Connection with the mains ......................................................................................................................................... 6
Description of the device ................................................................................................................................................. 8
Set Up and Operation .....................................................................................................................................................10
Charging the built in battery ....................................................................................................................................10
Control Modes .............................................................................................................................................................10
One EventBAR 100IR (Built-in programs, Auto Run) ...........................................................................................10
One EventBAR 100IR (Manual control) ................................................................................................................10
One EventBAR 100IR (Sound-control) ..................................................................................................................11
Data Cabling ...............................................................................................................................................................13
Control Panel ...............................................................................................................................................................14
DMX Control Mode .....................................................................................................................................................14
Main Menu Options ....................................................................................................................................................16
Auto Run Program ...................................................................................................................................................16
Sound control Mode ...............................................................................................................................................18
Static Color Mode ...................................................................................................................................................18
Power Mode .............................................................................................................................................................18
Optional remote control ...........................................................................................................................................19
Built-in Auto Show ....................................................................................................................................................20
Color mode ...............................................................................................................................................................20
Replacing a Fuse ........................................................................................................................................................25
No Light .........................................................................................................................................................................25
No Response to DMX ..................................................................................................................................................25
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure
that all parts are present, and have been received in good condition. Notify the dealer immediately and
retain packing material for inspection if any parts appear to be damaged from shipping or the carton
itself shows signs of mishandling. Save the carton and all packing materials. In the event that the fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box and
packing.
LED Expected Lifespan
LEDs gradually decline in brightness over time. HEAT is the dominant factor that leads to the acceleration
of this decline. Packaged in clusters, LEDs exhibit higher operating temperatures than in ideal or singular
optimum conditions. For this reason when all color LEDs are used at their fullest intensity, life of the LEDs is
significantly reduced. If improving the lifespan is of higher priority, place care in providing for lower
operational temperatures. This may include climatic-environmental and the reduction of overall
projection intensity.
Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
● be qualified
● follow the instructions of this manual
Before your initial start-up, please make sure that there is no damage caused by transportation. Should
there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to
follow the safety instructions and warning notes written in this manual.
Please consider that damages caused by manual modifications to the device are not subject to
warranty. This device contains no user-serviceable parts. Refer servicing to qualified technicians only.
3
Page 5
Ordercode: 44100
EventBAR 100IR
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of
this manual or any unauthorized modification to the device.
Never let the power cord come into contact with other cables! Handle the power cord and all
connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Never place any material over the lens.
Never look directly into the light source.
Never leave any cables lying around.
Do not insert objects into air vents.
Do not connect this device to a dimmerpack.
Do not switch the device on and off in short intervals, as this would reduce the device’s lifespan.
Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at
least 5 minutes before handling.
Do not shake the device. Avoid brute force when installing or operating the device.
Only use device indoor, avoid contact with water or other liquids.
Only operate the fixture after having checked that the housing is firmly closed and all screws are
tightly fastened.
Only operate the device after having familiarized with its functions.
Avoid flames and do not put close to flammable liquids or gases.
Always keep case closed while operating.
Always allow free air space of at least 50 cm around the unit for ventilation.
Always disconnect power from the mains, when device is not used or before cleaning! Only handle
the power cord by the plug. Never pull out the plug by tugging the power cord.
Make sure that the device is not exposed to extreme heat, moisture or dust.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power
cord from time to time.
If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired,
due to cracks or deep scratches.
If device was dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.
If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely
(preferably in the original packing material), and return it to your Showtec dealer for service.
For adult use only. Device must be installed out of reach of children. Never leave the unit running
unattended.
Never attempt to bypass the thermostatic switch or fuses.
For replacement, use fuses of same type and rating only.
The user is responsible for correct positioning and operating of the EventBAR 100IR. The manufacturer
will not accept liability for damages caused by the misuse or incorrect installation of this device.
This device falls under protection class I. Therefore it is essential to connect the yellow/green
conductor to earth.
Repairs, servicing and electrical connection must be carried out by a qualified technician.
WARRANTY: Till one year after date of purchase.
4
Page 6
Ordercode: 44100
EventBAR 100IR
Operating Determinations
●This device is not designed for permanent operation. Regular operation breaks will ensure that the
device will serve you for a long time without defects.
●The minimum distance between light-output and the illuminated surface must be bigger than 1
meter.
