SHARP UP-820N, UP-820F User Manual [fr]

TERMINAL DE POINT DE VENTE SYSTEME DE COMMUNICATION DIRECTE ENTRE ENREGISTREUSES
MODELE
UP-820F UP-820
MANUEL D´INSTRUCTIONS
N
TABLE DES MATIERES
Introduction ·············································································································································3
Opération de traitement immédiat ·········································································································4
1. Affichage de messages ·························································································································4 (1) Message affiché pendant une communication de traitement immédiat ············································4 (2) Messages d’erreurs···························································································································5
2. Opération d’ouverture du magasin (mode OPXZ) – machines principale et satellites ···························6
3. Opération de fermeture du magasin (mode OPXZ) – machines principale et satellites·························7
4. Système des employés ··························································································································8 (1) Système d’un fichier centralisé des employés ··················································································8 (2) Système d’un fichier individuel des employés···················································································9
5. Opération d’entrée en communication (affectation d’un employé) (mode REG/mode MGR)···············10
6. Rapport d’entrée en communication d’un employé ··············································································11
7. Sortie du système d’entrée en communication (annulation de l’affectation d’un employé) (mode REG/mode MGR) ·································································································································12
8. Téléchargement des contenus de la programmation aux machines satellites – machine principale ···13 (1) Téléchargement initial ·····················································································································13 (2) Téléchargement de mise à jour·······································································································14
9. Recherche et mise à jour d’un fichier GLU···························································································17 (1) Système d’un fichier GLU centralisé ·······························································································17 (2) Système d’un fichier GLU individuel ·······························································································17
10. Contrôle d’un stock de PLU/EAN ·········································································································18
11. Appel des consignations d’opérations (T-LOG)····················································································19
12. Contrôle des données PLU/EAN ··········································································································20
13. Fonction de changement d’un prix ·······································································································22
14. Contrôle des données d’un client ·········································································································22
15. Communication avec une imprimante à distance (en option)······························································23
16. Réacheminement des données d’impression·······················································································24
Rapports regroupés et individuels ······································································································25
1. Modes d’exploitation·····························································································································25
2. Rapports regroupés – machine principale et machine principale de sauvegarde ································26 (1) Procédure pour l’établissement d’un rapport ··················································································26 (2) Liste de rapports regroupés (SYSTEME DE LECTURE ET DE REMISE A ZERO) ·······················27
3. Rapports individuels – machine principale, machine principale de sauvegarde et machines satellites················································································································································29 (1) Procédure pour l’établissement d’un rapport ··················································································29 (2) Liste de rapports individuels (LECTURE ET REMISE A ZERO)·····················································30
4. Rapports de remise à zéro dans un système sans fichier de sauvegarde ···········································32
5. Rapport d’un employé ··························································································································33 (1) Système d’un fichier centralisé des employés ················································································33 (2) Système d’un fichier individuel des employés·················································································34
6. Rapport d’un caissier····························································································································35
7. Rapports qui peuvent être établis lorsque la fonction de déclaration obligatoire de liquidités/ chèques (CCD) est autorisée ···············································································································36
8. Opération d’effacement d’une remise à zéro (modes X1/Z1 et X2/Z2) – machine principale ··············37
Programmation du système IRC (communication directe entre enregistreuses)···························38
1. Réglage des numéros de machines – machines principale et satellites ··············································38
2. Réglage des numéros terminaux (numéros de machines IRC) pour les machines satellites ··············39
3. Réglage initial pour la machine principale et création/ mise à jour de la liste principale ······················40 (1) Réglage du numéro terminal pour la machine principale et création de la liste principale ·············40 (2) Suppression d’une machine de la liste principale ···········································································41
4. Désignation du terminal pour servir en tant que machine principale de sauvegarde – machine principale ··············································································································································42
3
2
1
1
2
5. Désignation pour autoriser ou interdire la fonction de réessai du système lorsqu’une erreur de transmission se produit – machines principale et satellites··································································43
6. Choix pour rechercher d’abord la machine principale ou une satellite pour un code PLU/EAN – machine satellite···································································································································44
7. Lecture des contenus de la programmation IRC – machines principale et satellites ···························45
8. Programmation pour l’imprimante à distance ·······················································································47 (1) Programmation de base pour l’imprimante à distance – machines principale et satellites ·············47 (2) Programmation optionnelle pour l’imprimante à distance – machines principale et satellites ········49
9. Programmation pour le poste de travail du directeur (MWS) – machines principale et satellites·········51 (1) Programmation d’un numéro terminal·····························································································51 (2) Programmation de la durée d’attente······························································································52 (3) Programmation du numéro de la passerelle ···················································································52
10. Lecture des contenus de la programmation du poste de travail du directeur (MWS) – machines principale et satellites ···························································································································53
Système de sauvegarde ·······················································································································54
1. Comment fonctionne le système de sauvegarde IRC ··········································································54
2. Déclaration de la machine principale····································································································55 (1) Lorsque la machine principale tombe en panne – Déclaration de la machine principale à la
machine principale de sauvegarde ·································································································55
(2) Lorsque la machine principale de sauvegarde tombe en panne – Déclaration de la machine
principale de sauvegarde à la machine principale ··········································································57
3. Déclaration de reprise ··························································································································58 (1) Lorsque la machine principale retrouve sa condition normale – Déclaration de reprise à la
machine principale de sauvegarde ·································································································58
(2) Lorsque la machine principale de sauvegarde retrouve sa condition normale – Déclaration
de reprise à la machine principale ··································································································60
Reprise en cas d’une erreur ·················································································································61
1. Opération de suppression manuelle·····································································································61 (1) Procédure de suppression manuelle ······························································································61 (2) Liste des articles d’une suppression manuelle ···············································································62
2. Fonction de réessai du système···········································································································63 (1) Lorsque la fonction de réessai du système est interdite ·································································63 (2) Lorsque la fonction de réessai du système est autorisée ·······························································64
DONNEES TECHNIQUES DE BASE POUR LAN ·················································································65
6
5
4
3
Introduction
Le système de communication directe entre enregistreuses (IRC) UP-820F/UP-820N se compose d’une machine principale et de jusqu’à 31 machines satellites qui sont toutes interconnectées par le réseau local (LAN) pour permettre une transmission de données entre elles. Ce système permet au directeur d’exercer un contrôle centralisé sur l’ensemble des machines satellites par l’intermédiaire de la machine principale.
• Une des machines satellites peut être utilisée en tant que machine principale de sauvegarde.
Une carte RAM supplémentaire, UP-S04MB2, doit être installée dans la machine principale et, si possible, dans chaque machine satellite.
NOTA
LAN
Machine principale Machine satellite
31 machines satellites max.
Machine satellite
4
1
Opération de traitement immédiat
(1) Message affiché pendant une communication de traitement
immédiat
1) Le message montré ci-dessous est affiché sur l’écran de la machine principale qui est engagée dans une transmission IRC.
Ex.:
Le message ci-dessus est aussi affiché sur l’écran de la machine satellite qui est engagée dans une transmission de remise à zéro du système.
2) Le numéro de machine de la machine satellite communiquant avec la machine principale est affiché sur l’écran de la machine principale après le démarrage dune transmission IRC.
Ex.:
Dans ce cas, le numéro de machine de la machine satellite est 000022”.
000022
NOTA
SENDING DATA
1. Affichage de messages
5
(2) Messages derreurs
Lorsquune erreur se produit, un message derreur correspondant est affiché. Pour effacer un message derreur, appuyez sur la touche
L
.
Pour les messages derreurs, voyez le tableau ci-dessous.
Liste des messages derreurs
Messages derreurs
(implicites)
Description
• Ce message vous demande de réessayer de communiquer avec la machine
avec laquelle la communication n’a pas réussie.
• La machine destinataire est occupée.
• L’employé spécifié est entré en communication avec une autre machine.
• Le code GLU introduit est en train d’être utilisé.
• La mémoire du code GLU ou du fichier apparenté est insuffisante.
• Erreur de transmission
• L’imprimante à distance ne fonctionne pas correctement.
• L’employé qui a introduit un code GLU n’a pas été autorisé.
• Téléchargement initial de IRC avant une remise à zéro.
• La machine principale de sauvegarde ne répond pas à la demande.
• La machine principale de répond pas à la demande.
• Erreur de mise hors ligne de l’imprimante à distance.
• La machine destinataire est mise hors circuit.
• La mémoire intermédiaire de consignation des opérations (T-LOG) est pleine.
• Le fichier dans la machine principale et celui dans la machine satellite ne sont
pas du même type.
• Le code de l’employé spécifié ne se trouve pas dans la liste principale.
• Le code GLU introduit n’est pas répertorié.
• L’entrée efffectuée n’est pas valable.
RETRY
BUSY
CODE NOT FREE
LACKING MEMORY
LINE ERROR
MOTOR LOCK
NO AUTHORITY
NON RESET
BACKUP DOWN?
MASTER DOWN?
OFF LINE
POWER OFF
T-LOG FULL
TYPE ERROR
UNDEFINED CODE
ENTRY ERROR
6
Lorsque lopération douverture du magasin est effectuée à la machine principale, le système IRC est ouvert. Le Terminal de Point de Vente peut envoyer une instruction AT par ce travail. Cette fonction contrôle un modem, mais na pas de fonction de contrôle sur un enregistrement et T-LOG (consignation des opérations). La procédure pour lopération douverture du magasin est expliquée ci-après.
Sélectionnez OPEN STORE à partir de la fenêtre du mode OPXZ et appuyez sur la touche
e
.
• Vous pouvez aussi effectuer l’opération d’ouverture du magasin à chaque machine satellite.
• L’opération d’ouverture du magasin ne peut être effectuée sur aucune machine dont le numéro terminal n’a pas encore été programmé.
• Si une erreur de transmission se produit lorsqu’une opération d’ouverture du magasin est en train d’être effectuée, l’opération d’ouverture du magasin est considérée comme s’étant normalement achevée si la fonction de réessai du système* a été désactivée par programmation. Lorsque la machine principale a été programmée pour autoriser la fonction de réessai du système, elle affichera le numéro de machine de la machine satellite qui a rencontrée cette erreur. La sélection du numéro de la machine affiché invitera à l’opération de réessai d’ouverture du magasin.
* Pour la fonction de réessai du système, voyez les pages 63–64.
NOTA
2. Opération douverture du magasin (mode OPXZ) – machines principale et satellites
7
Lorsque lopération de fermeture du magasin est effectuée à la machine principale, le système IRC est fermé. Le Terminal de Point de Vente peut envoyer une instruction AT par ce travail. Cette fonction contrôle un modem, mais na pas de fonction de contrôle sur un enregistrement et T-LOG (consignation des opérations). La procédure pour lopération de fermeture du magasin est expliquée ci-après.
Sélectionnez CLOSE STORE sur la fenêtre du mode OPXZ et appuyez sur la touche
e
.
• Vous pouvez aussi effectuer l’opération de fermeture du magasin à chaque machine satellite.
• Lorsque l’opération de fermeture du magasin est réalisée, les données restant dans les mémoires intermédiaires des consignations d’opérations (T-LOG) de toutes les machines satellites sont rassemblées par la machine principale.
• Si une erreur de transmission se produit pendant l’opération de fermeture du magasin, l’opération est considérée comme s’étant normalement achevée si la fonction de réessai du système* a été désactivée par programmation. Lorsque la machine principale a été programmée pour autoriser la fonction de réessai du système, elle affichera le numéro de machine de la machine satellite qui a rencontrée cette erreur. La sélection du numéro de la machine affiché invitera à l’opération de réessai de fermeture du magasin.
* Pour la fonction de réessai du système, voyez les pages 63–64.
NOTA
3. Opération de fermeture du magasin (mode OPXZ) – machines principale et satellites
8
Dans le système IRC, les deux types suivants de systèmes de fichiers pour employés sont disponibles: un système centralisé et un système individuel. Dans le système de fichier centralisé, la machine principale gère les données de transactions des employés à lintérieur du système IRC. Dans le système de fichier individuel, chaque machine gère les données de transactions de ses employés.
Pour choisir le type de système pour employés, consultez votre revendeur SHARP autorisé.
(1) Système dun fichier centralisé des employés
Système dun fichier centralisé des employés – sans la fonction demployés superposés
Dans ce système, chaque fichier demployés est sous le contrôle centralisé de la machine principale et la programmation pour des employés ne doit être effectuée uniquement qu’à la machine principale. Lorsquun employé entre en communication avec une machine satellite, une communication entre la machine satellite et la machine principale commencera. Vous pouvez établir un rapport qui répertorie les employés entrés en communication. (Pour plus de détails sur les rapports dentrée en communication des employés, voyez la page 11.)
