Date: Aug. 21, 1995
COPIER : SF-2050/SD-2050
No. : STE-002
[Service Information]
A CHANGE TO THE INFORMATION IN THE SERVICE
MANUAL ON ADJUSTING THE MAIN POSITION OF THE
DEVELOPER MAGNET ROLLER.
1.Model Name: SF-2050/SD-2050
2.General: The explanation in the service guide of how to adjust the position of the developer
magnet roller is incorrect. Please use the corrected information below .
3.Description:
(2) Adjusting the main position of the developer magnet roller
(1) Take the device apart until you are at the position indicated in the figure to the right.
(2) Attach a string to a needle or a pin as shown to the right.
(3) Hold the string, and bring the needle closer to the MG roller. (the diameter of the MG
roller is small, so a paper clip will not be sufficiently small to mark the position correctly).
(4) Mark the position where the needle came into contact with the MG roller using a pen.
(5) Measure the distance between this position and the rib shown in the central figure.
Confirm that this distance is 18.0 +_ 0.2 mm. If the distance you measured is not within the
stated range, loosen screw A which fixes the main position adjustment board into place,
and adjust it in the direction indicated by the arrow in the figure.
.
Note:In order to make sure your measurement is correct, put spacers at both sides of
the base of the developer tank, and only move the needle horizontally.
Yellow
C