● The maximum ambient temperature ta = 40°C must never be exceeded.
● The relative humidity must not exceed 50 % with an ambient temperature of 40° C.
● If this device is operated in any other way than the one described in this manual, the product may
suffer damages and the warranty becomes void.
●Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.
You endanger your own safety and the safety of others!
Rigging
Please follow the European and national guidelines concerning rigging, trussing and all
other safety issues.
Do not attempt the installation yourself!
Always let the installation be carried out by an authorized dealer!
Procedure:
If the EventBAR 100IR is lowered from the ceiling or high joists, professional trussing systems have to
be used.
Use a clamp to mount the EventBAR 100IR, with the mounting-bracket, to the trussing system.
The EventBAR 100IR must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net
or safety-cable.
When rigging, derigging or servicing the EventBAR 100IR, always make sure, that the area below
the installation place is blocked and staying in the area is forbidden.
5
Page 7
Ordercode: 44100
EventBAR 100IR
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
PHASE
N
BLUE
BLACK
SILVER
NEUTRAL
YELLOW/GREEN
GREEN
GREEN
PROTECTIVE GROUND
The EventBAR 100IR can be placed on a flat stage floor or mounted to any kind of truss by a clamp.
Improper installation can cause serious injuries and/or damage of property!
Connection with the mains
Connect the device to the mains with the power plug.
Always check if the right color cable is connected to the right place.
Make sure that the device is always connected properly to the earth!
Improper installation can cause serious damage to people and property!
6
Page 8
Ordercode: 44100
EventBAR 100IR
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
Be prepared to provide the model number, serial number and a brief description of the cause of the
return. Be sure to properly pack fixture as any shipping damage resulting from inadequate packaging is
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper
inside the box:
01) Your name.
02) Your address.
03) Your phone number.
04) A brief description of the symptoms.
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any shortcomings and/or visible defects, or perform this check after our announcement that the goods are at their
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise.
It is the customer's responsibility to notify and submit claims with the shipper in the event that the fixture is
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt
of the delivery.
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless
agreed otherwise in writing.
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the
invoice. After this period, complaints will not be handled anymore.
Complaints will only be considered if the client has so far complied with all parts of the agreement,
regardless of the agreement of which the obligation is resulting.
7
Page 9
Ordercode: 44100
EventBAR 100IR
Description of the device
Features
The EventBAR 100IR is a LED bar from Showtec. It is a very versatile and inexpensive batten effect for all
sorts of locations and applications.
• LEDs: 240 RGB high intensity 10mm LEDs (Red 96, Green 72, Blue 72)
• Beam angle: 30 º
• Compact and lightweight
• Long battery life
• Built-in battery charger and protection
• 8 sections
• Output: Red: 110 Lux@2m
Green: 234 Lux@2m
Blue: 250 Lux@2m
Full On: 490 Lux@2m
• Colormixing: RGB
• Colour range: 16,7 million additive colors
• Power Supply: 100-240V AC, 50/60Hz
• Control Mode: DMX512
• Dimmer: 0-100%
• Strobe: 0-20Hz
• Consumption Power: 42 Watt
• 3 pin female XLR socket and 3 pin male XLR socket
• IEC Power In
• Linkable via 3-pin XLR cable
• Built-in microphone
• Power coated aluminum and steel
• LED display
• Fuse: T1AL / 250V
• Cooling: convection
• IP rating: IP-20
• Built-in programs mode, Auto running mode, DMX mode, slave mode, static color mode and sound-
• Dimensions: 1070 x 70 x 135 mm (LXWXH) (incl. brackets)
• Weight: 3,38 kg
Note: Knowledge of DMX is required to fully utilize this unit.
Optional accessories
44002 UR-5 Universal IR Remote
8
Page 10
Ordercode: 44100
EventBAR 100IR
Fig. 01
Fig. 02
Overview
01) Adjustment screw + mounting bracket for Truss mounting
02) 240 RGB high intensity 10mm LEDs
Backside
03) IEC Power In + fuse T1AL / 250V
04) Ground/Earth connection
05) Ground/Earth connection
06) Power Switch On/Off
07) Menu Buttons + LED display
08) Safety eye
09) Power LED indicator
10) DMX signal connector (IN) 3-pin
11) DMX signal connector (OUT) 3-pin
9
Page 11
Ordercode: 44100
EventBAR 100IR
There are 6 modes:
Auto Run
Built-in Programs
Manual control (Static)
Sound-controlled
Master/Slave
DMX512
Installation
Remove all packing materials from the EventBAR 100IR.