Système dun fichier centralisé des employés avec la fonction demployés superposés et sans fichiers de sauvegarde des employés superposés
Dans ce système, chaque fichier demployés superposés est sous le contrôle centralisé de la machine principale et la programmation pour des employés ne doit être effectuée qu’à la machine principale. Lorsquun employé entre en communication avec une machine satellite, une communication entre la machine satellite et la machine principale commencera. Lorsque lemployé sort du système, les données de lemployé superposé sont transférées à la machine principale et sauvegardées dans son fichier demployés superposés.
Système dun fichier centralisé des employés avec la fonction demployés superposés et les fichiers de sauvegarde des employés superposés
Dans ce système, chaque fichier demployés superposés est sous le contrôle centralisé de la machine principale et la programmation pour des employés ne doit être effectuée qu’à la machine principale. La circulation des données acheminées diffère selon que lemployé est entré en communication ou pas avec la même machine satellite que celle utilisée pour une opération précédente. (Les données qui circulent dans le système comprennent non seulement les données de lemployé mais aussi les données GLU. Dans la figure de la page suivante, la circulation des données GLU est omise.)
4. Système des employés
9
1) Lorsque lemployé est entré en communication avec une machine autre que celle utilisée dans son opération précédente: Dans ce cas, les données de lemployé superposé sont envoyées de la machine principale à la machine satellite (transfert des données dun employé superposé).
2) Lorsque lemployé est entré en communication avec la même machine satellite que celle utilisée dans son opération précédente: Dans cas, aucun transfert de données ne se produit entre la machine principale et la machine satellite, mais les données mémorisées dans le fichier de sauvegarde de la machine satellite sont rappelées. Cela permet une recherche plus rapide des données que dans le cas de 1) ci-dessus.
Dans les deux cas, les données de lemployé superposé sont sauvegardées dans le fichier des employés superposés ainsi que dans le fichier de sauvegarde des données des employés superposés de la machine satellite lors de lopération dannulation dune entrée en communication.
Que le système dun fichier centralisé demployés soit utilisé avec ou sans fichier de sauvegarde demployés superposés, le fichier demployés superposés de la machine principale peut de toute manière accéder à partir de nimporte quelle machine dans le système IRC.
• Pour choisir si votre système devrait avoir ou pas la fonction d’employés superposés, et s’il devrait avoir ou pas des fichiers de sauvegarde d’employés superposés, consultez votre revendeur SHARP autorisé.
• Pour utiliser la fonction d’employés superposés dans le système IRC, la fonction d’employés superposés doit être autorisée pour toutes les machines principale et satellites.
(2) Système dun fichier individuel des employés
Dans ce système, chaque fichier demployés est sous le contrôle dune machine satellite et vous devez effectuer une programmation pour les employés à chaque machine satellite. Même si un employé programmé entre en communication avec une machine satellite, une communication avec la machine principale ne commencera pas.
Le fichier demployés superposés dans une machine satellite ne peut être accessible que par la machine satellite elle-même. Les données dans les fichiers des employés de toutes les machines satellites seront rassemblées par la machine principale chaque fois quun rapport de regroupement est établi.
NOTA
1)
2)
Machine principale
Machine satellite
Machine satellite
Fichier demployés superposés
Fichier de sauvegarde demployés superposés
Fichier demployés superposés
10
Lopération dentrée en communication est conçue pour affecter un employé à une machine (machine satellite/machine principale) et lui permettre deffectuer des opérations denregistrements sur cette machine. Si un employé entre avec succès en communication sur une machine, son code demployé apparaîtra sur laffichage à cristaux liquides de la machine.
Procédure dentrée en communication
(Cette procédure est la même que celle pour laffectation dun employé à une machine autonome.)
Affectation dun employé
Pour le système de clé demployé sans contact: Placez une clé de lemployé correspondant dans le commutateur pour employés. * La clé demployé sans contact est optionnelle.
Pour le système de clé dentrée dun employé: Appuyez sur la touche dentrée de lemployé correspondant sur le clavier.
Pour le système de clé demployé WMF (en option): Insérez la clé de lemployé WMF correspondant dans le commutateur pour employés WMF. * La clé demployé WMF nest pas un produit SHARP.
Pour le système dentrée dun code: Introduisez le code de lemployé correspondant et appuyez sur la touche
˚
. Si un code secret est programmé, la fenêtre contextuelle du code secret souvrira. Introduisez le code secret et appuyez sur la touche
e
.
• L’opération d’entrée en communication ne peut être effectuée que pour un seul employé à la fois.
• Chaque employé qui est programmé dans le système peut entrer en communication avec n’importe quelle machine satellite. (Système d’un fichier centralisé des employés)
• Lorsqu’un employé est entré en communication avec une machine en utilisant une clé d’employé sans contact, il ne pourra pas entrer en communication avec n’importe quelle autre machine placée dans le système, jusqu’à ce qu’il soit sorti du système d’entrée en communication de la machine initiale. (Système d’un fichier centralisé des employés)
• Si un employé qui est entré en communication avec une machine dans le système en utilisant un système de clé d’entrée d’un employé ou un système d’entrée d’un code, entre en communication avec n’importe quelle autre machine dans le système, il ou elle sortira automatiquement du système de la machine originale. (Système d’un fichier centralisé des employés)
• Dans le cas d’un dérangement, la condition d’entrée en communication peut être annulée à la machine principale. (Veuillez consulter votre revendeur SHARP autorisé pour plus de détails.)
Votre Terminal de Point de Vente peut permettre un système d’employé + caissier au lieu du système en cours (système d’employé seulement). Si vous désirez changer de système, veuillez consulter votre revendeur SHARP autorisé.
Affectation dun caissier (Système demployé + caissier)
Pour le système de clé dentrée dun caissier:
Appuyez sur la touche du caissier correspondant sur le clavier.
Pour le système dentrée dun code: Introduisez le code du caissier correspondant et appuyez sur la touche
j
. Si un code secret est programmé, la fenêtre contextuelle du code secret souvrira. Introduisez le code secret et appuyez sur la touche
e
.
* Pour plus de détails sur lopération dentrée en communication, voyez Affectation dun
employé” dans la section Préparatifs pour des entrées du Manuel dInstructions de UP-820F/ UP-820N.
NOTA
NOTA
5. Opération dentrée en communication (affectation dun employé) (mode REG/mode MGR)
11
Le rapport dentrée en communication dun employé peut être effectué à la machine principale. Ce rapport est utilisé pour savoir sur quelles machines les employés sont entrés en communication.
Procédure pour l’établissement dun rapport
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez READING et appuyez sur la touche
e
.
La fenêtre READING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE READING apparaîtra.
4. Sélectionnez SIGN ON CLERK et appuyez sur la touche
e
.
La fenêtre OUTPUT TO apparaîtra.
5. Sélectionnez DISPLAY ou REPORT PRINTER et appuyez
sur la touche
e
.
Nom de l’employé, code de l’employé, N° de la machine avec laquelle l’employé est entré en communication.
Exemple d’impression (machine principale)
6. Rapport dentrée en communication dun employé
12
Lopération de sortie dune entrée en communication est conçue pour annuler laffectation dun employé à une machine et terminer son opération denregistrement. Lopération de sortie dune entrée en communication à une machine (machine principale ou satellite) ne peut être réalisée que pour les employés qui sont entrés en communication avec cette machine et ne sont pas au milieu de lentrée dun enregistrement.
Procédure dannulation dune entrée en communication
Pour le système de clé demployé sans contact: Retirez la clé de lemployé sans contact. * La clé demployé sans contact est optionnelle.
Pour le système de clé dentrée dun employé: Appuyez sur la même touche dentrée de lemployé sur laquelle vous avez appuyé pour une entrée en communication.
Pour le système de clé demployé WMF (en option): Retirez la clé de lemployé WMF. * La clé demployé WMF nest pas un produit SHARP.
Pour le système dentrée dun code: Appuyez sur la touche
˚
.
• L’opération de sortie d’une entrée en communication ne peut être effectuée que pour un seul employé à la fois.
• Si un employé entre en communication avec une machine alors qu’un autre employé est déjà entré en communication avec cette machine en utilisant le système de clé d’entrée d’un employé ou le système d’entrée d’un code, l’employé préexistant sortira automatiquement du système à moins qu’il ou elle ne soit déjà à mi-parcours de l’entrée d’un article.
• Si l’opération de sortie d’une entrée en communication pour le système de clé d’employé sans contact est effectuée pendant que l’employé correspondant est encore à mi-parcours de l’entrée d’un enregistrement, l’opération s’achève automatiquement.
Votre Terminal de Point de Vente peut permettre un système d’employé + caissier au lieu du système en cours (système d’employé seulement). Si vous désirez changer de système, veuillez consulter votre revendeur SHARP autorisé.
Procédure pour la sortie dun caissier
Pour le système de clé dentrée dun caissier: Appuyez sur la même touche dentrée du caissier sur laquelle vous avez appuyé pour une entrée en communication.
Pour le système dentrée dun code: Appuyez sur la touche
j
.
NOTA
NOTA
7. Sortie du système dentrée en communication (
annulation de laffectation dun employé) (mode
REG/mode MGR)
13
Lorsque vous avez terminé la programmation à la machine principale, vous pouvez répartir les données prépositionnées de la machine principale à toutes les machines satellites ou seulement à celles souhaitées dans le système IRC.
(1) Téléchargement initial
Pour la mise en place initiale du système IRC, suivez la procédure de téléchargement ci-dessous. Lorsque les données prépositionnées dans la machine principale sont transférées à chaque machine satellite, les données préréglées existantes dans les machines satellites, sil y en a, sont effacées.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez INITIAL D/L et appuyez sur la touche
e
.
La fenêtre INITIAL D/L apparaîtra.
3. Si vous désirez répartir tous les fichiers de données
prépositionnées de la machine principale aux machines satellites, sélectionnez ALL PGM et appuyez sur la touche
e
. Si vous désirez répartir un fichier individuel de données prépositionnéees, sélectionnez larticle de données correspondant et appuyez sur la touche
e
. Si cest nécessaire, introduisez la plage des codes appropriés. La fenêtre MACHINE No apparaîtra.
4. Si vous désirez télécharger les données prépositionnées à
toutes les machines satellites, sélectionnez ALL et appuyez sur la touche
e
. Si vous désirez télécharger les données à certaine(s) machine(s) satellite(s) seulement, sélectionnez MACHINE SELECT et appuyez sur la touche
e
. Dans ce cas, la fenêtre MACHINE SELECT souvrira. Déplacez le curseur sur le(s) numéro(s) de machine(s) correspondant(s), sélectionnez YES et appuyez sur la touche
c
.
Vérifiez les contenus de la programmation de toutes les machines satellites dans le système IRC ayant reçues les données prépositionnées.
NOTA
8. Téléchargement des contenus de la programmation aux machines satellites – machine principale
14
(2) Téléchargement de mise à jour
Pour la mise à jour des données prépositionnées pour le système IRC, suivez la procédure de téléchargement ci-dessous. Les données prépositionnées dans la machine principale sont téléchargées à chaque machine satellite sans annuler les données prépositionnées existantes.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez MAINTE.D/L et appuyez sur la touche
e
.
La fenêtre MAINTE.D/L apparaîtra.
3. Sélectionnez un article de données prépositionnées pour la
mise à jour et appuyez sur la touche
e
. Introduisez une plage de codes appropriés, si cest nécessaire. La fenêtre MACHINE No apparaîtra.
4. Si vous désirez télécharger les données prépositionnées à
toutes les machines satellites, sélectionnez ALL et appuyez sur la touche
e
. Si vous désirez télécharger les données à certaine(s) machine(s) satellite(s) seulement, sélectionnez MACHINE SELECT et appuyez sur la touche
e
. Dans ce cas, la fenêtre MACHINE SELECT souvrira. Déplacez le curseur sur le(s) numéro(s) de machine(s) correspondant(s), sélectionnez YES et appuyez sur la touche
c
.
