing cable
erratically
Shutter closes
The color wheel, gobowheel or a the fixture is resetting the effect
Contact a technician for servicing
Fixtu re is too hot
Allow the fixture to cool down
Turn up the air conditioning
LEDs damaged
Disconnect the fixture and return it
to your dealer
The power supply settings do not frequency
Disconnect fixtur e. Check settin gs
One or more fixtures do not function at all
correctly, but all respond errat ically or not at a ll to the
does not match XLR Out of the first fixture on the link (i.e. signal is reversed)
cables are plugged in
between the controller and the first fixt ure on the li nk
Fixtures reset corre c t l y, but some respond errat ically or not at a ll to the controller
suddenly
Poor da t a quality
Bad data link connection
One of the f ixtures is defective a nd disturbs data transmissio n on the link
3-pin XLR Out on the fixtures does not match (pins 2 and 3 reversed)
gobo has lost its index position and
than 100 percent, the problem may be a bad data link conne c t i on, poor qual ity or broke n c ables, mis s i ng termin ation plug, or a d efectiv e fixture
Correct poor connections. Repair
normal operation is restored: unplug both connectors and connect them directly together.
Have the defective fixture
between the fixtures or swap pin 2 and 3 in the fixture that behaves
if the problem persists
No light or lamp cuts out intermittently
match local AC voltage and
17
Clean the fan
Make sure air vents in control panel and the front lens are not blocked
and correct if necessary
Hydrogen DMX MKII
Model:
Showtec Hydro gen DMX MKII
Input Vol t age:
100-240V 50/60 Hz
Continuous Power:
30 Watt
Fuse:
T1AL/250V
Dimensions:
275 x 250 x 135 mm LxWxH (excl. bracket)
Weight:
3,5 Kg
Operation an d Programming
Signal pin OUT :
pin 1 earth, pin 2 (-), pin 3 (+)
Set Up and Addressing:
LED cont rol panel
DMX Channels:
4 channe ls
Signal input:
3-pin XLR male
Signal output:
3-pin XLR female
Electro-mechanical effects
Colou r range:
Red, Gr e en , B l ue, Yellow, Purpl e , Wh ite
Mounting:
Mounti ng bracket
DMX-control:
Via standard DMX-controller
On Board:
Display for easy set up
Control:
DMX-512, Built-in Programs, Auto, Manual color, Master/Slave
Light So urc e :
1 x 20W LED
Beam Angle:
25°
Strobe:
0-20Hz
Housing:
Black M e tal & Flame-retardant plastic
Connections:
Dedicated IEC Power & Data connector
Cooling:
Conv e c tion (no fan s) which eliminates the use of fans and noise
Max. ambient temperature ta:
40°C
Max. housing temperature tB:
80°C
Minim um dista nce:
Minimum distance from flammable surfa ces:
0.5m
Minimum distance to lighted object:
1m

Product Specification

Design and product specifications are subject to change without prior notice.
Website: www.Showtec.info
Email: service@highlite.nl
18
Hydrogen DMX MKII

Dimensions

19
Hydrogen DMX MKII

Notes

20
Hydrogen DMX MKII
21
Hydrogen DMX MKII
22
©2014 Showtec
Loading...