Check that all foam and plastic padding is removed. Connect all cables.
Do not supply power before the whole system is set up and connected properly.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.
Connect the device to the main power supply.
Charging the built in battery
01) In order to charge the battery you’ll have to use the included power cable.
02) Turn off the power.
03) Connect thepower cable into an appropriate power supply.
04) The power indicator LEDs will light up in sequence.
05) It will take 10 hours to be fully charged. All LEDs from the LED indicator will light up when the device is
completely charged.
06) When the EventBAR is fully charged, you can use the EventBAR for approx. 6,0 hours at full RGB.
07) The Power LED indicator on the back shows the energy level of the battery (100-80%, 60%, 40%, 20%,
20%-0).
Important!
• Charge the battery when the red LED (energy level < 20%) of the LED indicator flashes.
• You have to charge the battery every 3 months at least one time.
• Do not use the fixture in a high temperature environment, because the lithium battery could be
damaged or It will reduce the lifetime of the battery.
Control Modes
One EventBAR 100IR (Auto Run, Built-in programs)
01) Fasten the effect light onto firm trussing or place it on the floor. Leave at least 0,5 meter on all sides
for air circulation.
02) When the EventBAR is not connected by a DMX-cable, it functions as a stand-alone device.
03) If device is set to or , then the fixture will play one of its built-in programs or show its
auto run mode. Please see pages 16-17 for more information about the built-in programs or auto run
mode.
One EventBAR 100IR (Manual control)
01) Fasten the effect light onto firm trussing or place it on the floor. Leave at least 0,5 meter on all sides
for air circulation.
02) When the EventBAR is not connected by a DMX-cable, it functions as a stand-alone device.
03) If device is set to , then the fixture can be manually controlled.
04) Please see page 18 for more information about the Manual control mode.
10
Page 12
Ordercode: 44100
EventBAR 100IR
The pins:
1. Earth
2. Signal (-)
3. Signal (+)
Fig. 03
One EventBAR 100IR (Sound-control)
01) Fasten the effect light onto firm trussing or place it on the floor. Leave at least 0,5 meter on all sides
for air circulation.
02) When the EventBAR is not connected by a DMX-cable, it functions as a stand-alone device.
03) Turn on the music. If device is set to (Audio), then the fixture will react to the beat of the
music. Please see page 18 for more information about the Sound-controlled mode.
Multiple EventBARs 100IR (Master/Slave control)
01) Fasten the effect light onto firm trussing or place it on the floor. Leave at least 0,5 meter on all sides
for air circulation.
02) Plug the end of the electric mains power cord into a proper electric power supply socket.
03) Use a 3-p XLR cable to connect the EventBAR and other devices.
04) Link the units as shown in Fig. 03, connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second and third units. You can use the
same functions on the master device as described on pages 16-17 (Auto run, Built-in Programs). This
means you can set your desired operation mode on the master device and all slave devices will
react the same as the master device.
Multiple EventBARs 100IR (Master/Slave control)
11
Page 13
Ordercode: 44100
EventBAR 100IR
Fig. 04
Multiple EventBARs 100IR (DMX512 Mode)
01) Fasten the effect light onto firm trussing or place it on the floor. Leave at least 0,5 meter on all sides
for air circulation.
02) Plug the end of the electric mains power cord into a proper electric power supply socket.
03) Use a 3-p XLR cable to connect the EventBAR and other devices.
04) Link the units as shown in Fig. 04, Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second and third units.
05) Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the
other end of the mains power cord into proper electric power supply sockets, starting with the first
unit. Do not supply power before the whole system is set up and connected properly.
Multiple EventBARs 100IR DMX Set Up
12
Note: Link all cables before connecting electric power!
Page 14
Ordercode: 44100
EventBAR 100IR
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically
isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of EventBARs 100IR on a DMX data link: 30 fixtures
Maximum recommended number of EventBARs 100IR on a Power link: 11 fixtures @110V
Maximum recommended number of EventBARs 100IR on a Power link: 21 fixtures @240V
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixt ures the
data link can support.
The EventBAR 100IR uses up to 24 channels.