15
Liste des travaux de téléchargements (mode PGM2)
Travaux de téléchargements
Description
Données prépositionnées de rayons
Données prépositionnées de touches de rayons/PLU pour les
rayons/PLU directs
Données prépositionnées de PLU/EAN, PLU de liaison,
condiments, lancement, repas assortis, conversion de PLU,
caisses à claire-voie et textes dinformations PLU
Données prépositionnées de la touche de menus PLU
Données prépositionnées de PLU de liaison
Données prépositionnées de PLU de condiments
Données prépositionnées de conversion de EAN/ITF PLU
Données prépositionnées PLU de caisses à claire-voie
Données prépositionnées de lancements
Données prépositionnées de repas assortis
Données du format de codification de EAN non-PLU
Données du format de codification dannonce EAN
Données prépositionnées dun texte dinformations PLU
Données prépositionnées de transactions
Données prépositionnées dun texte de formation et dun
employé/N° dun caissier en formation
Données prépositionnées de la clé dun employé sans contact
et du prépositionnement dun employé
Données prépositionnées dun caissier (Seulement pour le
système caissier + employé)
Données prépositionnées du directeur
Date, heure
Autres données prépositionnées
Données prépositionnées dun message
Données prépositionnées de la touche des menus de fonction
Données prépositionnées de la configuration du dispositif
Données prépositionnées de taxes
Données prépositionnées dun client
Données prépositionnées dun nom et dune adresse
Données prépositionnées en direct
Données prépositionnées en ligne
Toutes les données prépositionnées sur le mode PGM
excepté les données prépositionnées en ligne et la
configuration du dispositif
Données prépositionnées de rayons
Données prépositionnées des prix de rayons
Données prépositionnées de PLU/EAN, PLU de liaison,
condiments, lancement, repas assortis, conversion de PLU,
caisses à claire-voie et textes dinformations PLU
Données prépositionnées de prix PLU/EAn
Données prépositionnées de PLU de liaison
Données prépositionnées de PLU de condiments
Données prépositionnées PLU de caisses à claire-voie
Données prépositionnées de lancements
Données prépositionnées de repas assortis
Données prépositionnées dun texte dinformations PLU
Données prépositionnées de transactions
INITIAL D/L
(Duplication des
données prépositionnées
avec effacement des
données existantes)
MAINTENANCE D/L
(
Duplication des
données prépositionnées
seulement)
Article
DEPT
DIRECT KEY
PLU/EAN
PLU MENU KEY
LINK PLU
CONDIMENT
PLU CONVERT
CRATE
PROMOTION
COMBO MEAL
EAN NON-PLU
PRESS CODE
PLU INFORMATION
TRANSACTION
TRAINING PRESET
CLERK
CASHIER
MANAGER
DATE/TIME
OPTION
MESSAGE
FUNC. MENU KEY
DEVICE CONFIG
TAX
CUSTOMER PRESET
NAME & ADDRESS
ONLINE PRESET
INLINE PRESET
ALL PGM
DEPT
DEPT PRICE
PLU/EAN
PLU/EAN PRICE
LINK PLU
CONDIMENT
CRATE
PROMOTION
COMBO MEAL
PLU INFORMATION
TRANSACTION
16
• Le fichier de PLU/EAN (INITIAL D/L et MAINTENANCE D/L) ne comprend pas les données d’un stock.
• Le fichier OPTION comprend les données suivantes: Prépositionnement de fonctions optionnelles, condition d’annulation EAN, prépositionnement d’une balance, ventes spéciales, omission du zéro, disposition d’un rapport general, disposition d’un rapport de transfert, disposition d’un rapport d’employe, rapport horaire, rapport d’un regroupement, alarme du tiroir, durée de sauvegarde de l’écran, client, programme de contrôle d’un client, point de prime, table de remboursements de points de primes et données prépositionnées de la touche automatique.
• Le fichier MESSAGE comprend les données suivantes: Texte d’un logotype, texte d’un groupe de rayons, texte d’un groupe de PLU, descripteur de monnaies, texte d’impression de validation, texte au bas d’une fiche, nom du prestataire, message sur l’addition de divertissements, texte d’une fiche texte d’un groupe horaire de PLU et message de défilement pour l’affichage à pôle.
• Le fichier DEVICE CONFIG comprend les données suivantes:
Imprimante de la bande de détails quotidiens, imprimante des reçus, imprimante des fiches, imprimante de rapports et imprimante de cuisine N° 1 ~ N° 9.
• Le fichier PLU/EAN (INITIAL D/L et MAINTENANCE D/L) comprend les données prépositionnées de PLU de LIAISON.
• Un téléchargement initial de toutes les données prépositionnées (ALL PGM) ne devra pas être effectué lorsque des totaux existent dans le système. (Les totalisateurs de la machine satellite réceptrice seront effacés.)
• L’exécution de travaux de téléchargements individuels provoquera une erreur de non-remise à zéro lorsque des données sur les ventes existent dans la machine satellite.
NOTA
17
Dans le système IRC, les deux types suivants dun système dattribution de fichiers GLU sont disponibles: un système centralisé et un système individuel.
Pour le choix du type de système de fichier GLU, veuillez consulter votre revendeur SHARP autorisé.
(1) Système dun fichier GLU centralisé
Dans ce système, le fichier GLU existe seulement dans la machine principale. Toutes les machines satellites dans le système IRC peuvent accéder au fichier GLU se trouvant dans la machine principale pour un enregistrement.
Le fichier GLU est sollicité par les machines satellites dans les buts suivants:
Nouvelle commande ou commande renouvelée
Entrée dun payement ou achèvement temporaire
Impression dune addition (note)
Impression dune fiche
Transfert dune addition (note)/totalisation dadditions (notes)
Quote-part dune addition (note)
Instruction (commande) dun client
Il y a deux types de transmission de données GLU:
1) Les données du GLU sont transmises de la machine principale à une machine satellite pour la
recherche dun fichier GLU (dans le cas dune nouvelle commande/commande renouvelée). Dans ce cas, le compteur de réserve* GLU est conservé à la machine principale.
* Le compteur de réserve conserve certains enregistrements des fichiers GLU pour éviter une
erreur de LACKING MEMORY (mémoire insuffisante) dans une opération dachèvement.
2) Les données du GLU sont transmises dune machine satellite à la machine principale pour
lachèvement dune opération (dans le cas de lentrée dun payement ou dun achèvement temporaire). Les données transmises de la machine satellite sont immédiatement sauvegardées dans le fichier de réception temporaire de données GLU, puis mises à jour dans le fichier GLU de la machine principale. Dans ce cas, le compteur de réserve des données GLU est effacé de la machine principale.
Si une machine satellite recherche le fichier GLU dans la machine principale ou demande à la machine principale de mettre le fichier à jour, la machine principale de sauvegarde effectue la même procédure que celle utilisée par la machine principale.
(2) Système dun fichier GLU individuel
Dans ce système, la machine principale et les machines satellites ont leurs propres fichiers GLU et les recherchent pour effectuer un enregistrement. Par conséquent, aucune communication de traitement immédiat concernant des données GLU ne sera effectuée.
9. Recherche et mise à jour dun fichier GLU
18
Dans le système IRC, les deux systèmes suivants pour le contrôle dun stock de PLU/EAN sont disponibles: un système centralisé et un système individuel.
Pour le choix du type de système de contrôle dun stock de PLU/EAN, veuillez consulter votre revendeur SHARP autorisé.
Système centralisé
Les données préréglées dun stock ne sont mémorisées que dans la machine principale. Les données dun stock dans chaque machine satellite doivent être nulles avant quune entrée de PLU/EAN ne soit effectuée. Lorsque le rapport dun regroupement est créé, les données du stock dans les machines satellites respectives sont regroupées dans le fichier du stock de la machine principale et elles y sont calculées. Les données du stock calculées à la machine principale sont affichées ou imprimées, et les données du stock dans chaque machine satellite sont en même temps remises à zéro.
Système individuel
La machine principale et les machines satellites ont leurs propres données de stocks préréglées. Lorsque le rapport dun regroupement est créé, les données du stock dans la machine principale et les machines satellites sont regroupées et affichées ou imprimées.
Dans le système individuel, le regroupement n’affecte pas les données du stock dans la machine principale.
NOTA
10. Contrôle dun stock de PLU/EAN
19
Toutes les données de transactions en mode REG dans chaque machine satellite sont sauvegardées dans sa mémoire intermédiaire T-LOG. Un appel T-LOG est un système de rassemblement des données dans lequel la machine principale rassemble les données provenant des mémoires intermédiaires T-LOG se trouvant dans les machines satellites.
Une demande pour un appel T-LOG est émise de la machine satellite vers la machine principale lorsque le nombre denregistrements des données dans sa mémoire intermédiaire T-LOG dépasse un nombre prédéterminé. Dès que la machine principale détecte une telle demande, elle commence à rassembler les données des mémoires intermédiaires T-LOG. Après le rassemblement des données dune machine satellite, la machine principale attend pendant une durée préréglée et commence le rassemblement des données à partir dune autre machine satellite. Dans un appel T-LOG, les données transmises à la machine principale sont mémorisées dans le fichier correspondant. La circulation des données dans un appel T-LOG est montrée ci-dessous.
Séquence dun appel (Voyez la figure ci-dessus.)
(1) La machine satellite A fait une demande dappel. (2) La machine principale détecte la demande et commence à collecter les données T-LOG de la
machine satellite A. (3) Les données T-LOG sont envoyées à la machine principale. (4) Après réception des données T-LOG de la machine satellite A, la machine principale attend
pendant une durée préréglée. (5) La machine principale détecte une demande provenant dune autre machine satellite (B, C ou D)
et commence à l’interroger.
Vous pouvez spécifier sur le mode PGM2 si la fonction dentrée dune machine satellite est interdite (LOCK) ou autorisée (CONTINUE) lorsque la mémoire intermédiaire T-LOG est pleine. Si elle est interdite, un message derreur T-LOG FULL sera affiché et vous ne serait pas autorisé à faire une entrée, quelle quelle soit, sur le mode REG/MGR à la machine satellite. Si elle est autorisée, vous pourrez continuer à effectuer des entrées, mais vous ne pourrez pas sauvegarder les données introduites. Même si des données sont introduites après que la mémoire intermédiaire T-LOG est devenue pleine, les données précédentes sauvegardées dans le fichier ne seront pas effacées.
• Si la mémoire intermédiaire T-LOG est presque pleine, un message d’avertissement apparaîtra sur l’affichage de la machine satellite.
• Pour la programmation si l’entrée d’un enregistrement est verrouillée ou pas lorsque le fichier T-LOG est plein, voyez “Choix d’une fonction 2” de la section “Choix de fonctions optionnelles” dans le Manuel d’Instructions de UP-820F/UP-820N.
• Pour un appel T-LOG entre la machine principale et MWS, veuillez consulter votre revendeur SHARP autorisé.
NOTA
(1) (5)
(4)
(2) (3)
Machine principale
Machine satellite A Machine satellite B Machine satellite C Machine satellite D
11. Appel des consignations dopérations (T-LOG)
20
Dans le système IRC, les deux systèmes suivants pour le contrôle des données PLU/EAN sont disponibles: un système centralisé et un système individuel.
Lors du choix du système de contrôle des données PLU/EAN, veuillez consulter votre revendeur autorisé SHARP.
Système centralisé
Les données sur les ventes PLU/EAN sont contrôlées centralement par la machine principale. Les données sur les ventes PLU/EAN qui sont temporairement mémorisées dans la mémoire intermédiaire T-LOG dune machine satellite sont envoyées à la machine principale par un appel T-LOG.
Système individuel
La machine principale et les machines satellites contrôlent individuellement leurs propres données sur les ventes PLU/EAN. Des rapports sur les ventes de PLU/EAN peuvent être individuellement produits à chaque machine. Un regroupement de données sur les ventes PLU/EAN peut être réalisé en créant un rapport PLU/EAN regroupé à la machine principale.
La fonction de formation permet à l’opérateur d’une machine satellite de régler le prix unitaire, le rayon associé et de choisir la suppression ou la non-suppression d’un article dont le code est non défini dans le fichier PLU/EAN, et d’enregistrer l’opération sur le mode de formation. (Pour plus d’informations sur la fonction de formation, voyez le Manuel d’Instructions de UP-820F/UP­820N.) Si la machine satellite n’a pas de fichier EAN dynamique, les données portées sur l’article EAN qui ont été réglées en utilisant la fonction de formation, sont mémorisées dans le fichier principal PLU/EAN pour la mise à jour du fichier. Si la machine satellite a un fichier EAN dynamique, les données sont mémorisées dans le fichier EAN dynamique pour mettre le fichier à jour. Les données qui ont été réglées en utilisant la fonction de formation sur le mode d’entraînement à une machine satellite sont aussi mémorisées dans sa mémoire intermédiaire T-LOG.
Pour la circulation des données, voyez les figures suivantes. (1) Dans le cas où la machine principale et les machines satellites nont pas de fichiers EAN dynamiques:
Fichier principal
PLU/EAN
Mémoire inter-
médiaire T-LOG
Fichier principal
PLU/EAN
Sauvegarde
Mise à jour
Machine principale Machine satellite
Enregistrement par la fonction de formation
Appel/mise à jour de T-LOG
NOTA
12. Contrôle des données PLU/EAN
21
(2) Dans le cas où la machine principale a un fichier EAN dynamique, mais que les machines satellites n’en
ont pas:
(3) Dans le cas où la machine principale ainsi que les machines satellites ont des fichiers EAN dynamiques:
Machine principale
Mise à jour des fichiers principaux PLU/EAN des machines satellites
Appel de T-LOG
Machine satellite
Enregistrement par la fonction de formation
A ce moment, tous les fichiers EAN dynamiques dans le système IRC sont effacés.
