Sharp OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM, KOT1J0U Installation Instructions Manual

1
This Microwave Oven/Hood should be mounted against and
supported by a at vertical wall. The wall must be at for proper installation. If the wall is not at, use spacers to ll in the gaps.
Wall construction should be a minimum of 2" x 4" wood studding and 3/8" or more thick dry wall or plaster/lath. The mounting surfaces must be capable of supporting weight of 110 pounds— the oven and contents—AND the weight of all items which would normally be stored in the top cabinet above the unit.
The unit should be attached to a minimum of one 2" x 4" wall stud.
To nd the location of the studs, one of the following methods
may be used:
A. Use a stud nder, a magnetic device which locates the nails
in the stud.
B. Use a hammer to tap lightly across the mounting surface to
nd a solid sound. This will indicate stud location.
The center of the stud can be located by probing the wall with a small nail to nd the edges of the stud and then placing a mark halfway between the edges. The center of any adjacent studs will normally be 16" or 24" to either side of this mark.
NOTE: In the event that the unit will be unable to be supported by any stud, it will be necessary to use special care in the placement of the toggle bolts and top cabinet screws. See Wall Template for details. The top cabinet should be tested to ensure it is securely attached to the wall. Place extra weight up to 110 pounds inside the top cabinet to test the support.
2"x 4" Wood Studs
3/8" Dry Wall or Plaster/lath
16" or 24"
OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM
Please read all instructions thoroughly before installing the Microwave Oven/Hood System. Two people are recommended to install this product.
If a new electrical outlet is required, its installation should be completed by a qualied electrician before the Microwave Oven/Hood is installed. See 3 ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
This Microwave Oven/Hood requires a mounting space on a wall as shown in Figure 1.
If the space between the wall cabinets is greater than 30-inches (36-inches or 42-inches), a Filler Panel may be used to fill
the gap between the Microwave Oven/Hood system and wall
cabinets. The Filler Panel Kit should be installed before the Microwave Oven/Hood is installed.
For proper installation and servicing, a 2-inch space is necessary between the top of the range backsplash and the bottom of the Microwave Oven/Hood system.
1 MOUNTING SPACE
2 WALL CONSTRUCTION
INSTALLATION INSTRUCTIONS
30" or more
from cooking
surface
Backsplash
At least 2"
30"
12"
16.3"
66" or
more from
floor
Figure 2
Figure 1
2
3 ELECTRICAL GROUNDING INSTRUCTIONS
4 HOOD EXHAUST DUCT
5 TOOLS RECOMMENDED FOR INSTALLATION
This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current.
WARNING - Improper use of the grounding plug can result in a risk of electric shock.
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG.
The Power Supply Cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, single grounded receptacle. The receptacle should be located
inside the cabinet directly above the Microwave Oven/Hood
mounting location.
NOTE:
1. If you have any questions about the grounding or electrical instructions, consult a qualied electrician or serviceperson.
2. Neither Sharp nor the dealer can accept any liability for damage to the oven or personal injury resulting from failure to observe the correct electrical connection procedures.
When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely do not use plastic duct. Check that all connections are made securely. Please read the following carefully:
Exhaust connection: The hood exhaust has been designed to connect to a standard 31/4" x 10" rectangular duct. If round duct is required, a rectangular-to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between the studs, or wall should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate exhaust.
Maximum duct length: For satisfactory air movement, the total duct length of 31/4" X 10" rectangular or 6" diameter round duct should not exceed 140 feet.
Elbows, adapters, wall, roof caps, etc. present additional resistance to air flow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total length, add the equivalent lengths of all transitions and adapters plus the length of all straight duct sections. Figure 4 shows the approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating air flow resistance equivalent, which should total less than 140 feet.
• Phillips Screwdriver • 11/2" Wood Bit or Metal Hole Cutter (if metal cabinet is used)
• Electric Drill • 1/2", 5/8" and 3/32" Drill Bits
• Scissors • Saw to cut exhaust opening (if needed)
• Pencil • Measure
• Tape • Protective Drop Cloth for product and range—you may also use carton for protection
Ground
Receptacle
Opening for Power Cord
Figure 3
Figure 4
3
6 INSTALLATION HARDWARE
The following is a list of parts you may need for installing your Over-the-Range microwave oven. You will find the installation hardware contained in a packet with the unit. Check to make sure you have all these parts. Use this time to become familiar with each piece.
Item Name Quantity Parts code
1
Lag screws (1/4” x 1.8”) 2 9KC7117604511
2
Toggle Bolts and Nuts 3/16 x 2.7” 2
9KC3516003200 9KC3516003300
3
Cabinet Mounting Bolts 1/4” x 3-1/8 2 9KC7045607011
4
Washer (3/4”) 2 9KC3516003100
5
Nylon Grommet (for metal cabinets) 1 9KC3517503200
6
Damper 1 9KC3515400500
7
Mounting Plate 1 9KC351060009300
Lag screws (1/4” x 1.8”)
Toggle Bolts and Nuts
3/16 x 2.7”
Cabinet Mounting Bolts
1/4” x 3-1/8
Washer (3/4”) Nylon Grommet
(for metal cabinets)
Damper Mounting plate
Figure 5
1
4 5 6 7
2 3
4
7 VENTILATION SYSTEM
This Microwave Oven/Hood System is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation.
A. RECIRCULATING—Non-Vented, Ductless Operation
The unit is shipped assembled for recirculating.
NOTE:
1. The Exhaust Damper Assembly is not required for recirculating operation.
2. The Charcoal Filter should be replaced every 6 months, depending on use.
3. The Charcoal Filter is also sold as an accessory. See Operation Manual for ordering information.
B. Horizontal Ventilation System
Step 1.
* Remove the screws (1) and (2) for opening
the blower motor cover and save screws. Remove cover. See Figure 6.
Step 2.
* Remove the screws (3) for Blower
attachment and save screws. See Figure 7.
* Lift blower unit out of mounting location. See
Figure 8.
CAUTION:
Do not pull or stretch blower wiring.
Figure 7 Figure 8
Blower motor
Before : Fan blade openings facing Front
Blower motor cover
Back of OVEN
Figure 6
Loading...