Data Cabling
To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
A. LED Display
B. Mode button
C. Setup Button
D. Up Button
E. Down Button
Fig. 05
Display Off after 10 seconds
Control Panel
DMX Control Mode
The fixtures are individually addressed on a data-link and connected to the controller.
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it,
the controller will display the saved DMX address the next time.)
DMX Addressing
The control panel on the backside of the device allows you to assign the DMX fixture address, which is
the first channel from which the EventBAR will respond to the controller. Please note when you use the
controller, the unit has up to 24 channels. When using multiple EventBARs, make sure you set the DMX
addresses right. Therefore, the DMX address of the first EventBAR should be 1(d001); the DMX address of
the second EventBAR should be 1+24=25 (d025); the DMX address of the third EventBAR should be
25+24=49 (d049), etc. Please, be sure that you do not have any overlapping channels in order to control
each EventBAR correctly. If two or more EventBARs are addressed similarly, they will work similarly.
Controlling:
After having addressed all EventBARs, you may now start operating these via your lighting controller.
Note: After switching on, the EventBAR will automatically detect whether DMX 512 data is received or not. The problem may be:
• The XLR cable from the controller is not connected with the input of the EventBAR.
• The controller is switched off or defective, the cable or connector is defective, or the signal wires are
swapped in the input connector.
Note: It is necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.
When no button is pressed for 10 seconds, the display will turn off. To light up the display, you have to
press the Mode, Setup, Up or Down button. Once you have pressed the button, the display will light up.
14
Page 16
Ordercode: 44100
EventBAR 100IR
Menu overview
15
Page 17
Ordercode: 44100
EventBAR 100IR
Auto Run
Built-in Programs
Slave
DMX mode
Sound controlled
Color
Power mode
Main Menu Options
Auto Run Program
With this menu you can set the Auto run mode of the EventBAR 100IR.
01) Press the Mode button on the device, until the display shows .
02) The EventBAR will start automatically with its auto program.
Built-in Programs
With this menu you can choose a built-in program.
01) Press the Mode button on the device, until the display shows .
02) You can choose 20 built-in programs , by using the Up and Down buttons.
03) If you choose and you press Setup you can choose between 9 programs and Off with the
Up and Down buttons.
04) Press Setup again and you can set the strobe value by using the Up and Down buttons.
05) Press the Mode button to go back to .
06) With the Up and Down buttons you can choose between .
16
Page 18
Ordercode: 44100
EventBAR 100IR
2 Channels
7 Channels
3 Channels
5 Channels
24 Channels
07) Press the Setup button to set the speed or strobe value.
08) Use the Up and Down buttons to set the speed and strobe value between 0-99 or SPFL.
Master / slave addressing
Master
01) The default setting for this device is master.
02) Only one fixture can be the master.
Note:
• Disconnect the fixture from the DMX controller before master/slave operating, otherwise data
collisions may occur and the fixtures will not work properly!
• In master/slave mode, the master fixture can execute the built-in programs, all the slave fixtures will
work the same.
• When operating the master/slave chain, you can identify the master fixture from the slave fixtures
easily. The master doesn’t have any cable plugged into the DMX input connector.
Slave control
This function allows you to control the slaves from the master’s control panel in a master/slave setup.
01) Only 1 fixture can be the master, the others have to be Slaves. The Default setting for a device is
Master. So on the first device you don’t have to change anything.
On the slave devices you must press the Mode button until the display shows .
02) All slave devices must have address .
DMX Mode
With this menu you can set the DMX address and choose a DMX configuration.
01) Press the Mode button, until the display shows .
02) You can choose 512 different DMX addresses.
03) Use the Up and Down buttons to select the required address between .
04) You can also press the Setup button to choose a different DMX Mode . The
display will blink.
17
Page 19
Ordercode: 44100
EventBAR 100IR
Press Setup and you can set the sensitivity from low-sensitivity to
high-sensitivity between SU.00 - SU.31 with the Up and Down
buttons.
Sound control Mode
With this menu you can set the sensitivity of the sound mode from the EventBAR 100 IR.
01) Press the Mode button on the device, until the display shows . Turn on the music and the
EventBAR 100IR will react to the beat of the music.
Static Color Mode
With this menu you can create a static color.
01) Press the Mode button, until the display shows .