Fichier EAN
dynamique
Mise à jour
Fichier principal
PLU/EAN
Mémoire inter-
médiaire T-LOG
Fichier principal
PLU/EAN
Sauvegarde
Mise à jour
Fichier EAN
dynamique
Fichier EAN
dynamique
Machine principale
Appel de T-LOG
Mise à jour des fichiers principaux PLU/EAN des machines satellites
Mise à jour
Machine satellite
Enregistrement par la fonction de formation
Fichier principal
PLU/EAN
Mémoire inter-
médiaire T-LOG
Fichier principal
PLU/EAN
Sauvegarde
Mise à jour
22
Lorsque le prix dun article PLU/EAN est modifié à une machine (machine principale ou satellite), son fichier principal PLU/EAN ou le fichier PLU/EAN dynamique est mis à jour par les données du nouveau prix (prix unitaire et rayon associé). Immédiatement après cela, les nouvelles données sont automatiquement distribuées à toutes les autres machines pour mettre à jour les fichiers principaux PLU/EAN ou les fichiers PLU/EAN dynamiques qui contiennent le code de larticle.
Les données sur un article EAN dont le prix a été modifié sur une machine satellite sont aussi mémorisées dans la mémoire intermédiaire T-LOG de la machine satellite. Les données mémorisées dans la mémoire intermédiaire T-LOG sont collectées par un appel de T-LOG à la machine principale pour mettre à jour son fichier principal PLU/EAN ou le fichier EAN dynamique. Pour plus dinformations sur la fonction de changement dun prix, voyez le Manuel dInstructions de UP­820F/UP-820N.
Pour la circulation des données, voyez les figures suivantes.
Dans le cas où le prix est changé à la machine principale:
Dans le cas où le prix est changé à une machine satellite:
Si une erreur de transmission survient pendant une distribution automatique de données de mise à jour à d’autres machines, après le changement d’un prix en utilisant la fonction de changement d’un prix à une machine, le numéro de machine du terminal qui est l’origine de l’erreur et le type d’erreur seront imprimés sur la machine qui envoie. Dans ce cas, la fonction de réessai du système peut être utilisée si elle est autorisée. (Pour la fonction de réessai du système, voyez à la pages 63–64.)
Dans le système IRC, les données du client sont centralisées et contrôlées par la machine principale. Les données du client, qui sont temporairement mémorisées dans la mémoire intermédiaire T-LOG dune machine satellite, sont envoyées à la machine principale par un appel de T-LOG et contrôlées par la machine principale. (Pour plus dinformations sur un appel T-LOG, voyez la page 19.)
14. Contrôle des données d’un client
NOTA
Machine principale
Machine satellite
D
onnées de changement de prix (prix unitaires et rayons associés)
Appel de T-LOG et mise à jour
Distribution automatique de données de mise à jour à la machine principale et à toutes les autres machines satellites
Sauvegarde
Mise à jour
Fichier EAN
dynamique
Fichier principal
PLU/EAN
Mémoire inter-
médiaire T-LOG
Fichier principal
PLU/EAN
Fichier EAN
dynamique
Machine principale
Machine satellite
Distribution automatique de données de mise à jour à toutes les machines satellites
Enregistrement par la fonction de changement dun prix
Fichier EAN
dynamique
Fichier principal
PLU/EAN
Mémoire inter-
médiaire T-LOG
Fichier principal
PLU/EAN
Fichier EAN
dynamique
13. Fonction de changement dun prix
23
Lorsquune imprimante à distance est comprise dans le système en ligne, les données dinstructions sont délivrées à limprimante à distance selon son affectation.
Limprimante à distance, appelée aussi imprimante de cuisine, est utilisée pour imprimer la totalité ou une partie des données introduites dans la machine. Limprimante à distance peut aussi être utilisée dans un endroit autre quune cuisine.
Si une imprimante à distance est affectée à un rayon ou un PLU, les informations sur le rayon ou le PLU sont délivrées à limprimante à distance lorsque lon appuie sur la touche
ı
ou fou lorsque lopération est achevée à un terminal. Les données qui peuvent être délivrées à une imprimante à distance sont les suivantes:
1) Texte dun article
2) Quantité*
3) Prix unitaire*/Prix*
4) Montant*
5) Code du PLU/rayon*
6) Texte disponible*
7) Nombre de clients*
* Une impression ou non est sélectionnable.
Seconde imprimante à distance (sauvegarde)
Une seconde imprimante à distance peut être affectée à chaque imprimante à distance pour une sauvegarde automatique. Si une erreur se produit pendant que des données sont délivrées à une imprimante à distance, les données seront délivrées à la seconde imprimante à distance qui lui est affectée. Si une erreur se produit pendant que des données sont délivrées à la seconde imprimante à distance, les données seront délivrées à limprimante pour reçus du terminal.
Jusqu’à deux imprimantes à distance peuvent être préréglées pour une impression de données sur chaque article (PLU ou rayon). Si deux imprimantes sont préréglées pour imprimer des données sur chaque article, les données sont simultanément délivrées aux deux imprimantes. Si lune des ces imprimantes rencontre une erreur, les données seront délivrées à son imprimante de sauvegarde. Si limprimante de sauvegarde rencontre une erreur, un reçu est imprimé.
• Pour la programmation des imprimantes à distance, voyez les pages 47–50.
• Une entrée de caisses à claire-voie n’est pas délivrée à une imprimante à distance.
NOTA
15. Communication avec une imprimante à distance (en option)
24
Dans les contextes dutilisation dun restaurant ou dautres endroits similaires, chaque terminal na pas besoin dune imprimante extérieure (imprimante dadditions, imprimante de validation ou imprimante de cuisine). Une imprimante extérieure raccordée au moyen du câble RS-232 peut être utilisée en commun par deux ou davantage de machines UP-820F/UP-820N.
Diagramme du réacheminement des données dimpression
Données de réacheminement au diagramme de limprimante incorporée
UP-820F/UP-820N
UP-820F/UP-820N
Sortie à limprimante
incorporée
via LAN
via le câble RS-232
UP-820F/UP-820N
UP-820F/UP-820N
UP-820F/UP-820N
Circulation des données de réacheminement
Données dimpression (1)
Données dimpression (2)
Données dimpression (1)
Imprimante extérieure
Imprimante extérieure
Circulation normale des données
16. Réacheminement des données dimpression
25
2
Rapports regroupés et individuels
Ce système peut établir deux types de rapports sur des ventes: des rapports regroupés (rapports pour toutes les machines ou pour des machines spécifiées dans le système) et des rapports individuels (rapports pour une machine individuelle). A la machine principale, vous pouvez obtenir des rapports regroupés pour toutes les machines ou pour des machines satellites spécifiées, ainsi que des rapports pour la machine principale elle-même. A chaque machine satellite, vous pouvez obtenir des rapports individuels de la machine satellite.
Mode X1/Z1: Rapports de lectures (X1) et de remises à zéro (Z1) sur des ventes quotidiennes. Mode X2/Z2: Rapports de lectures (X2) et de remises à zéro (Z2) de regroupements périodiques. Mode OPXZ: Rapports de lectures (X) et de remises à zéro (Z) sur les ventes quotidiennes dun employé/caissier individuel.
1. Modes dexploitation
26
(1) Procédure pour l’établissement dun rapport
Pour établir des rapports variés, utilisez la procédure suivante en vous référant à la liste des rapports regroupés dans les pages suivantes.
1. Introduisez le mode dexploitation requis (OPXZ, X1/Z1 ou
X2/Z2) à partir de la fenêtre de sélection du mode.
2. Selon vos besoins, sélectionnez SYSTEM READING ou
SYSTEM RESETTING et appuyez sur la touche
e
.
3. Sélectionnez le type de rapport que vous désirez établir et
appuyez sur la touche
e
ou introduisez le N° (2 chiffres) du type de rapport correspondant montré sur laffichage. En sélectionnant un article indiqué entre parenthèses sur l’écran douverture et en appuyant sur la touche
e
, vous pouvez sauter jusqu’à la liste du rapport recherché. (Si le type du rapport désiré nest pas répertorié sur laffichage, faites défiler vers le haut ou vers le bas l’écran daffichage avec les touches de défilement.)
4. Si vous avez besoin dintroduire des données pour établir un
rapport, suivez les instructions données sur laffichage concernant une entrée. La fenêtre MACHINE No. apparaîtra.
5. Si vous désirez établir un rapport de toutes les machines du
système, sélectionnez ALL et appuyez sur la touche
e
. Si vous désirez établir un rapport pour des machines spécifiées, sélectionnez MACHINE SELECT et appuyez sur la touche
e
. Dans ce cas, la fenêtre MACHINE SELECT souvrira. Déplacez le curseur sur le numéro de la machine, sélectionnez YES et appuyez sur la touche
c
.
La fenêtre OUTPUT TO apparaîtra.
6. Sélectionnez DISPLAY ou REPORT PRINTER et appuyez
sur la touche
e
.
2. Rapports regroupés – machine principale et machine principale de sauvegarde
27
(2) Liste de rapports regroupés (SYSTEME DE LECTURE ET DE
REMISE A ZERO)
OPXZ X1/Z1 X2/Z2
Type de rapport Description
Modes dexploitation
Données requises/Remarques
Rapport général
Rapport sur des rayons groupés
Rapport sur un groupe de rayons individuels Rapport sur la totalité des groupes de rayons
Rapport sur des ventes PLU/EAN sur une plage spécifiée
Rapport de codes PLU/EAN recueilli Rapport sur des ventes assorties de PLU
Rapport sur des ventes assorties de codes recueillis Rapport de PLU/EAN sur un rayon spécifié Rapport de PLU/EAN sur un groupe individuel Rapport sur la totalité des groupes PLU/EAN Rapport sur un stock de PLU/EAN
Rapport sur un stock de PLU/EAN recueilli Rapport sur les 20 meilleures ventes de PLU par montant des ventes Rapport sur les 20 meilleures vente de PLU par la quantité des ventes Rapport sur des ventes nulles de PLU/EAN Rapport sur des ventes nulles de PLU/EAN par rayon spécifié Rapport sur un stock minimum de PLU/EAN
Rapport sur des ventes de PLU/EAN par catégorie de prix Totalité des groupes de PLU par rapport horaire
Rapport sur des opérations Rapport sur le total en caisse Rapport sur des ventes à la commission Rapport sur des taxes Rapport du chef de salle
Code du rayon (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) N° du groupe de rayons (1 à 17)
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code de PLU/EAN recueilli Code du PLU (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code de PLU/EAN recueilli
Code du rayon
N° du groupe de PLU/EAN
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code des PLU/EAN recueillis
Code du rayon
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Catégorie de prix de PLU/EAN
Plage horaire
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X1,Z1
X1
X1
X1
X1,Z1
X1,Z1
X1
X1
X1,Z1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1,Z1
X1 X1 X1 X1 X1
X2,Z2
X2
X2
X2
X2,Z2
X2,Z2
X2
X2
X2,Z2
X2
X2
-
-
X2
X2
X2
X2
-
X2
-
X2 X2 X2
X2
-
GENERAL
<DEPARTMENT>
DEPT./GROUP
DEPT. IND. GROUP
DEPT. GROUP TOTAL
<PLU>
PLU
PLU PICKUP COMBO SALES
COMBO PICKUP
PLU BY DEPT.
PLU IND. GROUP
PLU GROUP TOTAL
PLU STOCK
PLU STOCK PICKUP
PLU TOP 20
PLU ZERO SALES
PLU MINIMUM STOCK
PLU PRICE CATEGORY
PLU HOURLY GROUP
<TRANSACTION>
TRANSACTION TL-ID COMMISSION SALES TAX CHIEF
28
OPXZ X1/Z1 X2/Z2
Type de rapport Description
Modes dexploitation
Données requises/Remarques
Rapport sur lensemble des employés Rapport sur un employé individuel Rapport sur lensemble des
caissiers Rapport sur un caissier individuel
Rapport dun employé
Rapport sur lajustement dun employé
Rapport sur la condition active dun employé
Rapport sur les heures supplémentaires dun employé
Rapport horaire (sur une plage spécifiée)
Rapport horaire (totalité) Rapport sur un total net quotidien Rapport sur le % du coût du travail Rapport sur des GLU
Rapport sur des GLU par un employé
Rapport dun solde Rapport sur des additions (notes) Rapport sur des ventes à un client
Rapport 1 sur des ventes à un client (Seulement les détails)
Rapport 2 sur des ventes à un client (Détails/montant et total)
Rapport sur des ventes à un client (sur une plage de ventes spécifiée)
Rapport dun crédit dachats à un client (Rapport sur un non payement du client)
Rapport sur linstruction dun client
Rapport regroupé 1 Rapport regroupé 2
Seulement pour le système de caissier + employé
Code du caissier Seulement pour le système de caissier + employé
Code de lemployé (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Code de lemployé (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Code de lemployé (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Code de lemployé (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Plage horaire
Code du GLU (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Seulement pour le système de fichier GLU centralisé
Seulement pour le système de fichier GLU centralisé
Code du client (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Code du client (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Code du client (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
Plage des ventes à un client
Code dinstruction du client (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
-
X,Z
-
X,Z
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X1,Z1 X1,Z1 X1,Z1
X1,Z1
-
-
-
-
X1
X1,Z1
-
X1
X1,Z1
X1,Z1
X1
X1,Z1
-
-
-
-
-
-
X1,Z1
X2,Z2 X2,Z2 X2,Z2
X2,Z2
X2,Z2
X2
X2
X2,Z2
-
-
X2,Z2
-
-
-
X2
-
X2
Z2
Z2
X2
X2
X2,Z2
X2,Z2
<PERSONNEL>
ALL CLERK IND. CLERK ALL CASHIER
IND. CASHIER
EMPLOYEE
EMP. ADJUSTMENT
EMP. ACTIVE STATUS
EMP. OVER TIME
<OTHERS>
HOURLY
DAILY NET LABOR COST% GLU
GLU BY CLERK
BALANCE BILL CUSTOMER SALES
CUSTOMER SALES 1
CUSTOMER SALES 2
CUSTOMER BY AMT
CHARGE ACCOUNT
CUSTOMER ORDERING
STACKED REPORT
29
(1) Procédure pour l’établissement dun rapport
Pour établir des rapports variés, utilisez la procédure suivante en vous référant à la liste des rapports individuels dans les pages suivantes.
1. Introduisez le mode dexploitation requis (OPXZ, X1/Z1 ou
X2/Z2) à partir de la fenêtre de sélection du mode.
2. Selon vos besoins, sélectionnez READING ou
RESETTING et appuyez sur la touche
e
.
3. Sélectionnez le type de rapport que vous désirez établir et
appuyez sur la touche
e
ou introduisez le N° (2 chiffres) du type de rapport correspondant montré sur laffichage. En sélectionnant un article indiqué entre parenthèses sur l’écran douverture et en appuyant sur la touche
e
, vous pouvez sauter jusqu’à la liste du rapport recherché. (Si le type du rapport désiré nest pas répertorié sur laffichage, vous pouvez faire défiler vers le haut ou vers le bas l’écran daffichage avec les touches de défilement.)
4. Si vous avez besoin dintroduire des données pour établir un
rapport, suivez les instructions données sur laffichage concernant une entrée.
La fenêtre OUTPUT TO apparaîtra.
5. Sélectionnez DISPLAY ou REPORT PRINTER et appuyez
sur la touche
e
.
Selon vos réglages IRC pour les articles (système de fichiers des employés, etc.) nécessitant la sélection de fichiers centralisés ou individuels, les types de rapports émissibles varient. Pour plus de détails, veuillez consulter votre revendeur SHARP autorisé.
NOTA
3. Rapports individuels – machine principale, machine principale de sauvegarde et machines satellites
30
(2) Liste de rapports individuels (LECTURE ET REMISE A ZERO)
OPXZ X1/Z1 X2/Z2
Type de rapport Description
Modes dexploitation
Données requises/Remarques
Rapport général
Rapport sur des rayons groupés
Rapport sur un groupe de rayons individuels Rapport sur la totalité des groupes de rayons
Rapport sur des ventes PLU/EAN sur une plage spécifiée
Rapport de codes PLU/EAN recueilli Rapport sur des ventes assorties de PLU
Rapport sur des ventes assorties de codes recueillis Rapport de PLU/EAN sur un rayon spécifié Rapport de PLU/EAN sur un groupe individuel Rapport sur la totalité des groupes PLU/EAN Rapport sur un stock de PLU/EAN
Rapport sur un stock de PLU/EAN recueilli Rapport sur les 20 meilleures ventes de PLU par montant des ventes Rapport sur les 20 meilleures vente de PLU par la quantité des ventes Rapport sur des ventes nulles de PLU/EAN Rapport sur des ventes nulles de PLU/EAN par rayon spécifié Rapport sur un stock minimum de PLU/EAN
Rapport sur des ventes de PLU/EAN par catégorie de prix Totalité des groupes de PLU par rapport horaire
Rapport sur des opérations Rapport sur le total en caisse Rapport sur des ventes à la commission Rapport sur des taxes Rapport du chef de salle
Code du rayon (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) N° du groupe de rayons (1 à 17)
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code de PLU/EAN recueilli Code du PLU (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code de PLU/EAN recueilli
Code du rayon
N° du groupe de PLU/EAN
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Code du PLU/EAN recueillis
Code du rayon
Code du PLU/EAN (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Catégorie de prix de PLU/EAN
Plage horaire
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X1,Z1
X1
X1
X1
X1,Z1
X1,Z1
X1
X1
X1,Z1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1,Z1
X1 X1 X1 X1 X1
X2,Z2
X2
X2
X2
X2,Z2
X2,Z2
X2
X2
X2,Z2
X2
X2
-
-
X2
X2
X2
X2
-
X2
-
X2 X2 X2 X2
-
GENERAL
<DEPARTMENT>
DEPT./GROUP
DEPT. IND. GROUP
DEPT. GROUP TOTAL
<PLU>
PLU
PLU PICKUP COMBO SALES
COMBO PICKUP
PLU BY DEPT.
PLU IND. GROUP
PLU GROUP TOTAL
PLU STOCK
PLU STOCK PICKUP
PLU TOP 20
PLU ZERO SALES
PLU MINIMUM STOCK
PLU PRICE CATEGORY
PLU HOURLY GROUP
<TRANSACTION>
TRANSACTION TL-ID COMMISSION SALES TAX CHIEF
31
OPXZ X1/Z1 X2/Z2
Type de rapport Description
Modes dexploitation
Données requises/Remarques
Rapport sur lensemble des employés
Rapport sur un employé individuel
Rapport sur lensemble des caissiers
Rapport sur un caissier individuel
Rapport horaire (sur une plage spécifiée)
Rapport horaire (totalité) Rapport sur un total net quotidien Rapport sur des GLU
Rapport sur des GLU par un employé
Rapport sur des soldes Rapport sur linstruction dun client
Rapport regroupé 1 Rapport regroupé 2 Bande de détails quotidiens
électronique
Seulement pour le système de fichier dun employé individuel
Seulement pour le système de fichier dun employé individuel
Seulement pour le système de caissier + employé
Code du caissier Seulement pour le système de caissier + employé
Plage horaire
Code du GLU (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.) Seulement pour le système dun fichier GLU individuel
Seulement pour le système dun fichier GLU individuel
Code dinstruction du client (La plage peut être spécifiée en introduisant les codes de démarrage et dachèvement.)
-
X,Z
-
X,Z
-
-
-
-
-
-
-
-
X,Z
X1,Z1
X1,Z1
X1,Z1
X1,Z1
X1
X1,Z1
-
X1,Z1
X1,Z1
X1
-
X1,Z1
X1,Z1
X2,Z2
X2,Z2
X2,Z2
X2,Z2
-
-
X2,Z2
-
-
X2
X2,Z2
X2,Z2
-
<PERSONNEL>
ALL CLERK
IND. CLERK
ALL CASHIER
IND. CASHIER
<OTHERS>
HOURLY
DAILY NET GLU
GLU BY CLERK
BALANCE CUSTOMER ORDERING
STACKED REPORT
E. JOURNAL
32
Dans un système qui na pas de fichier de sauvegarde et qui a été programmé de manière à verrouiller automatiquement les machines satellites après une remise à zéro, lorsquun rapport de remise à zéro générale, de remise à zéro horaire, de remise à zéro des caissiers ou de remise à zéro de totaux nets quotidiens est réalisé, les données se trouvant dans les machines satellites concernées ne sont pas effacées. En ce cas, les machines satellites seront verrouillées après une remise à zéro, et aucune entrée ny sera autorisée sur le mode REG/MGR. L’établissement d’un même rapport de remise à zéro dans une condition de verrouillage imprimera un symbole de copie sur le rapport. Les machines satellites peuvent être déverrouillées en établissant un rapport de remise à zéro regroupé à la machine principale ou par annulation manuelle des mémoires sur les ventes effectuées par les machines satellites.
Votre revendeur peut programmer sil y a ou non des fichiers de sauvegarde et si les machines satellites sont verrouillées ou non. Pour plus de détails, consultez votre revendeur SHARP autorisé.
4. Rapports de remise à zéro dans un système sans fichier de sauvegarde
33
Comme il est mentionné plus haut (voir la page 8), il existe deux systèmes pour un rassemblement des données sur les ventes par un employé: un système centralisé et un système individuel.
(1) Système dun fichier centralisé des employés
Dans ce système, les données sur les opérations dun employé dans chaque machine satellite seront transmises à la machine principale chaque fois que cet employé quitte le système. Vous ne pouvez établir un rapport sur un employé individuel pour chaque machine satellite. A la machine principale, vous pouvez établir des rapports regroupés de lensemble des employés et dun employé individuel. A chaque machine satellite, vous pouvez établir des rapports de regroupement dun employé individuel.
Si une opération de remise à zéro pour un rapport Z regroupé dun employé individuel est établi à une machine satellite où un employé est entré en communication, les données sur lopération ayant été traitée par lemployé ou le caissier seront aussi ajoutées et imprimées.
Si un rapport Z de lensemble des employés est établi à la machine principale alors quun employé est entré en communication avec une machine satellite, ces données sur les ventes de lemployé seront exclues du rapport et une opération de remise à zéro pour lemployé ne pourra être réalisée.
Exemple dun rapport de lensemble des employés dans le système dun fichier demployés centralisé (machine principale)
Pour des informations détaillées sur des articles de rapports, voyez le Manuel d’Instructions UP­820F/UP-820N.
NOTA
N° de la machine N° consécutif Date
Type de rapport
Code de lemployé Nom de lemployé
Données sur lemployé N° 0001
Mode du rapport
Données sur lemployé N° 0002 (Si le rapport est effectué avec lemployé N° 2 entré en communication avec une machine satellite, les données sur lemployé ne seront pas imprimées.)
Compteur de remise à zéro
Heure
5. Rapport dun employé
34
(2) Système dun fichier individuel des employés
Dans ce système, vous pouvez établir des rapports X ou Z regroupés de lensemble des employés ou dun employé individuel à la machine principale seulement. A chaque machine, vous pouvez établir un rapport X ou Z sur des opérations faites par un employé individuel ou par un caissier affecté à cette machine.
Si le système na pas de fichier de sauvegarde, lemployé pour qui un rapport Z a été établi nest pas autorisé à effectuer des enregistrements sur le mode REG. Cette condition, dans laquelle des enregistrements réalisés par lemployé sont interdits, est annulée lorsque ses données sur les ventes sont regroupées et remises à zéro à la machine principale ou lorsque les données sur les ventes sont annulées manuellement. (Pour une opération deffacement manuelle, voyez les pages 61 ~ 62.)
Lorsquun rapport X ou Z pour lemployé évincé est établi à nouveau, le symbole COPY sera imprimé sur le rapport, comme il est montré ci-dessous. (Ce symbole COPY napparaîtra pas lorsque le système a un fichier de sauvegarde.)
Exemple dun rapport de lensemble des employés dans le système dun fichier demployés individuel (machine principale)
• Pour sélectionner si votre système doit avoir un fichier de sauvegarde, consultez votre revendeur SHARP autorisé.
• Pour le réglage de l’annulation des données d’une remise à zéro individuelle au moment de la remise à zéro d’un regroupement des totaux quotidiens, veuillez consulter votre revendeur SHARP autorisé.
NOTA
Symbole de copie
Symbole de copie
35
La méthode de gestion des fichiers dun caissier dans le système IRC emploie un système non centralisé ou individuel. Un caissier qui est affecté à une machine peut effectuer des enregistrements et dautres opérations à cette machine. Dans ce système, vous pouvez établir des rapports X ou Z regroupés pour un caissier individuel ou pour lensemble des caissiers à la machine principale seulement. A chaque machine, vous pouvez établir un rapport X ou Z individuel sur des opérations effectuées par le(s) caissier(s) affecté(s) à cette machine.
Si le système na pas de fichier de sauvegarde, le caissier pour qui un rapport Z a été établi nest pas autorisé à effectuer des enregistrements sur le mode REG. Cette condition, dans laquelle des enregistrements réalisés par le caissier sont interdits, est annulée lorsque ses données sur les ventes sont regroupées et remises à zéro à la machine principale ou lorsque les données sur les ventes sont annulées manuellement. (Pour une opération deffacement manuelle, voyez les pages 61–62.) Lorsquun rapport X ou Z pour le caissier évincé est établi à nouveau, le symbole COPY sera imprimé sur le rapport. (Ce symbole COPY napparaîtra pas lorsque le système a un fichier de sauvegarde.)