02) Press the Setup button to create a specific color.
03) With this submenu you can set 3 static colors of the EventBAR.
You can choose Red, Green or Blue by pressing the Setup button.
Use the Up / Down buttons to set the values of each individual color from 000-255.
You can combine RED, GREEN and BLUE to create an infinite range of colors (0-255).
Power Mode
With this menu you can see the energy level of the lithium battery inside of the EventBAR.
01) Press the Mode button, until the display shows .
02) Press the Setup button to see the energy level in %, from 0 - 100%.
18
Page 20
Ordercode: 44100
EventBAR 100IR
Button
Function
Description
On / Off
Switch the device ON or OFF
Auto Mode
Activate Built-in Auto Show mode
Program Mode
Activate Built-in Programs Show mode
Sound-controlled Mode
Activate Sound-controlled mode
Speed Mode
Activate Speed mode
Strobe Mode
Activate Strobe mode
Dimming Mode
Activate Dimming Mode
Plus
Increase button
Minus
Decrease button
Red
Activate the Red color
Green
Activate the Green color
Blue
Activate the Blue color
Amber
Activate the Amber color
White
Activate the White color
Cyan
Activate the Cyan color
Purple
Activate the Purple color
Optional remote control
19
Page 21
Ordercode: 44100
EventBAR 100IR
Button
Function
Description
Purplish red
Activate the Purplish red color
Orange
Activate the Orange color
White
Activate the White color
Bright pink
Activate the Bright pink color
Light green
Activate the Light green color
Water blue
Activate the Water blue color
Yellow
Activate the Yellow color
Warm white
Activate the Warm white color
Built-in Auto Show
01) Press the button to activate Built-in Auto Show mode.
02) The EventBAR will start automatically with its built-in program.
Built-in programs
01) Press the button to activate Built-in programs mode.
02) With the and buttons you can choose between .
03) In this mode you can control the speed of the program by pressing the button.
04) You can choose between by using the and buttons.
05) You can also set the strobe of the program by pressing the button.
06) With the and buttons you can set the strobe between .
Note: You can set only the strobe value if you choose Pr.01.
Sound-controlled mode
01) Press the button to activate the Sound-controlled mode.
02) With the and buttons you can set the sensitivity between .
Dimming mode
01) Press the button to activate the dimming mode.
02) Now you can choose one of the RGB colors by pressing the , or button.
03) With the and buttons you can set the intensity of the colors individual between
, or .
04) With this mode you can create your desired color.
Color mode
01) You can select pre-programmed colors with the buttons -.
02) Please look at pages 19 and 20 which colors are pre-programmed.
20
Page 22
Ordercode: 44100
EventBAR 100IR
Channel 1 – Built-in Programs
0-11
Program 01
12-23
Program 02
24-35
Program 03
36-47
Program 04
48-59
Program 05
60-71
Program 06
72-83
Program 07
84-95
Program 08
96-107
Program 09
108-119
Program 10
120-131
Program 11
132-143
Program 12
144-155
Program 13
156-167
Program 14
168-179
Program 15
180-191
Program 16
192-203
Program 17
204-215
Program 18
216-227
Program 19
228-239
Program 20
240-255
Sound mode
Channel 2- Preset Colors (CH1 must be set between 001-011 )
0-27
Black
28-55
Red
56-83
Yellow
84-111
Light green
112-139
Green
140-167
Light blue
168-195
Blue
196-223
Purple
224-251
Pink
252-255
White
Channel 2- Speed (CH1 must be set between 012-239 )
0-255
Gradual adjustment Speed, From slow to fast
Channel 1 – Red Dimmer intensity (CH5 must be set between 001-255 )
0-255
Gradual adjustment Red from 0 – 100%
Channel 2 – Green Dimmer intensity (CH5 must be set between 001-255 )
0-255
Gradual adjustment Green from 0 – 100%
Channel 3 – Blue Dimmer intensity (CH5 must be set between 001-255 )
0-255
Gradual adjustment Blue from 0 – 100%
DMX Channels
2 DMX Channels
7 DMX Channels
21
Page 23
Ordercode: 44100
EventBAR 100IR
Channel 4 – Shutter / Strobe (CH1, CH2, CH3 or CH5 must be set between 001-255 )
0-255