Lorsque le système a un fichier de sauvegarde, les données dans le fichier de sauvegarde et celles dans le fichier des ventes sont totalisées pour un regroupement.
• Les explications données ci-dessus s’appliquent lorsque le système de caissiers est utilisé en plus du système des employés. Pour une sélection du système caissier + employé ou employé seulement, veuillez consulter votre revendeur SHARP autorisé.
• Pour le réglage de l’annulation des données d’une remise à zéro individuelle au moment de la remise à zéro d’un regroupement des totaux quotidiens, veuillez consulter votre revendeur SHARP autorisé.
NOTA
6. Rapport dun caissier
36
Chaque machine peut être programmée pour autoriser la fonction de déclaration obligatoire de liquidités/ chèques (CCD). Cette fonction contraint lopérateur à introduire le montant des liquidités/chèques dans le tiroir juste avant quun rapport Z demployé/caissier individuel ou quun rapport général ne soit imprimé.
Pour établir un rapport Z général dans le cas dune fonction de déclaration obligatoire de liquidités/chèques (CCD), les deux conditions suivantes doivent être appliquées.
1) Si CCD DATA (données CCD) nest pas introduit dans la machine principale et que la machine principale est inclue dans un rendez-vous avec le numéro dune machine, lensemble des rapports de regroupements sur le mode X1/Z1 ne sera pas exécuté.
2) Si CCD DATA (données CCD) nest pas introduit dans une machine satellite, lensemble des rapports de regroupements ne sera pas exécuté.
Dans le cas du système dun fichier demployés individuels, vous navez pas besoin deffectuer une entrée CCD à la machine principale avant la création dun rapport de regroupement. Le rapport établi comprendra les données regroupées des entrées CCD qui ont été faites pour établir des rapports individuels.
A moins que des entrées CCD naient été effectuées à la machine principale et à toutes les machines satellites dans le système IRC pour établir des rapports individuels, vous ne pouvez pas créer un rapport de regroupement à la machine principale.
Vous ne pouvez pas créer certains types de rapports conformément au tableau ci-dessous. (Pour plus de détails sur cette fonction, voyez le Manuel dInstructions UP-820F/UP-820N.)
Liste de rapports regroupés dans le cas dun système daffectation du fichier dun employé individuel (à la machine principale)
• Pour plus de détails sur l’entrée de chaque CCD, voyez le Manuel d’Instructions de la UP­820F/UP-820N.
• Pour le choix du type de déclaration liquidités/chèques obligatoire, veuillez consulter votre revendeur SHARP autorisé.
NOTA
: L’établissement dun rapport nest pas autorisé. : L’établissement dun rapport est autorisé.
* : Des entrées CCD peuvent être effectuées à la machine principale et à toutes les machines satellites pour autoriser
l’établissement dautres rapports individuels correspondants.
Employé/Caissier
Rapport dun employé/
caissier individuel
Rapport général Autres rapports
Non-obligatoire
Par employé/caissier
Par terminal (par changement)
X
*
Z X
*
ZXZ
Type de rapport
Programmation dune entrée CCD
7. Rapports qui peuvent être établis lorsque la fonction de déclaration obligatoire de liquidités/chèques (CCD) est autorisée
37
Même lorsquune machine a été programmée pour ne pas autoriser des entrées après une remise à zéro totale de tous les articles ou quelle na pas été programmée pour autoriser automatiquement une opération dannulation de la mémoire dune remise à zéro individuelle au moment dune remise à
zéro générale du
total quotidien dun regroupement, vous pouvez déverrouiller la machine par lintermédiaire
dune opération
deffacement de la remise à zéro, de manière à faire redémarrer des entrées.
1. Introduisez le mode X1/Z1 ou X2/Z2 à partir de la fenêtre de
sélection du mode.
2. Sélectionnez RESET CLEAR (effacement dune remise à
zéro) et appuyez sur la touche
e
.
La fenêtre MACHINE No apparaîtra.
3. Si vous désirez déverrouiller lensemble des machines
entrées dans le système, sélectionnez ALL et appuyez sur la touche
e
. Si vous désirez déverrouiller des machines spécifiques, sélectionnez MACHINE SELECT (sélection de machines) et appuyez sur la touche
e
. Dans ce cas, la
fenêtre MACHINE SELECT souvrira.
Déplacez le curseur sur le(s) numéro(s) de machine(s)
correspondant(s), sélectionnez YES et appuyez sur la touche
c
.
8. Opération deffacement dune remise à zéro (modes X1/Z1 et X2/Z2) – machine principale
38
3
Programmation du système IRC (communication directe entre enregistreuses)
Pour faire démarrer la programmation IRC, mettez tout dabord les machines se trouvant dans le système IRC sous tension et placez-les sur le mode PGM2. Les procédures de programmation pour la machine principale et les machines satellites sont expliquées ci-dessous.
Pour le réglage de votre système IRC, veuillez vous assurer de consulter votre revendeur SHARP autorisé.
Avant la programmation, il est nécessaire dattribuer des numéros de machine à la machine principale et aux machines satellites.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez TERMINAL et appuyez sur la touche
e
.
La fenêtre TERMINAL apparaîtra.
4. Déplacez le curseur sur la ligne MACHINE#.
Introduisez un numéro de machine et appuyez sur la touche
c
.
Numéro de machine: jusqu’à 6 chiffres (0 ~ 999999)
5. Répétez les étapes 1 à 4 pour toutes les machines se
trouvant dans le système IRC.
• Dans un réseau IRC, chaque numéro de machine doit être unique. N’utilisez pas le même numéro pour deux ou davantage de machines.
• Assurez-vous de régler tout d’abord les machines satellites pour permettre le téléchargement du prépositionnement de traitement immédiat de la machine principale aux machines satellites.
NOTA
1. Réglage des numéros de machines – machines principale et satellites
39
Pour le réglage de votre système IRC, veuillez vous assurer de consulter votre revendeur SHARP autorisé. Il est supposé que vos terminaux IRC ont déjà été réglés pour des opérations de traitement immédiat.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne IP ADDRESS 4.
Introduisez un numéro de terminal (0 ~ 254) et appuyez sur la touche
c
.
[Pour la programmation de la fonction de SYSTEM RETRY (réessai du système) et de LOOKUP ORDER (instruction pour une recherche), voyez les pages 43 ~ 44.]
5. Répétez les étapes 1 à 4 pour toutes les machines se
trouvant dans le système IRC.
• Des numéros terminaux doivent être attribués à la machine principale et à chaque machine satellite se trouvant dans le système IRC. (Pour le réglage du numéro terminal de la machine principale, voyez le paragraphe suivant.)
• Si un réseau IRC contient deux ou davantage de machines ayant le même numéro terminal, les communications IRC ne pourront être réalisées correctement. Chaque numéro terminal doit être unique.
• Le numéro terminal doit se trouver dans une plage de 1 à 254.
• Si le numéro terminal “000” est programmé pour une machine, il sera placé sur le mode OFF LINE et ne pourra participer à des communications IRC.
NOTA
2. Réglage des numéros terminaux (numéros de machines IRC) pour les machines satellites
40
Pour le réglage de votre système IRC, veuillez vous assurer de consulter votre revendeur SHARP autorisé.
(1) Réglage du numéro terminal pour la machine principale et
création de la liste principale
Une liste principale ne peut être créée que sur la machine principale prédésignée.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Introduisez un numéro terminal (0 ~ 254) pour la machine
principale dans la ligne IP ADDRESS 4 et effectuez la programmation pour BMA MACHINE No*, la fonction SYSTEM RETRY* et LOOKUP ORDER*, puis appuyez sur la touche
e
.
La fenêtre MASTER LIST apparaîtra.
[* Pour la programmation de BMA MACHINE No, la fonction de SYSTEM RETRY (réessai du système) et de LOOKUP ORDER (instruction pour une recherche), voyez les pages 42 ~ 44.]
5. Introduisez le numéro terminal (1 ~ 254) pour une machine
dans le système IRC et appuyez sur la touche
e
.
La ligne du numéro de la machine apparaîtra.
6. Introduisez le numéro de machine (1 ~ 999999) de la
machine et appuyez sur la touche
e
.
7. Répétez les étapes 5 à 6 pour toutes les machines se
trouvant dans le système IRC. Appuyez sur la touche
c
pour compléter la liste principale.
3. Réglage initial pour la machine principale et création/mise à jour de la liste principale
41
• Les numéros terminaux et les numéros de machines de la machine principale et des machines satellites doivent être introduits dans la liste principale pour des communications IRC.
• Les numéros terminaux et les numéros de machines de jusqu’à 32 machines (une principale et 31 satellites) peuvent être introduits dans la liste principale.
• Le numéro terminal devra se trouver dans une plage allant de 1 à 254 et le numéro de la machine dans une plage de 1 à 999999.
• Aucune machine satellite ne peut effectuer de communications de traitement immédiat, à moins que son numéro terminal et son numéro de machine ne soient présents dans la liste principale.
• Si un numéro de machine existant déjà dans la liste principale est introduit, une erreur d’entrée se produira même lorsque le numéro terminal correspondant n’existe pas dans la liste.
• Même si un ensemble de numéros terminaux et de machines qui existe dans la liste principale est introduit, aucune erreur ne se produira (la liste restera inchangée).
(2) Suppression dune machine de la liste principale
Pour annuler un numéro terminal de la liste principale, procédez de la manière suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection du mode.
2. Sélectionnez SETTING sur le mode PGM2 et appuyez sur la touche
e
. La fenêtre SETTING
apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
. La fenêtre INLINE CONFIG
apparaîtra.
4. Appuyez sur la touche
c
. La fenêtre MASTER LIST apparaîtra.
5. Introduisez le numéro terminal devant être annulé et appuyez sur la touche D.
6. La machine vous demandera: ARE YOU SURE?” (Etes-vous sûr ?). Si vous êtes certain de cette annulation, sélectionnez YES. Dans le cas contraire, sélectionnez NO”.
7. Appuyez sur la touche
c
pour compléter la liste principale.
• Vous pouvez annuler n’importe quel numéro terminal qui se trouve dans la liste principale.
• L’annulation de la machine principale de la liste principale interdira à toutes les demandes des machines satellites d’être envoyées.
NOTA
NOTA
42
Vous pouvez affecter une machine satellite à la fonction de machine principale de sauvegarde. Si la machine principale tombe en panne pendant une opération de vérification dun client, la machine de sauvegarde se chargera deffectuer les fonctions de la machine principale. Un numéro de machine de 1 à 999999 peut être introduit. Lintroduction dun zéro interdira la fonction de machine principale de sauvegarde dans le système IRC. Cette affectation peut être faite dans la fenêtre de INLINE CONFIG de la machine principale. Pour déterminer si votre système IRC doit avoir une machine principale de sauvegarde ou pas, veuillez consulter votre revendeur SHARP autorisé.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne BMA MACHINE.
Introduisez le numéro de machine du terminal servant en tant que machine principale de sauvegarde et appuyez sur la touche
c
.
Pour déterminer quelle machine satellite devra être choisie pour BMA MACHINE No, veuillez consulter votre revendeur SHARP autorisé.
Les fonctions de DECLARATION sur le mode PGM2 permettent à la machine principale de sauvegarde ou à la machine principale de déclarer servir en tant que machine principale lorsque la machine principale ou la machine principale de sauvegarde tombe en panne, et d’informer les machines satellites de la machine principale ou de la machine principale de sauvegarde de la reprise de l’exploitation. Si la machine principale et la machine principale de sauvegarde communiquent mutuellement sans problème, il ne sera pas nécessaire d’effectuer une “déclaration de la machine principale” à la machine principale ou à la machine principale de sauvegarde. Sinon, la communication entre elles sera interrompue. Pour les détails sur ces fonctions, voyez “Déclaration de la machine principale” et “Déclaration de reprise” aux pages 55 ~ 60.
NOTA
4. Désignation du terminal pour servir en tant que machine principale de sauvegarde – machine principale
43
Vous pouvez spécifier si la fonction de réessai du système est autorisée ou pas lorsquune communication entre les machines ne sachève pas avec succès. Cette fonction peut être spécifiée dans la fenêtre INLINE CONFIG de la machine principale et de chaque machine satellite dans le système IRC.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne SYSTEM RETRY.
Sélectionnez DISABLE ou ENABLE avec la touche
.
(touche à alternance) et appuyez sur la touche c.
• Si la fonction de réessai du système est autorisée, une opération de transmission avec laquelle une erreur s’est produite ne sera pas achevée immédiatement, mais la machine principale attendra la sélection de l’une des trois instructions [RETRY (réessai), ABORT (arrêt d’exécution) ou IGNORE (ignore)] par l’intermédiaire du clavier. Ensuite, la machine principale réessayera d’accéder à la machine satellite qui a provoqué l’erreur de transmission ou terminera l’accès en tant que transmission réussie ou pas, selon la sélection choisie.