Strobe (0-20Hz, color strobe selected by CH1-CH3)
Channel 5 – Dimmer
0-255
Gradual adjustment, from dark to brightest 0-100%
Channel 6 – Built-in Programs (CH5 must be set between 001-255 )
0-11
Program 01
12-23
Program 02
24-35
Program 03
36-47
Program 04
48-59
Program 05
60-71
Program 06
72-83
Program 07
84-95
Program 08
96-107
Program 09
108-119
Program 10
120-131
Program 11
132-143
Program 12
144-155
Program 13
156-167
Program 14
168-179
Program 15
180-191
Program 16
192-203
Program 17
204-215
Program 18
216-227
Program 19
228-239
Program 20
240-255
Sound mode
Channel 7- Preset Colors (CH6 must be set between 001-011 )
0-27
Black
28-55
Red
56-83
Yellow
84-111
Light green
112-139
Green
140-167
Light blue
168-195
Blue
196-223
Purple
224-251
Pink
252-255
White
Channel 7- Speed (CH6 must be set between 012-239 )
0-255
Gradual adjustment Speed, From slow to fast
Channel 1 – Red Dimmer intensity
0-255
Gradual adjustment Red from 0 – 100%
Channel 2 – Green Dimmer intensity
0-255
Gradual adjustment Green from 0 – 100%
Channel 3 – Blue Dimmer intensity
0-255
Gradual adjustment Blue from 0 – 100%
3 DMX Channels
22
Page 24
Ordercode: 44100
EventBAR 100IR
Channel 1 – Red Dimmer intensity (CH4 must be set between 001-255 )
0-255
Gradual adjustment Red from 0 – 100%
Channel 2 – Green Dimmer intensity (CH4 must be set between 001-255 )
0-255
Gradual adjustment Green from 0 – 100%
Channel 3 – Blue Dimmer intensity (CH4 must be set between 001-255 )
0-255
Gradual adjustment Blue from 0 – 100%
Channel 4 – Dimmer
0-255
Gradual adjustment, from dark to brightest 0-100%
Channel 5 – Shutter / Strobe (CH1, CH2, CH3 or CH4 must be set between 001-255 )
0-255
Strobe (0-20Hz, color strobe selected by CH1-CH3)
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
5 DMX Channels
24 DMX Channels
Channel 1 – Red Section 1
Channel 2 – Green Section 1
Channel 3 – Blue Section 1
Channel 4 – Red Section 2
Channel 5 – Green Section 2
Channel 6 – Blue Section 2
Channel 7 – Red Section 3
Channel 8 – Green Section 3
Channel 9 – Blue Section 3
Channel 10 – Red Section 4
23
Page 25
Ordercode: 44100
EventBAR 100IR
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
0-255
Gradual adjustment Red from 0 – 100%
0-255
Gradual adjustment Green from 0 – 100%
0-255
Gradual adjustment Blue from 0 – 100%
Channel 11 – Green Section 4
Channel 12 – Blue Section 4
Channel 13 – Red Section 5
Channel 14 – Green Section 5
Channel 15 – Blue Section 5
Channel 16 – Red Section 6
Channel 17 – Green Section 6
Channel 18 – Blue Section 6
Channel 19 – Red Section 7
Channel 20 – Green Section 7
Channel 21 – Blue Section 7
Channel 22 – Red Section 8
Channel 23 – Green Section 8
Channel 24 – Blue Section 8
24
Page 26
Ordercode: 44100
EventBAR 100IR
Maintenance
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01) All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04) The electric power supply cables must not show any damages or material fatigue.
The Showtec EventBAR 100IR requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s light-output will be significantly reduced. Disconnect the mains power supply and
then wipe the cover with a damp cloth. Wipe the front glass panel clean with glass cleaner and a soft
cloth. Do not use alcohol or solvents. The front glass panel will require weekly cleaning, as smoke-fluid
tends to build up residues, reducing the light-output very quickly. Do not immerse in liquid.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying
electric power.
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below:
01) Unplug the unit from electric power source.
02) Insert a flat-head screwdriver into a slot in the fuse cover. Gently pry up the fuse cover.
the fuse will come out.
03) Remove the used fuse. If brown or unclear, it is burned out.
04) Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, follow the steps below in sequence until a solution is found. Once the unit operates
properly, do not carry out the following steps.
If the light effect does not operate properly, refer servicing to a technician.
Response: Suspect four potential problem areas as the power supply, the LEDs, the fuse and the battery.
01) Power supply. Check that the unit is plugged into an appropriate power supply.
02) The LEDs. Return the EventBAR 100IR to your Showtec dealer.
03) The fuse. Replace the fuse. See page 25 for replacing the fuse.
04) Battery. Check if the battery is fully charged.
05) If all of the above appears to be in order, switch the unit on again.
06) If you are unable to determine the cause of the problem, do not open the EventBAR 100IR, as this
may damage the unit and the warranty will become void.
07) Return the device to your Showtec dealer.
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card
malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03) Determine whether the controller or light effect is to blame. Does the controller operate properly with
other DMX products? If not, take the controller in for repair. If it does, take the DMX cable and the
light effect to a qualified technician.
25
Page 27
Ordercode: 44100
EventBAR 100IR
Problem
Probable cause(s)
Solution
One or more
fixtures do not
function at all
No power to the fixture
•Check if power is switched on and
cables are plugged in. Check the
battery is fully charged.
Primary fuse blown
•Replace fuse
Fixtures reset
correctly, but all
respond
erratically or not
at all to the
controller
The controller is not connected.
•Connect controller.
3-pin XLR Out of the controller
does not match XLR Out of the first
fixture on the link (i.e. signal is
reversed)
•Install a phase reversing cable
between the controller and the
first fixture on the link
Fixtures reset
correctly, but
some respond
erratically or not
at all to the
controller
Poor data quality
•Check data quality. If much lower
than 100 percent, the problem
may be a bad data link
connection, poor quality or
broken cables, missing termination
plug, or a defective fixture
disturbing the link
Bad data link connection
•Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables
Data link not terminated with 120
Ohm termination plug
•Insert termination plug in output
jack of the last fixture on the link
Incorrect addressing of the fixtures
•Check address setting
One of the fixtures is defective and
disturbs data transmission on the
link
•Bypass one fixture at a time until
normal operation is restored:
unplug both connectors and
connect them directly together.
•Have the defective fixture
serviced by a qualified technician
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed)
•Install a phase-reversing cable
between the fixtures or swap pin 2
and 3 in the fixture that behaves
erratically
No light or LEDs
cuts out
intermittently
Fixture is too hot
• Allow the fixture to cool down
• Clean the fan
• Turn up the air conditioning
LEDs damaged
•Disconnect the fixture and return it
to your dealer
The power supply settings do not
match local AC voltage and
frequency
•Disconnect fixture. Check settings
and correct if necessary
26
Page 28
Ordercode: 44100
EventBAR 100IR
Model:
Showtec EventBAR 100IR
Input Voltage:
100-240V AC, 50/60Hz
Consumption Power
42 Watt
DMX linking:
30pcs
Fuse:
T1AL / 250V
Dimensions:
1070 x 70 x 135 mm (LxWxH) (incl. brackets)
Weight:
3,38 kg
Operating and Programming:
Signal pin OUT:
Pin 1 (earth), pin 2 (-), pin 3 (+)
DMX Mode:
2, 3, 5, 7 and 24 DMX channel operation
Signal input:
3-pin XLR male
Signal output:
3-pin XLR female
Electro-mechanical effects:
Light source:
240 RGB high intensity 10mm LEDs
(Red 96, Green 72, Blue 72)
Output:
Red: 110 Lux@2m
Green: 234 Lux@2m
Blue: 250 Lux@2m
Full On: 433 Lux@2m
Beam Angle:
30 º
Sections:
8
Dimmer:
0-100%
Strobe:
0-20Hz
Color Range:
RGB (16,7 million additive colors)
Cooling:
convection
Display:
LED display
Housing:
Power coated aluminum and steel
IP rating:
IP-20
DMX-control:
DMX512 via standard DMX-controller
Control:
DMX, Auto, Sound, Static, Slave
Connections:
XLR Data in/out (XLR 3-pin), IEC Power In
Built-in battery charger and protection
Built-in microphone
Max. ambient temperature ta:
40°C
Max. housing temperature tB:
80°C
Minimum distance:
Minimum distance from flammable surfaces:
0,5 m
Minimum distance to lighted object:
1 m
Website: www.Showtec.info
Email: service@highlite.nl
Product Specifications
Design and product specifications are subject to change without prior notice