• Si la fonction n’est pas autorisée, l’opération est terminée immédiatement.
• Pour plus d’informations, voyez la section “Fonction de réessai du système” à la pages 63–64.
• Le réglage implicite est “ENABLE” (autorisé).
NOTA
5. Déclaration pour autoriser ou interdire la fonction de réessai du système lorsquune erreur de transmission se produit – machines principale et satellites
44
A une machine satellite, vous pouvez spécifier la machine (machine principale ou satellite) à partir de laquelle vous désirez rechercher tout dabord un code PLU/EAN. Si vous spécifiez que la machine principale doit rechercher tout dabord et introduire un code PLU/EAN, ce dernier sera recherché en priorité dans la machine principale, puis dans la machine satellite et vice versa. Cependant, le choix de linstruction de recherche fait dans la machine principale est invalidé. En dautres mots, même si vous spécifiez à la machine principale que la machine satellite doit tout dabord être recherchée la machine principale sera recherché en priorité.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne LOOKUP ORDER.
Sélectionnez MA (machine principale) ou SA (satellite) avec la touche
.
(touche à alternance) et appuyez sur la
touche
e
.
6. Choix pour rechercher dabord la machine principale ou une satellite pour un code PLU/EAN – machine satellite
45
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez READING et appuyez sur la touche
e
.
La fenêtre READING apparaîtra.
3. Sélectionnez INLINE CONFIG et appuyez sur la touche
e
.
La fenêtre INLINE CONFIG apparaîtra.
4. Sélectionnez INLINE PRESET et appuyez sur la touche
e
.
La fenêtre OUTPUT TO apparaîtra.
5. Sélectionnez DISPLAY ou REPORT PRINTER et appuyez
sur la touche
e
.
7. Lecture des contenus de la programmation IRC – machines principale et satellites
46
Exemple dimpression (machine principale)
Exemple dimpression (machine satellite)
Numéro terminal de la machine principale
N° de port MWS
Numéro terminal de la satellite
N° de port MWS Fonction de réessai du système (autorisée/interdite)
Liste des machines engagées dans le système IRC (N° du terminal et N° de machine)
Machine principale de sauvegarde (N° du terminal et N° de machine)
Machine à partir de laquelle le code PLU/EAN est tout dabord recherché
Machine à partir de laquelle le code PLU/EAN est tout dabord recherché
Fonction de réessai du système (autorisée/interdite)
47
Pour un raccordement dune imprimante à distance à un terminal ou des terminaux dans le système IRC, assurez-vous de consulter votre revendeur SHARP autorisé.
(1) Programmation de base pour limprimante à distance – machines
principale et satellites
Avec la procédure suivante, vous pouvez effectuer une programmation de base pour l(les) imprimante(s) à distance se trouvant dans le système IRC. Pour un réglage initial de limprimante à distance, veuillez consulter votre revendeur SHARP autorisé.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3.
Sélectionnez DEVICE CONFIG et appuyez sur la touche
e
.
La fenêtre DEVICE CONFIG apparaîtra.
4. Sélectionnez limprimante à distance (cuisine) devant être
programmée.
5. Effectuez la programmation pour limprimante à distance.
(Voyez à la page suivante pour la programmation des articles dune imprimante à distance individuelle.)
Assurez-vous de consulter votre revendeur SHARP autorisé pour des réglages appropriés.
6. Après la programmation de limprimante à distance, appuyez
sur la touche
c
.
8. Programmation pour limprimante à distance
48
Articles devant être programmés
TERMINAL#
Introduisez le numéro du terminal (1 ~ 254, 0).
CHANNEL#
Introduisez le numéro de la voie de transmission (0 ~ 7).
PRINTER
Sélectionnez le modèle de limprimante à distance.
TM-T88(3)/88(4) (EPSON) TM-U220/230 (EPSON) BUILT-IN(820) BUILT-IN(810)
AUTO CUTTER
Choisissez si vous interdisez ou autorisez la fonction automatique du coupeur.
NO: Interdit la fonction automatique du coupeur. YES: Autorise la fonction automatique du coupeur.
PRINT TYPE
Sélectionnez le type de reçu.
ADDITION: Type de reçu additionnel S/D: Type de reçu unique/double ADD.+S: Type de reçu additionnel + unique D ADD.: Type de reçu additionnel double D ADD+S: Type de reçu double (additionnel + unique)
SECOND KP
Introduisez le numéro de la seconde imprimante (cuisine) à distance (1 ~ 9, 0)
NAME
Introduisez le nom de limprimante à distance (12 caractères max.)
INITIAL FEED#
Introduisez lavancement par ligne initial pour limprimante à distance (0 à 64 lignes).
SORT RCPT. CUTTING
Choisissez si vous interdisez ou autorisez la fonction de coupage partiel entre chaque groupe de tri.
NO: Interdit la fonction de coupage partiel. YES: Autorise la fonction de coupage partiel.
SEQUENTIAL PRINT
Choisissez si vous interdisez ou autorisez la fonction dimpression séquentielle.
NO: Interdit la fonction dimpression séquentielle. YES: Autorise la fonction dimpression séquentielle.
49
(2) Programmation optionnelle pour limprimante à distance –
machines principale et satellites
Avec la procédure suivante, vous pouvez spécifier quels articles doivent être imprimés sur limprimante à distance.
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez OPTIONAL et appuyez sur la touche
e
.
La fenêtre OPTIONAL apparaîtra.
4. Sélectionnez PRINT SELECT2 et appuyez sur la touche
e
.
La fenêtre PRINT SELECT2 apparaîtra.
5. Effectuez les réglages appropriés pour les articles devant être
imprimés sur limprimante à distance et appuyez sur la touche
e
. (Voyez à la page suivante pour la programmation darticles individuels.)
6. Après la programmation des articles, appuyez sur la touche
c
.
50
Articles devant être programmés
SEPARATOR LINE
NO: Nimprime pas la ligne de séparation sur limprimante à distance. YES: Imprime la ligne de séparation sur limprimante à distance.
FREE TEXT ON KP
NO: Nimprime pas de texte disponible sur limprimante à distance. YES: Imprime un texte disponible sur limprimante à distance.
ITEM CODE ON KP
NO: Nimprime pas le code dun PLU/rayon sur limprimante à distance. YES: Imprime le code dun PLU/rayon sur limprimante à distance.
PRICE ON KP
NO: Nimprime pas le prix sur limprimante à distance. YES: Imprime le prix sur limprimante à distance.
AMOUNT ON KP
NO: Nimprime pas le montant sur limprimante à distance. YES: Imprime le montant sur limprimante à distance.
GUEST# ON KP
NO: Nimprime pas le numéro des clients sur limprimante à distance. YES: Imprime le numéro des clients sur limprimante à distance.
QTY=1 ON KP
NO: Nimprime pas les données dune quantité sur limprimante à distance lorsque la quantité est de
1.
YES: Imprime les données dune quantité sur limprimante à distance lorsque la quantité est de “1”.
UNIT PRICE PRINT
NO: Nimprime pas le prix unitaire sur limprimante à distance. YES: Imprime le prix unitaire sur limprimante à distance.
51
Linterface LAN pour le Terminal de Point de Vente de UP-820F/UP-820N permet à UP-820F/UP-820N deffectuer des communications de traitement direct à un ordinateur hôte par lintermédiaire du MWS. Pour le réglage du MWS, veuillez vous assurer de consulter votre revendeur SHARP autorisé.
Fonctions du poste de travail du directeur:
1) Téléchargement des données dun terminal [Terminal PC]
2) Téléchargement des données dun terminal [Terminal PC]
3) Fonction dentrée dune opération à distance (RJE) [Terminal PC]
4) Fonction T-LOG [Terminal PC]
5) Fonction de COURRIER ELECTRONIQUE [Terminal PC]
(1) Programmation dun numéro terminal du MWS
Le numéro terminal du MWS peut être spécifié avec la procédure suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez MWS CONFIG et appuyez sur la touche
e
.
La fenêtre MWS CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne IP ADDRESS 4.
Introduisez le numéro du terminal (0 ~ 254) sur la ligne IP ADDRESS 4 de MWS et appuyez sur la touche
c
.
Lentrée du numéro terminal de la machine elle-même
produira une ENTRY ERROR (erreur dentrée).
9. Programmation pour le poste de travail du directeur (MWS) – machines principale et satellites
52
(2) Programmation de la durée dattente
La valeur de la durée dattente pour la réception de données peut être spécifiée avec la procédure suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez MWS CONFIG et appuyez sur la touche
e
.
La fenêtre MWS CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne TIME OUT.
Introduisez la durée dattente (1 ~ 255 sec.) et appuyez sur la touche
c
.
Cette valeur (valeur de la durée dattente) dépend de son application. Veuillez consulter votre revendeur autorisé SHARP.
(3) Programmation du numéro de la passerelle
Le numéro de la passerelle peut être spécifié avec la procédure suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez SETTING et appuyez sur la touche
e
.
La fenêtre SETTING apparaîtra.
3. Sélectionnez MWS CONFIG et appuyez sur la touche
e
.
La fenêtre MWS CONFIG apparaîtra.
4. Déplacez le curseur sur la ligne G.W. ADDR.4.
Introduisez le numéro de la passerelle (0 ~ 254) et appuyez sur la touche
c
.
Lentrée du numéro terminal de la machine elle-même produira une ENTRY ERROR (erreur dentrée).
Lentrée dun même numéro que le numéro pré-introduit dans la ligne IP ADDRESS4 produira une ENTRY ERROR (erreur dentrée).
53
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez READING et appuyez sur la touche
e
.
La fenêtre READING apparaîtra.
3. Sélectionnez MWS CONFIG et appuyez sur la touche
e
.
La fenêtre OUTPUT TO apparaîtra.
4. Sélectionnez DISPLAT ou REPORT PRINTER et appuyez
sur la touche
e
.
N° du terminal Durée dattente (7 sec.) N° de la passerelle
Exemple dimpression (machine principale)
10. Lecture des contenus de la programmation du poste de travail du directeur (MWS) – machines principale et satellites
54
4
Système de sauvegarde
Le système IRC comporte un système de sauvegarde. Une des machines satellites peut être désignée pour servir en tant que machine principale de sauvegarde. Pour le réglage de la machine principale de sauvegarde, veuillez consulter votre revendeur SHARP autorisé.
Lorsque la machine principale et la machine principale de sauvegarde fonctionnent normalement, le système de travail se fait selon la séquence suivante:
1) Chaque machine satellite envoie des données GLU mises à jour (et les données des employés*) à la machine principale.
2) La machine principale reçoit les données et renvoie un signal daccusé de réception à la machine satellite.
3) La machine satellite envoie les données mises à jour à la machine principale de sauvegarde.
4) La machine principale de sauvegarde reçoit les données et renvoie un signal daccusé de réception à la machine satellite.
*Seulement pour le système dun fichier centralisé demployés.
Si la machine principale tombe en panne, la machine principale de sauvegarde prend la place de la machine principale après quune déclaration de la machine principale soit faite à la machine principale de sauvegarde. Si la machine principale de sauvegarde tombe en panne, la transmission des données mises à jour vers cette dernière peut être arrêtée par une déclaration de la machine principale de sauvegarde à la machine principale. Lorsque la machine principale ou la machine principale de sauvegarde retrouve une condition normale après la panne, elle reprend sa fonction de machine principale ou de machine principale de sauvegarde par une opération de déclaration de reprise.
1)
Données mises à jour
3)
Données mises à jour
2)
Signal d’accusé de réception
4)
Signal daccusé de réception
Machine satellite
Machine principale de sauvegarde
Machine principale
1. Comment fonctionne le système de sauvegarde IRC
55
Lorsque la machine principale ou la machine principale de sauvegarde tombe en panne, une procédure de déclaration de la machine principale doit être effectuée pour informer les machines satellites de la panne.
(1) Lorsque la machine principale tombe en panne – Déclaration de
la machine principale à la machine principale de sauvegarde
Circulation dune déclaration de la machine principale à la machine principale de sauvegarde
1) Une machine satellite détecte une panne de la machine principale au moyen de la fonction de réessai du système lorsquelle est en train denvoyer des données GLU mises à jour (et des données demployés*) à la machine principale. A ce moment, le message MASTER DOWN? (machine principale en panne?) apparaît à la fenêtre contextuelle de laffichage de la machine satellite. (Pour la fonction de réessai du système, voyez les pages 63–64.)
2) Lopération de déclaration de la machine principale doit être faite à la machine principale de sauvegarde. Cette opération informe les autres machines satellites que la machine principale est en panne et que la machine principale de sauvegarde sert en tant que machine principale. (Pendant ce processus, aucune autre opération ne peut être effectuée à chacune des machines satellites.)
3) Chaque machine satellite dans le système IRC commence à envoyer des données GLU mises à jour (et des données demployés*) à la machine principale de sauvegarde seulement.
4) La machine principale de sauvegarde reçoit les données et renvoie un signal daccusé de réception aux machines satellites.
*Seulement pour le système dun fichier centralisé demployés.
1) Détection dune panne
3) Données mises à jour
Machine satellite
4) Signal daccusé de réception
(Arrêt de la transmission)
Déclaration de la machine principale
Machine principale de sauvegarde
Machine principale
2) Opération de déclaration de la machine principale
2. Déclaration de la machine principale
56
La procédure de déclaration de la machine principale est la suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez DECLARATION et appuyez sur la touche
e
.
La fenêtre DECLARATION apparaîtra.
3. Sélectionnez MASTER DECLARE et appuyez sur la touche
e
.
Lorsque la machine principale est en panne, la machine principale de sauvegarde effectue un appel T-LOG à sa place.
NOTA
57
(2) Lorsque la machine principale de sauvegarde tombe en panne –
Déclaration de la machine principale de sauvegarde à la machine principale
Circulation dune déclaration de la machine principale de sauvegarde à la machine principale
1) Une machine satellite détecte une panne de la machine principale de sauvegarde au moyen de la fonction de réessai du système lorsquelle est en train denvoyer des données GLU mises à jour (et des données demployés*) à la machine principale ainsi qu’à la machine principale de sauvegarde. A ce moment, le message BACKUP DOWN? (machine principale de sauvegarde en panne?) apparaît à la fenêtre contextuelle de laffichage de la machine satellite.
2) Lopération de déclaration de la machine principale de sauvegarde doit être faite à la machine principale. Cette opération à informe les autres machines satellites de la panne survenue à la machine principale de sauvegarde.
3) Chaque machine satellite dans le système IRC commence à envoyer des données GLU mises à jour (et des données demployés*) à la machine principale seulement.
4) La machine principale reçoit les données et renvoie un signal daccusé de réception aux machines satellites.
*Seulement pour le système dun fichier centralisé demployés.
La procédure de déclaration de la machine principale est la même que celle dans (1) Lorsque la machine principale tombe en panne.
3) Données mises à jour
Machine satellite
4) Signal daccusé de réception
Machine principale de sauvegarde
Machine principale
2) Déclaration de la machine principale
1) Détection dune panne à la machine
principale de sauvegarde
(Arrêt de la transmission)
58
Lorsque la machine principale ou la machine principale de sauvegarde retrouve sa condition normale, une opération de déclaration de reprise devra être réalisée pour informer les machines satellites de cette reprise.
(1) Lorsque la machine principale retrouve sa condition normale –
Déclaration de reprise à la machine principale de sauvegarde
Circulation de la déclaration de reprise à la machine principale de sauvegarde
1) Lopération de déclaration de reprise est faite à la machine principale de sauvegarde.
2) Chaque machine satellite arrête denvoyer temporairement des données GLU mises à jour (et des données demployés*) à la machine principale de sauvegarde.
3) La machine principale de sauvegarde envoie les fichiers de données GLU mises à jour (et des données demployés*) à la machine principale.
4) La machine principale de sauvegarde informe toutes les machines satellites de la reprise de la machine principale.
5) Les machines satellites recommencent à envoyer des données GLU mises à jour (et des données demployés*) à la machine principale et le système IRC revient à une condition normale.
*Seulement pour le système dun fichier centralisé demployés.
3) Fichier de données mises à jour
Machine satellite
4) Information de reprise de la machine principale
2) Arrêt temporaire de la transmission
Déclaration de reprise
1) Opération de déclaration de reprise
Machine principale de sauvegarde
Machine principale
5) Reprise de la transmission des données mises à jour
3. Déclaration de reprise
59
La procédure de déclaration de reprise est la suivante:
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez DECLARATION et appuyez sur la touche
e
.
La fenêtre DECLARATION apparaîtra.
3. Sélectionnez RECOVER DECLARE et appuyez sur la
touche
e
.
60
(2) Lorsque la machine principale de sauvegarde retrouve sa
condition normale – Déclaration de reprise à la machine principale
Circulation de la déclaration de reprise à la machine principale
1) Une opération de déclaration de reprise est faite à la machine principale.
2) Chaque machine satellite arrête denvoyer temporairement des données GLU mises à jour (et des données demployés*) à la machine principale.
3) La machine principale envoie les fichiers de données GLU mises à jour (et des données demployés*) à la machine principale de sauvegarde.
4) La machine principale informe toutes les machines satellites de la reprise de la machine principale de sauvegarde.
5) Les machines satellites recommencent à envoyer des données GLU mises à jour (et des données demployés*) à la machine principale de sauvegarde et le système IRC revient à une condition normale.
*Seulement pour le système dun fichier centralisé demployés.
La procédure de déclaration de reprise est la même que celle dans (1) Lorsque la machine principale retrouve sa condition normale”.
2) Arrêt temporaire de la transmission
3) Fichier de données mises à jour
Machine satellite
4) Information de reprise de la machine principale de sauvegarde
Machine principale de sauvegarde
Machine principale
1) Déclaration de reprise
5) Reprise de la transmission des données mises à jour
61
5
Reprise en cas dune erreur
Avec lopération de suppression manuelle, vous pouvez effacer les mémoires de divers articles lorsque cest nécessaire. Cette opération ne devra être exécutée que lorsque la machine principale ou le système tombe en panne.
(1) Procédure de suppression manuelle
Dans le cas dun dérangement, vous pouvez contraindre les mémoires à effacer les articles provoquant un dérangement et restaurer votre système en utilisant la procédure suivante:
Procédure deffacement
1. Introduisez le mode PGM2 à partir de la fenêtre de sélection
du mode.
2. Sélectionnez DATA CLEAR et appuyez sur la touche
e
.
La fenêtre DATA CLEAR apparaîtra.
3. En vous référant à la liste montrée à la page suivante,
sélectionnez larticle correspondant et appuyez sur la touche
e
.
Les travaux de suppression manuelles mentionnés ci-dessus ne devront être réalisés que sur les conseils de votre revendeur SHARP autorisé.
NOTA
1. Opération de suppression manuelle
62
(2) Liste des articles dune suppression manuelle
Effacement manuel de la condition dentrée en communication dun employé
Effacement manuel de la condition de données GLU en utilisation
Effacement manuel de la mémoire des données générales (sur les rayons et les opérations)
Effacement manuel de la mémoire des données sur les ventes par heure
Effacement manuel de la mémoire des données sur les ventes par les employés
Effacement manuel de la mémoire des données sur les ventes par les caissiers
Effacement manuel de la mémoire des données sur les ventes nettes quotidiennes
Effacement manuel de la mémoire intermédiaire T-LOG (consignation des opérations)
Effacement manuel des données de la bande de détails quotidiens électronique
M
M
M
M
M
M
M
M
M
-
-
S
S
S
S
S
S
S
E
ffectif uniquement pour les employés qui sont dans une condition dentrée en communication à la machine principale.
(*2)
Cette opération supprime toutes les données GLU qui sont en cours dutilisation.
Seulement pour le système de caissier + employé
P
our un appel T-LOG, voyez page
19.
SIGN ON FLAG
GLU USED FLAG
TRANSACTION
HOURLY
CLERK
CASHIER
DAILY NET
T-LOG
E. JOURNAL
Machine
principale
(M)
Machine
satellite
(S)
Article Description
Terminal*1
Remarques
*
1
M signifie les fonctions de suppressions manuelles disponibles à la machine principale, alors que S signifie les
fonctions de suppressions manuelles disponibles aux machines satellites.
*2 Les données des ventes des employés pour chaque machine satellite dans laquelle un employé est entré en
communication ne sont pas rassemblées par un effacement manuel de la condition dentrée en communication. Les données des ventes des employés ne sont rassemblées que lorsquune opération de sortie de communication est effectuée correctement aux machines satellites.
63
Si une opération de transmission de la machine principale à une machine satellite ne se termine pas correctement, soit la machine principale termine immédiatement lopération, soit elle attend une instruction donnée par lintermédiaire du clavier, suivant si la fonction de réeessai du système est interdite ou autorisée. Lorsque la fonction de réessai du système est autorisée, la machine principale attend lentrée dune instruction et réessaie lentrée selon les instructions reçues comme il est expliqué à la page suivante. La fonction de réessai du système est disponible aussi aux machines satellites, selon lerreur de transmission.
Cette fonction est utilisée dans les cas suivants:
La machine principale narrive pas à effectuer un téléchargement de données prépositionnées ou de données de mises à jour à toutes ou à certaines des machines satellites.
La machine principale narrive pas à rassembler des données de rapports sur des ventes à toutes ou à certaines des machines satellites.
Une machine satellite narrive pas à effectuer un téléchargement de données à dautres machines.
Un employé narrive pas à sortir du système dentrée en communication à une machine satellite.*
Lorsque la fonction de réesai du système est autorisée ou interdite lorsquune erreur de transmission se produit, elle est programmée à la fois à la machine principale et aux machines satellites. (Voyez 5. Désignation pour autoriser ou interdire la fonction de réessai du système lorsquune erreur de transmission se produit” à la page 43.)
*Lorsquun employé ne réussit pas à sortir du système dentrée en communication à une machine
satellite pour certaine raison (par ex., la machine principale est occupée), les instructions RETRY (réessai) et ABORT (arrêt dexécution) sont disponibles, mais linstruction IGNORE ne lest pas.
(1) Lorsque la fonction de réessai du système est interdite
La machine principale termine immédiatement lopération de transmission des deux manières suivantes: Si aucune machine satellite na réussi à transmettre correctement des données, la transmission est considérée comme s’étant terminée avec une erreur, ce qui équivaut à ABORT (arrêt dexécution) comme il est expliqué à la page suivante. Si certaines machines satellites ont réussi à transmettre avec succès des données, la transmission est considérée comme réussie ou non réussie selon le type dopération de la transmission. Dans ce cas, la transmission considérée comme réussie et celle considérée comme non réussie sont respectivement équivalentes à IGNORE et ABORT, toutes deux étant expliquées à la page suivante.
2. Fonction de réessai du système
64
(2) Lorsque la fonction de réessai du système est autorisée
Si une erreur de transmission concernant une machine satellite se produit, la fenêtre concernée apparaîtra sur laffichage de la machine principale et la machine principale attendra lentrée de lune des instructions suivantes données par lintermédiaire du clavier.
A) Instruction RETRY (réessai) (sélection à partir du menu ou en appuyant sur la touche 1) B) Instruction ABORT (arrêt dexécution) (sélection à partir du menu ou en appuyant sur la touche 2) C) Instruction IGNORE (ignore) (sélection à partir du menu ou en appuyant sur la touche
correspondante: touche 2 ou 3)
A) Instruction RETRY:
Lorsque linstruction RETRY est sélectionnée, la machine principale essaye à nouveau daccéder à la machine satellite. Cependant, selon le type derreur (erreur dinstruction, etc.), il est évident que la machine principale ne pourra réussir à y accéder. Si ce type derreur se produit durant une transmission, il est possible que la machine principale ne réessaie pas.
B) Instruction ABORT:
Lorsque linstruction ABORT est sélectionnée, la machine principale termine laccès à la machine satellite et considère que la transmission ne sest pas achevée parfaitement. Cependant, dans le cas dun téléchargement de données programmées, linstruction ABORT ne peut être établie que lorsque toutes les machines satellites accédées sont dans une condition derreur.
C) Instruction IGNORE:
Lorsque linstruction IGNORE est sélectionnée, la machine principale termine laccès à la machine satellite, considère que la transmission sest terminée avec succès et nimprime seulement que les données transmises. Si aucune machine satellite na pu réussir à transmettre les données, linstruction IGNORE peut être établie à la machine principale dans le cas dune demande de données sur les ventes (rapport X), bien que le résultat ne soit pas imprimé.
[Réessai pendant une demande de données sur les ventes]
Pendant une remise à zéro, linstruction ABORT ne peut être donnée que lorsque chaque machine satellite accédée est dans une condition derreur. Les instructions IGNORE et RETRY sont disponibles inconditionnellement.
65
6
DONNEES TECHNIQUES DE BASE POUR LAN
Système de transmission: 10 Base-T, 100 Base-T
Vitesse de transmission: 10 Mbits/sec., 100 Mbits/sec.
Distance de transmission: Longueur du segment de 100 m max.
Câble de transmission: Câble à paire torsadée
Nombre de machines raccordable: Principale: 1
Satellites: 31 max. *Jusqu’à 31 machines sont exploitables avec le traitement par lots.
Jusqu’à 15 machines sont exploitables avec le traitement en temps réel.
UP820F820NV_2IF10
Loading...